PubMed Health⌕ Search

Biomedical subjects

B H Friemel

Publications and source records attributed to B H Friemel.

4 recordsLinked to original sources

Experimental velocity profiles and volumetric flow via two-dimensional speckle tracking.

The performance of a two-dimensional speckle tracking system in measuring in vitro laminar flow is evaluated. The system uses a pattern matching algorithm to track subresolution-sized speckle regions between successive ultrasonic 2D pulse-echo acquisitions in order to determine both the axial and the lateral components of velocity. In this study, multiple 2D vector velocity maps were acquired in real time using a calibrated laminar flow phantom, and then statistically analyzed off-line. At a 90 degrees transducer angle, volumetric flow rates computed from measured velocity profiles exhibited excellent linearity (R2 > 0.99), with a mean error of -6.1%, over the range 5-30 mL/s. At 105 degrees and 120 degrees, experimental volume flow rates also agreed well with actual rates, although measured velocity profiles appeared more irregular with decreasing Doppler angles. Velocity profiles estimated using sampled radio-frequency data rather than envelope-detected data were inconsistent due to an insufficient sampling rate and the quantization of the velocity grid. Results indicate that excellent flow velocity and volume rate estimates can be obtained from vector velocity measurements along a single line of sight, without a priori knowledge of the flow direction, at transducer angles near 90 degrees where Doppler instruments are prone to large errors.

Phantoms, Imaging↗

A real time system for quantifying and displaying two-dimensional velocities using ultrasound.

This paper describes a system that has been developed for measuring two-dimensional velocities in real time using ultrasound. The instrument tracks interframe speckle pattern motion using a Sum-Absolute-Difference (SAD) algorithm in order to produce a vector map of 2D velocities. The system's parallel architecture allows calculation of approximately 20,000 vectors per second using the current tracking geometry. A programmable graphics processor encodes individual velocity vectors with color and displays them superimposed on the B-mode image in real time. In vitro tests indicate that the system can track velocities well over the Doppler aliasing limit in any direction in the scan plane with greater than 94% accuracy. A color encoded image obtained from a flow phantom highlights the system's ability to display lateral motion with uniform coloration, in contrast to the two-color display of current ultrasonic Doppler instruments.

Algorithms↗

Real-time system for angle-independent US of blood flow in two dimensions: initial results.

The authors developed an ultrasound system that enables the speckle patterns produced by echoes from moving blood to be tracked in real time. Unlike current color Doppler flow imagers, this system allows the measurement of blood velocities in any direction within the imaging plane. The authors used this device to image flow in the human jugular vein and contrasted the image with one obtained under similar circumstances with color Doppler flow imaging. The authors demonstrated that this system can display in vivo lateral blood flow in real time. Further development of the system, including the incorporation of wall filters to enhance weak blood echoes and parallel techniques to reduce data acquisition time, will allow clinical imaging of flow with velocities of several meters per second in any direction without aliasing or dependence on the Doppler angle.

Adult↗

Three-dimensional flow images by reconstruction from two-dimensional vector velocity maps.

A method for constructing three-dimensional images of flow is described. The technique involves the acquisition of numerous closely spaced planes, each comprised of a map of the two-dimensional velocities measured in that plane. Each such vector velocity map is formed by tracking the motion of small regions of ultrasonic speckle between two ultrasonic acquisitions separated by a short time interval. In contrast to current Doppler velocity methods, this technique measures both the axial and lateral components of flow and is not subject to aliasing. The resulting series of two-dimensional vector velocity maps is then combined into a three-dimensional data set, which can be manipulated with appropriate software to yield quantitative three-dimensional displays of the flow within the interrogated volume. In this article we present such images obtained from measurements of in vitro laminar flow in a vessel, as well as a free jet phantom. The results allow comprehensive visualization of the three-dimensional flow characteristics, indicating promise for more complete and quantitative clinical assessment of blood flow.

Blood Flow Velocity↗