Optimal Response to Cardiac Arrest study: defibrillation waveform effects.

INTRODUCTION: Advances in early defibrillation access, key to the "Chain of Survival", will depend on innovations in defibrillation waveforms, because of their impact on device size and weight. This study compared standard monophasic waveform automatic external defibrillators (AEDs) to an innovative biphasic waveform AED. MATERIAL AND METHODS: Impedance-compensated biphasic truncated exponential (ICBTE) and either monophasic truncated exponential (MTE) or monophasic damped sine (MDS) AEDs were prospectively, randomly assigned by date in four emergency medical services. The study design compared ICBTE with MTE and MDS combined. This subset analysis distinguishes between the two classes of monophasic waveform, MTE and MDS, and compares their performance to each other and to the biphasic waveform, contingent on significant overall effects (ICBTE vs. MTE vs. MDS). Primary endpoint: Defibrillation efficacy with < or =3 shocks. Secondary endpoints: shock efficacy with < or =1 shock, < or =2 shocks, and survival to hospital admission and discharge. Observations included return of spontaneous circulation (ROSC), refibrillation, and time to first shock and to first successful shock. RESULTS: Of 338 out-of-hospital cardiac arrests, 115 had a cardiac aetiology, presented with ventricular fibrillation, and were shocked by an AED. Defibrillation efficacy for the first "stack" of up to 3 shocks, for up to 2 shocks and for the first shock alone was superior for the ICBTE waveform than for either the MTE or the MDS waveform, while there was no difference between the efficacy of MTE and MDS. Time from the beginning of analysis by the AED to the first shock and to the first successful shock was also superior for the ICBTE devices compared to either the MTE or the MDS devices, while again there was no difference between the MTE and MDS devices. More ICBTE patients achieved ROSC pre-hospital than did MTE patients. While the rates of ROSC were identical for MTE and MDS patients, the difference between ICBTE and MDS was not significant. Rates of refibrillation and survival to hospital admission and discharge did not differ among the three populations. CONCLUSIONS: ICBTE was superior to MTE and MDS in defibrillation efficacy and speed and to MTE in ROSC. MTE and MDS did not differ in efficacy. There were no differences among the waveforms in refibrillation or survival.

Adult↗

Multicenter, randomized, controlled trial of 150-J biphasic shocks compared with 200- to 360-J monophasic shocks in the resuscitation of out-of-hospital cardiac arrest victims. Optimized Response to Cardiac Arrest (ORCA) Investigators.

BACKGROUND: In the present study, we compared an automatic external defibrillator (AED) that delivers 150-J biphasic shocks with traditional high-energy (200- to 360-J) monophasic AEDs. METHODS AND RESULTS: AEDs were prospectively randomized according to defibrillation waveform on a daily basis in 4 emergency medical services systems. Defibrillation efficacy, survival to hospital admission and discharge, return of spontaneous circulation, and neurological status at discharge (cerebral performance category) were compared. Of 338 patients with out-of-hospital cardiac arrest, 115 had a cardiac etiology, presented with ventricular fibrillation, and were shocked with an AED. The time from the emergency call to the first shock was 8.9+/-3.0 (mean+/-SD) minutes. CONCLUSIONS: The 150-J biphasic waveform defibrillated at higher rates, resulting in more patients who achieved a return of spontaneous circulation. Although survival rates to hospital admission and discharge did not differ, discharged patients who had been resuscitated with biphasic shocks were more likely to have good cerebral performance.

Adult↗

Electrocardiographic evaluation of defibrillation shocks delivered to out-of-hospital sudden cardiac arrest patients.

OBJECTIVE: Following out-of-hospital defibrillation attempts, electrocardiographic instability challenges accurate assessment of defibrillation efficacy and post-shock rhythm. Presently, there is no precise definition of defibrillation efficacy in the out-of-hospital setting that is consistently used. The objective of this study was to characterize out-of-hospital cardiac arrest rhythms following low-energy biphasic and high-energy monophasic shocks in order to precisely define defibrillation efficacy and establish uniform criteria for the evaluation of shock performance. METHODS: Automatic external defibrillators (AEDs) delivering 150 J impedance-compensating biphasic or 200-360 J monophasic damped sine waveform shocks were observed in a combined police and paramedic program. ECGs from 29 biphasic patients and 87 monophasic patients were classified as organized, asystole or VF at post-shock times of 3, 5, 10, 20 and 60 s. RESULTS: Post-shock time (P<0.0001) and shock waveform type (P = 0.02) affected the classification of post-shock rhythm. At each analysis time, there were more patients in VF following high-energy monophasic shocks than following 150 J biphasic shocks (P<0.0001). The percentage of patients in VF increased with post-shock time. The rate of VF recurrence was not a function of shock type, indicating that refibrillation is largely a function of the patient's underlying cardiac disease. CONCLUSION: Defibrillation should uniformly be defined as termination of VF for a minimum of 5-s after shock delivery. Rhythms should be reported at 5-s after shock delivery to assess early effects of the defibrillation shock and at 60-s after shock delivery to assess the interaction of the defibrillation therapy and factors such as post-shock myocardial dysfunction and the patient's underlying cardiac disease.

Adolescent↗

Biphasic transthoracic defibrillation causes fewer ECG ST-segment changes after shock.

STUDY OBJECTIVE: Electrocardiographic abnormalities are common after transthoracic defibrillation. ECG ST-segment changes are especially problematic after defibrillation and may indicate ischemic or shock-induced cardiac dysfunction after resuscitation. Biphasic defibrillation waveforms, compared with monophasic waveforms, diminish shock-induced cardiac dysfunction in laboratory preparations. This effect has not been validated in human subjects. We therefore evaluated in a prospective, blinded fashion the effect of biphasic and monophasic transthoracic defibrillation on the ECG ST segment in 30 consecutive patients during surgery for the implantation of a cardioverter-defibrillator. METHODS: In each patient two low-energy truncated biphasic transthoracic defibrillation shocks (115 and 130 J) were compared with a standard clinical 200 J monophasic damped-sine wave shock. The biphasic shocks and the damped-sine wave shock have been demonstrated to have equal defibrillation efficacy of 97%. Fifteen-second ECG signals recorded across transthoracic defibrillation electrodes were digitized before ventricular fibrillation induction and immediately after each defibrillation attempt. The ST segments 80 msec after the J point were analyzed in a blinded fashion by two reviewers. The ST-segment deflection, QRS-interval duration, QT interval, and heart rate after each therapy were compared with baseline values. RESULTS: ECG ST-segment elevation was significantly greater with the 200-J damped-sine waveform than with either biphasic waveform. The ECG ST-segment levels were -.55 +/- .36 at baseline, -.76 +/- .36 mm after internal shock, -.02-.36 mm after 115-J biphasic shock, .21 +/- .38 mm after 130-J biphasic shock, and 2.09 +/- .37 mm after 200-J damped-sine wave shock (P<.0001). QRS-interval duration, QT interval, and heart rate did not change significantly with any waveform. CONCLUSION: Transthoracic defibrillation with biphasic waveforms results in less postshock ECG evidence of myocardial dysfunction (injury or ischemia) than standard monophasic damped sine waveforms without compromise of defibrillation efficacy.

Adult↗

Low-energy impedance-compensating biphasic waveforms terminate ventricular fibrillation at high rates in victims of out-of-hospital cardiac arrest. LIFE Investigators.

INTRODUCTION: New automatic external defibrillators (AEDs), which are smaller, lighter, easier to use, and less costly make the goal of widespread AED deployment and early defibrillation for out-of-hospital cardiac arrest feasible. The objective of this study was to observe the performance of a low-energy impedance-compensating biphasic waveform in the out-of-hospital setting on 100 consecutive victims of sudden cardiac arrest. METHODS AND RESULTS: AEDs incorporating a 150-J impedance-compensating biphasic waveform were used by 12 EMS systems. Data were obtained from the AED PC card reporting system. Defibrillation was defined as conversion to an organized rhythm or to asystole. Endpoints included: defibrillation efficacy for ventricular fibrillation (VF); restoration of an organized rhythm at the time of patient transfer to an advanced life support (ALS) team or to the emergency department (ED); and time from AED power-on to first defibrillation. The AED correctly identified 44 of 100 patients presenting in VF as requiring a shock (100% sensitivity) and 56 of 100 patients not in VF as not requiring a shock (100% specificity). The time from 911 call to first shock delivery averaged 8.1 +/- 3.0 minutes. A single 150-J biphasic shock defibrillated the initial VF episode in 39 of 44 (89%) patients. The average time from power-on to first defibrillation was 25 +/- 17 seconds. At patient transfer to ALS or ED care, an organized rhythm was present in 34 of 44 (77%) patients presenting with VF. Asystole was present in 7 (16%) and VF in 3 (7%). CONCLUSIONS: Low-energy impedance-compensating biphasic waveforms terminate long-duration VF at high rates in out-of-hospital cardiac arrest. Use of this waveform allows AED device characteristics consistent with widespread AED deployment and early defibrillation.

Adult↗

Transthoracic defibrillation of swine with monophasic and biphasic waveforms.

BACKGROUND: Biphasic waveforms have had a favorable impact on internal defibrillation but have seen minimal use in transthoracic defibrillation systems. The purpose of this study was to compare monophasic and biphasic waveforms for transthoracic defibrillation in swine. METHODS AND RESULTS: Three interrelated studies were performed in 19 swine to establish the relative transthoracic defibrillation efficacy of biphasic shock waveforms. In study 1, we measured voltage (V50) and energy (E50) strength-duration curves for monophasic and biphasic truncated exponential waveforms. We then independently examined the effects of phase duration and tilt on biphasic waveform defibrillation with a total waveform duration from study 1 that provided the minimum V50 (study 2) and the minimum E50 (study 3). At each pulse duration tested in study 1, biphasic waveforms defibrillated with significantly less voltage and energy than monophasic waveforms. At a duration of 12 ms, there was a voltage minimum for biphasic waveform defibrillation. At this duration, V50 was 1378 +/- 505 V for the biphasic waveform compared with 2185 +/- 361 V for the monophasic waveform, P = .01. For both monophasic and biphasic waveforms, E50 increased with pulse duration. With a total pulse duration of 12 ms, E50 was 169 +/- 101 J for the biphasic waveform compared with 414 +/- 114 J for the monophasic waveform, P = .003. In study 2, optimization of phase duration and total tilt reduced the defibrillation requirements of the 12-ms "minimum voltage" biphasic waveform to 1284 +/- 187 V and 129 +/- 36 J. In study 3, the 8-ms "minimum energy" biphasic waveform had an E50 of 115 +/- 35 J that was 11% less than the 12-ms biphasic waveform, P = .11; however, voltage requirements of 1476 +/- 239 V were 15% higher, P = .005. CONCLUSIONS: This study demonstrates the superiority of truncated biphasic waveforms over truncated monophasic waveforms for transthoracic defibrillation of swine. Biphasic waveforms should prove as advantageous at reducing voltage and energy requirements for transthoracic defibrillation as they have for internal defibrillation.

Animals↗

Truncated biphasic pulses for transthoracic defibrillation.

BACKGROUND: Early defibrillation is the single most important factor for improving out-of-hospital ventricular fibrillation resuscitation rates. To achieve the earlier response times required for survival, typically < 6 minutes from time of collapse, it will be necessary to equip a far wider network of first responders (firefighters, police, and other individuals with responsibility for public safety) with small, lightweight, and inexpensive automatic external defibrillators (AEDs). An important step in reducing the size and cost of AEDs will be to improve defibrillation efficacy. Because biphasic waveform defibrillation has had a favorable impact on implantable cardioverter-defibrillators (ICDs), there are reasons to believe that biphasic waveforms would also improve transthoracic defibrillators. Our purpose, therefore, was to examine the efficacy of two different low-energy biphasic truncated waveforms referenced to a standard damped sine waveform for transthoracic defibrillation in humans. METHODS AND RESULTS: We prospectively and randomly compared the transthoracic defibrillation efficacy of two different truncated biphasic waveforms, 115 J (70 microF) and 130 J (105 microF), with that of a standard 200-J (36-microF, 28-mH) damped sine wave pulse using right anterior and left lateral thoracic pads (R2 Medical Systems) in 30 cardiac arrest survivors during transvenous ICD surgery. The right anterior patch electrode was used as the cathode and the left lateral thoracic pad as the anode. Transthoracic ventricular defibrillation rescue shocks were tested after a failed transvenous defibrillation shock delivered in the course of ICD testing. Each of the three different rescue shocks was tested in random order in each patient. All shocks were delivered at end expiration. The investigators responsible for determining transthoracic shock efficacy were blinded throughout the study to the transthoracic rescue waveform used. A total of 33 patients were considered for study, but three patients failed to satisfy all entry criteria or did not have a sufficient number of ventricular fibrillation inductions to allow for testing of all three waveforms. Percent efficacy for the three waveforms was then compared in the 30 patients who satisfied entry criteria and completed the protocol. The study population had a mean age of 61 +/- 11 years, with 22 (73%) being men. The mean left ventricular ejection fraction was 0.39 +/- 0.14. Coronary artery disease was present in 22 (73%). The 115-J (70-microF) biphasic pulse, the 130-J (105-microF) biphasic pulse, and the 200-J (36-microF, 28-mH) damped sine wave pulse were equally effective, resulting in a 97% first-shock ventricular defibrillation efficacy rate. Each waveform failed to defibrillate once, with each waveform failing in a different patient. CONCLUSIONS: The results of this study suggest that biphasic truncated transthoracic shocks of low energy (115 and 130 J) are as effective as 200-J damped sine wave shocks used in standard transthoracic defibrillators. This finding may contribute significantly to the miniaturization and cost reduction of transthoracic defibrillators, which could enable the development of a new generation of AEDs appropriate for an expanded group of out-of-hospital first responders and, eventually, layperson use.

Adult↗

The defibrillation success rate versus energy relationship: Part I--Curve fitting and the most efficient defibrillation energy.

The effect of applying an energy pulse to the heart during ventricular fibrillation is described by the probability of successful defibrillation or success rate. Seven to ten (8.60 +/- 0.84: mean +/- standard deviation) defibrillation trials per energy were randomly attempted at energies which span the defibrillation success rate versus energy curve. We obtained 70.0 +/- 8.4 episodes per dog. We fit the defibrillation success rate versus energy relationship from ten dogs (20.5 +/- 1.5 kg) to four types of curves: linear, exponential, probit transformed linear, and logit transformed linear. The correlation coefficients for each fit are 0.917 +/- 0.057, 0.944 +/- 0.014, 0.926 +/- 0.51, and 0.889 +/- 0.098, respectively. We therefore conclude that the exponential curve best describes the DSRE relationship. This suggests the existence of an energy below which defibrillation does not occur. At higher energies, the exponential curve asymptotically approaches a 100% success rate, which indicates that increasing the energy produces a diminishing benefit to defibrillation success rate. The estimated energies with a 0% defibrillation success rate are surprisingly consistent among dogs, with 2.072 +/- 0.553 J. The estimated energy with an 80% defibrillation success rate is 5.217 +/- 1.091 J. The estimated defibrillation success rate corresponding to the defibrillation threshold of 3.59 +/- 1.06 J is consistent with 0.516 +/- 0.144. The estimated energies with a 0% success rate correlate well with the defibrillation thresholds with R = 0.772; P = 0.0088. Since implantable defibrillators have a limited energy supply, we determined energy efficiency by dividing defibrillation success rate by the applied energy and energy consumption by dividing the applied energy by the defibrillation success rate. The most efficient defibrillation energy occurs at the maximum energy efficiency and the minimum energy consumption. The most efficient defibrillation energy of 4.34 +/- 0.97 J determined from the exponential fit has a success rate of 0.70 +/- 0.06. The most efficient defibrillation energy can be predicted from the defibrillation threshold. Clinically, a 70% success rate may not be adequate. We, therefore, compared the energy efficiency and consumption of energies with 90% and 95% success rates to the most efficient defibrillation energy. About a 50% increase in energy from the most efficient defibrillation energy is necessary for a 90% success rate which results in about a 13% loss in energy efficiency and about a 16% increase in energy consumption. About an 84% energy increase is necessary for a 95% success rate which results in about a 24% loss in energy efficiency and about a 33% increase in energy consumption.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

The defibrillation success rate versus energy relationship: Part II--Estimation with the "bootstrap".

Seventy or so defibrillation trials were typically attempted to determine the relationship between defibrillation success rate and energy (DSRE). Clinically, it may be desirable to estimate the DSRE relationship with fewer trials. We used the statistical resampling technique called the "bootstrap" to determine the number of defibrillation trials necessary for an accurate estimation of the DSRE relationship. The bootstrap technique assumes that the observed database is the maximum likelihood sample of the estimated population. The observed database is repeatedly resampled to produce a large bootstrap data-base and the bootstrap best estimate of a statistic is determined. DSRE data were obtained from ten dogs (20.5 +/- 1.5 kg). We bootstrapped our experimental DSRE data by two methods: (1) randomly choosing with replacement a specified number of defibrillation trials per energy; and (2) randomly choosing with replacement a specified number of defibrillation trials per bootstrap replication. For both bootstrap techniques, 100 replications were made. We performed a linear regression analysis on the bootstrap success rates and the observed success rates determined from 71.0 +/- 6.8 defibrillation attempts from each of the ten dogs. We concluded that 28 defibrillation trials are necessary to estimate the observed DSRE relationship with a correlation coefficient of 0.95.

Animals↗

Success rate versus defibrillation energy: temporal profile and the most efficient defibrillation threshold.

To determine the temporal profile of the energy requirement for defibrillation, shocks were delivered to canine hearts after 5, 10, or 20 seconds from the onset of fibrillation with a combination of patch and catheter electrodes. A total of 956 fibrillation-defibrillation sequences were performed at one of four energy levels appropriately selected for each period of fibrillation in 10 anesthetized dogs. The energy values related to 50% (E50) and 80% (E80) of the predicted success were calculated from a logistic regression curve. The E50 and E80 values at 10 seconds after the onset of fibrillation were less than those at 20 seconds after the onset by 7.1% +/- 18.3% and 9.7% +/- 21.4%, respectively; differences were not significant. At 5 seconds after the onset, the differences were 15.3% +/- 14.2% (p less than 0.02) and 16.4% +/- 12.7% (p less than 0.01), respectively. The defibrillation energy efficiency was assessed by dividing the success rate (SR) of fibrillation by the applied energy (E). The maximal SR/E at 5, 10, and 20 seconds of fibrillation was achieved at the energy corresponding to the SRs of 88.8% +/- 4.5%, 90.4% +/- 3.9%, and 88.1% +/- 4.6%, respectively. We conclude that the energy requirement for defibrillation increases with the duration of fibrillation, even shortly after the onset of fibrillation, and the maximal energy efficiency is attained at the energy associated with the SR of approximately 90%.

Animals↗

The effect of an unsuccessful subthreshold shock on the energy requirement for the subsequent defibrillation.

The effect of an unsuccessful subthreshold shock on the energy requirement for the subsequent defibrillation was studied in 10 anesthetized dogs. Defibrillation was achieved with a spring catheter electrode in the superior vena cava and a patch electrode on the anteroapical ventricular wall. Success rates of defibrillation 20 seconds from the onset of ventricular fibrillation were determined at three energy levels with and without a preceding subthreshold shock. Altogether, 637 episodes of fibrillation-defibrillation were performed (63.7 +/- 6.7 per dog). Predicted energy levels for defibrillation success rates of 50% and 80% (E50 and E80) acquired from a logistic regression curve were 0.0303 +/- 0.0064 and 0.0367 +/- 0.0069 joule/gm, respectively, without subthreshold shocks. E50 and E80 with an unsuccessful subthreshold shock resulted in comparable values (E50: 0.0325 +/- 0.0041 joule/gm; E80: 0.0.380 +/- 0.0100 joule/gm). Our results suggest that an unsuccessful low-energy shock does not alter the energy requirement for subsequent defibrillation with an implantable defibrillator.

Animals↗

Treatment of out-of-hospital cardiac arrest with a low-energy impedance-compensating biphasic waveform automatic external defibrillator. The LIFE Investigators.

Few victims of sudden cardiac arrest survive. A new generation of automatic external defibrillators (AEDs), smaller, lighter, easier to use, and less costly, makes the goal of widespread AED deployment and early defibrillation feasible. A low-energy impedance-compensating biphasic waveform allows AED device characteristics more suitable to the goal of early defibrillation than high-energy waveforms. This study observed the performance of such a biphasic waveform in the out-of-hospital setting on 100 consecutive victims of sudden cardiac arrest treated by a wide range of first-responders. AEDs incorporating 150-J impedance-compensating biphasic waveforms were placed into service of 34 EMS systems. Data were obtained from the AED PC data card-recording system. The first endpoint was to determine the effectiveness of this waveform in terminating ventricular fibrillation (VF). The second endpoint was to determine whether or not the use of such an AED culminated in an organized rhythm at the time of patient transfer to an advanced life support (ALS) team or emergency department (ED). The third endpoint was to assess the efficiency of the human-factors design of the AED by measuring user time intervals. The 34 sites provided data from 286 consecutive AED uses, 100 from SCA victims with VF as their initial rhythm upon attachment of the AED. All 286 patients were correctly identified by the AED as requiring a shock (100% sensitivity for the 100 VF patients) or not (100% specificity to the 186 patients not presenting in VF). Times from emergency call to first shock delivery averaged 9.1 +/- 7.3 minutes. A single 150-J biphasic shock defibrillated the initial VF episode in 86% of patients. For all 450 episodes of VF in these 100 patients, an average of 86% +/- 24% of VF episodes were terminated with a single biphasic shock. Of the 449 VF episodes that received up to three shocks, 97% +/- 11% were terminated with three shocks or fewer. The average number of shocks per VF episode was 1.3 +/- 0.7. The average time from AED power-on and pads attached to first defibrillation was 25 +/- 23 sec. At the time of patient transfer, an organized rhythm was present in 65% of the VF patients; asystole was the result in 25%, and VF was in progress in 10%. It is concluded that low-energy impedance-compensating biphasic waveforms terminate long-duration VF at high rates in out-of-hospital cardiac arrest and provide defibrillation rates exceeding those previously achieved with high-energy shocks. Use of this waveform allows AED device characteristics consistent with widespread AED deployment and early defibrillation.

Automation↗