B Hyle Park

Publications and source records attributed to B Hyle Park.

12 recordsLinked to original sources

Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography.

We present a generalized analysis of fiber-based polarization-sensitive optical coherence tomography with an emphasis on determination of sample optic axis orientation. The polarization properties of a fiber-based system can cause an overall rotation in a Poincaré sphere representation such that the plane of possible measured sample optic axes for linear birefringence and diattenuation no longer lies in the QU-plane. The optic axis orientation can be recovered as an angle on this rotated plane, subject to an offset and overall indeterminacy in sign such that only the magnitude, but not the direction, of a change in orientation can be determined. We discuss the accuracy of optic axis determination due to a fundamental limit on the accuracy with which a polarization state can be determined as a function of signal-to-noise ratio.

Algorithms↗

Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging.

OBJECTIVE: To introduce a new ophthalmic optical coherence tomography technology that allows unprecedented simultaneous ultra-high speed and ultra-high resolution. METHODS: Using a superluminescent diode source, a clinically viable ultra-high speed, ultra-high resolution spectral domain optical coherence tomography system was developed. RESULTS: In vivo images of the retina, the optic nerve head, and retinal blood flow were obtained at an ultra-high speed of 34.1 microseconds (ms) per A-scan, which is 73 times faster than commercially available optical coherence tomography instruments. Single images (B-scans) consisting of 1000 A-scans were acquired in 34.1 ms, allowing video rate imaging at 29 frames per second with an axial resolution of 6 mum. Using a different source in a slightly slower configuration, single images consisting of 500 A-scans were acquired in 34 ms, allowing imaging at 29 frames per second at an axial resolution of 3.5 microm, which is 3 times better than commercially available optical coherence tomography instruments. The amount of energy directed into the eye in both cases, 600 microW, is less than that of the Stratus OCT3 and is safe for intrabeam viewing for up to 8 hours at the same retinal location. CONCLUSION: Spectral domain optical coherence tomography technology enables ophthalmic imaging with unprecedented simultaneous ultra-high speed and ultra-high resolution.

Adult↗

Comment on "Optical-fiber-based Mueller optical coherence tomography".

We comment on the recent Letter by Jiao et al. [Opt. Lett. 28, 1206 (2003)] in which a polarization-sensitive optical coherence tomography system was presented. Interrogating a sample with two orthogonal incident polarization states cannot always recover birefringence correctly. A previously presented fiber-based polarization-sensitive system was inaccurately characterized, and its method of eliminating the polarization distortion caused by single-mode optical fiber was presented earlier by Saxer et al. [Opt. Lett. 25, 1355 (2000)].

Algorithms↗

Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components.

We present an analysis for polarization-sensitive optical coherence tomography that facilitates the unrestricted use of fiber and fiber-optic components throughout an interferometer and yields sample birefringence, diattenuation, and relative optic axis orientation. We use a novel Jones matrix approach that compares the polarization states of light reflected from the sample surface with those reflected from within a biological sample for pairs of depth scans. The incident polarization alternated between two states that are perpendicular in a Poincaré sphere representation to ensure proper detection of tissue birefringence regardless of optical fiber contributions. The method was validated by comparing the calculated diattenuation of a polarizing sheet, chicken tendon, and muscle with that obtained by independent measurement. The relative importance of diattenuation versus birefringence to angular displacement of Stokes vectors on a Poincaré sphere was quantified.

Algorithms↗

In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography.

An ultrahigh-speed spectral domain optical coherence tomography (SD-OCT) system is presented that achieves acquisition rates of 29,300 depth profiles/s. The sensitivity of SD-OCT and time domain OCT (TD-OCT) are experimentally compared, demonstrating a 21.7-dB improvement of SD-OCT over TD-OCT. In vivo images of the human retina are presented, demonstrating the ability to acquire high-quality structural images with an axial resolution of 6 microm at ultrahigh speed and with an ocular exposure level of less than 600 microW.

Humans↗

Collagen denaturation can be quantified in burned human skin using polarization-sensitive optical coherence tomography.

Quantifiable prognostic indicators are of considerable practical value following thermal injury. Collagen is a major component of the skin, and is known to undergo denaturation at the elevated temperatures associated with burns. The purpose of this study was to determine whether a recently developed, non-invasive imaging technique could detect and quantify collagen denaturation in burned human skin. Polarization-sensitive optical coherence tomography (PS-OCT) imaging was used to quantify collagen birefringence in normal human skin, and in skin excised from burn patients. Images were acquired and displayed in 1s, and demonstrated qualitative differences between normal and partial-thickness burned human skin. Birefringence loss due to thermal denaturation of collagen was quantified, with mean phase retardation rates for samples of 26 normal and 26 burned skin sites determined to be 0.401 +/- 0.020 and 0.249 +/- 0.017 degrees /microm, respectively (mean +/- S.E.M.), with this difference in sample means shown to be statistically significant (P < 0.000001). Analysis of the accuracy of the technique indicated that PS-OCT measurements may be made with resolution sufficient to distinguish between burns of varying severity. In conclusion, PS-OCT is capable of imaging and quantifying collagen denaturation in burned human skin, providing a new parameter against which post-injury outcome may be compared.

Adolescent↗

Advances in optical coherence tomography imaging for dermatology.

Optical coherence tomography (OCT) is a non-invasive imaging technique, which has previously demonstrated potential for use in dermatology. The purpose of this study is to demonstrate how improvements in image quality, speed, and functionality enable qualitative and quantitative information to be obtained from in vivo human skin. We developed a portable fiber-optic based OCT imaging device that requires only 1 second to simultaneously provide high-resolution images of skin structure, collagen birefringence, and blood flow. Images of normal human skin were acquired in vivo, and features compared with clinical and histologic observations. The layered structure and appendages of skin were apparent in conventional OCT images, and correlated well with corresponding histology. Polarization-sensitive OCT images simultaneously revealed birefringent regions within the dermis corresponding to the location of collagen fibers, as confirmed with polarized light microscopy. Properties of collagen-rich tissues including tendon and scar tissues were quantified. Location of blood flow was also displayed alongside structural and polarization-sensitive images. Significant improvements in OCT technology have been made since its early application in dermatology. In particular, combining the previously described structural and Doppler imaging functions with polarization-sensitive imaging increases the utility of the technique for rapid, non-invasive investigations in the skin.

Cicatrix↗

Thickness and birefringence of healthy retinal nerve fiber layer tissue measured with polarization-sensitive optical coherence tomography.

PURPOSE: Thinning of the retinal nerve fiber layer and changes in retinal nerve fiber layer (RNFL) birefringence may both precede clinically detectable glaucomatous vision loss. Early detection of RNFL changes may enable treatment to prevent permanent loss of vision. Polarization-sensitive optical coherence tomography (PS-OCT) can provide objective information on RNFL thickness and birefringence. METHODS: PS-OCT scans around the optic nerve head (ONH) of two healthy young volunteers were made using 10 concentric circles of increasing radius. Both the mean RNFL thickness and mean retinal nerve fiber birefringence for each of 48 sectors on a circle were determined with data analysis. RESULTS: Both the RNFL thickness and birefringence varied as a function of sector around the ONH. The RNFL became thinner with increasing distance from the ONH. In contrast, the birefringence did not vary significantly as a function of radius. CONCLUSIONS: Birefringence of healthy RNFL is constant as a function of scan radius but varies as a function of position around the ONH, with higher thickness values occurring superior and inferior to the ONH. Measured double-pass phase retardation per unit depth around the ONH ranged between 0.10 and 0.35 deg/microm, equivalent to birefringences of 1.2 x 10(-4) and 4.1 x 10(-4) respectively, measured at a wavelength of 840 nm. Consequently, when a spatially constant birefringence around the ONH is assumed, the conversion of scanning laser polarimetry (SLP) phase-retardation measurements to RNFL thickness may yield incorrect values. The data do not invalidate the clinical value of a phase-retardation measurement, but affect the conversion of phase retardation to RNFL thickness.

Adult↗

In vivo birefringence and thickness measurements of the human retinal nerve fiber layer using polarization-sensitive optical coherence tomography.

Glaucoma causes damage of the nerve fiber layer, which may cause loss of retinal birefringence. Therefore, PS-OCT is a potentially useful technique for the early detection of glaucoma. We built a fiber-based PS-OCT setup that produces real-time images of the human retina in vivo, coregistered with retinal video images of the location of PS-OCT scans. Preliminary measurements of a healthy volunteer show that the double-pass phase retardation per unit of depth of the RNFL is not constant and varies with location, with values between 0.18 and 0.37 deg/microm. A trend in the preliminary measurements shows that the nerve fiber layer located inferior and superior to the optic nerve head is more birefringent than the thinner layer of nerve fiber tissue in the temporal and nasal regions.

Adult↗

Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma.

Skin cancer is the most common human malignancy, with basal cell carcinoma (BCC) the most frequent type. Aggressive forms of BCC are associated with extensive dermal invasion and destruction of collagen. Surgery is the most common treatment, but identification of tumor borders is a challenge. Polarization-sensitive optical coherence tomography (PS-OCT) is an optical method to examine collagen birefringence. To date, it has not been exploited for cancer management. As part of a pilot exploratory study to examine the use of OCT in skin cancer, we examined several tumors that pose a challenge to the surgeon due to their large size and histological subtype. In normal perilesional skin, OCT identifies epidermal and dermal structure; PS-OCT identified dermal birefringence. In BCC, tumors lost normal structure and gained the appearance of lobular impressions. PS-OCT identified an alteration of dermal birefringence. Examination of a border area revealed a gradual transition from more normal appearing image to frank tumor. These results indicate that PS-OCT can identify features that distinguish normal skin from tumor and may have the potential to guide surgeons in the treatment of aggressive skin cancer.

Aged↗

Birefringence measurements in human skin using polarization-sensitive optical coherence tomography.

Optical coherence tomography enables cross-sectional imaging of tissue structure to depths of around 1.5 mm, at high-resolution and in real time. Incorporation of polarization sensitivity (PS) provides an additional contrast mechanism which is complementary to images mapping backscattered intensity only. We present here polarization-sensitive optical coherence tomography (OCT) images of human skin in vivo, demonstrating the ability of the technique to visualize and quantify the birefringent properties of skin. Variation in normal skin birefringence according to anatomical location is demonstrated, and discussed in relation to collagen distribution at each location. From measurements on a sample of five human volunteers, mean double-pass phase retardation rates of 0.340+/-0.143, 0.250+/-0.076, and 0.592+/-0.142 deg/microm were obtained for the dorsal hand, temple, and lower back regions, respectively. We demonstrate how averaging the Stokes parameters of backscattered light over a range of axial and lateral dimensions results in a reduction of speckle-induced noise. Examples of PS-OCT images from skin sites following wound healing and repair are also presented and discussed.

Adult↗