PubMed Health⌕ Search

Biomedical subjects

B Coombs

Publications and source records attributed to B Coombs.

2 recordsLinked to original sources

Double-echo three-point-Dixon method for fat suppression MRI.

A double-echo two-excitation pulse sequence encoding fat and water signals for a phase-sensitive three-point Dixon-type analysis (DE-3PD) was developed and implemented on a 1.5 T MR imager. Data processing was performed using a previously developed two-dimensional (2D) region-growing algorithm, adapted to use double-echo data. Density-, T1-, and T2-weighted fat suppression images were obtained from six volunteers using the new fat suppression method. The images were compared with corresponding images obtained using frequency-selective excitation fat suppression (FATSAT) and a single-echo three-point-Dixon method (SE-3PD). The results demonstrate that the DE-3PD sequence shortens the imaging time by one-third compared with the SE-3PD method, without loss in image quality. The data also show that a 2D region-growing algorithm effectively unwraps the phase of DE-3PD data sets, and that results of DE-3PD fat signal suppression are consistently better than those obtained using a standard FATSAT method. The authors conclude that the double-echo sequence provides density-, T1-, and T2-weighted images that appear to be promising for routine clinical applications.

Abdomen↗

Coronary arteriography performed by a physician assistant.

Funding constraints and an oversupply of cardiologists mitigate against continued training of increasing numbers of cardiology fellows. In some institutions, the workload of the catheterization laboratory is an overriding factor. The ability of a physician assistant to perform some of this work was tested to determine if the number of fellows and the content of the fellowship training program could be uncoupled from the catheterization laboratory workload. Among the first 150 patients in whom coronary arteriography was performed by a physician assistant, no patient died or had a myocardial infarction or stroke. Two patients (1.3%) had minor complications: a retinal embolus and an infected puncture site. The complication rate in 150 consecutive cases performed by fellows was also 1.3%, a small myocardial infarction and a transient ischemic attack. Procedure times for the physician assistant and for the fellows were 41 +/- 13 and 44 +/- 18 minutes for preoperative patients and 62 +/- 24 and 70 +/- 20 minutes for postoperative patients. Corresponding fluoroscopy times were 11 +/- 5 and 12 +/- 7 minutes for the preoperative and 22 +/- 12 and 20 +/- 6 for postoperative patients. Only preoperative fluoroscopy times were statistically different (p = 0.02). Thus, substituting a physician assistant for a fellow to perform coronary arteriography is an option in institutions at which the number of studies exceeds the training needs of fellows.

Angiography↗