PubMed Health⌕ Search

Biomedical subjects

B J Friedman

Publications and source records attributed to B J Friedman.

At least 19 recordsLinked to original sources

Effects of the Clarion Electrode Positioning System on auditory thresholds and comfortable loudness levels in pediatric patients with cochlear implants.

OBJECTIVE: To evaluate the effects of using the Electrode Positioning System on psychophysical auditory thresholds, most comfortable loudness levels, and electric auditory brainstem response (EABR) thresholds in children with the Clarion version 1.2 cochlear implant. DESIGN: Retrospective analysis. SETTING: Academic tertiary care center. PATIENTS AND METHODS: Clinical records of a series of 25 children who received the Clarion version 1.2 cochlear implant at the University of Minnesota, Minneapolis, between January 1997 and August 1999 were examined. Measures evaluated were psychophysical thresholds (T-levels) and most comfortable loudness levels (M-levels) obtained at the 3-month posthookup audiologic evaluation and EABR thresholds obtained during implant surgery. Relevant threshold measures were available for 24 patients, 11 of whom had received the Clarion spiral electrode and electrode positioner (EP group) and 13 of whom had received the spiral electrode without positioner (non-EP group). The 3 measures (T-levels, M-levels, and EABR thresholds) were compared across groups. In addition, EABR thresholds were compared with T-levels and M-levels within groups. RESULTS: Mean T-levels and M-levels were significantly lower for the EP group than for the non-EP group, and interpatient variability for these measures was considerably smaller in the EP group. Electric auditory brainstem response thresholds were not significantly different for EP vs non-EP patients; however, EABR data were available for only a few non-EP patients. CONCLUSIONS: Use of the electrode positioner results in lower T-levels and M-levels in children with the Clarion version 1.2 cochlear implant, consistent with results of previous studies in adults, and reduces across-patient variability for these measures. It is unclear from the present data whether use of the electrode positioner systematically reduces intraoperative EABR thresholds.

Auditory Threshold↗

Acute hemodynamic and coronary circulatory effects of experimental autoimmune myocarditis.

Myocarditis and progression to cardiomyopathy is associated with focal spasm and reperfusion of the coronary microcirculation. Experimental autoimmune myocarditis (EAM), induced with cardiomyosin peptide-specific T cells in Lewis rats, was hypothesized to cause acute hemodynamic and coronary vasculature changes. Fifteen experimental animals (5 each at 1, 2, and 3 weeks after T-cell injection) and eight controls were studied using the constant pressure variant of the isolated heart. Coronary resistant decreased while coronary flow increased (P < 0.05) in EAM hearts after the first week. Rate-pressure product, +dP/dt and -dP/dt, decreased while the heart/body weight ratio increased (P < 0.05) compared with controls at 1 week but not at 2 or 3 weeks. Mean local myocardial PO2, which reflects local oxygen delivery and consumption, and MVO2 were not different for EAM hearts. However, compared with controls EAM myocardial PO2 varied more widely and was often beyond the usual range, suggesting the occurrence of localized hypoxic and hyperoxic areas. In summary, after the first week there was a significant decrease in coronary resistance in the EAM animals, which required higher flow to maintain a similar perfusion pressure. These changes in coronary resistance and flow along with the heterogeneity and extremes of local myocardial PO2 levels without a significant change in MVO2 may be explained by postulating development of low-resistance, high-flow hyperoxic areas which steal flow, thus causing hypoxia in other areas.

Acute Disease↗

Myocardial oxygen tension in isolated erythrocyte-perfused rat hearts and comparison with crystalloid media.

The isolated heart, typically perfused with crystalloid media equilibrated with >/=95% O2 to ensure adequate myocardial oxygen tension, is commonly used to study cardiac function. When hemoglobin is available for oxygen transport, equilibration with 21% O2 is considered adequate to meet metabolic demands. This study presents the measurement of myocardial pO2 in isolated hearts perfused with an erythrocyte suspension. Baseline myocardial pO2 in erythrocyte-perfused hearts was 16.4+/-3.5 mmHg (mean+/-s.e.). When compared to previous measurements of myocardial pO2 in isolated hearts perfused with crystalloid media, the use of erythrocyte suspensions resulted in a 10-fold lower level of myocardial pO2, while avoiding very low and high values. The standard use of 95% oxygen with crystalloid results in myocardial levels of oxygen far above those usually found in the presence of hemoglobin and room air.

Animals↗

Myocardial oxygen tension and capillary density in the isolated perfused rat heart during pharmacological intervention.

Oxygen is essential for normal cardiac function and plays an important role in cardiac regulation. Electron paramagnetic resonance (EPR) oximetry appears to have some significant advantages for measuring oxygen tension (pO2) in the beating heart. This study presents the serial measurement of myocardial pO2 by EPR oximetry in the isolated crystalloid perfused heart during treatment with different cardioactive drugs: dobutamine, metoprolol, verapamil, vasopressin, and N omega-Nitro-L-Arginine Methyl Ester (L-NAME). Baseline myocardial pO2 was 176 +/- 14 mmHg (mean +/- S.E.). Myocardial capillary density in the intact contracting heart was calculated to be 2300 +/- 100 mm-2, using local myocardial pO2 and a cylindrical model for oxygen diffusion in tissue. Each drug had characteristic effects on myocardial pO2, myocardial oxygen consumption (MVO2), and capillary density. Metoprolol and verapamil increased myocardial pO2 by 51% and 18%, respectively, dobutamine decreased myocardial pO2 by 84% while vasopressin and L-NAME had no significant effect on myocardial pO2. Metoprolol and verpamil decreased MVO2 by 9% and 56%, respectively, while dobutamine increased MVO2 by 59%. A quantitative comparison of effects on the capillary bed based on changes in myocardial pO2 and MVO2 was made. Metoprolol and verapamil had opposite effects on the capillary bed. Verapamil decreased myocardial capillary density by 39%, while capillary density increased by 10% (n.s.) with metoprolol. Data following perfusion without drug is also presented. We conclude that: 1) The application of EPR oximetry with LiPc provides dynamic evaluation of local myocardial pO2 in the contracting heart. 2) Using a cylindrical model of oxygen delivery and diffusion in tissue, these data may be used to describe the changes of capillary density during pharmacological interventions.

Adrenergic beta-Agonists↗

Effect of repetitive ischemia on myocardial oxygen tension in isolated perfused and hypoperfused rat hearts.

The objective of this study was to determine the effects of repetitive ischemia on myocardial oxygen tension (pO2), consumption, and delivery in crystalloid normoperfused (perfusion pressure>70 mmHg) and hypoperfused (perfusion pressure approximately 50 mmHg) constant flow isolated rat hearts. EPR oximetry with lithium phthalocyanine was used to measure myocardial pO2. Baseline myocardial pO2 (means +/- SE) was 185 +/- 13 mmHg (normoperfused) and 162 +/- 14 mmHg (hypoperfused). Myocardial pO2 fell to < 1 mmHg during no-flow ischemia. After recovery from repetitive ischemia, myocardial pO2 and coronary resistance increased significantly in all hearts; oxygen consumption and left ventricle work decreased in normoperfused hearts, although not significantly compared with controls, and did not change significantly in hypoperfused hearts. Increased myocardial pO2 in the normoperfused group may be due to decreased oxygen consumption and/or increased local delivery, while increased myocardial pO2 in the hypoperfused hearts is due to increased local oxygen delivery.

Animals↗

Myocardial oxygen tension and relative capillary density in isolated perfused rat hearts.

Oxygen plays an important role in cardiac function. Many methods have been applied to measure tissue oxygen tension (PO2). Electron paramagnetic resonance (EPR) oximetry appears to have some significant advantages for use in the beating heart. This study presents the serial measurement of myocardial PO2 by EPR oximetry in the isolated crystalloid perfused heart during changes of influent PO2, coronary flow rate, oxygen consumption and end-diastolic pressure. Baseline myocardial PO2 was 198 +/- 12 mmHg (mean +/- S.E.). Myocardial PO2 increased as expected with increased delivery (concentration or flow) or decreased consumption. With increasing flow rate, myocardial PO2 increased in a sigmoid fashion. A critical flow or pressure was reached when myocardial PO2 rapidly increased to a higher level. Increased left ventricular end-diastolic pressure caused local vascular compression and resulted in a decrease of myocardial PO2. Myocardial capillary density in the intact contracting heart was calculated to be 2300 +/- 110/mm2, using local myocardial PO2 and a cylindrical model for oxygen diffusion in tissue. Relative capillary density did not change with mild to moderate hypoxia, increased with increasing flow and increasing oxygen consumption and decreased with elevated diastolic pressure. We conclude that the application of EPR oximetry with LiPc to the isolated heart provides accurate and dynamic evaluation of local myocardial PO2 in the contracting heart. Using various models of oxygen delivery and diffusion in tissue, these data may also be used to serially follow capillary density.

Animals↗

Double-lumen catheter assessment of aortic stenosis: comparison with separate catheter technique.

Hemodynamic assessment of aortic stenosis in the catheterization laboratory accurate determination of the transvalvular gradient. A commercially available double-lumen pigtail catheter can be used to obtain this gradient via a single arterial puncture. The catheter has several advantages over other methods used to measure the gradient in aortic stenosis, but it has not been critically evaluated. In order to assess the performance of this catheter compared to the traditional standard of separate catheters above and across the aortic valve, we studied 10 patients with aortic stenosis using both catheter systems. Aortic valve areas ranged from 0.34 cm2 to 1.1 cm2. Linear regression analysis confirmed excellent correlation between the two methods in measurement of the mean transvalvular gradient (r = 0.98) and calculation of the aortic valve area (r = 0.99) using the Gorlin formula. We conclude that the double-lumen pigtail catheter provides accurate data in the hemodynamic evaluation of aortic stenosis.

Aged↗

Hospital smoking policies: who enforces them?

As opprobrium is increasingly given to the act of smoking, many institutions--hospitals especially--are seeking to curtail the amount of smoking that occurs within their buildings through various policies. This, however, raises two necessary questions: What does policy enforcement mean? And who shall enforce the rules? The article below discusses the results of a survey of North Carolina hospitals that asked these questions and more.

Hospital Administration↗

Dietary treatment of hypercholesterolemia.

Diet is the first line of treatment for hypercholesterolemia. Patients should be encouraged to make simple and stepwise changes in their diets to lower elevated cholesterol levels. General dietary guidelines from the American Heart Association (AHA) Step-One Diet include limiting the amount of total fat to less than 30% of total calories, decreasing cholesterol intake to less than 300 mg/day, and adjusting caloric intake to levels required to attain or maintain ideal body weight. Diets must be individualized to meet therapeutic needs within the limits of the patient's abilities, knowledge, and motivation.

Cholesterol, Dietary↗

Use of a heart sound simulator in teaching cardiac auscultation.

The use of a heart sound simulator in teaching recognition of heart sounds was tested in 37 graduate students. Subjects were randomly divided into two groups; one group received both auditory and tactile cues and the other group received only auditory cues. Students were tested at three times: (1) before use of the simulator, (2) after a short teaching session using the simulator, and (3) 2 weeks later. Recognition of heart sounds increased significantly after the teaching session with the simulator, and this knowledge was retained. There was no difference in sound recognition between the two groups.

Adult↗

Effectiveness of teaching breast self examination during office visits.

In a randomized clinical trial a comparison was made of two BSE teaching interventions delivered by primary providers during office visits in a group nursing faculty practice. Patients who reported no regular BSE (n = 121) received either individualized teaching focused on reducing perceived barriers and reinforcing benefits of BSE, or routine teaching limited to usual instruction in BSE technique. Patients reporting frequent/monthly BSE during the past year were comparison subjects (n = 81). Self-reported data on BSE behavior were obtained in questionnaires administered before the interventions and via telephone interviews three months after the visit. Analysis using chi square showed that, contrary to expectation, individualized and routine teaching were equally effective: 61.4% of the individually taught and 63.5% of the routinely taught reported frequent or monthly practice at followup. Both groups were significantly more confident in technique and ability to detect change in the breast. The previously non-practicing women remained significantly less likely than comparison subjects to be performing BSE monthly at followup. The perceived benefit of BSE giving peace of mind predicted non-practicers most likely to change.

Adult↗