A new model-based RSA method validated using CAD models and models from reversed engineering.

Roentgen stereophotogrammetric analysis (RSA) was developed to measure micromotion of an orthopaedic implant with respect to its surrounding bone. A disadvantage of conventional RSA is that it requires the implant to be marked with tantalum beads. This disadvantage can potentially be resolved with model-based RSA, whereby a 3D model of the implant is used for matching with the actual images and the assessment of position and rotation of the implant. In this study, a model-based RSA algorithm is presented and validated in phantom experiments. To investigate the influence of the accuracy of the implant models that were used for model-based RSA, we studied both computer aided design (CAD) models as well as models obtained by means of reversed engineering (RE) of the actual implant. The results demonstrate that the RE models provide more accurate results than the CAD models. If these RE models are derived from the very same implant, it is possible to achieve a maximum standard deviation of the error in the migration calculation of 0.06 mm for translations in x- and y-direction and 0.14 mm for the out of plane z-direction, respectively. For rotations about the y-axis, the standard deviation was about 0.1 degrees and for rotations about the x- and z-axis 0.05 degrees. Studies with clinical RSA-radiographs must prove that these results can also be reached in a clinical setting, making model-based RSA a possible alternative for marker-based RSA.

Algorithms↗

Repeatability of lung density measurements with low-dose computed tomography in subjects with alpha-1-antitrypsin deficiency-associated emphysema.

RATIONALE AND OBJECTIVES: Multislice computed tomography (MSCT) of the lungs provides a new opportunity for longitudinal assessment of lung densities because of shorter scan duration. The aim of the present study was to assess the intraindividual variation of lung densities measured by MSCT of patients with emphysema. METHODS: Ten patients with emphysema participated in a study in which MSCT was obtained on two occasions, approximately 2 weeks apart. Scanning parameters were 140 kV, 20 mAs, 4 x 2.5-mm collimation, and effective slice thickness of 2.5 mm. Lung density was measured as the 15th percentile point and the relative area below -910 Hounsfield units (HU) by using Pulmo-LKEB software. RESULTS: The mean difference of the 15th percentile point was -1.29 +/- 3.2 HU, and that for the relative area below the -910-HU parameter was -1.02% +/- 3.09%. Intraclass coefficients of variation were 0.96 (0.86-0.99) and 0.94 (0.8-0.98), respectively (95% confidence interval). CONCLUSIONS: Lung density parameters of emphysema derived by MSCT provide an opportunity for analysis of the treatment effects of new drugs on the progression of emphysema.

Disease Progression↗

Diastolic dysfunction in hypertensive heart disease is associated with altered myocardial metabolism.

BACKGROUND: Hypertension is an important clinical problem and is often accompanied by left ventricular (LV) hypertrophy and dysfunction. Whether the myocardial high-energy phosphate (HEP) metabolism is altered in human hypertensive heart disease and whether this is associated with LV dysfunction is not known. METHODS AND RESULTS: Eleven patients with hypertension and 13 age-matched healthy subjects were studied with magnetic resonance imaging at rest and with phosphorus-31 magnetic resonance spectroscopy at rest and during high-dose atropine-dobutamine stress. Hypertensive patients showed higher LV mass (98+/-28 g/m2) than healthy control subjects (73+/-13 g/m2, P<0.01). LV filling was impaired in patients, reflected by a decreased peak rate of wall thinning (PRWThn), E/A ratio, early peak filling rate, and early deceleration peak (all P<0. 05), whereas systolic function was still normal. The myocardial phosphocreatine (PCr)/ATP ratio determined in patients at rest (1. 20+/-0.18) and during stress (0.95+/-0.25) was lower than corresponding values obtained from healthy control subjects at rest (1.39+/-0.17, P<0.05) and during stress (1.16+/-0.18, P<0.05). The PCr/ATP ratio correlated significantly with PRWThn (r=-0.55, P<0.01), early deceleration peak (r=-0.56, P<0.01), and with the rate-pressure product (r=-0.53, P<0.001). CONCLUSIONS: Myocardial HEP metabolism is altered in patients with hypertensive heart disease. In addition, there is an association between impaired LV diastolic function and altered myocardial HEP metabolism in humans. The level of myocardial PCr/ATP is most likely determined by the level of cardiac work load.

Adenosine Triphosphate↗

Sources of error in lung densitometry with CT.

RATIONALE AND OBJECTIVES: To determine and analyze the most important error sources in lung CT densitometry in vivo. METHODS: The authors examined the influences of CT acquisition errors, physiologic changes, and image segmentation errors on lung densitometry. Among others, spatial dependency and long-term reproducibility of the density measurements of blood and air were examined over a period of 4 years in a group of 28 patients with pulmonary emphysema. These results were related to the measured lung densities in this group. RESULTS: The density measurement of blood and air is strongly dependent on the position in the thorax. Despite full-scanner calibrations, x-ray tube replacement can induce a significant increase in measured blood density. CONCLUSIONS: A change in a lung density parameter over time can actually be the result of tube replacement or changing blood density. A simple postprocessing technique can correct for these changes.

Absorptiometry, Photon↗

MR velocity mapping of tricuspid flow: correction for through-plane motion.

We evaluated the effect of through-plane motion on tricuspid flow measurements performed with MR velocity mapping in nine normal subjects and 15 patients with possible right ventricular (RV) disease. Eight parameters of RV diastolic function were derived from the tricuspid flow measurements, both before and after a correction for through-plane motion. Measurements of E-peak, A-peak, and time-to-peak filling rate changed significantly after correction for through-plane motion (P < .05). Tricuspid flow as a marker of RV diastolic function should be corrected for the effect of through-plane motion to improve functional evaluation of the RV.

Adult↗