PubMed HealthSearch

Biomedical subjects

B D Ratner

Publications and source records attributed to B D Ratner.

At least 19 recordsLinked to original sources

Direct measurement of hydrogen bonding in DNA nucleotide bases by atomic force microscopy.

We have used self-assembled purines and pyrimidines on planar gold surfaces and on gold-coated atomic force microscope (AFM) tips to directly probe intermolecular hydrogen bonds. Electron spectroscopy for chemical analysis (ESCA) and thermal programmed desorption (TPD) measurements of the molecular layers suggested monolayer coverage and a desorption energy of about 25 kcal/mol. Experiments were performed under water, with all four DNA bases immobilized on AFM tips and flat surfaces. Directional hydrogen-bonding interaction between the tip molecules and the surface molecules could be measured only when opposite base-pair coatings were used. The directional interactions were inhibited by excess nucleotide base in solution. Nondirectional van der Waals forces were present in all other cases. Forces as low as two interacting base pairs have been measured. With coated AFM tips, surface chemistry-sensitive recognition atomic force microscopy can be performed.

Adenine

Silicone derivatives for contact lenses: functionalization, chemical characterization, and cell compatibility assessment.

Epoxy ring-opening functionalization of polymers at random sites along chains with various chemical groups has been demonstrated. The reaction is performed in an aqueous solution under mild conditions in order to minimize degradation of the macromolecular chains. Silicone lenses made of copolymers with epoxy side chains were functionalized with 4-hydroxybutyric acid, sodium salt. The carboxylated silicone derivatives were characterized by ESCA and radiotracers. A mean value of 30% reaction yield was concluded, based upon data from both methods; nevertheless, the latter can be improved up to 50% or more if the conditions of preparation of the epoxydized silicone lenses are optimized. Derivatized silicones were coated in the wells of culture plates to evaluate the cell compatibility of these new polymers with a fibroblast cell line (McCoy's). No cellular toxicity was observed.

Benzylamines

Variations between Biomer lots. I. Significant differences in the surface chemistry of two lots of a commercial poly(ether urethane).

We have studied the surface chemistry of two lots of Biomer (BSP067 and BSUA001), a widely used commercial poly(ether urethane) (PEU). Although transmission infrared adsorption studies revealed no differences in the bulk chemistry of the two lots, the surface chemistry, as seen by x-ray photoelectron spectroscopy (XPS) and static secondary ion mass spectrometry (SIMS), was different. Lot BSP067 showed soft-segment enrichment at the surface, which is typical of PEU. Lot BSUA001 showed no evidence of either hard- or soft-segment PEU components at the surface. The surface of this lot was completely covered with a nonextractable additive identified as poly(diisopropyl amino ethyl methacrylate). Small amounts of a low-molecular-weight antioxidant were observed at the surface of both samples. Because the biological response to polymers is dependent on surface structure, these results are of considerable importance to biomaterials research.

Antioxidants

Glow discharge plasma deposition of tetraethylene glycol dimethyl ether for fouling-resistant biomaterial surfaces.

The glow discharge plasma deposition (GDPD) of tetraethylene glycol dimethyl ether is introduced as a novel method for obtaining surfaces that are resistant to protein adsorption and cellular attachment. Analysis of films by x-ray photoelectron spectroscopy and several biological assays indicate the formation of a fouling-resistant, PEO-like surface on several substrata (e.g., glass, polytetrafluoroethylene, polyethylene). Adsorption of 125I-radiolabelled proteins (fibrinogen, albumin and IgG) from buffer and plasma was very low (typically less than 20 ng/cm2) when compared to the untreated substrata, which exhibited much higher levels of protein adsorption. Not all coated substrata adsorbed equal amounts of protein (e.g., coated glass samples typically adsorbed more protein than coated polyethylene or coated polytetrafluoroethylene samples), suggesting that the substratum used may affect the amount of protein adsorbed. Measurement of dynamic platelet adhesion, using epifluorescent video microscopy, and endothelial cell attachment further demonstrates the short-term nonadhesiveness of these surfaces.

Adsorption

Postadsorptive transitions in fibrinogen adsorbed to polyurethanes: changes in antibody binding and sodium dodecyl sulfate elutability.

Residence time-dependent changes in fibrinogen after adsorption to six different polyurethanes were examined by measuring polyclonal antifibrinogen binding to the adsorbed protein. The amount of adsorbed fibrinogen that could be eluted by sodium dodecyl sulfate (SDS) was also measured. Baboon fibrinogen was first adsorbed from dilute plasma to the polymers, which were then stored in either buffer or buffered albumin solution prior to testing. Subsequently, the amount of antifibrinogen bound by the adsorbed fibrinogen was measured using a direct enzyme linked immunosorbent assay (ELISA). Alternatively, the surface with the adsorbed fibrinogen was soaked in a 3% SDS solution, and the amount of retained 125I-radiolabeled fibrinogen was measured. With increasing residence time, decreases in both antibody binding and the SDS elutability of the adsorbed fibrinogen occurred, but the rate of change was dependent on the polyurethane to which the fibrinogen was adsorbed. In addition, the antibody binding per unit of adsorbed fibrinogen, when measured immediately after the adsorption step, varied by approximately a factor of 3 among the various polyurethanes. When the protein-coated surfaces were stored in buffered albumin solution rather than buffer, the decrease in the reactivity of fibrinogen with residence time did not occur on some of the surfaces. This study shows that the chemical properties of the adsorbing surface influence the rate at which adsorbed fibrinogen undergoes change. The significance of the polymer-dependent changes in adsorbed fibrinogen with respect to blood reactions with polymers is discussed.

Adsorption

Adsorption of baboon fibrinogen and the adhesion of platelets to a thin film polymer deposited by radio-frequency glow discharge of allylamine.

Platelet adhesion under static and flow conditions from a washed platelet suspension containing albumin to a polymer deposited by radio-frequency glow discharge of allylamine vapour on a poly(ethylene terephthalate) substrate was measured. Electron spectroscopy for chemical analysis was used to characterize the surface. Fibrinogen adsorption from a series of dilute plasma solutions to radio-frequency glow discharge/allylamine, measured using 125I radiolabelled baboon fibrinogen, increased with decreasing plasma dilution to a level much higher than that previously observed on polyurethanes. Elutability by sodium dodecyl sulphate of fibrinogen adsorbed from dilute plasma also increased with increasing plasma concentration, but fibrinogen preadsorbed from plasma became non-elutable when surfaces were stored in buffer for 5 d before contact with sodium dodecyl sulphate. Platelet adhesion to substrates which had been pre-adsorbed with dilute plasma was measured using baboon platelets radiolabelled with 111In. Adhesion greatly decreased as the plasma concentration used for preadsorption increased, suggesting that non-specific platelet binding to the bare surface occurs when protein coverage is incomplete. Non-specific platelet binding was inhibited to varying degrees by preadsorption of different proteins to the surface. Platelet adhesion to surfaces preadsorbed with dilute (1.0%) baboon and human plasmas lacking fibrinogen (i.e. serum, heat-defibrinogenated plasma and congenitally afibrinogenemic plasma) was diminished compared with normal plasma. Addition of exogenous fibrinogen to the deficient plasma partially restored platelet adhesion to normal levels. Adhesion to surfaces preadsorbed with human plasma deficient in von Willebrand factor was comparable to that observed with normal plasma. The plasma preadsorption studies with fibrinogen deficient media suggested that adsorbed fibrinogen is necessary for platelet adhesion to the radio-frequency glow discharge/allylamine substrate at high protein coverage. However, since adhesion was greatly reduced when the plasma preadsorbed substrate was stored in buffer before platelet contact, the conformation of adsorbed fibrinogen is also important in mediating platelet adhesion to radio-frequency glow discharge.

Adsorption

Surface characterization of 2-hydroxyethyl methacrylate/styrene copolymers by angle-dependent X-ray photoelectron spectroscopy and static secondary ion mass spectrometry.

The surface composition and structure of three structurally distinct amphiphilic copolymers of 2-hydroxyethyl methacrylate (HEMA) and styrene have been examined with angle-dependent X-ray photoelectron spectroscopy (XPS) and static secondary ion mass spectrometry (SIMS). The phase-separated block copolymer made by anionic living polymerization, HSH-A50, showed significant surface enrichment of styrene. The outermost 2-3 A appeared to be approximately 100% styrene, with the styrene concentration decreasing to its bulk value at a depth of approximately 50 A from the surface. However, HEMA was detected in the outer 20 A of this copolymer. The presence of HEMA in the surface region implies this copolymer may undergo significant restructuring when hydrated in a hydrophilic environment (as opposed to the hydrophobic environment in which the sample was prepared and analyzed). The phase-separated block copolymer made by telechelic coupling of free radical polymerized functionalized oligomers, HSH-B60, showed only slight styrene enrichment at the surface. Both HEMA and styrene were detected at all sampling depths, including the outermost surface layer, consistent with the presence of discrete HEMA and styrene domains at the copolymer surface. Since both components are already present at the surface under hydrophobic conditions, the degree of restructuring this copolymer may undergo upon hydration should be minor. The random HEMA--styrene copolymer made by conventional free radical initiation techniques, HS-RAN50, had a surface composition that was similar to the bulk composition and independent of depth, as expected for a homogeneously mixed copolymer film.

Biocompatible Materials

Plasma deposition for biomedical applications: a brief review.

Radio frequency plasma-deposited thin films offer an advantageous mechanism to alter the surface properties of biomaterials and medical devices without affecting the mechanical properties or primary fabrication. Such coatings are tightly adherent, conformal, and easily applied. They also exhibit excellent biocompatibility qualities. Examples are presented of four different thin film plasma treatments that show promise for reducing the platelet reactivity of materials, enhancing their ability to grow cells, preventing protein pickup by surfaces, and improving the biocompatibility of ophthalmic devices.

Adsorption

Static secondary-ion mass spectrometric investigation of the surface structure of organic plasma-deposited films prepared from stable-isotope-labeled precursors. 1. Carbonyl precursors.

Stable-isotope-labeled carbonyl precursors (acetaldehyde, acetone, and 2-butanone) were used to create plasma-deposited films (PDFs), which were then examined by positive- and negative-ion static SIMS. This allowed hydrocarbon (HC) fragments to be distinguished from oxygen-containing fragments in the static SIMS spectra of these PDFs. Both the positive- and negative-ion static SIMS fragmentation patterns of conventional HC and oxygen-containing polymers were qualitatively examined in order to assign structural units on the PDF surface that could account for the sallent features in the static SIMS fragmentation patterns of these PDFs.

Hydrocarbons

Baboon fibrinogen adsorption and platelet adhesion to polymeric materials.

The role of fibrinogen in mediating platelet adhesion to polymers exposed to blood plasma was studied by comparison of the effect of plasma dilution on fibrinogen adsorption and platelet adhesion, and by the use of coagulation factor deficient plasmas. Polyetherurethane substrates were first preadsorbed with dilute plasma, then contacted with washed platelets suspended in a modified, apyrase containing Tyrode's buffer. Platelet adhesion was studied under static conditions in Multiwell dishes, and also under shearing conditions using a parallel plate perfusion chamber. Fibrinogen adsorption and platelet adhesion were measured using 125I radiolabeled baboon fibrinogen and 111In radiolabeled baboon platelets, respectively. Surfaces were characterized by electron spectroscopy for chemical analysis (ESCA). When fibrinogen adsorption to Biomer was measured after 2 h contact with a series of dilute plasma solutions under static conditions, a peak in adsorption was observed from 0.26% plasma, i.e., adsorption was greater from 0.26% plasma than from either more or less dilute plasma. A peak in subsequent platelet adhesion to the plasma preadsorbed surfaces, measured after 2 h static incubation with washed platelets, was also observed but occurred on Biomer preadsorbed with 1.0% plasma. When fibrinogen adsorption was measured after 5 min contact under shearing conditions, the fibrinogen adsorption peak occurred on surfaces that had been exposed to 1.0% plasma. A peak in platelet adhesion to these preadsorbed surfaces, measured after 5 min contact with the platelet suspensions under shearing conditions, was observed on Biomer preadsorbed with 0.1% plasma. Shifts between the positions of the peaks in protein adsorption and platelet adhesion occurred on other polymers tested as well. Platelet adhesion was almost completely inhibited when baboon and human plasmas lacking fibrinogen (i.e., serum, heat defibrinogenated plasma, and congenitally afibrinogenemic plasma) were used. Platelet adhesion was restored to near normal when exogenous fibrinogen was added to fibrinogen deficient plasmas. Adhesion was also inhibited completely when a monoclonal antibody directed against the glycoprotein IIb/IIIa complex was added to the platelet suspension. Platelet adhesion to surfaces preadsorbed to von Willebrand factor deficient plasma was the same as to surfaces preadsorbed with normal plasma. While it appears that surface bound fibrinogen does mediate the initial attachment of platelets to Biomer, the observation that the fibrinogen adsorption and platelet adhesion maxima do not coincide exactly also suggests that the degree of subsequent platelet adhesion is dictated not only by the amount of surface bound fibrinogen but also by its conformation.

Adsorption

Postadsorptive transitions in fibrinogen adsorbed to biomer: changes in baboon platelet adhesion, antibody binding, and sodium dodecyl sulfate elutability.

Residence-time-dependent changes in fibrinogen after its adsorption to Biomer were examined by measuring platelet adhesion and antibody binding to the adsorbed protein, and the amount of adsorbed fibrinogen which could be eluted by sodium dodecyl sulfate (SDS). Baboon fibrinogen was first adsorbed (from either pure solution or dilute plasma) to Biomer, which was then stored in either buffer or buffered albumin solution prior to testing. Subsequently, the adherent protein layer was either probed for fibrinogen capable of mediating platelet adhesion using 111In radiolabeled, washed platelet suspensions under both static and shearing conditions, or for fibrinogen capable of binding antibody using a direct enzyme linked immunosorbent assay (ELISA). Alternatively, the surface with the adsorbed protein layer was soaked in a 3% SDS solution, and the amount of 125I radiolabeled fibrinogen retained was measured. Decreases in platelet and antibody binding, and in the SDS elutability of the adsorbed fibrinogen after it was stored in buffer were detected, although different rates of decrease were observed for each method. When the protein-coated surfaces were stored in buffered albumin solution rather than buffer, the decrease in the reactivity of fibrinogen was prevented. While each of the three assays measures a different property of adsorbed fibrinogen, this study suggests that the adherent protein undergoes time dependent conformational changes which render it less reactive toward platelets and antibodies, and more resistant to elution by SDS.

Adsorption

Endothelial cell growth on oxygen-containing films deposited by radio-frequency plasmas: the role of surface carbonyl groups.

Polystyrene substrates were modified by radio-frequency plasma deposition from mixtures of various organic vapors (acetone, methane, methanol, and formic acid) and oxygen. The resulting surfaces exhibited a wide range of surface oxygen concentrations, as measured by electron spectroscopy for chemical analysis (ESCA). The surface hydroxyl, carboxyl, and carbonyl groups were derivatized with trifluoroacetic anhydride, trifluoroethanol, or hydrazine, respectively, and their concentrations subsequently determined by ESCA. The growth of bovine aortic endothelial cells was found to increase with the surface carbonyl concentration but did not appear to correlate with the hydroxyl or carboxyl concentrations.

Acetone

TFE-plasma polymerized dermal sheep collagen for the repair of abdominal wall defects.

The aim of this study was to design and evaluate a degradable biomaterial for the repair of abdominal wall defects. Hexamethylenediisocyanate-tanned dermal sheep collagen (HDSC) was plasma-polymerized with tetrafluoroethylene (TFE) which resulted in a hydrophobic surface on the visceral side (TFE-HDSC). Full-thickness abdominal wall defects were made in rats and repaired with HDSC or TFE-HDSC implants. Unmodified HDSC implants showed excellent fixation to the adjacent muscle tissue but intestinal adhesions were observed. These implants showed insufficient strength after four weeks, illustrated by bulging of the peritoneal contents (herniation). Plasma-polymerized implants after four weeks of implantation showed firm incorporation into the surrounding muscle tissue. With one exception there were no bowel adhesions. Fewer herniations were observed, indicating a prolonged degradation period. Further studies on the optimalization of degradation time are in progress.

Abdominal Muscles

Poly(dimethylsiloxane)-poly(ethylene oxide)-heparin block copolymers. III: Surface and bulk compositional differences.

Previously observed bioactivity of poly(dimethylsiloxane)-poly(ethylene oxide)-heparin (PDMS-PEO-Hep) triblock copolymers has prompted studies of the surface and bulk character of this copolymer using angular-dependent electron spectroscopy for chemical analysis (ADESCA), static secondary mass spectroscopy (SIMS), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA). Because the low-energy PDMS phase dominates surfaces of this copolymer when solvent cast under air or vacuum conditions, attempts were made to explain surface restructuring and rearrangements induced in hydrated or aqueous environments that permit surface accessibility and bioactivity of heparin moieties. Based on comparisons with PDMS, PEO, and heparin homopolymers, PEO/heparin blends, and an unheparinized PDMS-PEO diblock copolymer, PDMS-PEO-heparin demonstrates both phase-mixed and phase-separated regions in DSC analysis. During annealing cycles above the Tg values of the copolymer constituents, phase-mixed regions become increasingly phase separated and PEO enriched. TGA analysis confirmed the presence block copolymer constituents and presented evidence of intermolecular segmental interactions, hence phase-mixing in the copolymers. ADESCA analysis indicates that the outer 5 A of both the PDMS-PEO and PDMS-PEO-Hep copolymers is essentially pure PDMS. However, significant amounts of PEO are detected 5 to 20 A below the surface. Static SIMS also detects the presence of PDMS at the surfaces of the PDMS-PEO and PDMS-PEO-Hep copolymers. Compositional models based on ADESCA, SIMS, and DSC data are presented for desiccated and hydrated copolymer surfaces.

Biocompatible Materials

Characterization of alkyl grafted polyurethane block copolymers by variable takeoff angle x-ray photoelectron spectroscopy.

Variable takeoff angle x-ray photoelectron spectroscopy was used to determine the surface composition of five polyurethane block copolymers. The high-resolution C1s spectra from all five polyurethane samples had peaks at binding energies of 285.0, 286.5, and 289.5 eV, which are consistent with the presence of hydrocarbon, ether, and urethane carbon species. Both the measured elemental compositions at the low takeoff angles (deepest sampling depths) and the calculated elemental compositions for depths greater than 15 A generally showed good agreement with the expected bulk compositions. The outer 15 A of the surface of all five samples was depleted in the nitrogen-containing hard segment. For the base polyurethane sample in this series, an enrichment of the poly(tetramethylene oxide) soft segment and the presence of an organic silicone impurity were detected. Doubling the chain length of both the hard and soft segments resulted in a further decrease of the hard segment concentration in the outer surface of the sample. The grafting of C2 and C18 alkyl groups onto 10 or 20% of the urethane linkages resulted in an increase in the percentage of aliphatic carbon species present on the surface. In the case of the C18-alkylated material, the presence of alkyl chains at the surface was inferred using contact angle measurements.

Biocompatible Materials

Radiofrequency plasma deposition of oxygen-containing films on polystyrene and poly(ethylene terephthalate) substrates improves endothelial cell growth.

Polystyrene and poly(ethylene terephthalate) substrates were modified by radiofrequency plasma deposition with organic vapors comprised of carbon, oxygen, and hydrogen (acetone, methanol, glutaraldehyde, formic acid, allyl alcohol, and ethylene oxide). The treatments resulted in the deposition of a film at least 100 A thick containing up to 26% atomic oxygen at the surface. A high oxygen incorporation was observed for vapors with a large oxygen-to-carbon ratio. Bovine aortic endothelial cell growth measured on acetone, methanol, and glutaraldehyde films was linearly correlated with the oxygen content of the treated surfaces. Nitrogen was incorporated in the surface by blending nitrogen gas into the organic vapor used for plasma deposition. The resulting nitrogen-containing substrates exhibited a high affinity for serum fibronectin but a moderate cell growth.

Adsorption

Adhesion and aggregation of thrombin prestimulated human platelets: evaluation of a series of biomaterials characterized by ESCA.

Five materials of interest in blood contact applications (PVC, Silastic, Biomer and siliconized glass) were internally coated on glass tubes and exposed to suspensions of platelets and red cells. Uncoated glass was also examined. Thrombin was added (prestimulation) to some suspensions before exposure to the biomaterial surfaces. The three polymeric surfaces were characterized by electron spectroscopy for chemical analysis (ESCA). Prestimulation with thrombin leads to increased adhesion of single platelets only with Silastic. With a wide range of surface types, thrombin prestimulation consistently leads to higher levels of platelet accumulation in the form of aggregates; the PVC-coated material showed the highest levels. ESCA analysis of PVC, however, suggested our coating was impure or an oxidized material.

Biocompatible Materials