PubMed Health⌕ Search

Biomedical subjects

B E Bouma

Publications and source records attributed to B E Bouma.

18 recordsLinked to original sources

High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography.

BACKGROUND: Optical coherence tomography is a new, high spatial-resolution, cross-sectional imaging technique. We investigated the ability of optical coherence tomography to provide detailed images of subsurface structures in the upper gastrointestinal (GI) tract. METHODS: Optical coherence tomography was performed during routine upper GI endoscopy on 32 patients including 20 patients with Barrett's esophagus. An endoscopic mucosal biopsy was obtained immediately after imaging and was used for histopathologic correlation. RESULTS: Optical coherence tomography provided clear delineation of layers of the normal human esophagus extending from the epithelium to the longitudinal muscularis propria. Gastric mucosa was differentiated from esophageal mucosa, Barrett's esophagus was differentiated from normal esophageal mucosa, and esophageal adenocarcinoma was distinguished from normal esophagus and Barrett's esophagus. CONCLUSIONS: Optical coherence tomography allows visualization of the subsurface architectural morphology of the upper GI tract. The diagnostic information provided by this new imaging modality suggests that it may be a useful adjunct to endoscopy.

Anatomy, Cross-Sectional↗

High resolution in vivo intra-arterial imaging with optical coherence tomography.

BACKGROUND: Optical coherence tomography (OCT) is a new method of catheter based micron scale imaging. OCT is analogous to ultrasound, measuring the intensity of backreflected infrared light rather than sound waves. OBJECTIVE: To demonstrate the ability of OCT to perform high resolution imaging of arterial tissue in vivo. METHODS: OCT imaging of the abdominal aorta of New Zealand white rabbits was performed using a 2.9 F OCT imaging catheter. Using an ultrashort pulse laser as a light source for imaging, an axial resolution of 10 micrometer was achieved. RESULTS: Imaging was performed at 4 frames/second and data were saved in either super VHS or digital format. Saline injections were required during imaging because of the signal attenuation caused by blood. Microstructure was sharply defined within the arterial wall and correlated with histology. Some motion artefacts were noted at 4 frames/second. CONCLUSIONS: In vivo imaging of the rabbit aorta was demonstrated at a source resolution of 10 micrometer, but required the displacement of blood with saline. The high resolution of OCT allows imaging to be performed near the resolution of histopathology, offering the potential to have an impact both on the identification of high risk plaques and the guidance of interventional procedures.

Animals↗

High resolution imaging of normal and osteoarthritic cartilage with optical coherence tomography.

OBJECTIVE: We describe optical coherence tomography (OCT), a high resolution micron scale imaging technology, for assessment of osteoarthritic articular cartilage microstructure. OCT is analogous to ultrasound, measuring the intensity of backreflected infrared light rather than acoustical waves. METHODS: OCT imaging was performed on over 100 sites on 20 normal and osteoarthritic cartilage specimens in vitro. RESULTS: Microstructures that were identified included fibrillations, fibrosis, cartilage thickness, and new bone growth at resolutions between 5 and 15 microm. In addition, the polarization sensitivity of imaging suggested a diagnostic role of polarization spectroscopy. CONCLUSION: OCT represents an attractive new technology for intraarticular imaging due to its high resolution (greater than any available clinical technology), ability to be integrated into small arthroscopes, compact portable design, and relatively low cost.

Arthrography↗

Two- and three-dimensional high-resolution imaging of the human oviduct with optical coherence tomography.

OBJECTIVE: To evaluate the feasibility of optical coherence tomography, a new method of micron-scale imaging, for high-resolution assessment of the oviduct. Optical coherence tomography is analogous to ultrasound except that it measures the backreflection of infrared light rather than acoustical waves. DESIGN: The ampulla of a human fallopian tube was imaged in vitro using optical coherence tomography. Images were generated in 2 and 3 dimensions. SETTING: University. PATIENT(S): Samples were obtained from women who had undergone hysterectomy for leiomyomatosis. INTERVENTION(S): None MAIN OUTCOME MEASURE(S): The ability to perform imaging on a micron scale, which is a level of resolution higher than that of any currently available clinical technology. RESULT(S): Two- and three-dimensional data sets of the reflectance of a human fallopian tube were acquired. A volume of 5 x 5 x 2.5 mm (length x width x depth) was scanned. The axial resolution was 11 microm, and the lateral resolution at the focus was 20 microm. The data sets showed detailed structures of the fallopian tube. CONCLUSION(S): Our ability to obtain micron-scale two- and three-dimensional images of an in vitro oviduct suggests that it may be possible to identify and surgically treat tubal causes of infertility.

Diagnostic Imaging↗

Optical biopsy in human pancreatobiliary tissue using optical coherence tomography.

Optical coherence tomography (OCT) is a new technique for performing high-resolution, cross-sectional tomographic imaging in human tissue. OCT is analogous to ultrasound B mode imaging except that it uses light rather than acoustical waves. As a result, OCT has over 10 times the resolution of currently available clinical high-resolution cross-sectional imaging technologies. In this work, we investigate the capability of OCT to differentiate the architectural morphology of pancreatobiliary tissues. Normal pancreatobiliary tissues, including the gallbladder, common bile duct, pancreatic duct, and pancreas were taken postmortem and imaged using OCT. Images were compared to corresponding histology to confirm tissue identity. Microstructure was delineated in different tissues, including tissue layers, glands, submucosal microvasculature, and pancreatic islets of Langerhans. The ability of OCT to provide high-resolution imaging of pancreatobiliary architectural morphology suggests the feasibility of using OCT as a powerful diagnostic endoscopic imaging technology to image early stages of pancreatobiliary disease.

Biliary Tract↗

Intraoperative assessment of microsurgery with three-dimensional optical coherence tomography.

PURPOSE: To evaluate three-dimensional optical coherence tomography (OCT) for use in the assessment of the microsurgical anastomoses of vessels and nerves. MATERIALS AND METHODS: OCT is an optical analogue of ultrasonography and is capable of imaging nontransparent biologic tissue by detecting backscattered infrared light. Cross-sectional in vitro images of rabbit and human vessels and nerves were obtained in as little as 125 msec at 10-micron resolution by using a solid-state laser as a light source. A surgical microscope was integrated with OCT to perform simultaneous imaging with en face visualization. Cross-sectional images were assembled to produce three-dimensional reconstructions of microsurgical specimens. RESULTS: Three-dimensional OCT reconstructions depicted the structure within an arterial anastomosis and helped identify sites of luminal obstruction. The longitudinal spatial orientation of individual nerve fascicles was tracked in three dimensions to identify changes in position. In vitro human arteries and nerves embedded in highly scattering tissue and not visible at microscopy were located and imaged with OCT at eight frames per second. CONCLUSION: The three-dimensional, micrometer-scale, diagnostic imaging capabilities of OCT permit rapid feedback for assessment of microsurgical procedures. OCT technology can be readily integrated with surgical microscopes and has potential for intraoperative monitoring to improve patient outcome.

Anastomosis, Surgical↗

High resolution imaging of the upper respiratory tract with optical coherence tomography: a feasibility study.

A need exists in respiratory medicine for a technology capable of identifying airway pathology on a micron scale. This study has demonstrated the feasibility of optical coherence tomography (OCT) for ultrahigh resolution imaging of the upper respiratory tract by in vitro studies of human tissue. OCT is a relatively new technique that can be used to noninvasively collect tomographic images of tissue microstructure with micron-scale resolution. OCT is analogous to ultrasound, measuring the intensity of infrared light rather than acoustical waves. Samples throughout the upper respiratory tract, from the epiglottis to the secondary bronchi, were imaged. The resulting images were compared with histopathology and verified the ability of OCT to delineate relevant structures such as the epithelium, mucosa, cartilage and its sublayers, and glands at a resolution higher than any clinical imaging technology. The ability of OCT to generate image resolution in the range close to that of histopathology in real time, as well as easy integration with small, relatively inexpensive endoscopes, low cost, and lack of a need for a transducing medium, supports the hypothesis that this optical technology could become a powerful modality in the diagnosis and management of a wide range of clinical respiratory pathology.

Feasibility Studies↗

In vivo endoscopic optical biopsy with optical coherence tomography.

Current medical imaging technologies allow visualization of tissue anatomy in the human body at resolutions ranging from 100 micrometers to 1 millimeter. These technologies are generally not sensitive enough to detect early-stage tissue abnormalities associated with diseases such as cancer and atherosclerosis, which require micrometer-scale resolution. Here, optical coherence tomography was adapted to allow high-speed visualization of tissue in a living animal with a catheter-endoscope 1 millimeter in diameter. This method, referred to as "optical biopsy," was used to obtain cross-sectional images of the rabbit gastrointestinal and respiratory tracts at 10-micrometer resolution.

Anatomy, Cross-Sectional↗

Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography.

Studies investigating normal and abnormal cardiac development are frequently limited by an inability to assess cardiovascular function within the intact organism. In this work, optical coherence tomography (OCT), a new method of micron-scale, noninvasive imaging based on the measurement of backscattered infrared light, was introduced for the high resolution assessment of structure and function in the developing Xenopus laevis cardiovascular system. Microstructural details, such as ventricular size and wall positions, were delineated with OCT at 16-microm resolution and correlated with histology. Three-dimensional representation of the cardiovascular system also was achieved by repeated cross-sectional imaging at intervals of 25 microm. In addition to structural information, OCT provides high speed in vivo axial ranging and imaging, allowing quantitative dynamic activity, such as ventricular ejection fraction, to be assessed. The sensitivity of OCT for dynamic assessment was demonstrated with an inotropic agent that altered cardiac function and dimensions. Optical coherence tomography is an attractive new technology for assessing cardiovascular development because of its high resolution, its ability to image through nontransparent structures, and its inexpensive portable design. In vivo and in vitro imaging are performed at a resolution approaching that of histopathology without the need for animal killing.

Animals↗

Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound.

BACKGROUND: OCT can image plaque microstructure at a level of resolution not previously demonstrated with other imaging techniques because it uses infrared light rather than acoustic waves. OBJECTIVES: To compare optical coherence tomography (OCT) and intravascular ultrasound (IVUS) imaging of in vitro atherosclerotic plaques. METHODS: Segments of abdominal aorta were obtained immediately before postmortem examination. Images of 20 sites from five patients were acquired with OCT (operating at an optical wavelength of 1300 nm which was delivered to the sample through an optical fibre) and a 30 MHz ultrasonic transducer. After imaging, the microstructure of the tissue was assessed by routine histological processing. RESULTS: OCT yielded superior structural information in all plaques examined. The mean (SEM) axial resolution of OCT and IVUS imaging was 16 (1) and 110 (7), respectively, as determined by the point spread function from a mirror. Furthermore, the dynamic range of OCT was 109 dB compared with 43 dB for IVUS imaging. CONCLUSIONS: OCT represents a promising new technology for intracoronary imaging because of its high resolution, broad dynamic range, and ability to be delivered through intravascular catheters.

Aorta, Abdominal↗

Optical biopsy in human urologic tissue using optical coherence tomography.

Optical Coherence Tomography (OCT) is a recently developed non-invasive technique for obtaining high resolution, cross-sectional images of human tissue. This work investigated the capability of OCT to differentiate the architectural morphology of urologic tissue with the long term aim of using OCT as an adjunct to endoscopic imaging and to improve the efficiency of interventional procedures such as transurethral prostatectomy (TURP). Urologic tissues were taken postmortem, dissected, and imaged using OCT. Microstructure was delineated in different urologic tissues, including the prostatic urethra, prostate, bladder, and ureter, with an axial resolution of 16 +/- 1 microm., higher than any clinically available endoscopic intraluminal imaging technology. The ability of OCT to provide non-contact high resolution imaging of urologic tissue architectural morphology (i.e. optical biopsy), without the need for excisional biopsy, suggests the potential of using OCT to obtain information on tissue microstructure that could only previously be obtained with conventional biopsy.

Biopsy↗

Optical biopsy in human gastrointestinal tissue using optical coherence tomography.

OBJECTIVES: Optical coherence tomography (OCT) is a new technique for performing high-resolution, cross-sectional tomographic imaging in human tissue. OCT is somewhat analogous to ultrasound B mode imaging except that it uses light rather than acoustical waves. OCT has over 10 times the resolution of currently available clinical high-resolution imaging technologies. In this work, we investigate the capability of OCT to differentiate the architectural morphology of gastrointestinal tissue with the long-term objective of extending OCT to endoscopic based diagnostics. METHODS: Normal and diseased gastrointestinal tissues were taken postmortem and imaged using OCT. Images were compared with corresponding histology to confirm tissue identity and suggest the mechanisms that produce tissue contrast. RESULTS: Microstructure was delineated in different tissues, including the esophagus and colon, at 16 +/- 1 microns resolution, higher than any clinically available cross-sectional imaging technology. Differentiation of tissue layers, such as the mucosa, submucosa, and muscularis were achieved because of their different optical properties. CONCLUSIONS: The ability of OCT to provide high-resolution in situ imaging of gastrointestinal microstructure, without the need for excisional biopsy, suggests the feasibility of using OCT as a powerful diagnostic imaging technology, which can be integrated with conventional endoscopy.

Biopsy↗

Investigation of developing embryonic morphology using optical coherence tomography.

Improved imaging of morphological changes has the potential of offering new insight into the complex process of embryonic development. Optical coherence tomography (OCT) is a new imaging technique for performing in vivo cross-sectional imaging of architectural morphology by measuring backscattered infrared light. This study investigates the application of OCT for imaging developing structure in Rana pipiens, Xenopus laevis, and Brachydanio rerio. Images are compared to conventional histological baselines. Cross-sectional imaging can be performed and structural morphology identified at greater imaging depths than possible with confocal and light microscopy. Repeated OCT imaging may be performed in vivo in order to track structural changes throughout development.

Animals↗

Optical coherence tomography for optical biopsy. Properties and demonstration of vascular pathology.

BACKGROUND: Optical coherence tomography (OCT) is an recently developed medical diagnostic technology that uses back-reflected infrared light to perform in situ micron scale tomographic imaging. In this work, we investigate the ability of OCT to perform micron scale tomographic imaging of the internal microstructure of in vitro atherosclerotic plaques. METHODS AND RESULTS: Aorta and relevant nonvascular tissue were obtained at autopsy. Two-dimensional cross-sectional imaging of the exposed surface of the arterial segments was performed in vitro with OCT. A 1300-nm wavelength, superluminescent diode light source was used that allows an axial spatial resolution of 20 microns. The signal-to-noise ratio was 109 dB. Images were displayed in gray scale or false color, Imaging was performed over 1.5 mm into heavily calcified tissue, and a high contrast was noted between lipid- and water-based constituents, making OCT attractive for intracoronary imaging. The 20-microns axial resolution of OCT allowed small structural details such as the width of intimal caps and the presence of fissures to be determined. The extent of lipid collections, which had a low backscattering intensity, also were well documented. CONCLUSIONS: OCT represents a promising new technology for imaging vascular microstructure with a level of resolution not previously achieved with the use of other imaging modalities. It does not required direct contact with the vessel wall and can be performed with a catheter integrated with a relatively inexpensive optical fiber. The high contrast among tissue constituents, high resolution, and ability to penetrate heavily calcified tissue make OCT an attractive new imaging technology for intracoronary diagnostics.

Arteriosclerosis↗

Imaging developing neural morphology using optical coherence tomography.

Imaging technologies offer numerous possibilities to investigate the processes involved in neural development. The optical coherence tomography (OCT) technology is analogous to ultrasound backscatter microscopy except reflections of light are detected rather than sound. The OCT technology combines high-resolution in vivo imaging in a diode-based benchtop instrument capable of micron-scale resolution in transparent and non-transparent biological specimens. In this paper, we examine the potential of using OCT for the investigation of developing neural morphology. To demonstrate the capabilities of this technique in assessing neural development, we have chosen to image early normal and abnormal neural morphology in a common developmental biology model, Xenopus laevis. In vivo images clearly identify gross and subtle differences in neural structure and may offer an alternative to the costly and time-consuming process of repeated histological preparation for neural developmental studies. Because imaging can be performed rapidly and repeatedly, the morphological changes of single specimens can be followed throughout development. To illustrate the future potential of this technique, a state-of-the-art Cr4+:forsterite modelocked laser is used as a broad bandwidth light source to image individual cells in a developing specimen.

Animals↗