How reliable is the Goldmann tonometer as a standard?

In a clinical comparison of an XPERT NCT non-contact tonometer with Goldmann applanation tonometry (GAT), reported in the companion article, we concluded that the XPERT is a highly accurate and reliable instrument. By design, our evaluation differed significantly from earlier clinical studies in its use of multiple references (four calibrated GAT reference tonometers and seven GAT operators). Five clinicians were responsible for GAT measurement of 400 of a 620 eye population. Each clinician's population sample was essentially drawn at random from the common pool. XPERT vs. GAT performance indices were calculated for each of the five GAT operators. Because XPERT's measurements are essentially free of operator influence, it is reasonable to conclude that differences found among these five "XPERT performance" findings were primarily attributable to differences in GAT operator technique and endpoint judgment. Our findings disclose compelling evidence that GAT's accuracy and reliability depends on individual operator technique and experience. They indicate that in a clinical comparison, the protocol safeguards proposed by Wittenberg need be applied to ensure the integrity of studies using GAT as the reference tonometer.

Humans

XPERT NCT--a clinical evaluation.

A clinical evaluation of the XPERT NCT (Reichert Ophthalmic Instruments) applanation non-contact tonometer was conducted at the Baltimore VA Medical Center. Each of 620 eyes were measured by the XPERT and then by one of seven operators of varied experience, each using one of four calibrated Goldmann applanation tonometers (GATs). Measured pressures ranged from 1 to more than 60 mmHg. The interval between XPERT and GAT measurements varied from a few minutes to almost 1 hour. Despite the increased potential variability of our protocol, the XPERT agreed very closely with GAT. Population IOP means agreed within 0.3 mmHg; regression coefficients defining XPERT's calibration, relative to GAT, were slope (m) = 1.025, and Y intercept (b) = 0.7 mmHg. The standard deviation of matched pair differences, was Sd = 2.7 mmHg. We conclude that the XPERT NCT is a highly accurate and reliable instrument. Our experience showed it to be convenient and well accepted by staff and patients. It proved faster, easier to use, and its "air-puff" is quieter and less intense than NCT I and II. In the companion paper, we examined the reliability of GAT used as a clinical comparison reference in evaluating the XPERT.

Evaluation Studies as Topic