PubMed Health⌕ Search

Biomedical subjects

B De Smedt

Publications and source records attributed to B De Smedt.

9 recordsLinked to original sources

Mathematical disabilities in children with velo-cardio-facial syndrome.

Current neurocognitive theories of number processing [Dehaene, S., Piazza, M., Pinel, P., & Cohen, L. (2003). Three parietal circuits for number processing. Cognitive Neuropsychology, 20, 487-506] state that mathematical performance is made possible by two functionally and anatomically distinct subsystems of number processing: a verbal system located in the angular gyrus, which underlies the retrieval of arithmetic facts, and a quantity system located in the intraparietal sulcus, which subserves operations that involve semantic manipulations of quantity. According to this model, subtypes of math disability (MD) should be traceable to differential impairments in these subsystems. The present study investigated MD in children with velo-cardio-facial syndrome (VCFS) and aimed to verify which of these subsystems of number processing is impaired in these children. Eleven children with VCFS and 11 individually matched controls, selected from the same classes, completed a large battery of mathematical tests. Our data revealed that children with VCFS had preserved number reading abilities and preserved retrieval of arithmetic facts, both of which indicate that the verbal subsystem is not impaired in VCFS. By contrast, children with VCFS showed difficulties in number comparison, the execution of a calculation strategy and word problem solving, all of which involve the semantic manipulation of quantities. This provides evidence for a specific deficit in the quantity subsystem in children with VCFS, suggesting underlying abnormalities in the intraparietal sulcus.

Adolescent↗

Denoising of Monte Carlo dose calculations: smoothing capabilities versus introduction of systematic bias.

In order to evaluate the performance of denoising algorithms applied to Monte Carlo calculated dose distributions, conventional evaluation methods (rms difference, 1% and 2% difference) can be used. However, it is illustrated that these evaluation methods sometimes underestimate the introduction of bias, since possible bias effects are averaged out over the complete dose distribution. In the present work, a new evaluation method is introduced based on a sliding window superimposed on a difference dose distribution (reference dose-noisy/denoised dose). To illustrate its importance, a new denoising technique (ANRT) is presented based upon a combination of the principles of bilateral filtering and Savitzky-Golay filters. This technique is very conservative in order to limit the introduction of bias in high dose gradient regions. ANRT is compared with IRON for three challenging cases, namely an electron and photon beam impinging on heterogeneous phantoms and two IMRT treatment plans of head-and-neck cancer patients to determine the clinical relevance of the obtained results. For the electron beam case, IRON outperforms ANRT concerning the smoothing capabilities, while no differences in systematic bias are observed. However, for the photon beam case, although ANRT and IRON perform equally well on the conventional evaluation tests (rms difference, 1% and 2% difference), IRON clearly introduces much more bias in the penumbral regions while ANRT seems to introduce no bias at all. When applied to the IMRT patient cases, both denoising methods perform equally well regarding smoothing and bias introduction. This is probably caused by the summation of a large set of different beam segments, decreasing dose gradients compared to a single beam. A reduction in calculation time without introducing large systematic bias can shorten a Monte Carlo treatment planning process considerably and is therefore very useful for the initial trial and error phase of the treatment planning process.

Algorithms↗

Mathematical disabilities in young primary school children with velo-cardio-facial syndrome.

The aim of the present study was to examine the previously reported mathematical disabilities (MD) of children with Velo-Cardio-Facial Syndrome (VCFS) in children of a younger age range. Fourteen children with VCFS (aged 6-10 years) participated in this study. These children were individually matched on sex, IQ, age and parental educational level to a control group of peers, selected from the same classes. A broad range of mathematical abilities were assessed, comprising number reading and writing, number comparison, counting, single-digit arithmetic, multidigit arithmetic and word problem solving. Consistent with previous reports, children with VCFS were significantly slower in counting numerosities and they tended to perform more poorly on number comparison. These results indicate that difficulties in low-level number processing in children with VCFS occur already at a very young age. Furthermore, children with VCFS demonstrated preserved retrieval of arithmetic facts, but, in contrast to older children with VCFS, no procedural difficulties in mathematics were observed. Finally, word problem solving appeared to be an important area of weakness, starting already at this young age.

Achievement↗

Decoupling initial electron beam parameters for Monte Carlo photon beam modelling by removing beam-modifying filters from the beam path.

A new method is presented to decouple the parameters of the incident e(-) beam hitting the target of the linear accelerator, which consists essentially in optimizing the agreement between measurements and calculations when the difference filter, which is an additional filter inserted in the linac head to obtain uniform lateral dose-profile curves for the high energy photon beam, and flattening filter are removed from the beam path. This leads to lateral dose-profile curves, which depend only on the mean energy of the incident electron beam, since the effect of the radial intensity distribution of the incident e- beam is negligible when both filters are absent. The location of the primary collimator and the thickness and density of the target are not considered as adjustable parameters, since a satisfactory working Monte Carlo model is obtained for the low energy photon beam (6 MV) of the linac using the same target and primary collimator. This method was applied to conclude that the mean energy of the incident e- beam for the high energy photon beam (18 MV) of our Elekta SLi Plus linac is equal to 14.9 MeV. After optimizing the mean energy, the modelling of the filters, in accordance with the information provided by the manufacturer, can be verified by positioning only one filter in the linac head while the other is removed. It is also demonstrated that the parameter setting for Bremsstrahlung angular sampling in BEAMnrc ('Simple' using the leading term of the Koch and Motz equation or 'KM' using the full equation) leads to different dose-profile curves for the same incident electron energy for the studied 18 MV beam. It is therefore important to perform the calculations in 'KM' mode. Note that both filters are not physically removed from the linac head. All filters remain present in the linac head and are only rotated out of the beam. This makes the described method applicable for practical usage since no recommissioning process is required.

Algorithms↗

Investigation of geometrical and scoring grid resolution for Monte Carlo dose calculations for IMRT.

Monte Carlo based treatment planning of two different patient groups treated with step-and-shoot IMRT (head-and-neck and lung treatments) with different CT resolutions and scoring methods is performed to determine the effect of geometrical and scoring voxel sizes on DVHs and calculation times. Dose scoring is performed in two different ways: directly into geometrical voxels (or in a number of grouped geometrical voxels) or into scoring voxels defined by a separate scoring grid superimposed on the geometrical grid. For the head-and-neck cancer patients, more than 2% difference is noted in the right optical nerve when using voxel dimensions of 4 x 4 x 4 mm3 compared to the reference calculation with 1 x 1 x 2 mm3 voxel dimensions. For the lung cancer patients, 2% difference is noted in the spinal cord when using voxel dimensions of 4 x 4 x 10 mm3 compared to the 1 x 1 x 5 mm3 calculation. An independent scoring grid introduces several advantages. In cases where a relatively high geometrical resolution is required and where the scoring resolution is less important, the number of scoring voxels can be limited while maintaining a high geometrical resolution. This can be achieved either by grouping several geometrical voxels together into scoring voxels or by superimposing a separate scoring grid of spherical voxels with a user-defined radius on the geometrical grid. For the studied lung cancer cases, both methods produce accurate results and introduce a speed increase by a factor of 10-36. In cases where a low geometrical resolution is allowed, but where a high scoring resolution is required, superimposing a separate scoring grid on the geometrical grid allows a reduction in geometrical voxels while maintaining a high scoring resolution. For the studied head-and-neck cancer cases, calculations performed with a geometrical resolution of 2 x 2 x 2 mm3 and a separate scoring grid containing spherical scoring voxels with a radius of 2 mm produce accurate results and introduce a speed increase by a factor of 13. The scoring grid provides an additional degree of freedom for limiting calculation time and memory requirements by selecting optimized scoring and geometrical voxel dimensions in an independent way.

Algorithms↗

The importance of accurate linear accelerator head modelling for IMRT Monte Carlo calculations.

Two Monte Carlo dose engines for radiotherapy treatment planning, namely a beta release of Peregrine and MCDE (Monte Carlo dose engine), were compared with Helax-TMS (collapsed cone superposition convolution) for a head and neck patient for the Elekta SLi plus linear accelerator. Deviations between the beta release of Peregrine and MCDE up to 10% were obtained in the dose volume histogram of the optical chiasm. It was illustrated that the differences are not caused by the particle transport in the patient, but by the modelling of the Elekta SLi plus accelerator head and more specifically the multileaf collimator (MLC). In MCDE two MLC modules (MLCQ and MLCE) were introduced to study the influence of the tongue-and-groove geometry, leaf bank tilt and leakage on the actual dose volume histograms. Differences in integral dose in the optical chiasm up to 3% between the two modules have been obtained. For single small offset beams though the FWHM of lateral profiles obtained with MLCE can differ by more than 1.5 mm from profiles obtained with MLCQ. Therefore, and because the recent version of MLCE is as fast as MLCQ, we advise to use MLCE for modelling the Elekta MLC. Nevertheless there still remains a large difference (up to 10%) between Peregrine and MCDE. By studying small offset beams we have shown that the profiles obtained with Peregrine are shifted, too wide and too flat compared with MCDE and phantom measurements. The overestimated integral doses for small beam segments explain the deviations observed in the dose volume histograms. The Helax-TMS results are in better agreement with MCDE, although deviations exceeding 5% have been observed in the optical chiasm. Monte Carlo dose deviations of more than 10% as found with Peregrine are unacceptable as an influence on the clinical outcome is possible and as the purpose of Monte Carlo treatment planning is to obtain an accuracy of 2%. We would like to emphasize that only the Elekta MLC has been tested in this work, so it is certainly possible that alpha releases of Peregrine provide more accurate results for other accelerators.

Dose-Response Relationship, Radiation↗

DOSSCORE: an accelerated DOSXYZnrc code with an efficient stepping algorithm and scoring grid.

DOSSCORE is an accelerated version of DOSXYZnrc that allows photons to cross voxel boundaries of the same medium and utilizes a separate scoring grid superimposed on the geometrical grid. Two different stepping algorithms, the hownear method and the scaling method are implemented in DOSSCORE. The hownear method allows particles to travel larger distances in homogeneous regions where there is no interest in the dose deposition of these particles, whilst the scaling method utilizes a stepping algorithm in which particles are only slowed down by the boundaries of the geometrical voxels and not by the boundaries of the scoring voxels. For CT-based phantoms, only photon ray tracing is applied, which results in a rather modest speed gain of factor 1.2 compared to DOSXYZnrc. The hownear method and scaling method do not increase the speed for CT-based phantoms, but only for homogeneous phantoms and phantoms with a limited number of small heterogeneities. In cases where a small number of scoring voxels are needed, the hownear method performs better than the scaling method, whilst the opposite is true for cases when many scoring voxels are needed. The photon transport is accelerated by almost a factor of 2 for all phantoms (homogeneous, heterogeneous with much homogeneity and CT-based phantoms) compared to DOSXYZnrc. For a small number of scoring voxels, the hownear method is up to a factor of 2.6 and 1.9 faster than DOSXYZnrc for homogeneous and heterogeneous phantoms in the case of photon beams. For an electron beam, a speed gain of factor 2.4 is obtained. For a full scoring grid like the one used in DOSXYZnrc, the scaling method is up to a factor of 2.2 and 1.7 faster than DOSXYZnrc for homogeneous and heterogeneous phantoms in the case of photon beams. For an electron beam, a speed gain of factor 2 is obtained. A speed increase without biasing the results is very relevant. The use of two separate grids, the more efficient stepping algorithms and the accelerated photon transport can be applied to every EGS-based or other Monte Carlo code.

Algorithms↗

MCDE: a new Monte Carlo dose engine for IMRT.

A new accurate Monte Carlo code for IMRT dose computations, MCDE (Monte Carlo dose engine), is introduced. MCDE is based on BEAMnrc/DOSXYZnrc and consequently the accurate EGSnrc electron transport. DOSXYZnrc is reprogrammed as a component module for BEAMnrc. In this way both codes are interconnected elegantly, while maintaining the BEAM structure and only minimal changes to BEAMnrc.mortran are necessary. The treatment head of the Elekta SLiplus linear accelerator is modelled in detail. CT grids consisting of up to 200 slices of 512 x 512 voxels can be introduced and up to 100 beams can be handled simultaneously. The beams and CT data are imported from the treatment planning system GRATIS via a DICOM interface. To enable the handling of up to 50 x 10(6) voxels the system was programmed in Fortran95 to enable dynamic memory management. All region-dependent arrays (dose, statistics, transport arrays) were redefined. A scoring grid was introduced and superimposed on the geometry grid, to be able to limit the number of scoring voxels. The whole system uses approximately 200 MB of RAM and runs on a PC cluster consisting of 38 1.0 GHz processors. A set of in-house made scripts handle the parallellization and the centralization of the Monte Carlo calculations on a server. As an illustration of MCDE, a clinical example is discussed and compared with collapsed cone convolution calculations. At present, the system is still rather slow and is intended to be a tool for reliable verification of IMRT treatment planning in the case of the presence of tissue inhomogeneities such as air cavities.

Adenocarcinoma↗

Pre-academic and early academic achievement in children with velocardiofacial syndrome (del22q11.2) of borderline or normal intelligence.

School-aged children with del22q11.2 tend to show a typical learning and neuropsychological profile, which is characterised by a VIQ-PIQ discrepancy (in favour of the VIQ) and significantly better scores for reading (decoding) and spelling compared to mathematics. To the best of our knowledge, there exists no systematic research on the pre-academic and early academic skills that might underpin these learning difficulties. The purpose of the current study was to investigate more systematically these pre-academic and early academic skills in borderline to normal intelligent (FSIQ > 70) children with del22q11.2 in the last year of kindergarten and first grade of primary school in Flanders. In the kindergarten group, meta-linguistic awareness and counting skills were examined. In the group of first graders, children were tested on reading, spelling and mathematics. Thirteen children (mean age: 6 years 4 months (SD = 0.84); 9 boys, 4 girls) participated in this study. In the present study, there were no differences in intelligence and academic outcomes between boys and girls, and no differences in IQ and academic achievement between children with cardiac defects or severe velopharyngeal insufficiency (VPI) and children without these deficits. With regard to pre-academic achievement in general, a characteristic profile with clearly better results for meta-linguistic awareness in comparison to counting skills was found, but this difference is not statistically significant. Concerning early academic achievement, children with del22q11.2, as a group, perform (despite their somewhat lower general intelligence) on average compared with their age-related peers. However, at an individual level--especially within the domain of counting skills and mathematics--there is a wide variability, with some children showing remarkable learning difficulties already at an early age.

Belgium↗