PubMed Health⌕ Search

Biomedical subjects

B H Brown

Publications and source records attributed to B H Brown.

At least 19 recordsLinked to original sources

Study of the optimum level of electrode placement for the evaluation of absolute lung resistivity with the Mk3.5 EIT system.

Inter-subject variability has caused the majority of previous electrical impedance tomography (EIT) techniques to focus on the derivation of relative or difference measures of in vivo tissue resistivity. Implicit in these techniques is the requirement for a reference or previously defined data set. This study assesses the accuracy and optimum electrode placement strategy for a recently developed method which estimates an absolute value of organ resistivity without recourse to a reference data set. Since this measurement of tissue resistivity is absolute, in Ohm metres, it should be possible to use EIT measurements for the objective diagnosis of lung diseases such as pulmonary oedema and emphysema. However, the stability and reproducibility of the method have not yet been investigated fully. To investigate these problems, this study used a Sheffield Mk3.5 system which was configured to operate with eight measurement electrodes. As a result of this study, the absolute resistivity measurement was found to be insensitive to the electrode level between 4 and 5 cm above the xiphoid process. The level of the electrode plane was varied between 2 cm and 7 cm above the xiphoid process. Absolute lung resistivity in 18 normal subjects (age 22.6 +/- 4.9, height 169.1 +/- 5.7 cm, weight 60.6 +/- 4.5 kg, body mass index 21.2 +/- 1.6: mean +/- standard deviation) was measured during both normal and deep breathing for 1 min. Three sets of measurements were made over a period of several days on each of nine of the normal male subjects. No significant differences in absolute lung resistivity were found, either during normal tidal breathing between the electrode levels of 4 and 5 cm (9.3 +/- 2.4 Omega m, 9.6 +/- 1.9 Omega m at 4 and 5 cm, respectively: mean +/- standard deviation) or during deep breathing between the electrode levels of 4 and 5 cm (10.9 +/- 2.9 Omega m and 11.1 +/- 2.3 Omega m, respectively: mean +/- standard deviation). However, the differences in absolute lung resistivity between normal and deep tidal breathing at the same electrode level are significant. No significant difference was found in the coefficient of variation between the electrode levels of 4 and 5 cm (9.5 +/- 3.6%, 8.5 +/- 3.2% at 4 and 5 cm, respectively: mean +/- standard deviation in individual subjects). Therefore, the electrode levels of 4 and 5 cm above the xiphoid process showed reasonable reliability in the measurement of absolute lung resistivity both among individuals and over time.

Adult↗

Electrical bioimpedance readings increase with higher pressure applied to the measuring probe.

Electrical bioimpedance spectroscopy (EBIS) is a technique that uses a probe to calculate the transfer impedance from tissues. This transfer impedance can give information about the normal or pathological condition of the tissue. To take readings, pressure has to be applied to the probe in order to get a good contact between the electrodes and the tissue. We have been using EBIS to investigate the early diagnosis of dysplasia and cancer in the human cervix, oesophagus and bladder. We have found that, with increasing pressure (range used here was approximately 1 kPa to approximately 50 kPa), the resistivity readings increase in a consistent way up to 80%. In this paper, we show how this is a case in three different tissue types (oesophageal, gastric and vesical samples). These increases can be higher than those associated with the pathological changes that we are investigating (non-inflamed columnar tissue, for instance, shows values 50% higher than dysplastic columnar tissue). Finite-element modelling was also used to investigate the effect of volume reduction in the connective tissue or stroma. This simulation suggests no strong correlation between reduction of this structure and increase in resistivity. We hypothesize therefore that these changes may be mainly associated with the squeezing of water from the extracellular space. Finally, as pressure is difficult to control by hand, we raise the issue of the necessity of considering this variable when making EIS measurements.

Animals↗

Detection of emboli in vessels using electrical impedance measurements--phantom and electrodes.

A phantom was constructed to simulate the electrical properties of the neck. A range of possible electrode configurations was then examined in order to improve the sensitivity of the impedance measurement method for the in vivo detection of air emboli. The neck phantom consisted of simulated skin, fat and muscle layers made of agar and a conductive rubber tube mimicking the common carotid artery. The ring-shaped electrodes with a guard electrode showed the highest sensitivity to emboli at short distances.

Body Composition↗

First case of septicemia due to a strain belonging to enteric group 58 (Enterobacteriaceae) and its designation as Averyella dalhousiensis gen. nov., sp. nov., based on analysis of strains from 20 additional cases.

When enteric group 58 was first described as a distinct new group of Enterobacteriaceae in 1985, there were only five known human isolates: four from wounds and one from feces. In 1996, we investigated the first blood isolate of enteric group 58, a case of sepsis in a 33-year-old woman receiving total parenteral nutrition. Fifteen additional clinical isolates have since been identified at CDC, including several recognized from a collection of "unidentified" strains dating back to 1973. All strains were characterized with a standard set of 49 biochemical tests used for Enterobacteriaceae, and the results were analyzed to determine phenotypic relatedness and best taxonomic fit. Antibiograms were determined as a taxonomic tool. Original identifications provided by submitting laboratories encompassed a wide variety of Enterobacteriaceae, including 14 species in eight genera, the most common being Enterobacter spp., Salmonella spp., Serratia spp., Kluyvera spp., or Escherichia spp. Enteric group 58 strains have been most frequently isolated from traumatic injuries, fractures, and wounds and rarely from feces. Defining its clinical significance and distinguishing infection from colonization requires further study, but our case report indicates that serious systemic infection can occur. The vernacular name enteric group 58 was used from 1985 to 2004. In this paper, we formally name it Averyella dalhousiensis gen. nov., sp. nov., on the basis of its unique phenotype and its unique 16S rRNA gene sequence. These data indicate that enteric group 58 is not closely related to any of the existing genera or species of Enterobacteriaceae. The type strain is designated CDC 9501--97, and a phenotypic definition is given based on all 21 strains.

Adult↗

Estimation of the size of air emboli detectable by electrical impedance measurement.

Non-invasive detection of air emboli in blood is investigated in vitro using a tetrapolar electrical impedance measurement. A cubic tank with a linear array of four electrodes, spaced approximately 1 cm apart down one side, was filled with 0.2 Sm(-1) saline. Bubbles were generated by carbon dioxide gas. Electrical transfer impedance was measured every 8.2 ms at 1.25 MHz. The movement of bubbles was recorded by a video camera, and their sizes and depths from the middle of the array were measured using captured video images. Changes in transfer impedance caused by passage of bubbles were clearly observed and almost identical with those calculated theoretically. Using lead field theory and experimental results, the fundamental limit on the detectable size of bubbles was estimated at the carotid artery, the great saphenous vein and the cephalic vein. The theoretical results showed that a 0.5 mm diameter bubble is detectable at a depth of 5.3 mm, similar to the depth of the great saphenous and the cephalic veins, and a 2.3 mm diameter bubble is detectable at a depth of 21 mm, similar to the depth of the common carotid artery.

Electric Impedance↗

Electrical impedance measurements: an objective measure of prelabor cervical change.

OBJECTIVE: To investigate the use of electrical impedance measurements of the pregnant cervix as an objective measure of cervical favorability (Bishop score > or = 5). METHODS: A prospective study of 86 women, investigating electrical impedance measurements of the pregnant cervix at the time of induction of labor. Transfer electrical impedance measurements were made by placing a tetrapolar pencil probe of 8 mm in diameter on the surface of the cervix. A Bishop score was determined simultaneously. RESULTS: A mean resistivity (standard error of the mean) of 7.03 (6.01-8.04) omega(m) was measured for the unfavorable group and 5.34 (4.61-6.07) omega(m) for the favorable group. This was a statistically significant difference (p = 0.016). CONCLUSION: We highlight the ability of this safe, painless technique to differentiate the favorable from the unfavorable cervix at induction of labor.

Adolescent↗

A study of the morphological parameters of cervical squamous epithelium.

Electrical impedance spectroscopy is a technique that has been investigated as a potential method for the diagnosis of epithelial carcinomas. Finite element modelling can provide an insight into the patterns of current flow in normal and pathological epithelium and hence aid in the process of probe design optimization. In order to develop a finite element model of the structure of normal and precancerous cervical squamous epithelium, it was first necessary to obtain the mean values and ranges of a number of morphological tissue parameters. The most important parameters in discriminating normal from neoplastic tissue were identified as being cell size and shape distribution, nuclear-to-cytoplasmic volume ratio and volume of extracellular space. A survey of the literature revealed an absence of reliable quantitative data for these parameters. We therefore present the results of our own basic image analysis on normal and pathological tissue sections, which we hope will be of use to other workers wishing to model cervical squamous epithelium, or other similar tissue structures.

Carcinoma in Situ↗

Low frequency electrical bioimpedance for the detection of inflammation and dysplasia in Barrett's oesophagus.

Biological tissues undergoing inflammation and dysplasia seem to exhibit changes in the intercellular space that can be sensed using low frequency electrical impedance methods. Basically, low frequency electric current flows through this space and its widening as well as the disruption of the tight junction decrease the resistance, facilitating current flow. The electrical changes accompanying structural changes from columnar tissue to adenocarcinoma in Barrett's metaplastic mucosa and gastric tissue are illustrated using resected tissue from 32 patients. Two hundred and fifty-eight biopsies were analysed, correlating their electrical resistivity (R) at 9.6 kHz and their histopathological interpretation. Compared to non-inflamed non-dysplastic columnar tissue (R = 4.9 ohms m), the results suggest a small but statistically significant decrease of electrical impedance in columnar tissue showing inflammation (R = 4.2 ohms m, p = 0.016) and a larger decrease when dysplasia is present (R = 3.4 ohms m, p = 0.040). If this method is validated further, this technique could be used to obtain guided biopsies from patients undergoing surveillance programmes for Barrett's oesophagus. We aim to refine this technique using a new system with lower frequencies and, possibly, in vitro (cultured cells) and in vivo (rats) models of Barrett's oesophagus.

Adenocarcinoma↗

Modelling of epithelial tissue impedance measured using three different designs of probe.

Impedance measurement is a promising technique for detecting pre-malignant changes in epithelial tissue. This paper considers how the design of the impedance probe affects the ability to discriminate between tissue types. To do this, finite element models of the electrical properties of squamous and glandular columnar epithelia have been used. The glandular tissue model is described here for the first time. Glandular mucosa is found in many regions of the gastrointestinal tract, such as the stomach and intestine, and has a large effective surface area. Firstly, the electrical properties of a small section of gland, with epithelial cells and supportive tissue, are determined. These properties are then used to build up a three-dimensional model of a whole section of mucosa containing many thousands of glands. Measurements using different types of impedance probe were simulated by applying different boundary conditions to the models. Transepithelial impedance, and tetrapolar measurement with a probe placed on the tissue surface have been modelled. In the latter case, the impedance can be affected by conductive fluid, such as mucus, on the tissue surface. This effect has been investigated, and a new design of probe, which uses a guard electrode to counteract this potential source of variability, is proposed.

Electric Impedance↗

Neonatal lungs--can absolute lung resistivity be determined non-invasively?

The electrical resistivity of lung tissue can be related to the structure and composition of the tissue and also to the air content. Conditions such as pulmonary oedema and emphysema have been shown to change lung resistivity. However, direct access to the lungs to enable resistivity to be measured is very difficult. We have developed a new method of using electrical impedance tomographic (EIT) measurements on a group of 142 normal neonates to determine the absolute resistivity of lung tissue. The methodology involves comparing the measured EIT data with that from a finite difference model of the thorax in which lung tissue resistivity can be changed. A mean value of 5.7 +/- 1.7 omega(m) was found over the frequency range 4 kHz to 813 kHz. This value is lower than that usually given for adult lung tissue but consistent with the literature on the composition of the neonatal lung and with structural modelling.

Child, Preschool↗

Accuracy of an optically isolated tetra-polar impedance measurement system.

Accurate electrical transfer impedance measurement at the high frequencies (> 1 MHz) required to characterise blood and intracellular structures is very difficult, owing to stray capacitances between lead wires. To solve this problem, an optically isolated measurement system has been developed using a phase-locked-loop technique for synchronisation between current injection (drive) and voltage measurement (receive) circuits. The synchronisation error between drive and receive circuits was less than 1 ns. The accuracy and reproducibility of the developed system was examined using a tissue equivalent Cole model consisting of two resistors and one capacitor. The absolute value Z and phase shift theta in impedance of the Cole model was measured at 1.25 MHz by both an LCR meter and the isolated measurement system. The difference between the values measured by the isolated measurement system and those measured by the LCR meter was less than 0.27omega (2.9%) in Z and 0.79 degree in theta. The standard deviation was less than 0.09 omega in Z and 0.60 degree in theta.

Electric Impedance↗

Neonatal lungs: maturational changes in lung resistivity spectra.

The electrical resistivity of lung tissue can be related to the structure and composition of the tissue and also to the air content. Electrical impedance tomographic measurements have been used on 155 normal children over the first three years of life and 25 pre-term infants, to determine the absolute resistivity of lung tissue as a function of frequency. The results show consistent changes with increasing age in both lung tissue resistivity (5.8 ohm m at birth to 20.9 ohm m at 3 years of age) and in the changes of resistivity with frequency (Cole parameter ratio R/S=0.41 at birth and 0.84 at 3 years of age). Comparison with a lung model showed that the measurements are consistent with maturational changes in the number and size of alveoli, the extracapillary blood volume and the size of the extracapillary vessels. However, the results show that the process of maturation is not complete at the age of three years.

Adult↗

Modelled current distribution in cervical squamous tissue.

The electrical properties of cervical squamous epithelium have been modelled in the frequency range 100 Hz to 10 MHz. The hierarchical modelling process comprises a cellular level stage, which includes detailed models of cells typical of different depths within the epithelium and a tissue model, which utilizes electrical properties obtained from the cellular models. The fit between the modelled and measured impedance spectra and the distribution of current with depth depends on the macroscopic model structure. Both the properties of the basement membrane and the presence of a surface mucus layer are shown to have a significant effect. The best fit with measured data is obtained when a 10 microm thick, high-conductivity surface layer is included in the tissue model.

Algorithms↗

Resistivity changes in conductive silicone sheets under stretching.

This paper reports a preliminary finding associated with an investigation of how tissues respond to mechanical stress. The stress distribution within the tissue may be the result of normal function, for example, joint forces, or it may result from interventions such as tissue suturing during or after surgery. We sought to combine electrical and mechanical computational models in order to better understand the interaction between the two. For example, if mechanical stress is applied to tissue this may change the cell arrangements within the tissue matrix and hence change the electrical properties. If this interaction could be determined, then it should be possible to use electrical impedance tomography measurements to identify stress patterns in tissues. Measurements of resistivity changes have been made in conductive silicone rubber sheets when subject to a uniaxial stress of up to 10%. Relatively large changes in resistivity are produced (up to 200%). These changes are far larger than those predicted arising from topological changes alone. It is suggested that under stress the conductive islands of carbon within the silicone rubber sheet undergo a reversible disassociation from their neighbours and that the material's electrical properties change under load. If similar stress-resistivity relationships occur within biological materials it may be possible to recover the stress fields within tissues from transfer impedance measurements and thereby predict if actions such as inappropriate suture tension will compromise tissue viability.

Algorithms↗

Surface electromyography using electrode arrays: a study of motor neuron disease.

The use of electromyography (EMG) is limited, particularly in the investigation of children, by the invasive nature of needle electrodes. Surface electrode techniques are an attractive alternative but the detected signals are greatly influenced by volume conductor effects, thus making their interpretation problematic. Using finite element analysis we investigated the relationship between surface potential distribution and motor unit depth, incorporating anisotropic conductivity to model muscle tissue and a range of subcutaneous fat thicknesses. The modeling results were used to analyze data recorded with a 16-channel surface electrode array, from 10 normals subjects and 12 patients with motor neuron disease. Differences in the motor units between the two groups were statistically significant (P < 0.01) and are consistent with reinnervation and increased motor unit territory in the patient group. This noninvasive technique shows promise as a more acceptable alternative to the use of conventional needle electrodes for neurophysiological investigations.

Adult↗

Mk3.5: a modular, multi-frequency successor to the Mk3a EIS/EIT system.

This paper describes the Sheffield Mk3.5 EIT/EIS system which measures both the real and imaginary part of impedance at 30 frequencies between 2 kHz and 1.6 MHz. The system uses eight electrodes with an adjacent drive/receive electrode data acquisition protocol. The system is modular, containing eight identical data acquisition boards, which contain DSPs to generate the drive frequencies and to perform the FFT used for demodulation. The current drive is in three sequentially applied packets, where each packet contains ten summed sine waves. The data acquisition system is interfaced to a host PC through an optically isolated high speed serial link (RS485) running at 2 Mbaud (2 Mbits s(-1)). Measurements on a saline filled tank show that the average signal to noise performance of the system is 40 dB measured across all frequencies and that this figure is independent of frequency of measurement. These results suggest that the current system is 10 dB better in absolute terms than the previous Sheffield (Mk3a) system.

Electric Impedance↗

Relation between tissue structure and imposed electrical current flow in cervical neoplasia.

BACKGROUND: When an electrical potential is applied to human tissue, the pattern of the resulting current flow is determined by the shapes, arrangements, and internal structure of the tissue cells. By measurement of the electrical current patterns over a range of frequencies, and use of an inverse modelling procedure, electrical variables describing the tissue structure can be calculated. We used this method to develop a screening technique for the detection of cervical precancers. METHODS: We used a pencil probe (diameter 5 mm) to measure electrical impedance spectra from eight points on the cervix in 124 women with abnormal cervical smears. Variables that should be sensitive to the expected tissue changes were calculated. These were compared with the colposcopic results. FINDINGS: The measured electrical impedance changes were those predicted on the basis of the expected tissue structures. Measurements made on normal squamous tissues were well separated from those made on precancerous tissues. We constructed receiver-operating-characteristic curves, comparing measurements made on normal tissue and that showing cervical intraepithelial neoplasia grade 2/3; the area under the curve was 0.951. These groups of women could be separated with a sensitivity of 0.92 and a specificity of 0.92. INTERPRETATION: Characteristics of the electrical impedance spectra of tissues can be explained by changes in cell arrangements (layering) and in the size of the nuclei. This relation opens the way to deriving tissue structure from electrical impedance spectral measurements. We show that this approach can be used to give good separation of normal and precancerous cervical tissues.

Biopsy↗