PubMed Health⌕ Search

Biomedical subjects

B Holland

Publications and source records attributed to B Holland.

At least 37 records · Page 2Linked to original sources

Chiropractic biophysics digitized radiographic mensuration analysis of the anteroposterior lumbopelvic view: a reliability study.

OBJECTIVE: To investigate the reliability of a radiographic measurement procedure that uses a computer and sonic digitizer to determine projected spinal displacements from an ideal normal position. DESIGN: A blind, repeated-measure design was used. Anteroposterior lumbopelvic radiographs were presented to each of 3 examiners in random order. Each film was digitized, and the films were randomized for a second run. SETTING: Private, primary-care chiropractic clinic. MAIN OUTCOME MEASURES: The angle of the sacral base in comparison to a true horizontal line (horizontal base angle), lumbodorsal angle, lumbosacral angle, and the thoracic translational displacement from true vertical determined as the perpendicular distance from the center of T12 to a vertical axis line drawn from the center of the S1 spinous process cephalad and parallel to the lateral edge of the x-ray film. RESULTS: Intraexaminer reliability for the (a) horizontal base angle was .72 to .94, with confidence intervals included in the range of .52 to .97; (b) lumbodorsal angle was .90 to .96, with confidence intervals in the range of .82 to .98; (c) lumbosacral angle was .84 to .96, with confidence intervals in the range of .72 to .98, and (d) thoracic translational displacement from vertical was .95 to.97, with confidence intervals included in the range of .91 to .99. Interexaminer reliability for the three examiners ranged from .71 to .97. CONCLUSIONS: Measures similar to those described in this study are commonly used to measure and categorize spinal displacements from true vertical alignment (ie, scoliosis measurements). Most patient assessment methods used in chiropractic have poor or unknown reliability. The one possible exception to this rule is spinal displacement analysis performed on radiographs. In chiropractic, intraclass correlation coefficients values greater than .70 are considered accurate enough for use in clinical and research applications. The measures tested here would fit within these guidelines of reliability. Establishing reliability is an important first step in evaluating these measures so that future studies of validity may be undertaken.

Analysis of Variance↗

High-pressure, rapid-inflation pneumatic compression improves venous hemodynamics in healthy volunteers and patients who are post-thrombotic.

PURPOSE: Deep vein thrombosis (DVT) is a preventable cause of morbidity and mortality in patients who are hospitalized. An important part of the mechanism of DVT prophylaxis with intermittent pneumatic compression (IPC) is reduced venous stasis with increased velocity of venous return. The conventional methods of IPC use low pressure and slow inflation of the air bladder on the leg to augment venous return. Recently, compression devices have been designed that produce high pressure and rapid inflation of air cuffs on the plantar plexus of the foot and the calf. The purpose of this study is to evaluate the venous velocity response to high-pressure, rapid-inflation compression devices versus standard, low-pressure, slow-inflation compression devices in healthy volunteers and patients with severe post-thrombotic venous disease. METHOD: Twenty-two lower extremities from healthy volunteers and 11 lower extremities from patients with class 4 to class 6 post-thrombotic chronic venous insufficiency were studied. With duplex ultrasound scanning (ATL-Ultramark 9, Advanced Tech Laboratory, Bothell, Wash), acute DVT was excluded before subject evaluation. Venous velocities were monitored after the application of each of five IPC devices, with all the patients in the supine position. Three high-pressure, rapid-compression devices and two standard, low-pressure, slow-inflation compression devices were applied in a random sequence. Maximal venous velocities were obtained at the common femoral vein and the popliteal vein for all the devices and were recorded as the mean peak velocity of three compression cycles and compared with baseline velocities. RESULTS: The baseline venous velocities were higher in the femoral veins than in the popliteal veins in both the volunteers and the post-thrombotic subjects. Standard and high-pressure, rapid-inflation compression significantly increased the popliteal and femoral vein velocities in healthy and post-thrombotic subjects. High-pressure, rapid-inflation compression produced significantly higher maximal venous velocities in the popliteal and femoral veins in both healthy volunteers and patients who were post-thrombotic as compared with standard compression. Compared with the healthy volunteers, the patients who were post-thrombotic had a significantly attenuated velocity response at both the popliteal and the femoral vein levels. CONCLUSION: High-pressure, rapid-inflation pneumatic compression increases popliteal and femoral vein velocity as compared with standard, low-pressure, slow-inflation pneumatic compression. Patients with post-thrombotic venous disease have a compromised hemodynamic response to all IPC devices. However, an increased velocity response to the high-pressure, rapid-inflation compression device is preserved. High-pressure, rapid-inflation pneumatic compression may offer additional protection from thrombotic complications on the basis of an improved hemodynamic response, both in healthy volunteers and in patients who were post-thrombotic.

Adult↗

Mastery of fundamental motor skills among New South Wales school students: prevalence and sociodemographic distribution.

Mastery of fundamental motor skills among children and adolescents is a potentially important contribution to satisfying participation in sports, games and other physical activities and may enhance the development of an active lifestyle. However, few attempts have been made to determine the prevalence of fundamental motor skill mastery among young Australians. The NSW Schools Fitness and Physical Activity Survey, 1997 (N = 5518) randomly selected schools proportionally from all three education sectors and selected students in Years 4, 6, 8 and 10. Performance on six fundamental motor skills (run, vertical jump, catch, overhand throw, forehand strike and kick) was assessed qualitatively. The prevalence of mastery and near mastery of each skill and mastery of each skill component is reported for boys and girls in each school year. The findings indicate that the prevalence of mastery and near mastery of each of the fundamental motor skills was generally low. There were no differences between students from urban or rural schools and the prevalence of skill mastery was directly associated with socioeconomic status more consistently among girls than among boys. Greater curriculum time and resourcing and training of teachers is required to increase the proportion of students who have mastered the skills fundamental to common sports, games and other physical activities.

Female↗

Further analysis of the reliability of the posterior tangent lateral lumbar radiographic mensuration procedure: concurrent validity of computer-aided X-ray digitization.

OBJECTIVE: To investigate the reliability of a specific method of radiographic analysis of the geometric configuration of the lumbopelvic spine in the sagittal plane, and to investigate the concurrent validity of a computer-aided digitization procedure designed to replace the more tedious and time-consuming manual measurement process. DESIGN: A blind, repeated-measures design was used. The results of radiographic measures derived through the traditional manual marking method were compared with measures derived by computer-aided digitization of lateral lumbopelvic radiographs. SETTING: Private chiropractic clinic. MAIN OUTCOME MEASURES: Pearson's product-moment correlation coefficients, paired sample t tests and intraclass correlation co-efficients (ICC) were used to examine intraexaminer reliability, and repeated measures of analysis of variance were used to examine interexaminer reliability for relative rotation angles for T12-L1, L1-L2, L2-L3, L3-L4, L4-L5, L5-S1, overall lordosis measurement [absolute rotation angle (ARA)] from L1-L5 and Cobb angle of overall lordosis measured from the inferior surface of T12 to the superior surface of S1, Ferguson's sacral base angle to horizontal, angle of pelvic tilt (arcuate angle) to horizontal and anteroposterior thoracic translation (Sz) in millimeters. RESULTS: ICC estimates for intraexaminer reliability were in the range of 0.96-0.98 for the L1-L5 ARA, a range of 0.87-0.99 for the arcuate angle measurement, 0.83-0.94 for the Ferguson's angle measurement, 0.88-0.95 for the Cobb angle measurement from the inferior surface of T12 compared with the superior surface of S1 and 0.98-1.00 for the translation measurement of the lower thoracic spine to S1 (Sz). The intersegmental measurement's (T12-L1, L1-L2, L2-L3, L3-L4, L4-L5, L5-S1) correlations ranged from a low of 0.55 to a high of 0.97. Examination of these findings suggests that the reliability for the three doctors is acceptable with only the T12-L1 intersegmental measure falling below 0.70 for the least experienced examiner. Average ICC of interexaminer reliability for manual and computer-aided digitizing examiners were the following: 0.96 for the L1-L5 ARA; 0.84 for the arcuate angle measurement; 0.82 for the Ferguson's angle measurement; 0.88 for the Cobb angle measurement; 1.00 for the Sz translation measurement; and values of 0.65, 0.73, 0.74, 0.75, 0.89 and 0.81 for relative rotation angle measurements T12-L1, L1-L2, L2-L3, L3-L4, L4-L5 and L5-S1, respectively. CONCLUSION: The data tend to support the reliability of this method of radiographic analysis of the geometric configuration of the lumbopelvic spine as viewed on lateral lumbopelvic radiographs. The additional data presented here tend to support the concurrent validity of the computer-aided digitization method of analysis inasmuch as the measures determined by the digitizing examiners are essentially identical to those determined by the manual method plus or minus the average standard error of measure of each value.

Humans↗

Elliptical modeling of the sagittal lumbar lordosis and segmental rotation angles as a method to discriminate between normal and low back pain subjects.

Clinical significance of lumbar lordosis has not been agreed on. Our purpose is to compare lordotic measurements of normal and pain subjects and to test the validity of a new anthropometric model of lumbar curvatures. Digitized radiographic points (body corners) from standing lateral lumbar radiographs were modeled with ellipses in a least-squares method and were used to create segmental angles, a global angle at L1-L5, a Cobb angle from T12 to S1, Ferguson's sacral base angle, and an angle of pelvic tilt. Fifty normal subjects were matched in age, sex, weight, and height with 50 acute pain subjects, 50 chronic pain subjects, and 24 pain subjects with radiographic abnormalities. Of 11 angles, 2 distances, and 2 ratios, statistical analysis was significantly different across groups for 12 of these measurements, with the alternative hypotheses accepted for the other 3 measurements. The lordosis of both normal and low back pain subjects can be successfully modeled with a portion (approximately 86 degrees) of an ellipse, but with different major and minor axis ratios. The normal group's average elliptic lordosis has the smallest least-squares error, approximately 1 mm per digitized point, with (minor axis)/(major axis) ratio = 0.39, L1-L5 global angle = 40 degrees, and Cobb angle = 65 degrees. The chronic and radiographic abnormalities pain groups have an elongated ellipse with hypolordosis, reduced L1-L5 global angle = 29.6-35 degrees, reduced Cobb angle = 57-58 degrees, and elliptic axis ratio = 0.27-0.30. The acute pain group is hyperlordotic with the largest L1-L5 global angle, largest Cobb angle = 70 degrees, largest Ferguson's angle, and largest pelvic tilt angle.

Acute Disease↗

Quantitative determination of surface antibody binding capacities of immune subsets present in peripheral blood of healthy adult donors.

The objective of this study was to quantitate the antibody binding capacity (ABC) of CD3, CD4, CD8, CD16, and CD19 on lymphocytes and CD4 on monocytes from healthy adult donors. Peripheral blood was collected over three consecutive days and repeated in the same format two weeks later for comparison to initial measurements. Immune subsets were labeled by direct single or two-color staining in whole blood followed by lysis of erythrocytes. Fluorescence intensity measurements were made by carefully calibrating the flow cytometer and then measuring the intensity of monoclonal antibody staining on labeled cells and on Quantum Simply Cellular Microbeads. The effect of paraformaldehyde fixation on intensity measurements and coefficient of variation of thirty replicates for each phenotype were also studied. We found a small change in calculated ABC following overnight fixation with a greater change following 48 h of fixation prior to flow cytometric analysis. We found excellent precision could be achieved for measuring the ABC of most markers with some improvement desirable for expression of CD4 on monocytes and CD16+ lymphocytes. Between donors we found a high-low range of CD3+ = 134,349-45,905; CD4+ (lymphocytes) = 54,174-36,106; CD4+ (monocytes) = 9,246-3094; CD8+ = 268,868-190,622; CD3+CD8+ = 269,858-212,024; CD16+ = 38,307-336; and CD19+ = 25,252-11,689. For the total donor group, the observations at week 1 and week 2 were not significantly different (alpha = .05) for any of the immunophenotypes we studied. The data presented here continue to show that it is possible to perform quantitative intensity measurements of immune subsets when performing immunophenotyping studies.

Adult↗

Comparisons of lordotic cervical spine curvatures to a theoretical ideal model of the static sagittal cervical spine.

STUDY DESIGN: Measurements from lateral cervical radiographs of randomly selected patients are compared with two proposed ideal models. OBJECTIVES: To evaluate lordotic cervical curvatures from a large population base, to provide a geometric sagittal cervical spine model, and to test the validity of the model to predict measured angles and distances. Averages of ranges and normal values for cervical lordosis under conditions of static equilibrium are sought. SUMMARY OF BACKGROUND DATA: Seven angles and three distances were taken from 400 randomly selected lateral cervical radiographs of patients at a private clinic. METHODS: The radiographic measurements are compared with predicted values from our geometric sagittal cervical spine model and the Delmas ideal cervical model. RESULTS: Values were predicted successfully by the geometric model with an average error of 5% compared with the radiographic measurements. The range of lordosis, measured at the posterior of C2 and C7, was 16.5-66 degrees, with a mean of 34 degrees. The average height-to-length ratio for the cervical spine was 0.97. CONCLUSIONS: Predicted values from the geometric model were comparable with the measurements of the relative rotation angles at each vertebral interspace, absolute rotation angles from C2 to C7, and height-to-length ratios. A cervical lordosis of 34 degrees and a height-to-length ratio of 0.97 are suggested for clinical and theoretical outcomes.

Adult↗

Intra- and interexaminer reliability of the chiropractic biophysics lateral lumbar radiographic mensuration procedure.

OBJECTIVE: To determine the intra- and interexaminer reliability of a specific method of mensuration commonly used to evaluate the positional configuration of the lumbopelvic spine viewed on lateral lumbar radiographs. DESIGN: A blind, repeated-measures design was used. Lateral lumbopelvic radiographs were presented to each of three examiners in random order. Each film was marked and measurements were recorded. The films were cleaned of all markings and randomized again for a second run by each examiner. Each examiner's measurements were unavailable to the other examiners. SETTING: Private, primary-care chiropractic clinic. MAIN OUTCOME MEASURES: Anterior/posterior thoracic translation in millimeters, Ferguson's sacral-plane angle to horizontal, arcuate line angle to horizontal, L1 to L5 absolute rotation angle and four relative rotation angles for L1-L2, L2-L3, L3-L4 and L4-L5. Intra- and interrelibility of the three radiographic examiners were analyzed. RESULTS: Intraexaminer reliability for (a) L1-L5 absolute rotation angle was .98, with confidence intervals included in the range of 0.95-0.99, (b) anterior/posterior thorax translation [+/- Sz] was .97-.99, with confidence intervals included in the range of 0.94-1.00, (c) arcuate angle (AA) .40-.81, with confidence intervals included in the range of 0.07-0.90, (d) Ferguson's angle (FA) was .91-.97, with confidence intervals included in the range of 0.82-0.98, (e) relative rotation angle reliability ranges were L1-L2, .84-.94; L2-L3, .80-.85; L3-L4, .78-.89; L4-L5, .87-.92. Interexaminer reliabilities for the three examiners ranged from .66-.98. CONCLUSION: With the exception of the arcuate angle measurement, the reliabilities for all other measurements were at least .78. Those measurements with reliabilities approaching .80 or better would be considered accurate enough for use in future clinical studies. The arcuate angle measurement may have been least reliable because of the subjective nature of the method of affixing a best-fit line to a radiographic landmark that often takes on the appearance of a mild curvature. Establishing reliability is an important first step toward evaluating these and other similar radiographic measurements that have yet to be examined for their validity.

Analysis of Variance↗

A step-down procedure for multiple tests of treatment versus control in each of several groups.

Cheung and Holland extended Dunnett's treatment versus control multiple comparison procedure to the case of several groups. Dunnett and Tamhane provided a step-down procedure more powerful than that of Dunnett for situations where the researcher's interest is in testing and not in simultaneous confidence interval estimation. In this paper we show how one can use the approach of Dunnett and Tamhane to devise a testing procedure for the multi-group problem with power greater than that of Cheung and Holland. We illustrate the new procedure with reanalyses of published data from a clinical experiment.

Confidence Intervals↗

Pertussis immunisation in children with a family or personal history of convulsions: a review of children referred for specialist advice.

Recent guidelines recommend that children with a family or personal history of convulsions should receive all vaccinations. To determine vaccination status and adverse events following vaccination, questionnaires were sent to the general practitioners of 83 children referred for specialist advice between January 1988 and June 1991 in Redbridge Health Authority. Details of consultations within seven days of vaccination, and of any subsequent neurological or developmental problems were collected. Follow-up data were obtained for 77 of the 83 children (93%); 66 of whom had a family history, and 11 a personal history, of convulsions. Of the 66 children with a family history of convulsions, 57 received pertussis-containing vaccines, of whom one child was reviewed for a possible neurological event. Of the nine remaining children who received diphtheria-tetanus (DT) only vaccine, two children were reviewed for possible neurological events. Of the 11 children with a personal history of convulsions, nine received pertussis-containing vaccines and two received DT vaccines; none had any further neurological event. At late follow-up, none of the 77 children vaccinated had developed recurrent convulsions or any other neurological or developmental problems. Children with a family or personal history of convulsions who are given pertussis-containing vaccines seem unlikely to suffer adverse events or long-term neurological sequelae, and should be considered for all routine vaccinations in line with current recommendations.

Child↗

Enzyme immunoassay for detection of human immunodeficiency virus-specific immunoglobulin A antibodies.

Early diagnosis of human immunodeficiency virus (HIV) infection may be difficult in adults with acute or recent HIV infection and in infants with perinatally acquired HIV. Detection of HIV-specific immunoglobulin A (IgA) antibodies in infant serum by Western blot (immunoblot) has been suggested as a reliable method to identify HIV-infected infants, especially those over the age of 6 months, and as an adjunct to diagnosis of acute HIV infection in adults. We developed a simple enzyme immunoassay for detection of HIV-specific IgA, using standard commercially available reagents. Enzyme immunoassay was comparable to Western blot for detection of HIV-specific IgA in sera from adults (n = 216), older children (n = 49), and infants born to HIV-infected mothers (n = 65). Specificity was 100% and sensitivity ranged from 80 to 92%. IgA-enzyme immunoassay is a simple, highly sensitive method for detection of HIV-specific IgA antibodies and is easily adapted to the standard clinical laboratory.

Adolescent↗

Nontuberculous mycobacteria in children with acquired immunodeficiency syndrome.

Among 139 children with acquired immunodeficiency syndrome at Children's Hospital of New Jersey, 20 had positive cultures for non-tuberculous mycobacteria. Eighty-five percent had Mycobacterium avium complex isolated and 70% had definite evidence of disseminated disease. Ninety-three percent had CD4 lymphocyte counts less than 100 cells/mm3 and 95% had met acquired immunodeficiency syndrome criteria before the time of first positive culture. Clinical findings included failure to gain weight, anorexia, fever, abdominal pain/tenderness and anemia. The median age at onset of symptoms was 46 months and the median time between onset of symptoms and positive culture was 9 months. Outcome for patients with positive cultures for nontuberculous mycobacteria was poor, with 75% of the children surviving for less than or equal to 10 months. Nontuberculous mycobacteria are increasingly important causes of morbidity and indirect mortality in human immunodeficiency-infected children. Children with severe immunodeficiency are at particular risk. In addition to M. avium complex, other species of nontuberculous mycobacteria may be involved.

Acquired Immunodeficiency Syndrome↗

Clinical and laboratory correlates of Pneumocystis carinii pneumonia in children infected with HIV.

The case histories of 27 children with Pneumocystis carinii pneumonia (PCP) who were followed up in the AIDS Program at the Children's Hospital of New Jersey, Newark, are reviewed. The mean and median age at PCP diagnosis were 10.8 and 7.7 months, respectively. All of the children had other clinical evidence of infection with the human immunodeficiency virus that was documented prior to the diagnosis of PCP or found at the time of PCP diagnosis. Most patients who presented to the hospital were acutely ill, and complications of treatment occurred in 70%. Overall, 89% of the patients died and 70% survived for less than 6 months after diagnosis of PCP. Median survival after the diagnosis of PCP was only 2.0 months and the median life span of children with PCP was only 14.4 months. Only 40% of children with PCP had CD4 lymphocyte counts at or below the threshold for institution of PCP prophylaxis in adults of 200 x 10(6) cells/L (200 cells/mm3).

CD4-Positive T-Lymphocytes↗

Control of the bacterial cell cycle.

New insights into the control of DNA replication through growth, hemimethylated DNA and DnaA protein have been described. Fundamental shifts in thinking have resulted in the identification of new cell cycle genes with potential roles in initiation of DNA replication, chromosomal segregation and division. Excitingly, this trend may also narrow the apparent differences between the prokaryotic and eukaryotic cell cycles.

Cell Cycle↗

Development of sugar-induced blood pressure elevation after uninephrectomy in a resistant rat strain.

Certain rat strains acutely increase blood pressure (BP) when given diets high in NaCl. Prior results showed that "salt-sensitive" rat strains, at least the ones studied, also increase BP in response to sugar loading. To examine this relationship further and learn more about the pathogenesis of sucrose-induced BP elevations, we examined the effects of unilateral nephrectomy (uninephrectomy) on sucrose-induced BP changes. The rationale is based upon the findings that renal mass removal sensitizes BP response to salt loading. Over 15 weeks, augmented sugar (sucrose) consumption by Long-Evans (LE) rats did not increase BP markedly compared to rats consuming a diet relatively low in sugar unless uninephrectomy was performed. The differences in BP caused by the high sugar diet in a uninephrectomized rat could not be explained adequately by alterations in catecholamine excretion, plasma renin activity, excesses in blood volume, or the other parameters examined. However, salt-induced hypertension has been attributed to the presence of circulating substances affecting ion transport. Among the dietary groups, there was a significant correlation between the ability of plasma to depress PAH and TEA renal slice uptake and the difference in BP. This is consistent with the presence of a circulating factor affecting cell transport that has its greatest activity in the high sugar-uninephrectomy group of LE rats. We conclude that reducing renal mass potentiates sugar-induced BP elevation similar to salt-induced BP elevation in a normally resistant rat strain, and the rise of BP may be caused by a circulating factor.

Aging↗

Influence of oat bran on sucrose-induced blood pressure elevations in SHR.

To determine whether oat fiber influences BP, we gave spontaneously hypertensive rats (SHR) a diet high in sucrose and low in protein (calories: sucrose 52%, protein 15%, fat 33%) or a diet low in sucrose and high in protein (calories: sucrose 13%, protein 52%, fat 35%). The amount of fat in these particular diets has not been shown to influence BP, so we modified the 2 diets by replacing fat with oat bran (10% w/w). Accordingly, we examined 4 groups of 5 rats consuming different diets: high sucrose, high sucrose + oat bran, low sucrose, and low sucrose + oat bran. Not unexpectedly, SHR consuming the diet high in sucrose had a significantly higher BP after 2 weeks than those consuming the diet low in sucrose. The significant difference in BP continued over the next 3 weeks. At the end of 6 week duration of study, we found the following BP: SHR ingesting the high sucrose diet, 217 mm Hg +/- 5 (SEM) vs SHR consuming the low sucrose diet, 187 mm Hg +/- 4 (SEM) p less than .0001]. SHR eating the low sucrose diet and consuming supplemental bran showed no significant change in BP after 6 weeks compared to SHR eating the basic diet alone, 188 mm Hg +/- 6 (SEM); however, 5 SHR consuming the high sucrose diet with added oat bran showed a significantly lower BP 200 mm Hg +/- 2 (SEM) than SHR ingesting the basic high sucrose diet devoid of oat bran [p less than .01]. We conclude that addition of oat bran to the diet can ameliorate sucrose-induced BP elevations in SHR.

Analysis of Variance↗

[The rare phenomenon of intraosseous gas collections (the so-called pneumatoceles].

We present two unusual cases of gas-filled cavities, the first in a 5th lumbar vertebra, the second in the subcortical area of the iliac bone close to the iliosacral joint. These accumulations of gas are evidently connected to vacuum phenomena in anatomically adjacent joints. They are characterised as pneumatoceles. Different mechanisms of these rare intraosseous gas accumulations are discussed.

Adult↗