PubMed Health⌕ Search

Biomedical subjects

B D Springer

Publications and source records attributed to B D Springer.

2 recordsLinked to original sources

Cauda equina syndrome in ankylosing spondylitis (the CES-AS syndrome): meta-analysis of outcomes after medical and surgical treatments.

The cauda equina syndrome in ankylosing spondylitis (the CES-AS syndrome) is marked by slow, insidious progression and a high incidence of dural ectasia in the lumbosacral spine. A high index of suspicion for this problem must be maintained when evaluating the patient with ankylosing spondylitis with a history of incontinence and neurologic deficit on examination. There has been disagreement in the literature as to whether surgical treatment is warranted for this condition. A meta-analysis was thus performed comparing outcomes with treatment regimens. Our results suggest that leaving these patients untreated or treating with steroids alone is inappropriate. Nonsteroidal antiinflammatory drugs may improve back pain but do not improve neurologic deficit. Surgical treatment of the dural ectasia, either by lumboperitoneal shunting or laminectomy, may improve neurologic dysfunction or halt the progression of neurologic deficit.

Adult↗

The kinematic rotating hinge prosthesis for complex knee arthroplasty.

Fifty-eight patients (69 knees) treated with the Kinematic Rotating Hinged knee prosthesis for complex primary and salvage revision total knee arthroplasty were followed up for an average of 75.2 months (range, 24-199 months). The indications for use of the Kinematic Rotating Hinged knee prosthesis included severe bone loss combined with ligamentous instability (30 knees), nonunion of a periprosthetic fracture (10 knees), an acute periprosthetic fracture (nine knees), severe collateral ligamentous instability (five knees), reimplantation for infection (six knees), nonunion of a supracondylar femoral fracture (four knees), congenital dislocation of the knee (three knees), and treatment of a severely comminuted distal femur (two knees). At the time of surgery, the average patient age was 72 years (range, 46-92 years). Preoperatively, knee extension averaged 4.94 degrees (range, 0 degrees-40 degrees) and flexion averaged 81 degrees (range, 15 degrees-125 degrees). At final followup, knee extension averaged 1.25 degrees (range, -5 degrees-25 degrees) and flexion averaged 94.2 degrees (range, 5 degrees-125 degrees). The preoperative Knee Society Knee score averaged 40.3 points (range, 2-93 points) and improved to 77 points (range, 33-99 points) at final followup. Complications were numerous: 23 (32%) patients experienced at least one complication and 12 (17%) patients had two or more complications. Deep periprosthetic infection was the most common complication (14.5%), followed by patellar complications (13%), and prosthetic component breakage (10%). During the period of this study, there were 15,798 primary and 2673 revision total knee arthroplasties done at the authors' institution. The patients receiving a Kinematic Rotating Hinged knee prosthesis represent a highly complex and small subset (0.37%) of the overall population having knee arthroplasty. Although the use of the Kinematic Rotating Hinged knee prosthesis for these limited indications has been useful for the authors, the incidence of complications and the poor outcome of these complications is disconcerting. Hinged total knee arthroplasty should be reserved for the final salvage option of the treatment options available when doing complex primary and salvage revision knee arthroplasties.

Aged↗