PubMed HealthSearch

Biomedical subjects

B G Steinbach

Publications and source records attributed to B G Steinbach.

7 recordsLinked to original sources

Metastatic cervical carcinoma to the breast.

Metastatic disease to the breast is often an unexpected diagnosis in a female who presents with a breast mass. The most important factor suggesting the appropriate diagnosis is a history of cancer. Correlation of mammographic and ultrasonographic findings may also raise the possibility of a metastatic mass. A well-defined, noncalcified dense mass on film-screen mammography, which also shows low-level homogeneous echoes without posterior acoustic enhancement, suggests the diagnosis. It is important that the diagnosis be made by fine needle aspiration or excisional biopsy so as to expedite appropriate therapy.

Biopsy

Phantom evaluation of imaging modalities for silicone breast implants.

RATIONALE AND OBJECTIVES: Recent concern regarding possible adverse effects from silicone breast implants has increased the role of radiologists in assessing augmented breasts. The authors compare the commonly available imaging modalities in evaluating the intact silicone implant as well as free silicone in the adjacent tissue. METHODS: A contrast resolution phantom and breast of veal phantom were tested. Fat was used as a reference material. The phantoms were imaged with xeromammography, film-screen mammography, ultrasound, computed tomography (CT), and magnetic resonance imaging (MRI). Proton MRI spectroscopy also was performed on fat, silicone, water, and water/gelatin samples. The consensus of two radiologists determined whether free silicone was present. RESULTS: CT and MRI provided the best images of the implant and the free silicone. Several features of MRI were useful: spin-density scans and the fast low-angle shot (FLASH) and fast imaging with steady-state precision (FISP) techniques provided excellent resolution, a consistent chemical shift artifact appeared around the silicone, and frequency selective pre-saturation techniques resulted in marked suppression of the silicone. CONCLUSION: Additional testing in a more realistic setting, breast coil design, and improvement of various MRI techniques, particularly the frequency selective pre-saturation techniques, all appear promising in evaluating breast implants, the presence of free silicone, and the adjacent tissues.

Breast

Noninvasive assessment of implant capsules.

The assessment of implant capsular contracture has been imprecise and vulnerable to observer bias. Attempts to measure capsules with instruments that measure implant deformability are influenced by surrounding breast tissue, subcutaneous fat, and skin. Xeromammography, B-mode ultrasound, and CT were employed in an effort to provide a noninvasive and accurate method of capsule assessment. Through two study phases, implants were placed bilaterally in a total of 21 rabbits. At 4 months, animals underwent radiologic assessment and were then sacrificed for direct implant capsule measurements. Mammographic measurements, more than ultrasound-derived measurements, strongly correlated with laboratory measures of capsular dimensions and deformability. Cross-table lateral mammographic views were more informative than traditional views, providing measures of diameter and height that both strongly correlated with laboratory measurements. CT is theoretically the most accurate method to assess contracture, but it is impractical because of expense and time requirements. The results indicate that radiologic assessment, in particular by xeromammography, of implant capsules is accurate, practical, and noninvasive. Mammography strongly correlates with laboratory measures of implant capsular contracture and therefore could be used in the clinical setting to assess capsular contracture.

Animals

Retractable-barb needle for breast lesion localization: use in 60 cases.

A needle system with a retractable barb was developed for localization of nonpalpable breast lesions. The system can be repositioned without major adjustments and strongly anchors to breast tissue, eliminating failure due to dislodgment or transection of the localizing wire. Its use may necessitate fewer confirmatory radiographs, resulting in decreased radiation exposure. In addition, the needle can be retracted during surgery, to ease extraction of the specimen.

Biopsy, Needle