PubMed Health⌕ Search

Biomedical subjects

B Deconihout

Publications and source records attributed to B Deconihout.

3 recordsLinked to original sources

Tomographic Atom Probe: New Dimension in Materials Analysis.

: Materials science requires the use of increasingly powerful tools in materials analysis. The last 20 years have witnessed the development of a number of analytical techniques. However, among these techniques, only a few allow observation and analysis of materials at the nanometer level. The tomographic atom probe (TAP) is a three-dimensional atom-probe (3-DAP) developed at the University of Rouen. In this instrument, the specimen is field evaporated, atomic layer by atomic layer, and the use of a position-sensing system makes it possible to map out the chemical identity of individual atoms within each field-evaporated layer on a nearly atomic scale. After analysis, the volume of matter removed from the specimen can be reconstructed atom by atom in the three dimensions of real space. The main advantages of the 3-DAP is its single-atom sensitivity and very high spatial resolution. In addition to 3-D visual information on chemical heterogeneity, 3-D images give an accurate measurement of the composition of any feature without any convolution bias. This study first describes the history of the 3-DAP technique. Its main features and the latest developments of the TAP are then detailed. The performance of this instrument is illustrated through two recent applications in materials science. Possible ways to further improve the technique are also discussed.

Journal Article↗

Effects of incidence angles of ions on the mass resolution of an energy compensated 3D atom probe.

We have used a first-order reflectron lens in an optical tomographic atom probe in order to improve the mass resolution. Calculations have been performed to determine the effect of second-order errors in ion energy and incidence angle on the performance of the lens. By applying a correction procedure based on the results of these calculations, we have been able to improve experimental mass resolution by 30%.

Journal Article↗

Improvement of the mass resolution of the atom probe using a dual counter-electrode.

As compared to other techniques, the mass resolution of the 3D atom probe is rather poor. This low mass resolution derives from the spread in energy of field-evaporated ions. In this work, the single counter-electrode used to remove atoms from the specimen was replaced with a dual counter-electrode. A positive standing voltage V(PA) is applied on the electrode facing the specimen while the second electrode is grounded. As a result, ions experience a post-acceleration between electrodes that lowers energy deficits of ions resulting in an improvement in the mass resolution. This paper reports the study of the resulting improvement in mass resolution as a function of the post-acceleration voltage. It is also shown that, because of the evaporation pulse, ions also undergo a dynamic post-deceleration in the between electrodes. This post-deceleration contributes to the mass resolution increase. Our results show that this very simple device makes it possible to significantly improve the mass resolution of the atom probe. For a low post-acceleration voltage, the mass resolution is 800 FWHM and 200 at full-width tenth-maximum.

Journal Article↗