PubMed Health⌕ Search

Biomedical subjects

B H Walpoth

Publications and source records attributed to B H Walpoth.

At least 19 recordsLinked to original sources

Improved neo-endothelialization of small diameter ePTFE grafts with titanium coating.

BACKGROUND: Patency of small synthetic bypass grafts is inferior compared to autologous grafts for revascularization procedures. Titanium coating of foreign surfaces has shown to decrease thrombogenicity, enhance biocompatibility and promote adhesion of endothelial cells. The aim of this study was to test the effect of titanium coating of small diameter ePTFE grafts on short term patency, neo-endothelialization and neointimal proliferation. METHODS: Bilateral carotid graft interposition was performed in 5 pigs with uncoated (n=5) and titanium-coated (n=5) ePTFE grafts (internal diameter=4 mm, length=5 cm), thus each pig served as its own control. At the end of the study (30 +/- 3 days), patency and stenosis severity was assessed by carotid angiography. Animals were sacrificed and grafts were excised for histology and scanning electron microscopy. Morphometry of histologic sections was carried out to determine neointimal proliferation and percentage of neo-endothelial coverage. RESULTS: Patency rate was 80% for uncoated and titanium-coated grafts. Quantitative angiography did not show any significant difference in lumen size between two groups. Morphometry revealed a significantly higher cellular coverage with CD31 positive endothelial cells for titanium-coated (84 +/- 19%) than uncoated grafts (48 +/- 26%, p<0.001). There was a non significant trend (p=0.112) towards increased neointimal proliferation in titanium-coated (94 +/- 61 micron2/micron) compared to uncoated grafts (60 +/- 57 micron2/micron). CONCLUSIONS: Patency rate in uncoated and titanium-coated ePTFE grafts is similar at one month. However, titanium coated grafts show a significant improvement in neo-endothelialization compared to uncoated grafts.

Animals↗

PPS-PEG surface coating to reduce thrombogenicity of small diameter ePTFE vascular grafts.

AIMS: Patency failure of small vascular synthetic grafts is still a major problem for coronary and peripheral revascularization. Thus, three new surface coatings of small synthetic grafts were tested in an acute pig model to evaluate their thrombogenicity (extracorporeal arterio-venous shunt) and in a chronic rat model to evaluate the tissue reaction they induced (subcutaneous implantation). METHODS: In five domestic pigs (25-30 kg) an extracorporeal femoro-femoral arterio-venous shunt model was used. The study protocol included first a non-heparinized perfusion sequence followed by graft perfusion after 10,000 UI iv heparin. Grafts were perfused for 3 and 9 minutes. The following coatings were tested on ePTFE grafts: poly-propylene sulphide (PPS)--poly-ethylene glycol (PEG) (wet and dry applications) as well as carbon. Two sets of control were used, one dry and one wet (vehicle only). After perfusion grafts were examined by scanning electron microscopy for semi-quantitative assessment (score 0-3) of cellular and microthrombi deposition. To assess tissue compatibility, pieces of each material were implanted subcutaneously in 16 Wistar rats. At 2, 4, 8, 12 weeks four animals each were sacrificed for semi-quantitative (score 0-3) histologic evaluation of tissue reaction. RESULTS: In the pig model, cellular deposition and microthrombi formation increased over time. In non- heparinized animals, the coatings did not improve the surface characteristics, since they did not prevent microthrombi formation and cellular deposition. In heparinized animals, thrombogenicity was lowest in coated grafts,especially in PPS -PEG dry (p<0.05), and highest in controls. Cell deposition was lowest in PPS-PEG dry, but this difference was not statistically significant vs.controls. In the rat model,no significant differences of the tissue reaction could be shown between materials. CONCLUSION: While all coatings failed to add any benefit for lowering tissue reaction, surface coating with PPS -PEG (dry application) reduced thrombogenicity significantly (in heparinized animals) and thus appears to be promising for improving graft patency of small synthetic vascular prostheses.

Animals↗

Prevention of neointimal proliferation by immunosuppression in synthetic vascular grafts.

OBJECTIVE: Immunosuppressive agents have been proposed to reduce neointimal hyperplasia in synthetic vascular grafts. Thus, the purpose of the present study was to evaluate the safety and efficacy of rapamycins (systemic vs. local vs. oral administration) and mycophenolate mofetil (MMF) to reduce intimal hyperplasia in infrarenal synthetic vascular grafts of the rat. METHODS: Fifty-four Wistar rats (250 g) completed the study after a synthetic vascular graft (ePTFE, Gore-tex, 2 mm diameter, 10 mm length) was implanted end-to-end in the infrarenal aorta. The animals were divided into three groups: group 1 consisted of 12 control animals, group 2 consisted of 37 rats receiving rapamycins, either per os (RAD, 1.5 or 3 mg/kg), intraperitoneally (RPM, 1.5 or 3 mg/kg) or locally (RPM soaking of the graft); and in group 3 (n=5), MMF (40 mg/kg) was administered orally. The animals were followed weekly with weight controls and signs of toxicity for 30 (n=37) and 60 (n=17) days, respectively. All animals were sacrificed and underwent histological examination at completion of the study. RESULTS: All animals survived in groups 1 and 3, but five died in group 2. The weight gain was normal in all groups, except for the subgroup 2a receiving high dose rapamycins orally. All rats in group 3 suffered from diarrhea, whereas animals receiving high dose rapamycins showed toxic signs (hair loss, wound healing problems). Histological examination showed a significant increase in intimal hyperplasia in group 1 (0.03+/-0.01 and 0.14+/-0.05 microm after 30 and 60 days, respectively; P<0.01). Rapamycins in either application or dosage had no significant effect on intimal hyperplasia. CONCLUSIONS: Local or systemic administration of rapamycins has no effect on intimal hyperplasia in synthetic vascular grafts. In contrast, toxic signs with weight loss were observed in animals treated with high dose rapamycins, but not in those treated with MMF. Thus, in the rat model, immunosuppression with rapamycins or MMF cannot be recommended for the prevention of intimal hyperplasia in the synthetic vascular graft model.

Anastomosis, Surgical↗

Acute and chronic effects of transmyocardial laser revascularization in the nonischemic pig myocardium by using three laser systems.

BACKGROUND AND OBJECTIVE: Transmyocardial laser revascularization (TMLR) improves symptoms in patients with coronary heart disease. It is based on the hypothesis of direct perfusion of ischemic myocardium by means of laser-created channels. Three different lasers were used to study alternative effects on myocardium. STUDY DESIGN/MATERIALS AND METHODS: The present study was conducted to evaluate comprehensively and compare the short and long-term tissue effects and the basic interaction mechanisms of CO2, Ho:YAG, and Er:YAG laser radiation with myocardium. The dynamics of laser-induced impacts in gel used as tissue phantom was visualized by time-resolved flash photography. Pressure measurements performed during perforation of myocardium in vitro revealed the explosive character of the ablation process. Channels made into the left ventricle of normal pig hearts were examined immediately and 6 weeks after creation. RESULTS: Regardless of laser source, all channels became occluded within 6 weeks by scar. Minimal acute thermal damage by Er:YAG laser corresponded to smaller scars. Pulsed Ho:YAG caused stronger tissue tearing than continuous wave CO2 irradiation. An increased volume density of intramyocardial vessels was found about the scars 6 weeks after treatment with all lasers. CONCLUSION: The laser sources permitted to study outcome of pressure effects and thermal damage in vivo. There were only minor differences between the three laser systems used. Rapid channel occlusion suggests that rather than revascularization, subsidiary physiologic tissue effects elicited by the thermal, oxidative, or mechanical action of the laser impact may contribute to the beneficial clinical effects of TMLR.

Animals↗

Transit time flow measurement: experimental validation and comparison of three different systems.

BACKGROUND: Bloodflow measurements are of major clinical importance for quality control in vascular surgery. They allow detection of low-flow situations which may influence outcome adversely. The purpose of the present study was to validate three different flow systems for measuring absolute blood flow. METHODS: Measurements were performed in an experimental flow model using arteries and veins and blood or saline at two different temperatures. As a reference method true flow was measured by volume sampling. RESULTS: Correlation coefficients between transit time flow and true flow measurements ranged between 0.71 and 0.92. Systematic overestimation and underestimation of transit time flow were observed, but after second-order correction all correlations were excellent, ranging from 0.93 to 0.95 irrespective of flow medium and temperature. CONCLUSIONS: Transit time flow measurements are exact and reproducible. Second-order correction yields good accuracy and high precision, with minimal differences among the three systems evaluated.

Blood Flow Velocity↗

Evaluation of coronary bypass flow with color-Doppler and magnetic resonance imaging techniques: comparison with intraoperative flow measurements.

OBJECTIVES: After coronary artery bypass surgery, patency and flow assessment is based on invasive methods such as angiography and intravascular ultrasound or flow wire techniques. The aim of the study was to compare intraoperative transit time flow measurements of coronary bypass grafts with early postoperative color-Doppler and MR-imaging assessment. METHODS: In 22 patients (62+/-8.5 years) undergoing elective coronary bypass surgery the flow was measured in all internal mammary artery grafts (IMA) and saphenous vein grafts using the transit time flow technique. Postoperatively (days 5-7) all patients had a color-Doppler IMA graft assessment followed by a MR-angiography and flow measurement (navigator echo phase contrast technique with and without contrast bolus application) to determine patency and graft flow. RESULTS: Data are expressed as the mean +/- SD). (1) In all patients the left IMA graft to the left anterior descending coronary artery (LAD) could be identified and flow could be assessed with both color-Doppler and MRI. Venous grafts could only be visualized by MRI. The use of an intravenous contrast bolus enhanced the visualization of coronary artery bypass grafts. (2) The mean IMA to LAD flow was 33+/-17 ml/min intraoperatively by transit time and postoperatively 36+/-25 ml/min by MR respectively 66+/-54 ml/min by color-Doppler technique. (3) The systolic/diastolic flow ratio was 0.44+/-0.12 intraoperatively and 0.43+/-0.17 postoperatively by MR respectively 0.67+/-1.0 by color-Doppler. (4) A statistically significant correlation could be demonstrated between intraoperative transit time and postoperative MR flow measurements (r = 0.57; P < 0.04), whereas the correlations to color-Doppler flow were poor. Postoperatively MR and color-Doppler showed a good correlation of systolic/diastolic flow ratio (r = 0.88; P < 0.008). CONCLUSIONS: The color-Doppler method during echocardiography and MR-imaging are useful non-invasive techniques to visualize postoperative IMA grafts for patency assessment. The quantification of IMA flow is still difficult with either technique, but MR flow measurements showed the best correlation to the intraoperatively measured transit time flow. The MR technique is the most promising non-invasive method for postoperative evaluation of coronary bypass grafts, since it allows visualization and reliable flow quantification.

Blood Flow Velocity↗

Effects of unprocessed and processed cardiopulmonary bypass blood retransfused into patients after cardiac surgery.

BACKGROUND: The aim of this prospective study was to compare the effect of autologous unprocessed to processed residual cardiopulmonary bypass blood (CPB) on patients' laboratory and clinical parameters and outcome. METHODS: 20 patients undergoing elective coronary artery bypass surgery were randomized to receive either unprocessed CPB blood (control group) or processed CPB blood employing the Continuous AutoTransfusion System (CATS; Fresenius, Bad Homburg, Germany). We have shown that this method eliminated >93% of activated mediators. Serial laboratory parameters including complement activation, coagulation factors and the stimulation of IL-6 and IL-8 were compared with clinical side effects and patients' outcome. RESULTS: Compared to control patients, retransfusion of unprocessed CBP blood significantly increased heparin, free plasma hemoglobin and D-Dimers. Postoperatively, three patients in the control group and two patients in the CATS group required prolonged mechanical ventilation or developed infections associated respectively with elevated C3a (desArg) or IL-6 concentration. CONCLUSIONS: CATS-processing of CPB blood provided a high-quality red blood cell concentrate, resulting in a reduced load of retransfused activated mediators.

Blood Coagulation Factors↗

Improvement of patency rate in heparin-coated small synthetic vascular grafts.

BACKGROUND: Graft thrombosis and intimal hyperplasia represent the major causes of graft failure. Heparin has been shown to have a beneficial effect on long-term patency and on prevention of intimal hyperplasia. Thus, the purpose of the present study was to evaluate the effect of heparin coating on patency rate and intimal hyperplasia in small synthetic vascular grafts. METHODS AND RESULTS: Two synthetic grafts (expanded polytetrafluoroethylene [ePTFE], and polyurethane) with and without heparin coating were implanted in the infrarenal aorta (diameter, 2 mm) of 40 Whistar rats. Animals survived 8 weeks after implantation. Graft patency, intimal thickness, and percentage of diameter stenosis were determined by light microscopy at the proximal respectively distal anastomosis and in the middle of the graft. Uncoated grafts showed a patency rate of 70% for ePTFE and 60% for polyurethane grafts. Heparin-coated grafts showed a patency rate of 100% for ePTFE and 90% for polyurethane grafts. Intimal hyperplasia was observed in all grafts mainly at the anastomosis site. Intimal wall thickness and percentage of stenosis were significantly more pronounced in the polyurethane than ePTFE grafts (P < 0.01). Heparin coating significantly reduced overall graft thrombosis (P < 0.05) but had no significant effect on intimal hyperplasia. CONCLUSIONS: Small grafts show a high rate of graft thrombosis and an enhanced intimal hyperplasia. ePTFE grafts show significantly less intimal hyperplasia and percentage of stenosis than polyurethane grafts. Heparin coating significantly reduced graft thrombosis but had no significant effect on intimal hyperplasia. Thus, heparin coating seems to be beneficial for graft patency, and ePTFE appears to be superior to polyurethane as graft material.

Animals↗

Assessment of troponin-T for detection of clinical cardiac rejection.

Non-invasive detection of cardiac rejection still remains a challenge after heart transplantation. We assessed troponin-T as a new serum marker to diagnose cardiac rejection. Twenty-five heart transplant patients (Berne) were monitored prospectively for up to 2 years, and compared to 89 retrospectively assessed patients (Stanford). Blood samples (392 Berne and 320 Stanford) were analyzed (creatine kinase, isoenzymes MB activity and MB mass, troponin-T and troponin-I). Regression analysis between the results of these blood samples and cardiac rejection grading from simultaneously performed endomyocardial biopsies was carried out. Troponin-T tests done in two different laboratories showed a good correlation (r = 0.91; P < 0.0001), whereas troponin-T versus troponin-I showed a lower correlation (r = 0.53; P < 0.0001). Troponin-T and -I in contrast to other enzymes were elevated for a longer period (up to 4 weeks before returning to baseline) after transplantation than during conventional cardiac surgery. Beyond 3 months the following correlations were found between troponin-T (new or old test) and the other enzymes (creatine kinase: r = 0.26, MB activity: r = 0.4, and MB mass: r = 0.68). The correlation between the degree of rejection and the enzyme release is poor, however, the best results were obtained for troponin-T (r = 0.22; P < 0.001). We found a low correlation between troponin-T and the degree of rejection beyond 3 months after heart transplantation. Despite a troponin-T elevation in some patients with rejection, the new test is not sensitive enough to be used alone for the non-invasive diagnosis of cardiac rejection.

Biomarkers↗

Transit-time flow measurement for detection of early graft failure during myocardial revascularization.

BACKGROUND: A low-flow situation in arterial and venous grafts has been associated with high rates of perioperative infarction and mortality. This study was designed to look at intraoperative graft flow and resistance in patients with coronary artery disease. METHODS: Coronary artery bypass graft flow was measured in 46 patients. Transit-time flow was used for coronary flow measurements at rest as well as after maximal vasodilation with adenosine infusion. RESULTS: Forty-three of the 46 patients showed normal internal mammary artery graft flow (>20 mL/min); 3 patients had no or minimal graft flow. Redoing the graft anastomosis in these 3 patients resulted in normalization of graft flow. The mean flow increased significantly after correction from 0.5 +/- 0.7 mL/min to 15.7 +/- 9.6 mL/min (p < 0.02). Conversely, vascular resistance decreased significantly from 138 +/- 10 to 4.8 +/- 1.8 Ohmv (p < 0.0001), as did the pulsatility index (from 146.9 +/- 95.7 to 3.4 +/- 1.8; p < 0.001). After correction, coronary flow reserve was 2.5 +/- 1.1. CONCLUSIONS: Measurements of intraoperative flow and resistance as well as derived variables allow assessment of early graft function and thus help prevent graft failure and reduce perioperative infarction. Transit-time volume flow might be a simple tool for quality control in coronary bypass procedures.

Anastomosis, Surgical↗

Failed coronary artery bypass anastomosis detected by intraoperative coronary flow measurement.

OBJECTIVES: To assess intraoperative flow of arterial and venous coronary grafts after myocardial revascularization which may allow early detection of low flow situations, especially during minimally invasive coronary bypass surgery (MIDCAB), and lead to immediate correction of technical problems. METHODS: In two patients with severe and diffuse multi-vessel disease the left internal mammary artery (IMA) was connected to the left anterior descending artery (LAD). During reperfusion, the flow was measured in the IMA and vein grafts using a transit time flow meter. RESULTS: In both cases the IMA showed only a systolic pendulating flow curve with a mean flow of 0-1 ml/min and a high resistance. Manual IMA assessment revealed an adequate pulsation. Both distal IMA anastomoses were re-explored on cardiopulmonary bypass yielding an initial flow of 7 and 14 ml/min, respectively. After treatment with papaverine/adenosine the IMA flow increased from 7 to 26 ml/min (coronary flow reserve (CFR) = 3.7) and from 14 to 46 ml/min (CFR = 3.3), respectively. CONCLUSION: Intraoperative flow assessment of IMA and venous bypass grafts can be recommended to monitor flow; especially during MIDCAB procedures.

Aged↗

Assessment of cardiac rejection by MR-imaging and MR-spectroscopy.

BACKGROUND: Detection of cardiac rejection is a major problem in cardiac transplantation. The gold standard is, and remains, endomyocardial biopsy. PURPOSE: Evaluation of MR-imaging and MR-spectroscopy for detection of cardiac rejection. METHODS: Orthotopic cardiac transplantation (HTX) was performed in 13 pigs (body weight 30 kg). All animals obtained immunosuppressive (triple) therapy for 1 week after the operation. Thereafter immunosuppression was stopped to induce cardiac rejection. MRI and MRS (1.5 Tesla General Electrics Signa) were performed pre- and post-operatively on days 10, 17, 24 and 31. The degree of rejection was determined post-operatively using endomyocardial biopsy (Texas grading score). RESULTS: (1) MR-imaging: LV function remained unchanged after HTX. LV mass increased (+42%; P < 0.05) with cardiac rejection. (2) MR-spectroscopy: a marked reduction in the ratio of phosphocreatine and adenosine triphosphate, respectively, to inorganic phosphate was observed in the rejecting hearts. (3) Histologic grading confirmed cardiac rejection after stopping immunosuppression. The Texas score was 5.7+/-0.8 at autopsy. CONCLUSIONS: MR-imaging and MR-spectroscopy allow the detection of changes associated with cardiac rejection. Both techniques are correlated with histologic rejection. However, endomyocardial biopsy remains the gold standard for reliable detection of cardiac rejection.

Adenosine Triphosphate↗

Left heart bypass in the pig with a centrifugal pump using cannulae prepared for percutaneous placement.

A rapid and efficient circulatory support system may save a patient in cardiogenic shock. Left heart bypass with percutaneous and trans-septal placement of the aspiration cannula simplifies the circuit and eliminates the need for an oxygenator. In this pre-clinical study we assessed left heart bypass support with a centrifugal pump using new cannulae prepared for percutaneous placement (14 F arterial catheter and 16 F left atrial aspiration line) in 5 anaesthetized pigs. Animals were supported for two hours at a mean flow of 3.2 l/min (4,033 rpm), a mean haematocrit of 29% and low heparinisation (ACT double baseline). Hemodynamic measurements and blood samples were taken at baseline (A), 10 minutes (B), one hour (C) and 2 hours (D) on support. Results show maintenance of hemodynamic parameters throughout the 2 hour support period. Only systolic arterial and left ventricular pressure decreased by 12% and 20% respectively from baseline to the end of the support period with a 13% increase in cardiac output. When the pump was turned on (0-3 l/min) there was usually a decrease in heart rate, systolic pressure and left ventricular pressure, with unchanged cardiac output (non failing model). Potassium increased from 3.9 to 4.2 mmol/l (ns), and plasma hemoglobin from 6.0 to 18.2 mg/dl (p<0.05). Thrombocytes decreased from 187 to 155 10(9)/l (ns). In conclusion, this preclinical study demonstrated the feasibility of an efficient left heart bypass of short duration with a centrifugal pump using cannulae prepared for percutaneous placement. Left heart bypass was well tolerated hemodynamically and no significant laboratory change occurred within the two hours of support. This opens several possibilities for the short term support of patients in cardiogenic shock and eventually also for patients submitted to minimally invasive cardiac surgery.

Animals↗

Outcome of survivors of accidental deep hypothermia and circulatory arrest treated with extracorporeal blood warming.

BACKGROUND: Cardiopulmonary bypass has been used to rewarm victims of accidental deep hypothermia. Unlike other rewarming techniques, it restores organ perfusion immediately in patients with inadequate circulation. This study evaluated the long-term outcome of survivors of accidental deep hypothermia with circulatory arrest who had been rewarmed with cardiopulmonary bypass. METHODS: Deep hypothermia (core temperature, <28 degrees C) with circulatory arrest was found in 46 of 234 patients with accidental hypothermia. In 32 of the 46 patients, rewarming with cardiopulmonary bypass was attempted, resulting in 15 long-term survivors. In most of these patients, deep hypothermia developed after mountaineering accidents or suicide at tempts. After an average (+/-SD) of 6.7+/-4.0 years of follow-up, we obtained the patients' medical histories and performed neurologic and neuropsychological examinations, neurovascular ultrasound studies, electroencephalography, and magnetic resonance imaging of the brain. RESULTS: The average age of the patients was 25.2+/-9.9 years; seven were female and eight were male. The mean interval from discovery of the patient to rewarming with cardiopulmonary bypass was 141+/-50 minutes (range, 30 to 240). At follow-up there were no hypothermia-related sequelae that impaired quality of life. Neurologic and neuropsychological deficits observed in the early period after rewarming had fully or almost completely disappeared. One patent had cerebellar atrophy on magnetic resonance imaging with mild clinical signs, a condition that may have been caused by hypothermia. Other clinical abnormalities were either preexisting or due to injuries not related to hypothermia CONCLUSIONS: This clinical experience demonstrates that young, otherwise healthy people can survive accidental deep hypothermia with no or minimal cerebral impairment, even with prolonged circulatory arrest. Cardiopulmonary bypass appears to be an efficacious rewarming technique.

Accidents↗

Qualitative assessment of blood washing with the continuous autologous transfusion system (CATS)

A number of different blood-processing methods can be used at the end of cardiopulmonary bypass (CPB) to improve the quality of autologous blood. They include centrifugation, hemofiltration and cell-washing. They differ in processing time required, cost of disposables and the quality of the processed autologous blood product. The newly developed continuous auto-transfusion system (CATS: Fresenius AG, Bad Homburg) uses a continuous cell-washing method. In a prospective study, the oxygenator blood of 10 patients was processed at the end of cardiac surgery with CATS and the quality of autologous blood before and after processing was compared. The processing volumes and the time required were recorded. The concentrations and elimination rates of blood parameters and waste products such as activated coagulation and complement products were measured. At the end of CPB a mean volume of 1,010 +/- 174 ml diluted oxygenator blood was processed and concentrated to 310 +/- 88 ml in 11.0 +/- 2.2 mins. Cellular elements such as erythrocytes and leucocytes were mostly retained and their concentration showed a significant increase after processing (250% and 210% respectively; p < 0.01). Thus, the blood processing with CATS resulted in an excellent hemoconcentration (hematocrit 62 +/- 3 vs. 24 +/- 4% before processing) with a consistent reproducibility. On the other hand, the CATS concentrate showed a significant loss of autologous plasma proteins. Likewise, all water soluble elements such as waste products are significantly lower in concentration after processing and, if calculated by quantity, they show a high elimination rate (> 93%). In conclusion, the continuous autologous transfusion system permits an automated, rapid and continuous processing of autologous blood yielding a standardised high quality erythrocyte concentrate.

Aged↗

[Effect of postoperative retransfusion of autologous blood products on hemostasis in heart surgery].

In cardiac surgery a reduction of homologous blood products is mainly achieved by autologous blood salvage. Unprocessed retransfusion of autologous blood may induce changes in hemostasis. We assessed changes of activated clotting times (ACT) after retransfusion of unprocessed (1) oxygenator blood and (2) shed mediastinal blood. In 41 patients undergoing cardiac surgery (37 revascularization and 4 valve procedures) with a mean cardiopulmonary bypass time of 116.3 min, ACT was measured at the following time points: pre- and postoperatively, and before and after retransfusion of oxygenator blood and shed mediastinal blood. A significant prolongation of ACT values was only seen between pre- to postoperative blood (p < 0.003). Retransfusion of oxygenator blood changed ACT from 120 +/- 25 vs 116 +/- 17 sec and retransfusion of shed mediastinal blood showed a mean ACT of 118 +/- 14 vs 115 +/- 20 sec from before to after transfusion. There was a significant correlation between the ACT value in the unprocessed oxygenator blood and the ACT value measured in the patient after retransfusion (r = 0.41, p < 0.02). 6 patients receiving over 1 litre of unprocessed autologous blood (either from the oxygenator or the mediastinum) in less than 60 minutes showed a significant increase of ACT value after transfusion (p < 0.05). Hence, under normal conditions, retransfusion of unprocessed autologous blood will not significantly alter hemostasis measured by the ACT test in patients undergoing cardiac surgery.

Adult↗