PubMed HealthSearch

Biomedical subjects

B G De Grooth

Publications and source records attributed to B G De Grooth.

13 recordsLinked to original sources

Comparative atomic force and scanning electron microscopy: an investigation on fenestrated endothelial cells in vitro.

Rat liver sinusoidal endothelial cells (LEC) contain fenestrae, which are clustered in sieve plates. Fenestrae control the exchange of fluids, solutes and particles between the sinusoidal blood and the space of Disse, which at its back side is flanked by the microvillous surface of the parenchymal cells. The surface of LEC can optimally be imaged by by scanning electron microscopy (SEM), and SEM images can be used to study dynamic changes in fenestrae by comparing fixed specimens subjected to different experimental conditions. Unfortunately, the SEM allows only investigation of fixed, dried and coated specimens. Recently, the use of atomic force microscopy (AFM) was introduced for analysing the cell surface, independent of complicated preparations techniques. We used the AFM for the investigation of cultured LEC surfaces and the study of morphological changes of fenestrae. SEM served as a conventional reference. AFM images of LEC show structures that correlate well with SEM images. Dried-coated, dried-uncoated and wet-fixed LEC show a central bulging nucleus and flat fenestrated cellular processes. It was also possible to obtain height information which is not available in SEM. After treatment with ethanol or serotonin the diameters of fenestrae increased (+6%) and decreased (-15%), respectively. The same alterations of fenestrae could be distinguished by measuring AFM images of dried-coated, dried-uncoated and wet-fixed LEC. Comparison of dried-coated (SEM) and wet-fixed (AFM) fenestrae indicated a mean shrinkage of 20% in SEM preparations. In conclusion, high-resolution imaging with AFM of the cell surface of cultured LEC can be performed on dried-coated, dried-uncoated and wet-fixed LEC, which was hitherto only possible with fixed, dried and coated preparations in SEM and transmission electron microscopy (TEM).

Animals

Lissajous-like patterns in scatter plots of calibration beads.

Flow cytometric measurements of light scattering of polystyrene calibration beads revealed remarkable Lissajous-like loops in two-parameter scatter plots. The existence of such loops is shown to be in qualitative agreement with Lorenz-Mie scattering theory of homogeneous spheres. The occurrence of these patterns reflects the extreme particle size dependency of perpendicular light scattering of homogeneous spheres. These effects may give an explanation for the frequently observed phenomenon that polystyrene spheres reveal a relatively large CV in the perpendicular light scattering signals, whereas the CV of the forward light scattering signal is small. We conclude that one should be careful to optimize the perpendicular light scattering channel by minimizing the CV, because there is no linear relationship between instrument alignment quality and the CV of the perpendicular light scattering signals of calibration beads.

Calibration

Visible diode lasers can be used for flow cytometric immunofluorescence and DNA analysis.

This report describes a feasibility study concerning the use of a visible diode laser for two important fluorescence applications in a flow cytometer. With a 3 mW 635 nm diode laser, we performed immunofluorescence measurements using the fluorophore allophycocyanin (APC). We have measured CD8 positive lymphocytes with a two-step labeling procedure and the resulting histograms showed good separation between the negative cells and the dim and the bright fluorescent subpopulations. As a second fluorescence application, we chose DNA analysis with the recently developed DNA/RNA stains TOTO-3 and TO-PRO-3. In our setup TO-PRO-3 yielded the best results with a CV of 3.4%. Our results indicate that a few milliwatts of 635 nm light from a visible diode laser is sufficient to do single color immunofluorescence measurements with allophycocyanin and DNA analysis with TO-PRO-3. The major advantages of using a diode laser in a flow cytometer are the small size, the low price, the high efficiency, and the long lifetime.

DNA

Flow cytometric measurement of [Ca2+]i and pHi in conjugated natural killer cells and K562 target cells during the cytotoxic process.

We describe a flow cytometric assay that enables one to follow conjugate formation between cytotoxic cells and their target cells during the cytotoxic process. In addition, the internal calcium concentration ([Ca2+]i) and internal pH (pHi) of the conjugated cells can be monitored and directly compared to the nonconjugated cells. This is achieved by labeling one cell type with the Ca(2+)-specific dye Fluo-3, while the other cell type is labeled with the pH-sensitive dye SNARF-1. As these fluorochromes have different emission spectra, events positive for both fluorochromes are identified as conjugates. The results show that the conjugates can be clearly distinguished from single cytotoxic cells [natural killer (NK) cells] and target cells [K562 cells, (TC)]. Upon binding, [Ca2+]i is increased in the NK cells as well as in the TC. In conjugated NK cells this increase of [Ca2+]i is temperature dependent and is followed by a decrease to a normal [Ca2+]i value later on. The [Ca2+]i in NK cells increases in 2 steps, which may be related to the binding--and lethal hit phase. Upon conjugate formation, NK cells show a slight increase in pHi (0.2-0.3 pH units). TC do not reveal a significant change in pHi.

Aniline Compounds

Detection of in situ hybridization to human chromosomes with the atomic force microscope.

Atomic force microscopy (AFM) permits one to generate a topographic representation of the sample under investigation with high spatial resolution. We assumed that cytochemical staining techniques, which yield reaction products which can be discriminated from the surrounding material on basis of their topographic properties, would be applicable in AFM. Here we show the validity of this assumption by employing an in situ hybridization technique in which the final label was the precipitated product of a peroxidase/diaminebenzidine reaction. After hybridization of the DNA probe pUC1.77 that recognizes the heterochromatic region of human chromosome 1 (1q12), the AFM clearly detects the sites of in situ hybridization. In situ hybridization with DNA probe p1-79 results in clear marking of the telomere region 1p36. The diameter of the probe p1-79 linked reaction product was 75-100 nm, indicating that resolution of 200 nm can readily be reached with this AFM approach of DNA mapping. This precision is directly linked with the amount of precipitated material.

Chromosomes, Human

White blood cell differentiation using a solid state flow cytometer.

A flow cytometer using a solid state light source and detector was designed and built. For illumination of the sample stream two types of diode lasers (670 nm and 780 nm) were tested in a set-up designed to differentiate human leukocytes by means of light scattering. The detector is an avalanche photodiode, which was used to detect the weak scattered light in the orthogonal direction. The new flow cytometer set-up is very small, relatively cheap and yields similar results as a standard flow cytometer set-up using a helium-neon laser and photomultipliers.

Cell Differentiation

Cluster analysis of flow cytometric list mode data on a personal computer.

A cluster analysis algorithm, dedicated to analysis of flow cytometric data is described. The algorithm is written in Pascal and implemented on an MS-DOS personal computer. It uses k-means, initialized with a large number of seed points, followed by a modified nearest neighbor technique to reduce the large number of subclusters. Thus we combine the advantage of the k-means (speed) with that of the nearest neighbor technique (accuracy). In order to achieve a rapid analysis, no complex data transformations such as principal components analysis were used. Results of the cluster analysis on both real and artificial flow cytometric data are presented and discussed. The results show that it is possible to get very good cluster analysis partitions, which compare favorably with manually gated analysis in both time and in reliability, using a personal computer.

Algorithms

High-resolution imaging of chromosome-related structures by atomic force microscopy.

An atomic force microscope (AFM) was combined with a conventional optical microscope. The optical microscope proved to be very convenient for locating objects of interest. In addition, the high-resolution AFM image can be compared directly with the traditional optical image. The instrument was used to study chromosome structures. High-resolution chromosome images revealed details of the 30-nm chromatide structure, confirming earlier electron microscopic observations. Chromosomes treated with trypsin revealed a banding pattern in height which is very similar to the optical image observed after staining with Giemsa. Furthermore, it is shown that the AFM can be used to locate DNA probes on in situ hybridized chromosomes. Images of the synaptonemal complex isolated from rat spermatocytes revealed details that improve the understanding of the three-dimensional structure of this protein.

Animals

Simple delay monitor for droplet sorters.

We have constructed a simple device by which the optimal delay time between optical measurement of a cell and the application of the droplet charging pulse can be determined directly in a flow sorter. The device consists of a stainless steel chamber in which the sorted droplets are collected. In the collection chamber the collected droplets run through a capillary where a continuous fluorescence measurement is made. With a sample of fluorescent particles, the delay time is optimal when the measured fluorescence is maximal. The measuring volume is always filled with the last droplets sorted (about 3,000). With this device, the setting of the delay time can be done in a few seconds without the need for microscopical verification. The fluorescence in the collection chamber is excited and detected via optical fibers using about 10% of the light of the existing laser from the flow cytometer and an extra photomultiplier.

Cell Separation

A simple and sensitive flow cytometric assay for the determination of the cytotoxic activity of human natural killer cells.

A new, simple and sensitive flow cytometric assay for the determination of the cytotoxic activity of human natural killer cells is described. The assay is based on the use of two fluorochromes. The target cell population is stained with one fluorochrome (octadecylamine-fluorescein isothiocyanate, F-18) prior to incubation with the effector cells. F-18 remains in the membrane of the target cells even when they are killed thereby permitting a clear separation between effector and target cells. Dead cells are determined by staining with a second fluorochrome (propidium iodide) after incubation of effector and target cells. staining with a second fluorochrome (propidium iodide) after incubation of effector and target cells. F-18 is not toxic and does not decrease the cytotoxic activity of human natural killer cells. It is also stable (exchange between labeled and non-labeled cells is negligible in a period of at least 4 h at 37 degrees C) and it remains in the membrane of the killed cells. A clear distinction between unlabeled effector and labeled target cells is obtained, even after incubation of target and effector cells for 4 h at 37 degrees C and using a high effector cell-target cell ratio (75:1). A good correlation with the 51Cr release assay was obtained. A potential application of the flow cytometric cytotoxicity assay using whole blood instead of isolated lymphocytes is presented.

Cell Line

Discrimination of human cytotoxic lymphocytes from regulatory and B-lymphocytes by orthogonal light scattering.

Light scattering properties of human lymphocyte subpopulations selected by immunofluorescence were studied with a flow cytometer. Regulatory and B-lymphocytes showed a low orthogonal light scatter signal, whereas cytotoxic lymphocytes identified with leu-7, leu-11 and leu-15 revealed a large orthogonal light scatter signal. Two populations in light scatter histograms could be observed with monoclonal antibodies directed against determinants present on both regulatory and cytotoxic lymphocytes. By analysis of the lymphocytes of 16 individuals we found a linear relation between the number of cells with a large orthogonal light scattering and the number of cytotoxic lymphocytes identified with leu-7, leu-11 and leu-15. These observations demonstrate physical differences between cytotoxic lymphocytes and regulatory and B lymphocytes. Moreover, the results suggest a method to estimate the amount of cytotoxic lymphocytes without using monoclonal antibodies.

B-Lymphocytes

Photosynthetic electron transport and electrochromic effects at sub-zero temperatures.

Spinach chloroplasts, suspended in a liquid medium containing ethyleneglycol, showed reversible absorbance changes near 700 and 518 nm due to P-700 and "P-518" in the region from -35 to -50 degrees C upon illumination. The kinetics were the same at both wavelengths, provided absorbance changes due to Photosystem II were suppressed. At both wavelengths, the decay was slowed down considerably, not only by the System I electron acceptor methyl viologen, but also by silicomolybdate. The effect of the latter compound is probably not due to the oxidation of the reduced acceptor of Photosystem I by silicomolybdate, but to the enhanced accessibility of the acceptor to some other oxidant. In the presence of both an electron donor and acceptor for System I, a strong stimulation of the extent of the light-induced absorbance increase at 518 nm was observed. The most effective donor tested was reduced N-methylphenazonium methosulphate (PMS). The light-induced difference spectrum was similar to spectra obtained earlier at room temperature, and indicated electrochromic band shifts of chlorophylls a and b and carotenoid, due to a large potential over the thylakoid membrane, caused by sustained electron transport. It was estimated that steady-state potentials of up to nearly 500 mV were obtained in this way; the potentials reversed only slowly in the dark, indicating a low conductance of the membrane. This decay was accelerated by gramicidin D. The absorbance changes were linearly proportional to the membrane potential.

Chloroplasts

Light-induced absorbance changes due to photosystems 1 and 2 in spinach chloroplasts at minus 50 degrees C.

Absorbance changes in the region 500-565 nm and at 702 nm, brought about by excitation of Photosystems 1 and 2, respectively, were measured in spinach chloroplasts at minus 50 degrees C. Either dark-adapted chloroplasts were used or chloroplasts preilluminated with a number of short saturating flashes just before cooling. Both photosystems were found to cause a light-induced increase of absorbance at 518 nm (due to "P518"). The System 1-induced change was not affected by pre-illumination. It decayed within 1 s in the dark and showed similar kinetics as P700. Experiments in the presence of external electron acceptors (methylviologen or Fe(CN)6-3-) suggested that P518 was not affected by the redox state of the primary electron acceptor of System 1. The absorbance increase at 518 nm due to System 2 decayed in the dark with a half-time of several min. The kinetics were similar to those of C-550, the presumed indicator of the primary electron acceptor of System 2. After two flashes preillumination the changes due to P518 and C-550 were reduced by about 40%, and a relatively slow, System 2-induced oxidation of cytochrome b559 occurred which proceeded at a similar rate as the increase in yield of chlorophyll a fluorescence. The results indicate that at minus 50 degrees C two different photoreactions of System 2 occur. One consists of a photoreduction of the primary electron acceptor associated with C-550, accompanied by the oxidation of an unknown electron donor; the other is less efficient and results in the photooxidation of cytochrome b559.

Chloroplasts