PubMed Health⌕ Search

Biomedical subjects

B G Celler

Publications and source records attributed to B G Celler.

At least 19 recordsLinked to original sources

Classification of basic daily movements using a triaxial accelerometer.

A generic framework for the automated classification of human movements using an accelerometry monitoring system is introduced. The framework was structured around a binary decision tree in which movements were divided into classes and subclasses at different hierarchical levels. General distinctions between movements were applied in the top levels, and successively more detailed subclassifications were made in the lower levels of the tree. The structure was modular and flexible: parts of the tree could be reordered, pruned or extended, without the remainder of the tree being affected. This framework was used to develop a classifier to identify basic movements from the signals obtained from a single, waist-mounted triaxial accelerometer. The movements were first divided into activity and rest. The activities were classified as falls, walking, transition between postural orientations, or other movement. The postural orientations during rest were classified as sitting, standing or lying. In controlled laboratory studies in which 26 normal, healthy subjects carried out a set of basic movements, the sensitivity of every classification exceeded 87%, and the specificity exceeded 94%; the overall accuracy of the system, measured as the number of correct classifications across all levels of the hierarchy, was a sensitivity of 97.7% and a specificity of 98.7% over a data set of 1309 movements.

Acceleration↗

Detection of daily physical activities using a triaxial accelerometer.

Triaxial accelerometers have been employed to monitor human movements in a variety of circumstances. The study considered the use of data from a single waist-mounted triaxial accelerometer to distinguish between activity states and rest A method using acceleration magnitude was applied to data collected from 26 normal subjects performing sit-to-stand and stand-to-sit transitions and walking. The effects of three parameters were investigated: the length n of a smoothing median filter, the width w of the averaging window used to process the signal and the value of the acceleration magnitude threshold th. These were found to be inter-related, and sets of parameters that resulted in accurate discrimination were determined by the relationship between th and the product of w and n, and by the relationship between n and w. The subjects were randomly divided into control (N = 13) and test (N = 13) groups. Optimum parameter sets were determined using the control group. Eleven sets of parameters yielded the same optimum results of a sensitivity of 1.0 and a specificity of 0.96 in the control group. Upon application to the test group, using these parameters, the system successfully distinguished between activity and rest, giving sensitivities greater than 0.98 and specificities between 0.88 and 0.94.

Acceleration↗

Phase response of model sinoatrial node cells.

When a brief current pulse is incident on excitable cells in cardiac and other nervous tissue, a change in phase of the cell's response is usually observed. In cardiac tissue, the cells are exposed to external stimulation of mainly positive currents, which depolarize the cells. We performed a systematic study of the effect of depolarizing stimuli, covering timing, magnitude, and duration, and demonstrated that all of these parameters influence the phase response of the cell. The phase response of our model cell compares favorably with measurements on isolated sinoatrial node cells. We investigated the phase response to single depolarizing stimuli as a function of the stimulus parameters (phase response curves), and then studied cell responses to the combined effect of a pulse train (entrainment phenomena). The range of magnitudes and durations for the stimuli were 0.01-5 nA and 0.01-50 ms. Comparisons of the entrainment properties of the model with experimental results show good agreement with similar modes and different entrainment ratios occurring for similar basic cycle lengths (as functions of the unperturbed cell period). Our results demonstrate that any combination of parameters that provide the same charge transfer to the cell causes a similar phase response, independent of the specific magnitude and duration for the entire range of stimuli investigated.

Action Potentials↗

Vagal entrainment of heart rate is simulated by an integrator with feedback.

Paradoxical stable entrainment of heart rate to inhibitory vagal impulses can be simulated with two distinct mathematical models; a complex ionic current model of sinoatrial node pacemaker activity, as well as a simple integrator with non-linear feedback. We show that both models exhibit similar entrainment characteristics to repetitive vagal stimuli. By applying a sharp disturbance to each model whilst entrained, the subsequent path of cycle length recovery can be described by dynamic phase response curves and phase-phase plots, the properties of which dictate whether stable entrainment is possible.

Feedback↗

Inhomogeneity of action potential waveshape assists frequency entrainment of cardiac pacemaker cells.

In this paper, we have employed ionic models of sinoatrial node cells to investigate the synchronization of a pair of coupled cardiac pacemaker cells from central and peripheral regions of the sinoatrial node. The free-running cycle length of the cell models was perturbed using two independent techniques and the minimum coupling conductance required to achieve frequency entrainment was used to assess the relative ease with which various cell pairs achieve entrainment. The factors effecting entrainment were further investigated using single-cell models paced with an artificial biphasic coupling current. Our simulation results suggest that dissimilar cell types, those with largely different upstroke velocities entrain more easily, that is, they require less coupling conductance to achieve 1:1 frequency entrainment. We, therefore, propose that regional variation in action-potential waveshape within the sinoatrial node assists frequency synchronization in vivo.

Action Potentials↗

The potential impact of home telecare on clinical practice.

Home telecare, in which the health status of patients at home is monitored remotely, has the potential to improve care and reduce costs. Its widespread implementation would require fundamental changes in the healthcare system.

Activities of Daily Living↗

A web-based approach for electrocardiogram monitoring in the home.

A Web-based electrocardiogram (ECG) monitoring service in which a longitudinal clinical record is used for management of patients, is described. The Web application is used to collect clinical data from the patient's home. A database on the server acts as a central repository where this clinical information is stored. A Web browser provides access to the patient's records and ECG data. We discuss the technologies used to automate the retrieval and storage of clinical data from a patient database, and the recording and reviewing of clinical measurement data. On the client's Web browser, ActiveX controls embedded in the Web pages provide a link between the various components including the Web server, Web page, the specialised client side ECG review and acquisition software, and the local file system. The ActiveX controls also implement FTP functions to retrieve and submit clinical data to and from the server. An intelligent software agent on the server is activated whenever new ECG data is sent from the home. The agent compares historical data with newly acquired data. Using this method, an optimum patient care strategy can be evaluated, a summarised report along with reminders and suggestions for action is sent to the doctor and patient by email.

Data Collection↗

Information technology in primary health care.

Appropriate application of information technology in primary health care will extend traditional diagnosis and patient management beyond the doctor's clinic into the everyday living environment. We describe a model of information management in primary health care, and place special emphasis on the emerging areas of clinical decision support, computerised clinical measurements, patient education and network connectivity. Briefly discussed is the design of innovative home monitoring techniques and a telemedicine based communications infrastructure that should improve access to high quality primary health care for all citizens, irrespective of their distance from major urban centres. A preliminary design for a telemedicine-assisted primary health care network is presented, based on this model of information management. The premise is that improvements in health care services and reductions in health care costs can be effected by establishing a continuum of patient care from the patient's home, to the doctor's surgery, to speciality services in hospitals and to other service providers in the health care sector. While, the proposal focuses on new opportunities arising from the imminent introduction of broad band interactive fibre optic networks throughout Australia, the technology and projected data transfers could easily be handled in the short-term using modem access to the standard telephone network. A simple connectivity scheme for system integration is also presented.

Computer Systems↗

Review of ionic models of vagal-cardiac pacemaker control.

Mathematical models of ion currents in pacemaker cells of the heart and their associated modulation by vagal stimulation have provided numerous insights into the ionic mechanisms underlying parasympathetic control of heart rate. In this article, ionic models described in the literature are reviewed and compared, with a view to examining their effectiveness in reproducing known chronotropic responses to vagal stimulation.

Computer Simulation↗

Vagal control of sinoatrial rhythm: a mathematical model.

The ionic mechanisms underlying vagal control of the cardiac pacemaker were investigated using a new single cell mathematical model of sinoatrial node electrical activity. The model was formulated from a wide range of electrophysiological data available in the literature, with particular reference to whole cell recordings from enzymatically isolated sinoatrial node cells. Development of the model was prompted by the lack of an existing physiologically accurate formulation of sinoatrial node activity that could reproduce the known complex chronotropic response of the pacemaker to brief-burst vagal stimulation, as observed in whole animal and isolated sinus node preparations. Features of the model include the dynamic modulation of the hyperpolarisation-activated current (i(f)) and the L-type calcium current (iCa,L) by acetylcholine, the improved characterisation of the muscarinic potassium current (iK,ACh), assigning the entire background potassium current (ib,K) to spontaneous openings of its channels, and the utilisation of second order kinetics for acetylcholine within the neuroeffector junction. Simulations performed using brief vagal stimuli elicited a strong hyperpolarisation of the membrane which prolonged the cycle in which it was delivered in a phase-dependent manner. This phase-dependency was presented in the form of a standard phase response curve which was characterised by a positive linear slope region, a breakpoint characteristic and a "no effect" zone in which the vagal pulse could no longer prolong the cycle. The breakpoint was manifested as a discontinuity in the curve which was examined by bracketing this point at the limit of the double precision arithmetic employed. At these boundary points on either side of the breakpoint, the vagal stimulus was able to activate outward iK,ACh in such a manner as to finely balance the increasing inward iCa,L trying to generate phase 0 upstroke. On decay of iK,ACh, the membrane either subsequently repolarised or fired to produce an action potential depending on the precise phase of the stimulus. The positive linear slope portion of the PRC was characterised by a strong resetting type behaviour in which the membrane hyperpolarised to approximately the same value, irrespective of the phase of stimulus delivery. For vagal stimulus bursts applied throughout the "no effect" zone, outward iK,ACh was not sufficiently activated in order to overcome the strong inward drive of iCa,L and could not prevent upstroke occurring. For these vagal stimuli, the subsequent cycle was hyperpolarised and prolonged. The size of the "no effect" zone was directly related to the inherent latency incorporated in the activation characteristic of iK,ACh. In contrast to previous models of vagal pacemaker control, our new model was able to reproduce the classical triphasic chronotropic response to brief vagal stimulation characterised by a primary inhibition response, a postinhibitory rebound and a secondary inhibition response. In particular, the postinhibitory rebound was due to activation of the inward hyperpolarisation-activated current by the vagally-induced membrane hyperpolarisation, whilst the secondary inhibition phase resulted from the inhibition of the hyperpolarisation-activated current by acetylcholine. The model suggests that the complex chronotropic responses of the cardiac pacemaker to brief vagal stimulation arises from inherent ionic mechanisms operating within the sinoatrial node.

Acetylcholine↗

Analysis of the dynamics of renal vascular resistance and urine flow rate in the cat following electrical stimulation of the renal nerves.

In ten sino aortic denervated, vagotomized and aneasthetized cats, renal efferent nerves were stimulated for 30 s with trains of constant current pulses at frequencies in the range 5-30 Hz. The arterial pressure, heart rate, urine flow rate (electronic drop counter) and renal blood flow (electromagnetic technique) were recorded. Subsequent computer processing gave the true means of renal artery pressure (MRAP) and renal blood flow (MRBF) and hence the renal vascular resistance (MRVR), over each cardiac cycle. Recovery of MRVR after the end of stimulation exhibited two distinct time constants. The fast component had a time constant of 2.03 +/- 0.26 s and represented 60.2 +/- 1.71% of the recovery. The time constant of the slower component was 14.1 +/- 1.9 s and represented 36.0 +/- 1.6% of the recovery. The relationship between MRVR and stimulus frequency was sigmoidal with maximum sensitivity at stimulus frequencies of 12.6 +/- 0.76 Hz. Changes in urine flow rate, in contrast, followed a hyperbolic function with maximum response sensitivity occurring at very low stimulus frequencies. Changes in urine flow rate were 50% complete at stimulus frequencies of 5 Hz. Identification of two distinct components in the relaxation phase of renal vascular resistance leads to a reasonable hypothesis that 60% of total renal vascular resistance may lie proximal to the glomerulus, whereas 36% may be accounted for by the efferent arterioles.

Anesthesia↗

Remote monitoring of health status of the elderly at home. A multidisciplinary project on aging at the University of New South Wales.

This paper discusses the design and implementation of a multidisciplinary research project and associated field trials to test the hypothesis that functional health status amongst the elderly can be accurately determined remotely by continuously monitoring relatively simple parameters that measure the interaction between participants and their environment. In this study we propose that changes in such simple measures as mobility, sleep patterns, and utilisation of cooking, washing and toilet facilities, can identify changes in functional health status. One of the primary end goals of the project will be to automatically prompt appropriate, timely and cost-effective intervention of medical and community based services to help reduce morbidity and maintain an independent high quality of life for the elderly. Targeted intervention will diminish the demand for high cost medical services. This will have large potential economic implications in helping to contain and reduce the increasing cost of providing health care services to the aged.

Activities of Daily Living↗

Remote home monitoring of health status of the elderly.

The hypothesis that functional health status amongst the elderly can be accurately determined remotely by continuously monitoring relatively simple parameters that measure the interaction between the participant and his or her environment was examined. Changes in such simple measures as mobility, sleep patterns, utilization of cooking, washing, and toilet facilities can identify changes in functional health status and prompt appropriate, timely, and cost-effective intervention of medical and community-based services to help reduce morbidity and maintain an independent, high quality of life. We discuss the design and implementation of a multidisciplinary research project and an associated field trial to unobtrusively monitor and correlate interaction with the home environment and functional health status.

Activities of Daily Living↗

Implementation of a clinical workstation for general practice.

It is now well recognized that achieving international best practice in the primary health sector will require the development of methods based on a fundamental integration of communications and information technologies with clinical practice. This will have far reaching effects, both on the pattern of medical practice and domiciliary care and on patient outcomes. In the past, information and communications technology has been presented as a tool for management, rather than as a tool for supporting, improving, and making more efficient the professional practice of medicine and the delivery of health care to the patient and the community. In this paper, we propose that an essential element for the achievement of international best practice in the health sector is the development and widespread use of information, measurement, and communications technology targeted towards the clinical practice of medicine, the provision of health services and domiciliary care in the community, and the analysis of morbidity patterns and health care outcomes. A key element of this strategy is the development of an integrated Clinical Workstation specifically designed for the general practitioner, practice nurses, and domiciliary care nurses in their professional tasks of measurement, diagnosis, management, and delivery of health care to the community. We will present our work on the design of an integrated Clinical Workstation for Primary Health Care. The Workstation is Windows based, has a sophisticated user interface, and supports a wide range of computing platforms, from desktop to laptop to hand-held notebook computers. The Workstation will be modular and expandable, both in its software and hardware components, so that users may select only those modules appropriate to their own roles, clinical practice, and levels of expertise. The design will focus on the provision of clinical services and will integrate the following key components: Patient records and basic practice management; Clinical records. Based on ICD10, ICPC, or Read Code classifications; Clinical measurements. Blood pressure, spirometry, ECG, and basic hematology and biochemistry; Clinical decision support. Based on epidemiologic data, protocols, and medical expert systems; Domiciliary care and evaluation of the functional health status of the elderly; Communications and networks. Wireless LAN, modem, and fax; Clinical reporting. Morbidity profiles prescribing profiles, and laboratory services and procedures. Implementation of these requirements will ultimately take the form of an untethered, portable notepad computer supporting a communications link via modem, LAN, or wireless LAN, and removable instrumentation and clinical measurement modules.

Computer Systems↗

Dynamics of cardiac period responses after prolonged vagal stimulation in the dog.

In 12 dogs anesthetised with alpha-chloralose and urethane, and beta-adrenergic blocked with propranolol, the cervical vagi were stimulated for 60 seconds with supramaximal constant current pulses at frequencies between 2.0 and 10 Hz. The time course of the recovery of the cardiac period response, after cessation of vagal stimulation, was analyzed using nonlinear curve fitting techniques. It was found that the recovery phase could be reliably fitted with a function consisting of the sum of up to three exponential terms. The first term has a moderate rate constant of 0.2260 +/- 0.0112 S-1 (SE) and is independent of vagal stimulus frequency and the preceding bradycardia. We propose that this term is associated with a recovery from the bradycardia with a rate constant indicative of the reduction of acetylcholine at the pacemaker caused by hydrolysis and washout. The second term has a small rate constant of 0.0499 +/- 0.0014 s-1 (SE) and a negative gain. This term describes the time course of the post vagal tachycardia observed at cessation of stimulation. It is also independent of stimulus frequency and the preceding bradycardia. The third term has a large and variable rate constant (range: 0.247-8.01 s-1) and becomes increasingly dominant when the preceding bradycardia is large. We propose that this third component arises from a rapid return of the pacemaker focus to the dominant location prior to vagal stimulation. The mathematical characterisation of this component is important to permit the accurate derivation of the time courses of the remaining two components. Curvilinear relationships exist between the gain parameters for each of the exponential terms and the preceding bradycardia.

Acetylcholine↗

Pre- and postganglionic sympathetic activity in splanchnic nerves of rats.

Integrated sympathetic activity was recorded on anterior or posterior divisions of the greater splanchnic nerve (GSN) in anesthetized, acutely spinalized, artificially respired Wistar rats before and after ganglionic blockade by hexamethonium. Focal electrical stimulation of spinal sympathoexcitatory pathways elicited large increases in splanchnic sympathetic activity. Ganglionic blockade showed that the anterior and posterior divisions of the GSN are predominantly preganglionic and postganglionic, respectively. Histological examination of excised splanchnic nerves and sympathetic chains indicated that splanchnic postganglionic cell bodies must lie in the chain ganglia rather than within the GSN. Postganglionic responses were calculated for each rat by subtracting responses recorded after ganglionic blockade from responses recorded before ganglionic blockade. As expected, postganglionic responses exhibited longer onset latencies than preganglionic responses. However, evoked activity increased and decreased more rapidly in postganglionic fibers than in preganglionic fibers. Responses to stimulus trains were also better maintained in postganglionic than in preganglionic fibers.

Animals↗