PubMed Health⌕ Search

Biomedical subjects

B D MacCraith

Publications and source records attributed to B D MacCraith.

5 recordsLinked to original sources

Determination of hydrocarbons using sapphire fibers coated with poly(dimethylsiloxane).

A poly(dimethylsiloxane) (PDMS) coated sapphire fiber has been investigated as a sensor for hydrocarbons (HCs) in the mid-infrared region around 3000 cm(-1). In order to optimize and predict sensor response, the diffusion behavior of the analytes into the PDMS preconcentration medium has been examined. A diffusion model based on Fickian diffusion was used to quantify diffusion. The model incorporated such factors as film thickness, refractive index of the polymer and the fiber core, and principal wavelength at which the analyte absorbs. A range of hydrocarbons, from hexane to pentadecane, was analyzed at 2930 cm(-1) using both fiber-coupled Fourier transform infrared spectroscopy and a modular prototype system. Diffusion coefficients were determined for these compounds and diffusion behavior examined and related to factors such as analyte polarity and molecular size. The diffusion coefficients were found to range from 6.41 x 10(-11) 5 x 10(-12) to 5.25 x 10(-11) +/- 9 x 10(-13) cm2 s(-1) for hexane and pentadecane into a 2.9 microm PDMS film, respectively. The diffusion model was also used to examine the effect of changing system parameters such as film thickness in order to characterize sensor response.

Aluminum Oxide↗

Development and application of surface plasmon resonance-based biosensors for the detection of cell-ligand interactions.

Surface plasmon resonance (SPR)-based biosensors were investigated with a view to providing a portable, inexpensive alternative to existing technologies for "real-time" biomolecular interaction analysis of whole cell-ligand interactions. A fiber optic SPR-based (FOSPR) biosensor, employing wavelength-dependent SPR, was constructed to enable continuous real-time data acquisition. In addition, a commercially available integrated angle-dependent SPR-based refractometer (ISPR) was modified to facilitate biosensing applications. Solid-phase detection of whole red blood cells (RBCs) using affinity-captured blood group specific antibodies was demonstrated using the BIACORE 1000, BIACORE Probe, FOSPR, and ISPR sensors. Nonspecific binding of RBCs to the hydrogel-based biointerface was negligible. However, the background noise level of the FOSPR-based biosensor was approximately 25-fold higher than that of the widely used BIACORE 1000 system while that of the ISPR-based biosensor was over 100-fold higher. Nevertheless, the FOSPR biosensor was suitable for the analysis of macromolecular analytes contained in crude matrices.

Biosensing Techniques↗

Optical biosensing of nitrite ions using cytochrome cd1 nitrite reductase encapsulated in a sol-gel matrix.

Nitrite is an important human health and environmental analyte. As such, the European Union (EU) has imposed a limit for nitrite in potable water of 0.1 mg l-1 (2.18 microM). In order to develop an optical biosensing system for the determination of nitrite ions in environmental waters, cytochrome cd1 nitrite reductase has been extracted and purified from the bacterium Paracoccus pantotrophus. The protein has been spectroscopically characterised in solution and important kinetic parameters of nitrite reduction of the cytochrome cd1 enzyme, i.e., Km, Vmax and kcat have been determined. The influence of pH on the activity of the cytochrome cd1 has been investigated and the results suggest that this enzyme can be used for the determination of nitrite in the pH range 6-9. Biosensing experiments with the cytochrome cd1 in solution suggested that the decrease in intensity of the absorption band associated with the d1 haem (which is the nitrite binding site), at 460 nm, with increasing nitrite concentrations would enable the measurement of this analyte with the optimum limit of detection. The cytochrome cd1 has been encapsulated in a bulk sol-gel monolith with no structural changes observed and retention of enzymatic activity. The detection of nitrite ions in the range 0.075-1.250 microM was achieved, with a limit of detection of 0.075 microM. In order to increase the speed of response, a sol-gel sandwich thin film structure was formulated with the cytochrome cd1. This structure enabled the determination of nitrite concentrations within ca. 5 min. The sol-gel sandwich entrapped cytochrome cd1 enzyme was found to be stable for several months when the films were stored at 4 degrees C.

Biosensing Techniques↗

Array biosensor for simultaneous identification of bacterial, viral, and protein analytes.

The array biosensor was fabricated to analyze multiple samples simultaneously for multiple analytes. The sensor utilized a standard sandwich immunoassay format: Antigen-specific "capture" antibodies were immobilized in a patterned array on the surface of a planar waveguide and bound analyte was subsequently detected using fluorescent tracer antibodies. This study describes the analysis of 126 blind samples for the presence of three distinct classes of analytes. To address potential complications arising from using a mixture of tracer antibodies in the multianalyte assay, three single-analyte assays were run in parallel with a multianalyte assay. Mixtures of analytes were also assayed to demonstrate the sensor's ability to detect more than a single species at a time. The array sensor was capable of detecting viral, bacterial, and protein analytes using a facile 14-min assay with sensitivity levels approaching those of standard ELISA methods. Limits of detection for Bacillus globigii, MS2 bacteriophage, and staphylococcal enterotoxin B (SEB) were 10(5) cfu/mL, 10(7) pfu/mL, and 10 ng/mL, respectively. The array biosensor also analyzed multiple samples simultaneously and detected mixtures of the different types of analytes in the multianalyte format.

Antibodies↗

Personal ammonia sensor for industrial environments.

The realisation of an opto-chemical ammonia sensor suitable for personal monitoring tasks is described, comprising a cyanine dye immobilised in a microporous glass thin film. The fabrication of sensor platforms incorporating embossed grating couplers provides a compact optical design with effective waveguiding characteristics, resulting in reversible ammonia sensitivity in the 5-100 ppm range in under 2 min. Cross-sensitivity of sensor response with water and other potential interferents is considered.

Air Pollution, Indoor↗