PubMed Health⌕ Search

Biomedical subjects

B E Van Beers

Publications and source records attributed to B E Van Beers.

At least 19 recordsLinked to original sources

Analysis of contrast-enhanced MR images to assess renal function.

The image analysis and kinetic modeling methods used in dynamic contrast-enhanced magnetic resonance imaging of the kidney are reviewed. Image analysis includes various techniques of coregistration and segmentation. Few methods have been completely implemented. Nevertheless, the use of coregistration may become a standard to decrease the effect of motion on abdominal images and improve the quality of the renal signals. Kinetic models are classified into three categories: enhancement-based, external and internal representations. Enhancement-based representations are limited to a basic analysis of the tracer concentration curves in the kidneys. Their relationship to the underlying physiology is complex and undefined. However, they can be used to evaluate the split renal function. External representations assess the kidney input and output. An external representation based on the up-slope of the renal enhancement to calculate the renal perfusion is commonly used because of its simplicity. In contrast, external representation based on deconvolution or identification methods remain underexploited. For glomerular filtration, an internal representation based on a two-compartmental model is mostly used. Internal representations based on multi-compartmental models describe the renal function in a more realistic way. Because of their numerical complexity, these models remain rarely used.

Glomerular Filtration Rate↗

Calculation of the renal perfusion and glomerular filtration rate from the renal impulse response obtained with MRI.

The aim of this study was to assess the importance of deconvolution for the calculation of renal perfusion and glomerular filtration rate (GFR) on the basis of concentration-time curves as measured with perfusion MRI. Six rabbits were scanned dynamically after injection of a gadolinium chelate. Concentration-time curves were generated by manually drawing regions of interest in the aorta and the renal cortex. To remove the dependency on the arterial input function, a regularized structured total least-squares deconvolution algorithm was used to calculate the renal impulse response. This curve was fitted by the sum of two gamma variate functions, corresponding to the passage of the contrast agent in the glomeruli and the proximal convoluted tubules. Tracer kinetics models were applied to these two functions to obtain the renal perfusion and GFR. For comparison, these two parameters were also calculated on the basis of the renal concentration-time curve before deconvolution. The renal perfusion values correlated well (r = 0.9, P = 0.014) with the values calculated by a validated upslope method. The GFR values correlated well (r = 0.9, P = 0.014) with the values obtained from the clearance of (51)Cr-EDTA. A comparison of the values obtained with and without deconvolution demonstrated the necessity of deconvolution.

Algorithms↗

[Imaging of intestinal ischemia].

Ischemic bowel disease includes acute and chronic mesenteric ischemia, and colon ischemia. Cross-sectional imaging, and more particularly computed tomography, has an increasing role in the detection of acute and chronic mesenteric ischemia. Vascular obstructions or stenoses and changes in the bowel wall can be observed. Functional information can be added with MRI by using sequences that are sensitive to oxygen saturation in the superior mesenteric vein. Arteriography remains the reference examination in patients with acute mesenteric ischemia.

Acute Disease↗

Focal bowel wall changes detected with colour Doppler ultrasound: diagnostic value in acute non-diverticular diseases of the colon.

We performed a study to determine if colour Doppler findings may help to identify the cause of wall thickening in acute non-diverticular diseases of the colon. The study group included 66 patients admitted to the emergency department with a final diagnosis of infectious colitis (n=23), inflammatory colitis (n=10), ischaemic colitis (n=23) and malignant tumours (n=10). The following ultrasound features were assessed: maximal wall thickness, wall stratification, arterial flow in the colonic wall and arteriolar resistive index. Higher values of wall thickness were observed in malignant tumour (18.2+/-6.2 mm, p<0.001). Moderately thickened wall (6.6+/-1.3 mm, p< or =0.06), preserved stratification (90% versus 46% in the remainder of the study population) and lower resistive index (0.51+/-0.10, p< or =0.05) were significantly related to inflammatory colitis. Absence of arterial flow was more frequently observed in ischaemia (43% versus 12% in the remainder of the study population). In conclusion, despite some overlap, both ultrasound and colour Doppler features are helpful in the differential diagnosis of colonic thickening related to non-diverticular colonic lesions.

Acute Disease↗

[Cardiac imaging by means of four-detector row computed tomography and cardiac gating].

Electrocardiographically-assisted imaging is a recent development in multislice spiral computed tomography. In this article, we summarize the principles of four-detector row CT for cardiac applications. Following is an overview of the potential of this technique to evaluate the heart, the thoracic aorta, and the paracardiac pulmonary parenchyma. Technical considerations for optimal imaging are highlighted.

Aorta, Thoracic↗

Assessment of hepatic perfusion parameters with dynamic MRI.

Quantification of hepatic perfusion parameters greatly contributes to the assessment of liver function. The purpose of this study was to describe and validate the use of dynamic MRI for the noninvasive assessment of hepatic perfusion parameters. The signal from a fast T(1)-weighted spoiled gradient-echo sequence preceded by a nonslice-selective 90 degrees pulse and a spoiler gradient was calibrated in vitro with tubes filled with various gadolinium concentrations. Dynamic images of the liver were obtained after intravenous bolus administration of 0.05 mmol/kg of Gd-DOTA in rabbits with normal liver function. Hepatic, aortic, and portal venous signal intensities were converted to Gd-DOTA concentrations according to the in vitro calibration curve and fitted with a dual-input one-compartmental model. With MRI, hepatic blood flow was 100 +/- 35 mL min(-1) 100 mL(-1), the arterial fraction 24 +/- 11%, the distribution volume 13.0 +/- 3.7%, and the mean transit time 8.9 +/- 4.1 sec. A linear relationship was observed between perfusion values obtained with MRI and with radiolabeled microspheres (r = 0.93 for hepatic blood flow [P < 0.001], r = 0.79 for arterial blood flow [P = 0.01], and r = 0.91 for portal blood flow [P < 0.001]). Our results indicate that hepatic perfusion parameters can be assessed with dynamic MRI and compartmental modeling.

Animals↗

Biodistribution of ultrasmall iron oxide particles in the rat liver.

Ferumoxtran, an ultrasmall superparamagnetic iron oxide particle, can be located in several tissue compartments in the liver, namely the extracellular space (blood and interstitium), reticuloendothelial cells, and possibly hepatocytes. To better understand the compartmental distribution of ferumoxtran in the liver, we performed a longitudinal study in the rat using microscopy and magnetic resonance imaging. At light microscopy, no substantial cellular uptake of ferumoxtran was observed before one hour after injection. With a dose of 15 micromol Fe/kg, the number of ferumoxtran particles in the reticuloendothelial cells peaked between one and four hours and with a 150 micromol Fe/kg dose, it peaked between eight and 24 hours. Within hepatocytes, only sparse particles were observed with electron microscopy, at a dose of 150 micromol Fe/kg. Imaging performed up until one hour after ferumoxtran injection showed a significant increase in liver signal intensity on T1-weighted images. These results suggest that ferumoxtran mainly acts as an extracellular agent for at least one hour in the rat and that reticuloendothelial accumulation peaks at later time points. Substantial uptake within hepatocytes did not occur.

Animals↗

Epiploic appendagitis: color Doppler sonographic findings.

The aim of this study was to analyze the color Doppler sonographic findings in primary epiploic appendagitis. Color Doppler sonographic findings of ten patients with primary epiploic appendagitis were reviewed. The following sonographic features were analyzed: identification of a mass adjacent to the colonic wall; identification of spotty color areas with arterial flow in this mass and detection of abnormalities of the colonic wall adjacent to the infiltrated fatty tissue. A well-delineated hyperechoic mass adjacent to the colonic wall was detected in each patient with sonography. No colonic wall abnormalities were observed nor color Doppler signal in and around the hyperechoic area. Absence of flow at color Doppler sonography is an additional feature of epiploic appendagitis.

Abdomen, Acute↗

Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity.

OBJECTIVE: The aim of our study was to determine if hepatic perfusion parameters measured with CT change in relation to disease severity in patients with chronic liver disease. SUBJECTS AND METHODS: Dynamic contrast-enhanced single-section CT scans of the liver were obtained in 40 individuals who included six control subjects, 16 patients with noncirrhotic chronic liver disease, and 18 patients with cirrhosis. Hepatic, aortic, and portal venous time-density curves were fitted to a dual-input one-compartment model to calculate the liver perfusion, arterial fraction, distribution volume, and mean transit time. RESULTS: Liver perfusion decreased in patients with cirrhosis (67 +/- 23 mL. min(-1). 100 mL(-1) versus 108 +/- 34 mL. min(-1). 100 mL(-1) in control subjects [p = 0.009] and 98 +/- 36 mL. min(-1). 100 mL(-1) in patients with noncirrhotic chronic liver disease [p = 0.003]), and the arterial fraction and the mean transit time increased (41 +/- 27% and 51 +/- 79 sec versus 17 +/- 16% and 16 +/- 5 sec in control subjects, and 19 +/- 6% and 17 +/- 8 sec in patients with noncirrhotic chronic liver disease [p < 0.05]). A significant correlation was seen between these three perfusion parameters and the severity of chronic liver disease based on clinical and biologic data (p < 0.001). No significant change in distribution volume was observed. CONCLUSION: Hepatic perfusion parameters measured with CT were significantly altered in cirrhosis and correlated with the severity of chronic liver disease.

Case-Control Studies↗

Value of multislice helical CT scans and maximum-intensity-projection images to improve detection of ureteral stones at abdominal radiography.

OBJECTIVE: The purpose of this study was to assess the improvement in the detection of ureteral stones on abdominal radiographs when the stones were viewed on multislice helical CT scans and maximum-intensity-projection (MIP) images. SUBJECTS AND METHODS: The study included 72 patients with renal colic who underwent abdominal radiography and multislice helical CT. For each patient, a frontal MIP image was generated, and the stone, when present, was marked with a cross on the transverse CT scan. The cross appeared automatically on the corresponding MIP image. The CT examination was used as the standard of reference. The presence and location of ureteral stones on the abdominal radiographs were assessed during three interpretation sessions. In the first session, the abdominal radiographs were viewed alone. In the second, they were viewed with the transverse CT scans. In the third, the abdominal radiographs were viewed with the CT scans and the MIP images. RESULTS: Ureteral stones were present in 58 patients. The percentage of stones detected on the abdominal radiographs was 45% when the radiographs were viewed alone, 66% when they were viewed with the CT scans (p = 0.002 vs radiographs alone), and 78% when viewed with the CT scans and MIP images (p = 0.016 vs radiographs with CT scans). CONCLUSION: The sensitivity of stone detection on abdominal radiographs was greatest when the interpreters viewed the radiographs in conjunction with the CT scans and MIP images.

Adult↗

Gadolinium-enhanced arterial-phase MR imaging of hypervascular liver tumors: comparison between tailored and fixed scanning delays in the same patients.

The purpose of this study was to compare in the same patients tailored and fixed scanning delays during gadolinium-enhanced arterial-phase magnetic resonance imaging of hypervascular liver tumors. Tailored scanning delays were obtained with automated region of interest threshold triggering. A delay of 23 seconds between the start of contrast material injection and imaging was used for fixed delay examinations. Quantitative and qualitative evaluation was performed in 21 patients with normal cardiac function referred for MR assessment of hypervascular liver tumors. In the tailored examinations, the median time delay between the start of contrast material injection and the start of magnetic resonance imaging was 21 seconds (range, 18-34 seconds). The median tumor-to-liver contrast during tailored examinations was 19.1 versus 14.7 during fixed delay examinations. This difference, however, was not significant. Similarly, the enhancement in the aorta, the portal vein, the liver, and the tumor did not differ significantly between examinations performed with tailored and fixed delays. It is concluded that in our group of patients with hypervascular liver tumors and normal cardiac function, no significant improvement in tumor-to-liver contrast and enhancement during the arterial phase was found when gadolinium-enhanced magnetic resonance imaging was performed with a tailored scanning delay rather than with a fixed delay.

Adult↗

Angiomyolipoma of the liver: ferumoxides-enhanced MR imaging.

We report a case of angiomyolipoma of the liver with emphasis on the appearance at MRI after administration of ferumoxides. Post-contrast T1- and T2-weighted images showed a frank decrease of signal intensity in a rim on the margin of the tumor. This unusual finding was related to the presence of an increased number of CD68-positive histiocytic cells in the periphery of the lesion and in the adjacent liver parenchyma.

Angiomyolipoma↗

Extrahepatic biliary obstruction: magnetic resonance imaging compared with endoscopic ultrasonography.

BACKGROUND AND STUDY AIMS: The aim of this study was to compare prospectively the diagnostic efficacy of magnetic resonance (MR) imaging and endoscopic ultrasonography (EUS) in extrahepatic biliary obstruction. PATIENTS AND METHODS: A total of 50 patients with suspected benign or malignant extrahepatic biliary obstruction underwent MR imaging, including MR cholangiopancreatography, and EUS, within a median time delay of 1 day. The final diagnosis was established by endoscopic retrograde cholangiopancreatography in 37 cases, intraoperative cholangiography in nine cases, and clinical and biochemical follow-up in four cases. RESULTS: In total, 33 patients had extrahepatic biliary obstruction, of benign origin in 21 cases and of malignant origin in 12 cases, whereas 17 had no evidence of obstruction. The sensitivity and specificity of MR imaging were 91% and 94 %, respectively. There were one false-positive and three false-negative results, all related to choledochal sludge. The corresponding values for EUS were 97% and 88%. There were two false-positive results and one false-negative result. False-positive diagnoses were related to the presumed presence of biliary sludge and choledocholithiasis, whereas the false-negative diagnosis occurred in one patient with a final diagnosis of sludge. No significant difference in sensitivity and specificity was observed between the two imaging methods (P>0.05). CONCLUSION: In our study MR imaging was as accurate as EUS in the diagnosis of extrahepatic biliary obstruction.

Adolescent↗

Pancreaticopleural fistula: diagnosis with magnetic resonance pancreatography.

Pancreaticopleural fistula secondary to chronic pancreatitis is a rare cause of recurrent pleural effusion. The demonstration of the fistula with endoscopic retrograde pancreatography and CT is invasive or limited. We report in two patients the use of magnetic resonance pancreatography as a noninvasive alternative to endoscopic retrograde pancreatography for the diagnosis of pancreaticopleural fistula.

Adult↗

Prognosis of ischemic colitis: comparison of color doppler sonography with early clinical and laboratory findings.

OBJECTIVE: The objective of this study was to compare the value of color Doppler sonography with early clinical and laboratory findings in determining the prognosis of patients with ischemic colitis. SUBJECTS AND METHODS: We reviewed the early clinical, laboratory, and color Doppler sonographic data of 24 patients with ischemic colitis. The patients were divided into two groups on the basis of their outcome. The first group comprised the patients with transient ischemia who recovered uneventfully, and the second group included the patients who needed surgery because of symptomatic transmural colic gangrene or colic stricture. Clinical data and laboratory values were compared with color Doppler sonographic findings including colic wall thickness, presence of stratification, and arterial flow in the bowel wall. RESULTS: At univariate analysis, increased age (p = 0.007), leukocyte count (p = 0.030), lactate dehydrogenase level (p = 0.030), blood lactate level (p = 0.041), and absence of vascular flow in the colic wall (p<0.001) were significantly related to complicated ischemic colitis. At multivariate analysis, absence of arterial flow was the only significant predictor of complicated ischemic colitis (p = 0.002), with a sensitivity of 82%, a specificity of 92%, a positive predictive value of 90%, and a negative predictive value of 86%. CONCLUSION: Absence of arterial flow in the wall of the ischemic colon on initial color Doppler sonography is suggestive of an unfavorable outcome and is more closely associated with outcome than early clinical and laboratory findings.

Aged↗

Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model.

Various liver diseases lead to significant alterations of the hepatic microcirculation. Therefore, quantification of hepatic perfusion has the potential to improve the assessment and management of liver diseases. Most methods used to quantify liver perfusion are invasive or controversial. This paper describes and validates a non-invasive method for the quantification of liver perfusion using computed tomography (CT). Dynamic single-section CT of the liver was performed after intravenous bolus administration of a low-molecular-mass iodinated contrast agent. Hepatic, aortic and portal-venous time-density curves were fitted with a dual-input one-compartmental model to calculate liver perfusion. Validation studies consisted of simultaneous measurements of hepatic perfusion with CT and with radiolabelled microspheres in rabbits at rest and after adenosine infusion. The feasibility and reproducibility of the CT method in humans was assessed by three observers in 10 patients without liver disease. In rabbits, significant correlations were observed between perfusion measurements obtained with CT and with microspheres (r=0.92 for total liver perfusion, r=0.81 for arterial perfusion and r=0.85 for portal perfusion). In patients, total liver plasma perfusion measured with CT was 112+/-28 ml.min(-1).100 ml(-1), arterial plasma perfusion was 18+/-12 ml.min(-1).100 ml(-1) and portal plasma perfusion was 93+/-31 ml.min(-1).100 ml(-1). The measurements obtained by the three observers were not significantly different from each other (P>0.1). Our results indicate that dynamic CT combined with a dual-input one-compartmental model provides a valid and reliable method for the non-invasive quantification of perfusion in the normal liver.

Adult↗