PubMed Health⌕ Search

Biomedical subjects

B Fartash

Publications and source records attributed to B Fartash.

10 recordsLinked to original sources

Surface-dimpled commercially pure titanium implant and bone ingrowth.

The purpose of this investigation was to examine the effect of the surface macrostructure of a dimpled commercially pure titanium (cp Ti) implant on bone ingrowth in vivo by means of histological examination and a push-out test. Cylindrical implants were inserted in one femur of each experimental rabbit and the animals were killed at 1.5, 3 and 13 months after implantation. The femur with the implant of each animal was then examined in a push-out test. The fracture surfaces of the bone-implant interface after the push-out test were examined under light and electron microscopy. It seems that the dimpled cp Ti surface results in the increased retention of the cp Ti implant in bone due to interlocking between vital bone and the dimples.

Animals↗

Markers of inflammation in crevicular fluid from peri-implant mucosa surrounding single crystal sapphire implants.

The 19 patients included in this study had all been successfully treated for total or partial edentulism with single crystal sapphire implants as retention for overdentures or fixed bridges. As there is a need for more reliable non-invasive parameters for detecting changes surrounding endosseous implants, the aim of this study was to assess the content and the activity of neutrophils in crevicular fluid samples from 3 categories of sites: (1) crevices around implants from edentulous patients (2) crevices around implants in partially edentulous patients, and (3) crevices surrounding teeth. Fluid samples were taken with paper strips from 9 partially edentulous and 10 edentulous patients and the volume measured with a Periotron 6000. Elastase activity was measured as a marker of neutrophil activity and lactoferrin concentration as a marker of the number of neutrophils. Elastase activity per microliter and lactoferrin concentration was, despite similar clinical and radiographic signs, significantly higher in samples from crevices surrounding teeth and implants in the partially edentulous patients compared to samples from crevices around implants in the totally edentulous patients. There were no differences between teeth and implants in partially edentulous patients. The increased elastase activity and lactoferrin concentration indicates a higher neutrophil activity in patients with remaining teeth.

Adult↗

Long-term evaluation of single crystal sapphire implants as abutments in fixed prosthodontics.

49 patients participated in a prospective study of treatment of total or partial edentulism with fixed prosthodontics supported by Bioceram sapphire implants. 15 patients were treated for maxillary or mandibular edentulism, and 7 for a missing maxillary anterior tooth. The remaining 27 patients, with Applegate-Kennedy Class I-IV residual dentitions, were treated with fixed bridges supported by free-standing implants, or bridges supported by teeth and implants. Implant success, prosthesis stability, radiographic marginal bone level as well as parameters for peri-implant health were evaluated. The study began in 1982, and clinical treatment of the last patients was completed in 1988, i.e., a follow-up period ranging from 7 to 13 years. Of the patients treated for total mandibular edentulism, one implant fractured after 6 years in situ. The bone implant score (BIS) values for those implants were at the time for the bridge cementation 63.5 +/- 1.4 and at 1, 2, 3 and 5 year follow-ups 62.1 +/- 1.4, 61.9 +/- 1.5, 61.5 +/- 1.6, and 60.95 +/- 1.3, respectively. The success rate was 100%, 100% and 97.7% for the mandible at 3, 5 and 10 years, respectively. Of the 7 edentulous patients treated with maxillary fixed bridges, 6 implants in 1 patient had to be removed after 1 year in service. Another 2 patients lost all their implants, 6 each, after 36 months. 6 implants in the 4th patient did not fulfil the criteria for success and were rated as failures at the four year follow-up. The success rate was thus 58.1%, 44.2% and 44.2% for the maxilla at 3, 5 and 10 year follow-ups, respectively. Of the 7 patients in whom single missing teeth were replaced, 1 implant in the premolar region was lost during the 1st year post-operatively, but no other complications or changes in BIS were observed. Of the 27 patients treated for partial edentulism (56 implants total) 1 implant, of a 4-unit free standing maxillary bridge fractured after 6 years and was later replaced. There were no statistically significant differences in BIS changes for the implants when used as abutments for partial maxillary or mandibular edentulism. The cumulative success rates for the implants in the partially maxilla were 96.3, 92.6 and 92.6 at the 3, 5 and 10 years respectively and 100% in the mandible over the whole period.

Adult↗

Stability of hydroxyapatite-coatings on titanium oral implants (IMZ). 2 retrieved cases.

2 hydroxyapatite(HA)-coated titanium oral implants (IMZ) were retrieved from 2 patients after more than three years in clinical function. One implant (case I) was removed because of extensive bone resorption and loss of integration, and the other (case II) was retrieved due to fracture of the abutment in sprit of clinical rigidity. The implants and the surrounding soft (case I) and hard (case II) tissues were examined histologically and by scanning electron microscopy (SEM). In case I, the HA-coating was almost degraded, as SEM revealed a resulted rough titanium surface. Histology showed HA particles and inflammation were seen near the implant. In Case II, the HA-coating seemed to be intact and bonded to bone, but scattered HA particles, embedded in bone at a distance from the implant were also observed. The results indicate that HA-coatings may come loose during clinical function. The long-term stability of HA-coatings and the clinical indications for HA-coated implants warrant further study.

Adult↗

Histological characteristics of peri-implant mucosa around Brånemark and single-crystal sapphire implants.

Soft tissues surrounding Brånemark titanium implants and single crystal sapphire implants were studied by conventional light- and transmission electron microscopy and by immunohistochemical markers for cytokeratin, protein S-100, Factor VIII and KP1. Histological sections of biopsies obtained from clinically healthy peri-implant mucosa were separated into a keratinized outer implant epithelium and an inner, non-keratinized epithelium, both immunoreactive towards cytokeratin. The inner implant epithelium terminated in a junctional epithelium, apically not a few cell layers thick. The cells adjacent to the implant showed a condensed cytoplasm, resembling hemidesmosomes. In the underlying connective tissue, rich in fibroblasts and factor VIII immunoreactive blood vessels, the bundles of collagen ran in different directions. S-100 immunoreactive nerve structures were more frequently found beneath the outer than the inner implant epithelium. Inflammatory cell infiltrates, some KP1 positive, were observed in the apical parts of the inner implant epithelium. S-100 positive Langerhans' cells were present mainly within the the outer implant epithelium. For the two implant systems, the techniques disclosed no qualitative structural differences in the adjacent soft tissues.

Aluminum Oxide↗

Rehabilitation of mandibular edentulism by single crystal sapphire implants and overdentures: 3-12 year results in 86 patients. A dual center international study.

86 patients, in 2 Scandinavian centers, participated in a prospective study of mandibular edentulism, treated with overdentures supported by Bioceram sapphire implants. Implant success and prosthesis stability as well as parameters for peri-implant health were evaluated. Masticatory function and complications were also documented. The study began in 1991 and clinical treatment of the last patients was completed in 1991. The patients have been followed for at least 3 years, and up to 12 years. 4 patients were lost to follow-up. Of the initial 324 implants, 7 implants failed before prosthetic treatment. 3 patients lost 1 implant each within the 1st year, and 4 patients lost all 4 implants. 16 implants were lost between 36 and 42 months in function, due to lack of osseointegration and pain. The loss of implants could be attributable to an association, not statistically verified, between bone quality and anatomy, with heavy smoking as a risk factor. Based on the remaining implants, the cumulative implant success rates were 95.2%, 91.3%, 91.3%, 91.3% at 3, 5, 10 and 12 year follow-up respectively. The cumulative success rates for overdentures were 96.4%, 92.8% and 92.8% respectively, for the same follow-up periods. Indices for the health of the peri-implant mucosa disclosed no serious inflammatory reactions in the surrounding soft tissues. Patient satisfaction with this form of oral rehabilitation was high in all but 2 patients who experienced discomfort.

Aluminum Oxide↗

Hydroxyapatite-alumina composites and bone-bonding.

Hydroxyapatite-alumina (HA/Al2O3) composites, with HA contents of 15, 25, 30 and 70, and pure HA as well as pure Al2O3, were densified at 1275 degrees C at a top pressure of 200 MPa for 2 h, using glass-encapsulated hot isostatic pressing. From the sintered ceramics, cylinders 2.8 x 6 mm2 were prepared by ultrasonic machining and implanted into the femoral cortical bones of 12 New Zealand White rabbits for 3 months. After killing the animals, the femur was dissected out and cut into three sections, each containing one cylinder. The specimens were mounted in a push-out device and force was applied along the long axis of the cylinder. The maximum force required to loosen the implant was recorded and the fracture surface of the bone implant was studied by scanning electron microscopy (SEM). The results indicate the important role of HA in new bone apposition to the implants, reflected by increasing bonding strength with increasing HA content in the composites. However, the relationship between HA content and the bonding strength was not linear. The composite with 70% HA and the pure HA ceramic had the same level of bonding strength and similar fracture interfaces in SEM, which supports the high bonding strength detected (about 15 MPa). Fractures occurred both in the bone and in the implant, indicating the stress transfer ability of the contact zone. This study presents qualitatively and quantitatively HA-dependent characteristics in bone-bonding. The mechanical strength of the composites was measured by a three-point bending test. The bending strength of the materials decreases with increasing HA content.

Aluminum Oxide↗

Mandibular single crystal sapphire implants: changes in crestal bone levels over three years.

A total of 190 single crystal sapphire implants, 85 short (4S9S) and 105 long (4S9L), were monitored with panoramic and intraoral radiographs for 3 years. The implants were used as abutments for overdentures in edentulous mandibles in 51 patients. Within the first year, 2 patients lost one implant each due to pain and lack of osseointegration. Neither was replaced and the superstructures remained stable. At baseline registration, i.e., immediately after the prosthetic installation, the bone height relative to the length of the implant was calculated. The mean bone implant score (BIS) was 63.55 +/- 1.34% (mean +/- SE). BIS decreased during the first year 62.18 +/- 1.51%. At the 2- and 3-year recordings, the mean BIS were 61.81 +/- 1.58% and 61.73 +/- 1.63%, respectively. There were no statistically significant differences in BIS changes over the 3-year period or between men and women. The decrease in mean BIS was greater for implants in the premolar region than in the incisor region and for short implants than for long implants.

Adult↗

Histology of tissues surrounding single crystal sapphire endosseous dental implants: an experimental study in the beagle dog.

9 single crystal sapphire dental implants were installed bilaterally into pre-extracted areas in the lower jaw of two beagle dogs and histologically analysed after 180 days in situ. 8 implants were stable and radiographs disclosed complete bone healing. Light-, scanning- and transmission electron microscopy demonstrated that the stable implants were surrounded by a mineralizing bone boundary and a mucosa nearly free from inflammatory cell infiltrations. The 9th implant was mobile and surrounded by a non-mineralized connective tissue capsule containing bundles of collagen. The ultrastructure of the mucosa surrounding the implants closely resembled the mucosa surrounding the tooth. Histometric analysis of the alveolar bone surrounding the stable implants revealed that the value of the bone contact surface ranged from 37.1% to 86.9% (mean value 61.8%) at the light microscopic level.

Alveolar Process↗

In vitro and in vivo experimental studies on single crystal sapphire dental implants.

Successful attachment of the oral tissues to an endosseous dental implant relies in part on its chemical stability, nontoxic properties and maintenance of normal cell functions in the surrounding tissues. The aim of this study was therefore to investigate these 3 factors experimentally. The corrosion resistance of single crystal sapphire (alpha-Al2O3) implants was analysed with respect to the release of aluminium ions; no ions could be detected in the test solutions. The influence of single crystal sapphire on the behaviour of human epithelial cells and fibroblasts derived from biopsies of the oral mucosa, was studied. The cells were cultured in chemically defined or in low serum-containing media. Compared to the corresponding control cultures, no effects on cell morphology and growth characteristics were observed. Sapphire rods were inserted subcutaneously into rats and tissue responses were examined after 4, 8 and 12 weeks post-implantation. None or slight reactions were found in the tissues. The combined evaluation of these experimental approaches indicates that single crystal sapphire is a material well suited for biological implantation.

Aluminum Oxide↗