PubMed Health⌕ Search

Biomedical subjects

B G Lapatki

Publications and source records attributed to B G Lapatki.

4 recordsLinked to original sources

Smart bracket for multi-dimensional force and moment measurement.

Atraumatic, well-directed, and efficient tooth movement is interrelated with the therapeutic application of adequately dimensioned forces and moments in all three dimensions. The lack of appropriate monitoring tools inspired the development of an orthodontic bracket with an integrated microelectronic chip equipped with multiple piezoresistive stress sensors. Such a 'smart bracket' was constructed (scale of 2.5:1) and calibrated. To evaluate how accurately the integrated sensor system allowed for the quantitative determination of three-dimensional force-moment systems externally applied to the bracket, we exerted 396 different force-moment combinations with dimensions within usual therapeutic ranges (+/- 1.5 N and +/- 15 Nmm). Comparison between the externally applied force-moment components and those reconstructed on the basis of the stress sensor signals revealed very good agreement, with standard deviations in the differences of 0.037 N and 0.985 Nmm, respectively. We conclude that our methodological approach is generally suitable for monitoring the relatively low forces and moments exerted on individual teeth with fixed orthodontic appliances.

Calibration↗

A thin, flexible multielectrode grid for high-density surface EMG.

Although the value of high-density surface electromyography (sEMG) has already been proven in fundamental research and for specific diagnostic questions, there is as yet no broad clinical application. This is partly due to limitations of construction principles and application techniques of conventional electrode array systems. We developed a thin, highly flexible, two-dimensional multielectrode sEMG grid, which is manufactured by using flexprint techniques. The material used as electrode carrier (Polyimid, 50 microm thick) allows grids to be cut out in any required shape or size. One universal grid version can therefore be used for many applications, thereby reducing costs. The reusable electrode grid is attached to the skin by using specially prepared double-sided adhesive tape, which allows the selective application of conductive cream only directly below the detection surfaces. To explore the practical possibilities, this technique was applied in single motor unit analysis of the facial musculature. The high mechanical flexibility allowed the electrode grid to follow the skin surface even in areas with very uneven contours, resulting in good electrical connections in the whole recording area. The silverchloride surfaces of the electrodes and their low electrode-to-skin impedances guaranteed high baseline stability and a low signal noise level. The electrode-to-skin attachment proved to withstand saliva and great tensile forces due to mimic contractions. The inexpensive, universally adaptable and minimally obstructive sensor allows the principal advantages of high-density sEMG to be extended to all skeletal muscles accessible from the skin surface and may lay the foundation for more broad clinical application of this noninvasive, two-dimensional sEMG technique.

Electrodes↗

A surface EMG electrode for the simultaneous observation of multiple facial muscles.

With previous surface electromyography (sEMG) electrodes it has been difficult to combine small outer dimensions and secure skin attachment. We resolved this problem by developing a new skin attachment technique that yields firm electrode fixation without requiring an acrylic housing. Consequently, we could reduce the outer electrode dimensions to 4-mm diameter and only 1.5-mm thickness. In a bipolar montage, this electrode allows an inter-electrode distance of 8 mm. This improves measurement selectivity and, because of the small dimensions, makes possible the non-invasive observation of multiple facial muscles with a minimum of obstruction. Our new technique was tested on a group of 11 professional trumpeters. They were instructed to perform a series of muscle-specific facial poses and to play exercises on their instruments while EMG signals were recorded simultaneously from seven different perioral muscles. Although the skin attachment was subjected to high stress during trumpet playing, more than 98% of electrode placements yielded a secure mechanical and electrical connection. Muscle selectivity of the signals recorded during the facial poses was similar to that obtained in a previous investigation using intra-muscular fine-wire electrodes. Crosstalk in the perioral area was estimated to be lower than 25%. The availability of an unobstructive sEMG electrode for simultaneously observing multiple facial muscles opens up a wide range of applications (e.g. in speech research, psychophysiology and orthodontics).

Adult↗

The importance of the level of the lip line and resting lip pressure in Class II, Division 2 malocclusion.

Many clinicians hypothesize that retroclination of the maxillary central incisors in Class II, Division 2 malocclusion is caused by increased resting lip pressure against these teeth. The purpose of this study was (1) to verify this assumption by means of simultaneous lip-pressure measurements at two different levels on the maxillary central incisor crowns, and (2) to examine factors that could possibly contribute to the increased resting lip pressure. This is the first study to prove that individuals with Class II, Division 2 malocclusion (n = 21) have the upper central incisors exposed to significantly higher lip pressure than those with Class I malocclusion (n = 21). Our statistical evaluation revealed that this is primarily attributed to a high lip line and not to a hypertonic peri-oral musculature. We concluded that orthodontic treatment of Class II, Division 2 cases should include intrusion of the maxillary incisors, to eliminate the non-physiologically high pressure exerted by the lower lip on these teeth and, consequently, to reduce the high risk of a post-orthodontic relapse.

Adult↗