PubMed Health⌕ Search

Biomedical subjects

B G de Grooth

Publications and source records attributed to B G de Grooth.

At least 37 records · Page 2Linked to original sources

Changes in intracellular calcium concentration and pH of target cells during the cytotoxic process: a quantitative study at the single cell level.

This study reports on the changes in intracellular calcium concentration ([Ca2+]in) and intracellular pH ([pH]in) that occur in K562 target cells during interaction with human Natural Killer (NK) cells. The data were obtained using a quantitative fluorescence microscope and fluorescent ratio probes specific for [Ca2+]in (Fura-2-AM) and [pH]in (BCECF-AM). Results demonstrate that two types of target cell response to the attack by an NK cell can be distinguished. The target cell either dies immediately, due to the complete breakdown of the membrane impermeability, or the initial membrane damage (i.e., increased membrane permeability) is repaired and the cell "escapes" immediate death. During both responses an increase of [Ca2+]in takes place in the target cells. In the cells that die immediately, however, [Ca2+]in reaches higher levels (approximately 1,400 nM) than in the cells that restore the initial damage (approximately 700 nM). Changes in target cell [pH]in are also detected during both responses. The direction of the change (acidification or alkalinization) as well as the level of the change depend on extracellular pH ([pH]ex). Also, [pH]in remains changed during the time the cells were followed (10 min). The programming time (i.e., the time from the initiation of the cytotoxic process to the time that a change in the physiological parameter was detected) of the killing process that leads to an immediate target cell death appears to be shortest at [pH]ex 7.3-7.6 (approximately 3 min).

Calcium↗

Changes in actin organization during the cytotoxic process.

Changes in organization of F-actin during the cytotoxic process between NK and K562 cells have been observed and studied using confocal laser scanning microscopy and quantitative fluorescence microscopy. An increase in F-actin content and orientation of F-actin towards the target cell have been observed in conjugated NK cells. The increase in F-actin content probably reflects activation of the NK cell for the killing process. An increase in F-actin content in the conjugated K562 cell, occurring simultaneously with the appearance of filamentous actin structures that often originated/ended at the contact place with the NK cell, was also observed. These changes were delayed compared to the increase in F-actin content in the NK cell and were accompanied by increasing cytotoxic activity. This indicates that they were results of the interaction of the K562 cell with the activated NK cell. The possible role of target cell microfilaments in the cytotoxic process is addressed.

Actin Cytoskeleton↗

ANALYSIS: software for graphical analysis of multidimensional flow cytometric list mode data.

A computer program for graphical analysis of multidimensional flow cytometric list mode data is described. The program offers one-, two-, and three-dimensional inspection of an amount of data that is only limited by disk space. Subpopulations within the original data set can be identified by setting one or more two-dimensional AND gates around them. The order of measurement can be used as a parameter for evaluation of time-dependent processes. Other new parameters can be made by zooming in on a parameter, logarithmic transformation, or division of two parameters. The program is written in Turbo Pascal and it can run on any MS-DOC PC with an EGA/VGA resolution screen.

Computer Graphics↗

Viscoelasticity of living cells allows high resolution imaging by tapping mode atomic force microscopy.

Application of atomic force microscopy (AFM) to biological objects and processes under physiological conditions has been hampered so far by the deformation and destruction of the soft biological materials invoked. Here we describe a new mode of operation in which the standard V-shaped silicon nitride cantilever is oscillated under liquid and damped by the interaction between AFM tip and sample surface. Because of the viscoelastic behavior of the cellular surface, cells effectively "harden" under such a tapping motion at high frequencies and become less susceptible to deformation. Images obtained in this way primarily reveal the surface structure of the cell. It is now possible to study physiological processes, such as cell growth, with a minimal level of perturbation and high spatial resolution (approximately 20 nm).

Animals↗

A flow cytometric study of the membrane potential of natural killer and K562 cells during the cytotoxic process.

This study demonstrates that it is possible to investigate the membrane potential of interacting cells during the cytotoxic process using flow cytometry. Changes in the membrane potential of NK and K562 cells, involved in a cell-mediated cytotoxic process, were studied by standard and slit-scan flow cytometry, using the membrane potential sensitive fluorescent probe DiBAC4(3). The NK cells were labeled with a membrane marker (TR-18 or DiI) prior to incubation with K562 cells and the conjugates that were formed could be identified on the basis of the membrane marker fluorescence and light scattering signals. With a slit-scan technique we measured the membrane potential of each cell in a conjugate separately. The results show that depolarization of the K562 cell occurs as a consequence of the cytotoxic activity of the NK cell. This depolarization appears to be an early sign of cell damage because the cell membrane still remains impermeable to propidium iodide. Our data also indicate that depolarization of the NK cell occurs as a result of its cytotoxic activity.

Clone Cells↗

A simple optical fiber device for quantitative fluorescence microscopy of single living cells.

A simple and relatively inexpensive system is described for obtaining quantitative fluorescence measurements on single living cells loaded with a fluorescent probe to study cell physiological processes. The light emitted from the fluorescent cells is captured by and transported through an optical fiber. After passage through appropriate filters the light is measured using a photomultiplier tube. The optical fiber is mounted in one of the microscope outlets. Signals derived from the photomultiplier are converted to voltage, amplified, and displayed on a recorder. In the excitation pathway a shutter control unit is mounted. With this control unit the period that the excitation pathway is 'opened' and 'closed' can be adjusted, to reduce cell damage and/or bleaching of the probe. This option allows time-lapse recording of experiments up to 1 h. We have used this set-up with a single and dual emission fluorescent probe to determine intracellular calcium concentrations and pH, respectively. In Fluo-3-loaded K562 target cells bound to natural killer cells, a temporary rise in [Ca2+]i was accompanied by bleb formation. The simple construction of this set-up is interchangeable between different types of fluorescence microscopes and can easily be combined with other microscopy techniques, e.g., patch clamp.

Calcium↗

Signal processing in slit-scan flow cytometry of cell conjugates.

The design and implementation of a real-time signal processing system for slit-scan flow cytometry is described. The system is used to measure the separate scatter and fluorescence peak heights of 2 adherent cells. Preliminary measurements of changes in the membrane potential induced by interactions between natural killer (NK) cells and their target cells are presented.

Barbiturates↗

Flow cytometric method for simultaneous detection of lymphocyte-K562 conjugates and immunophenotyping of the conjugate forming cells.

A flow cytometric method for the simultaneous quantification and immunophenotyping of conjugates formed by human peripheral blood lymphocytes (PBL) and K562 cells has been developed. The method uses three fluorescent probes. One of the fluorescent probes (F-18) is used for labeling of PBL prior to incubation with K562 cells. After incubation the cells are treated with monoclonal antibodies labeled with phycoerythrin and Red613, respectively. The combination of F-18 fluorescence and light scattering signals enables identification and quantification of the conjugates while the fluorescence of the monoclonal antibodies provides information about the phenotype of the conjugate forming cells. Results obtained using different monoclonal antibodies are presented. The highest conjugate forming capacity has been found in the CD56+CD8+ population while the CD4+CD8- population has shown the lowest capacity to form conjugates. The influence of a washing step on the conjugate formation is discussed. The possibility to use the method in combination with a cytotoxicity assay is indicated.

Antibodies, Monoclonal↗

Selective electrofusion of conjugated cells in flow.

Using a modified flow cytometer we have induced electrofusion of K562 and L1210 cells in flow. The two cell types are stained with two different fluorescent membrane probes, DiO and DiI, to facilitate optical recognition, and then coupled through an avidin-biotin bridge. In the flow cytometer, the hydrodynamically focused cells and cell pairs are first optically analyzed in a normal flow channel and then forced to flow through a Coulter orifice. If the optical analysis indicates that a cell pair is present, an electric pulse is applied across the orifice to induce fusion. The pulsed cell pairs were subsequently analyzed using normal and confocal microscopy to evaluate fusion induction. It appears that fusion can be induced in about 10% of pulsed cell pairs when one electric pulse with a duration of 10-15 microseconds and an effective electric field strength of 4-8 10(5) V/m is used.

Animals↗

Experimental and theoretical investigations on the validity of the geometrical optics model for calculating the stability of optical traps.

We have developed a computer program based on the geometrical optics approach proposed by Roosen to calculate the forces on dielectric spheres in focused laser beams. We have explicitly taken into account the polarization of the laser light and thd divergence of the laser beam. The model can be used to evaluate the stability of optical traps in a variety of different optical configurations. Our calculations explain the experimental observation by Ashkin that a stable single-beam optical trap, without the help of the gravitation force, can be obtained with a strongly divergent laser beam. Our calculations also predict a different trap stability in the directions orthogonal and parallel to the polarization direction of the incident light. Different experimental methods were used to test the predictions of the model for the gravity trap. A new method for measuring the radiation force along the beam axis in both the stable and instable regions is presented. Measurements of the radiation force on polystyrene spheres with diameters of 7.5 and 32 microns in a TEM00-mode laser beam showed a good qualitative correlation with the predictions and a slight quantitative difference. The validity of the geometrical approximations involved in the model will be discussed for spheres of different sizes and refractive indices.

Lasers↗

A new principle of cell sorting by using selective electroporation in a modified flow cytometer.

When a strong electric field pulse of a few microseconds is applied to biological cells, small pores are formed in the cell membranes; this process is called electroporation. At high field strengths and/or long pulse durations the membranes will be damaged permanently. This eventually leads to cell kill. We have developed a modified flow cytometer in which one can electroporate individual cells selected by optical analysis. The first experiments with this flow cytometer were designed to use it as a damaging sorter; we used electric pulses of 10 microseconds and resulting field strengths of 2.0 and 3.2 x 10(6) V/m to kill K562 cells and lymphocytes respectively. The hydrodynamically focused cells are first optically analyzed in the usual way in a square flow channel. At the end of this channel the cells are forced to flow through a small Coulter orifice, into a wider region. If optical analysis indicates that a cell is unwanted, the cell is killed by applying a strong electric field across the Coulter orifice. The wanted living cells can be subsequently separated from the dead cells and cell fragments by a method suitable for the particular application (e.g., centrifugation, cell growth, density gradient, etc.). The results of these first experiments demonstrate that by using very simple equipment, sorting by selective killing with electric fields is possible at rates of 1,000 cells/s with a purity of the sorted fraction of 99.9%.

Cell Membrane Permeability↗

Cytotoxic lymphocytes in B-cell chronic lymphocytic leukemia. A flow cytometric study of peripheral blood, lymph nodes and bone marrow.

The occurrence of cytotoxic lymphocyte subpopulations (i.e., CD 16+, CD 57+ and cytotoxic CD 8+) wa studied in the peripheral blood of 18 B-cell chronic lymphocytic leukemia (B-CLL) patients. The absolute numbers of CD 57+, CD 16+ and cytotoxic CD 8+ lymphocytes were increased in the peripheral blood of untreated patients as compared with healthy donors, suggesting a causal relation with the accumulation of malignant B-cells. For 5 B-CLL patients and 5 hematological normal donors, the lymphocyte subpopulations in peripheral blood, lymph nodes and bone marrow were determined. A significant immune response was observed in the lymph nodes of the patients, as reflected by the CD 3+ lymphocytes, which were 1.7-27 times larger in the patients lymph nodes than in their peripheral blood and bone marrow. In contrast, with peripheral blood this was mainly caused by an increase in CD 4+ lymphocytes. The CD 57 lymphocytes in the lymph nodes of the patients had abnormal orthogonal light-scattering signals and an abnormal density of CD 57+ receptors in comparison with their peripheral blood CD 57+ lymphocytes or the CD 57+ lymphocytes in the peripheral blood, bone marrow and tonsils of the hematological normal donors. This study shows that although a significant increase of cytotoxic lymphocytes in the peripheral blood of B-CLL patients is observed, the actual distributions of the non-malignant lymphocytes can be quite different at the actual tumor sites, i.e., bone marrow and lymph nodes.

Adult↗

Four-parameter white blood cell differential counting based on light scattering measurements.

Measurement of the depolarized orthogonal light scattering in flow cytometry enables one to discriminate human eosinophilic granulocytes from neutrophilic granulocytes. We use this method to perform a four-parameter differential white blood cell analysis. A simple flow cytometer was built equipped with a 5-mW helium neon laser that measures simultaneously four light scattering parameters. Lymphocytes, monocytes, and granulocytes were identified by simultaneously measuring the light scattering intensity at angles between 1.0 degrees and 2.6 degrees and angles between 3.0 degrees and 11.0 degrees. Eosinophilic granulocytes were distinguished from neutrophilic granulocytes by simultaneous measurement of the orthogonal and depolarized orthogonal light scattering. Comparison of a white blood cell differentiation of 45 donors obtained by the Technicon H-6000 and our instrument revealed good correlations. The correlation coefficients (r2) found were: 0.99 for lymphocytes, 0.76 for monocytes, 0.99 for neutrophilic granulocytes, and 0.98 for eosinophilic granulocytes. The results demonstrate that reliable white blood cell differentiation of the four most clinically relevant leukocytes can be obtained by measurement of light scattering properties of unstained leukocytes.

Basophils↗

Application of orthogonal light scattering for routine screening of lymphocyte samples.

Orthogonal and forward light-scattering properties of lymphocytes were measured from patients with different lymphocytic diseases in order to determine the potential value of light scattering as a screening device. Monitoring of orthogonal light scattering of lymphocytes of a B-cell chronic lymphocytic leukemia patient during splenic irradiation (SI) revealed the selective decrease of malignant cells and the fact that the major part of the residual lymphocytes were cytotoxic lymphocytes. By combining forward and orthogonal light scattering it was shown that lymphocytes from a patient with T gamma lymphocytosis were abnormal. Orthogonal light scattering also showed an increase in cytotoxic lymphocytes in a patient with mononucleosis infectiosa and in a splenectomized patient. Orthogonal light scattering of lymphocyte subpopulations showed that the leu8+ population of a patient with mononucleosis infectiosa was bidisperse. For elderly donors the occurrence of CD3+, CD4+, CD8+, and HNK-1+ lymphocytes with a large orthogonal light scattering varied considerably. The CD8+ lymphocytes of these donors consisted mainly of cytotoxic lymphocytes. These results show that determination of light-scattering properties of lymphocytes may yield important diagnostic information and can indicate when further investigation of the lymphocytes by means of immunofluorescence is necessary.

Adolescent↗

Flow cytometric characterization of chronic lymphocyte leukaemias using orthogonal light scattering and quantitative immunofluorescence.

Light scattering properties and antigen distribution of lymphocytes labeled with the monoclonal antibodies CD 5 and CD 20 were determined for 19 patients with a chronic B-cell derived leukaemia. The density of the antigen detected by the monoclonal antibody CD 5 appeared to be considerably lower on malignant B-lymphocytes of the patients as compared with T lymphocytes. A large variation was observed in the amount of receptors for the monoclonal antibodies CD 5 and CD 20 on the malignant cells of the different patients. B-cell chronic lymphocytic leukaemia (B-CLL) patients were clearly distinguishable from leukaemic follicular non Hodgkin lymphoma patients (LF-NHL, formerly lymphosarcoma cell leukaemia) and from a patient with a prolymphocytoid transformation (PLT) of the B-CLL according to the amount of the antigens for CD 5 and CD 20. Within the B-CLL patient population, no relation of progression of the disease with distribution of these antigens could be observed. In one patient the extraordinary phenotype CD 20+, CD 11+, leu 8+, CD 5- of the malignant lymphocytes was observed. An experimentally simple method to differentiate between the various chronic lymphocytic leukaemias (CLL) appeared to be the determination of orthogonal light scattering properties of lymphocytes. In healthy donors one can always distinguish two populations of lymphocytes in the orthogonal light scatter histograms. Lymphocytes of B-CLL patients show one uniform population with a relatively small orthogonal light scattering signal, lymphocytes of our patients with PLT of B-CLL or with LF-NHL show one uniform population with a relatively large orthogonal light scattering signal.

Antibodies, Monoclonal↗

Abnormal distribution of CD8 subpopulation in B-chronic lymphocytic leukemia identified by flow cytometry.

We studied the occurrence of T-cell subpopulations for patients with B-cell chronic lymphocytic leukemia. The CD8+ population was divided into CD8+ suppressor (CD8a+) and CD8+ cytotoxic (CD8b+) lymphocytes using difference in orthogonal light scattering. Average CD4+/CD8+ ratios determined for all patients were decreased. For individual patients this sometimes was not true. In contrast CD4+/CD8a+ ratios were markedly increased in all individual patients. The CD8+ lymphocytes appeared to consist mainly of CD8b+ lymphocytes. Moreover the CD8b+/CD8+ ratio correlated with clinical stage: untreated patients (stage 0 of Rai) have smaller CD8b+/CD8+ ratios than patients with advanced stages of Rai.

Adult↗

The effects of splenic irradiation on lymphocyte subpopulations in chronic B-lymphocytic leukemia.

We describe the effect of splenic irradiation (SI) (0.5-1 Gy weekly) on lymphocyte subpopulations for 7 patients with progressive B chronic B-lymphocytic leukemia (B-CLL). Using specific cellular characteristics we could distinguish normal from abnormal cells. The irradiation resulted in a decrease of lymph node size, reduction in spleen volume and decrease in peripheral blood lymphocytes. The one exception was a patient with a prolymphocytoid transformation of B-CLL. For 3 patients SI had to be interrupted or stopped because of severe cytopenia. Quantitation of malignant B cells and normal T lymphocytes revealed that the total irradiation dose which resulted in a specific decrease of malignant lymphocytes varied from patient to patient. Normal T-cell subpopulations, which were increased before SI, decreased to normal or abnormally low values during SI. In previously untreated patients, natural killer (NK) cell numbers decreased more rapidly than T-cell subpopulations. For 2 patients refractory to chemotherapy an increase of NK cells was observed upon SI.

Antigens, Differentiation↗

Multiple wavelength illumination in flow cytometry using a single arc lamp and a dispersing element.

The principle of a multiple wavelength illumination method for flow cytometers, based upon a combination of a helium-neon laser and an arc lamp as illumination sources is described. By using a prism, the light from the arc lamp is dispersed and the different colors are imaged at different places on the sample stream. The small angle light scattering from the helium-neon laser light is measured as a relevant parameter and serves as a trigger signal for subsequent measurements of fluorescence or scattering of light from the arc lamp. Two experimental systems are described utilizing this principle: a system where the emission is detected orthogonally with respect to the direction of the illumination beams, and an epi-illumination system. With the orthogonal set-up multiple wave-length right angle scattering measurements are possible. This is illustrated by showing that the orthogonal scattering from erythrocytes is strongly dependent on the illumination wavelength. It is further shown that the apparatus is suitable for the measurement of intracellular pH using the pH dependence of the excitation spectrum of fluorescein. The epi-illumination system allows excitation of two (or more) fluorescent dyes with different excitation spectra. In this case the emission spectra of the fluorescent dyes may overlap substantially. This is shown by simultaneous measurement of DNA and protein of Chinese hamster lung cells using mitramycin and tetramethyl rhodamin isothiocyanate (TRITC).

DNA↗