PubMed Health⌕ Search

Biomedical subjects

B J Erickson

Publications and source records attributed to B J Erickson.

At least 19 recordsLinked to original sources

FLAIR histogram segmentation for measurement of leukoaraiosis volume.

The purposes of this study were to develop a method to measure brain and white matter hyperintensity (leukoaraiosis) volume that is based on the segmentation of the intensity histogram of fluid-attenuated inversion recovery (FLAIR) images and to assess the accuracy and reproducibility of the method. Whole-head synthetic image phantoms with manually introduced leukoaraiosis lesions of varying severity were constructed. These synthetic image phantom sets incorporated image contrast and anatomic features that mimicked leukoaraiosis found in real life. One set of synthetic image phantoms was used to develop the segmentation algorithm (FLAIR-histoseg). A second set was used to measure its accuracy. Test retest reproducibility was assessed in 10 elderly volunteers who were imaged twice. The mean absolute error of the FLAIR-histoseg method was 6.6% for measurement of leukoaraiosis volume and 1.4% for brain volume. The mean test retest coefficient of variation was 1.4% for leukoaraiosis volume and 0.3% for brain volume. We conclude that the FLAIR-histoseg method is an accurate and reproducible method for measuring leukoaraiosis and whole-brain volume in elderly subjects.

Aged↗

Requirements for an enterprise digital image archive.

This report describes several image archival problems facing the authors' department and the results of their attempt to define the requirements for an enterprise digital image archive. The problems identified include the costs of supporting multiple distinct archives, the increased complexity of supporting multiple archive interfaces, the differences in data handling policies and resulting variations in data integrity, and variability in support for nonimage data. The authors also describe the data collected including image volumes and trends and imaging device trends. Finally, the resulting specification for an enterprise digital image archive, including storage and retrieval performance and interface requirements are presented.

Hospital Costs↗

Initial evaluation of a continuous speech recognition program for radiology.

The aims of this work were to measure the accuracy of one continuous speech recognition product and dependence on the speaker's gender and status as a native or nonnative English speaker, and evaluate the product's potential for routine use in transcribing radiology reports. IBM MedSpeak/Radiology software, version 1.1 was evaluated by 6 speakers. Two were nonnative English speakers, and 3 were men. Each speaker dictated a set of 12 reports. The reports included neurologic and body imaging examinations performed with 6 different modalities. The dictated and original report texts were compared, and error rates for overall, significant, and subtle significant errors were computed. Error rate dependence on modality, native English speaker status, and gender were evaluated by performing ttests. The overall error rate was 10.3 +/- 3.3%. No difference in accuracy between men and women was found; however, significant differences were seen for overall and significant errors when comparing native and nonnative English speakers (P = .009 and P = .008, respectively). The speech recognition software is approximately 90% accurate, and while practical implementation issues (rather than accuracy) currently limit routine use of this product throughout a radiology practice, application in niche areas such as the emergency room currently is being pursued. This methodology provides a convenient way to compare the initial accuracy of different speech recognition products, and changes in accuracy over time, in a detailed and sensitive manner.

Female↗

Induction of leptin expression in orbital preadipocyte fibroblasts.

Graves' ophthalmopathy (GO) is an autoimmune disease characterized by an increase in the volume of the orbital fatty/connective tissues and extraocular muscles. This volume change is due to expansion of the adipose tissues and to accumulation of glycosaminoglycans and edema within the connective tissues of the orbit. We have shown previously that a subpopulation of confluent human orbital preadipocyte fibroblasts can be induced in vitro to differentiate into cells with morphological features of adipocytes and that these cultures express functional thyrotropin receptor (TSHR). In order to identify and study these cells further, we examined the expression of leptin protein and TSHR and leptin mRNA in these cultures. Using immunocytochemistry with objective measurement of immunofluorescent staining intensity on digitized microscopic images, we determined leptin protein expression to be 6 to 37 times greater in differentiated cultures than in control cultures. In addition, we showed that the expression of both genes is enhanced in differentiated cultures. We suggest that an unknown humoral stimulus, present in Graves' disease, might act to induce the differentiation of normal orbital fibroblasts into TSHR-bearing adipocytes. This process would be expected to result in expansion of the orbital adipose tissues and increased TSHR expression within the orbit.

Adipocytes↗

Comparison of glucose levels in dermal interstitial fluid and finger capillary blood.

Alternative methods for self-monitoring of blood glucose have been pursued by many researchers, largely in response to evidence gathered in several long-term studies of patients with diabetes mellitus. These studies suggest that long-term complications of the disease may be mitigated if the disease is intensively managed, a component of which is increased monitoring. Many of the alternative methods utilize interstitial fluid (ISF) as the diagnostic fluid, rather than finger blood. A time lag in the distribution of glucose from blood to the interstitium has been observed by many, with estimates of lag time varying from none to 45 min. Dermal ISF was sampled from diabetic subjects in two tests and compared to finger blood glucose. In the first test, data were collected over time in a manner that allowed a cross-correlation analysis to predict an average lag time. Information from this test was then used as input to a data collection format for a method comparison test of 691 patients with diabetes in which ISF data were collected immediately after the finger blood reference and 15 min after the reference. An average lag time of about 25 min was determined from the cross-correlation analysis, with the correlation error reduced by three-fourths within a 15-min lag time. In the method comparison test, the correlation coefficient between finger blood glucose and ISF glucose improved from 0.923 to 0.951, and the percentage of data in the A zone of the Clarke Error Grid rose from 80.2% to 90.6% for the ISF glucose data collected at no lag and 15-min lag, respectively. Dermal ISF glucose measurement might be a reasonable alternative to blood glucose measurement for patients routinely monitoring ambient glycemia, although more testing in the sensitive hypoglycemic range is needed to clarify what might happen in cases of rapidly changing glucose.

Blood Glucose↗

IV immunoglobulin does not reverse established weakness in MS.

BACKGROUND: Immunoglobulin (Ig) administration induces remyelination in the Theiler's virus model of MS. METHODS: A randomized, double-blinded, placebo-controlled trial of IV immunoglobulin (IVIg) was performed in patients with MS who had persistent muscle weakness that had been stable for between 4 and 18 months to determine whether this would improve muscle strength (primary outcome: isometric muscle strength). Patients received either IVIg (0.4 g/kg) or placebo daily for 5 days, then single infusions every 2 weeks for 3 months (total, 11 infusions). Muscle groups identified by clinical measures to have unchanging significant weakness were the major targets for therapeutic response (targeted neurologic deficit [TND]). RESULTS: IVIg was well tolerated. An interim analysis after 67 patients were enrolled indicated no difference in the degree of change in strength between treatment groups in either the TND or non-TND muscle groups at 6 months, and the trial was terminated. There was no apparent benefit in relapse behavior or impairment measures during the 6-month observation period. Nor was there apparent benefit in either patients who remained clinically stable or in those with evidence of disease activity. Patients with active MS during the trial worsened in both TND and non-TND muscle groups. This worsening was seen regardless of whether the clinical manifestations of disease activity involved the TND muscle groups. CONCLUSIONS: IVIg does not reverse established weakness in MS. Measurements of isometric muscle strength were reliable (reproducible) indices of strength and may be sensitive, objective methods to document functional changes in impairment in future MS trials.

Adult↗

Performance and function of a desktop viewer at Mayo Clinic Scottsdale.

A clinical viewing system was integrated with the Mayo Clinic Scottsdale picture archiving and communication system (PACS) for providing images and the report as part of the electronic medical record (EMR). Key attributes of the viewer include a single user log-on, an integrated patient centric EMR image access for all ordered examinations, prefetching of the most recent prior examination of the same modality, and the ability to provide comparison of current and past exams at the same time on the display. Other functions included preset windows, measurement tools, and multiformat display. Images for the prior 12 months are stored on the clinical server and are viewable in less than a second. Images available on the desktop include all computed radiography (CR), chest, magnetic resonance images (MRI), computed tomography (CT), ultrasound (U/S), nuclear, angiographic, gastrointestinal (GI) digital spots, and portable C-arm digital spots. Ad hoc queries of examinations from PACS are possible for those patients whose image may not be on the clinical server, but whose images reside on the PACS archive (10TB). Clinician satisfaction was reported to be high, especially for those staff heavily dependent on timely access to images, as well as those having heavy film usage. The desktop viewer is used for resident access to images. It is also useful for teaching conferences with large-screen projection without film. We report on the measurements of functionality, reliability, and speed of image display with this application.

Arizona↗

An evaluation of JPEG and JPEG 2000 irreversible compression algorithms applied to neurologic computed tomography and magnetic resonance images. Joint Photographic Experts Group.

We performed visual comparison of 200 head magnetic resonance (MR) and 200 head computed tomography (CT) images compressed at two levels using standard Joint Photographic Experts Group (JPEG) irreversible compression and a preliminary version of the JPEG 2000 irreversible algorithm. Blinded evaluations by neuroradiologists compared original versus either JPEG or JPEG 2000. We found that this version of JPEG 2000 did not perform as well as the current JPEG for head CTs, but for MR images, JPEG 2000 performed as well or better. Around 7:1 compression ratio seemed to be a conservative point where there was no perceptible difference.

Algorithms↗

Ultrasound grayscale image compression with JPEG and wavelet techniques.

The purpose of the study was to evaluate the effects of lossy compression on grayscale ultrasound images to determine how much compression can be applied while still maintaining images that are acceptable for diagnostic purposes. The study considered how the acquisition technique (video frame-grabber versus directly acquired in digital form) influences how much compression can be applied. For directly acquired digital images, the study considered how text (that is burned into the image) affects the compressibility of the image. The lossy compression techniques that were considered include JPEG and a Wavelet algorithm using set partitioning in hierarchical trees (SPIHT).

Image Processing, Computer-Assisted↗

The psychiatric emergency service: where we've been and where we're going.

The Psychiatric Emergency Service (PES) has evolved into a separate service with its own space and staff specialized for the handling of psychiatric emergencies. A study of trends in our PES reveals increased need for children's services, issues with managed care and an expansion in the use of the PES as a filter for the mental health system in dealing with substance abuse. Education and research have been added to the missions of the PES and there is strong potential for future development in this area. PESs of the future may be very different, with advances in communication, safety, computerized records and databases. New dilemmas in balancing the patient's right to confidentiality and autonomy against the potential of these advances are bound to occur.

Attention Deficit and Disruptive Behavior Disorder↗

Electronic imaging and clinical implementation: work group approach at Mayo Clinic, Rochester.

Electronic imaging clinical implementation strategies and principles need to be developed as we move toward replacement of film-based radiology practices. During an 8-month period (1998 to 1999), an Electronic Imaging Clinical Implementation Work Group (EICIWG) was formed from sections of our department: Informatics Lab, Finance Committee, Management Section, Regional Practice Group, as well as several organ and image modality sections of the Department of Diagnostic Radiology. This group was formed to study and implement policies and strategies regarding implementation of electronic imaging into our practice. The following clinical practice issues were identified as key focus areas: (1) optimal electronic worklist organization; (2) how and when to link images with reports; (3) how to redistribute technical and professional relative value units (RVU); (4) how to facilitate future practice changes within our department regarding physical location and work redistribution; and (5) how to integrate off-campus imaging into on-campus workflow. The EICIWG divided their efforts into two phases. Phase I consisted of Fact finding and review of current practice patterns and current economic models, as well as radiology consulting needs. Phase II involved the development of recommendations, policies, and strategies for reengineering the radiology department to maintain current practice goals and use electronic imaging to improve practice patterns. The EICIWG concluded that electronic images should only be released with a formal report, except in emergent situations. Electronic worklists should support and maintain the physical presence of radiologists in critical areas and direct imaging to targeted subspecialists when possible. Case tools should be developed and used in radiology and hospital information systems (RIS/HIS) to monitor a number of parameters, including professional and technical RVU data. As communication standards improve, proper staffing models must be developed to facilitate electronic on-campus and off-campus consultation.

Diagnostic Imaging↗

Impact of electronic imaging on clinician behavior in the urgent care setting.

Although it is intuitively valuable that more expedient delivery of radiographic images and reports to clinicians would improve patient care, it is important to document these outcomes to validate further advances in these areas. We evaluated the care of 215 patients seen at a walk-in clinic to determine what benefit digital imaging is to the patient. Cohorts consisted of all patients for whom specified radiology examinations were ordered during a 7-day period. The first cohort was recruited when analog films were used. The second cohort received examinations performed with computed radiography (CR) acquisition and computer display, which had been in use for 2 years. Patients were categorized as to the type of study they received, as well as whether a staff radiologist was immediately available to read the study. Clinical behavior was characterized by outcome measures of time to final diagnosis, time to final treatment, and need for follow-up. Our analysis demonstrated a reduction in time to final diagnosis that was better appreciated during the times when a staff radiologist was not immediately available. It also suggested that greater time reductions were seen for patients who received extremity examinations than those who received chest, sinus, or rib films. These data suggest that digital imaging is a useful tool to improve clinical outcome of patients seen in the acute care setting.

Adult↗

Electronic imaging impact on image and report turnaround times.

We prospectively compared image and report delivery times in our Urgent Care Center (UCC) during a film-based practice (1995) and after complete implementation of an electronic imaging practice in 1997. Before switching to a totally electronic and filmless practice, multiple time periods were consistently measured during a 1-week period in May 1995 and then again in a similar week in May 1997 after implementation of electronic imaging. All practice patterns were the same except for a film-based practice in 1995 versus a filmless practice in 1997. The following times were measured: (1) waiting room time, (2) technologist's time of examination, (3) time to quality control, (4) radiology interpretation times, (5) radiology image and report delivery time, (6) total radiology turn-around time, (7) time to room the patient back in the UCC, and (8) time until the ordering physician views the film. Waiting room time was longer in 1997 (average time, 26:47) versus 1995 (average time, 15:54). The technologist's examination completion time was approximately the same (1995 average time, 06:12; 1997 average time, 05:41). There was also a slight increase in the time of the technologist's electronic verification or quality control in 1997 (average time, 7:17) versus the film-based practice in 1995 (average time, 2:35). However, radiology interpretation times dramatically improved (average time, 49:38 in 1995 versus average time 13:50 in 1997). There was also a decrease in image delivery times to the clinicians in 1997 (median, 53 minutes) versus the film based practice of 1995 (1 hour and 40 minutes). Reports were available with the images immediately upon completion by the radiologist in 1997, compared with a median time of 27 minutes in 1995. Importantly, patients were roomed back into the UCC examination rooms faster after the radiologic procedure in 1997 (average time, 13:36) than they were in 1995 (29:38). Finally, the ordering physicians viewed the diagnostic images and reports in dramatically less time in 1997 (median, 26 minutes) versus 1995 (median, 1 hour and 5 minutes). In conclusion, a filmless electronic imaging practice within our UCC greatly improved radiology image and report delivery times, as well as improved clinical efficiency.

Adult↗

Evaluating a picture archiving and communications system workstation.

An efficient environment for picture archiving and communications systems (PACS) in the radiology department and throughout a medical practice requires good hardware, good software, and integration of the information sources that exist in a radiology department and institution. This tutorial will describe some of the considerations in evaluating a PACS workstation, with a view to the hardware requirements, user interface designs, and integration with the information systems.

Computer Systems↗

Chemotherapy for advanced CNS ependymoma.

BACKGROUND: The role of chemotherapy in recurrent ependymoma is poorly defined. This study was performed to help clarify the benefits of chemotherapy in this setting. PATIENTS AND METHODS: We retrospectively reviewed the charts of patients with advanced ependymoma of the CNS who received chemotherapy in our institution between 1974 and 1993, inclusive. Sixteen consecutive patients were treated with regimens containing either nitrosourea, platinum, or other combinations exclusive of nitrosourea or platinum. No patient received nitrosourea and platinum concurrently. Two methods were used to define response. The first was a direct comparison of radiographic images before and after chemotherapy more than one month apart. A second broader definition of response that employed four other criteria in addition to imaging studies (symptoms, signs, performance status, and neurologic functional status) was also used. RESULTS: Results were as follows (response rate by imaging studies followed by response rate by scoring in parenthesis): Platinum-based chemotherapy resulted in a 67% (83%) response rate with 33% (0%) remaining stable. Nitrosourea-based regimens resulted in a 25% (60%) response rate with 50% (10%) remaining stable. When combinations other than platinum or nitrosourea were used, 11% (22%) responded and 56% (44%) remained stable. Relative differences in response rates between chemotherapy regimens persisted when the data were analyzed by grade. Median time to progression was 6, 10, and 3 months, respectively. CONCLUSION: Platinum-based chemotherapy regimens appear to result in higher response rates with lower rates of progression than nitrosourea-based regimens. Other regimens that do not include cisplatinum or nitrosourea appear to be even less effective.

Adolescent↗