Comparison of ghosting effects for three commercial a-Si EPIDs.

Many studies have reported dosimetric characteristics of amorphous silicon electronic portal imaging devices (EPIDs). Some studies ascribed a non-linear signal to gain ghosting and image lag. Other reports, however, state the effect is negligible. This study compares the signal-to-monitor unit (MU) ratio for three different brands of EPID systems. The signal was measured for a wide range of monitor units (5-1000), dose-rates, and beam energies. All EPIDs exhibited a relative under-response for beams of few MUs; giving 4 to 10% lower signal-to-MU ratios relative to that of 1000 MUs. This under-response is consistent with ghosting effects due to charge trapping.

Calibration↗

Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.

The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic. Furthermore, we described how EPID dosimetry was used to solve a clinical problem. IMRT prostate plans were delivered to a homogeneous slab phantom. EPID transit images were acquired for each segment. A previously developed in-house back-projection algorithm was used to reconstruct the dose distribution in the phantom mid-plane (intersecting the isocenter). Segment dose images were summed to obtain an EPID mid-plane dose image for each field. Fields were compared using profiles and in two dimensions with the y evaluation (criteria: 3%/3 mm). To quantify results, the average gamma (gamma avg), maximum gamma (gamma max), and the percentage of points with gamma < 1(P gamma < 1) were calculated within the 20% isodose line of each field. For 10 patient plans, all fields were measured with EPID and film at gantry set to 0 degrees. The film was located in the phantom coronal mid-plane (10 cm depth), and compared with the back-projected EPID mid-plane absolute dose. EPID and film measurements agreed well for all 50 fields, with (gamma avg) =0.16, (gamma max)=1.00, and (P gamma < 1)= 100%. Based on these results, film measurements were discontinued for verification of prostate IMRT plans. For 20 patient plans, the dose distribution was re-calculated with the phantom CT scan and delivered to the phantom with the original gantry angles. The planned isocenter dose (plan(iso)) was verified with the EPID (EPID(iso)) and an ionization chamber (IC(iso)). The average ratio, (EPID(iso)/IC(iso)), was 1.00 (0.01 SD). Both measurements were systematically lower than planned, with (EPID(iso)/plan(iso)) and (IC(iso)/plan(iso))=0.99 (0.01 SD). EPID mid-plane dose images for each field were also compared with the corresponding plane derived from the three dimensional (3D) dose grid calculated with the phantom CT scan. Comparisons of 100 fields yielded (gamma avg)=0.39, gamma max=2.52, and (P gamma < 1)=98.7%. Seven plans revealed under-dosage in individual fields ranging from 5% to 16%, occurring at small regions of overlapping segments or along the junction of abutting segments (tongue-and-groove side). Test fields were designed to simulate errors and gave similar results. The agreement was improved after adjusting an incorrectly set tongue-and-groove width parameter in the treatment planning system (TPS), reducing (gamma max) from 2.19 to 0.80 for the test field. Mid-plane dose distributions determined with the EPID were consistent with film measurements in a slab phantom for all IMRT fields. Isocenter doses of the total plan measured with an EPID and an ionization chamber also agreed. The EPID can therefore replace these dosimetry devices for field-by-field and isocenter IMRT pre-treatment verification. Systematic errors were detected using EPID dosimetry, resulting in the adjustment of a TPS parameter and alteration of two clinical patient plans. One set of EPID measurements (i.e., one open and transit image acquired for each segment of the plan) is sufficient to check each IMRT plan field-by-field and at the isocenter, making it a useful, efficient, and accurate dosimetric tool.

Algorithms↗

Experimental verification of a portal dose prediction model.

Electronic portal imaging devices (EPIDs) can be used to measure a two-dimensional (2D) dose distribution behind a patient, thus allowing dosimetric treatment verification. For this purpose we experimentally assessed the accuracy of a 2D portal dose prediction model based on pencil beam scatter kernels. A straightforward derivation of these pencil beam scatter kernels for portal dose prediction models is presented based on phantom measurements. The model is able to predict the 2D portal dose image (PDI) behind a patient, based on a PDI without the patient in the beam in combination with the radiological thickness of the patient, which requires in addition a PDI with the patient in the beam. To assess the accuracy of portal dose and radiological thickness values obtained with our model, various types of homogeneous as well as inhomogeneous phantoms were irradiated with a 6 MV photon beam. With our model we are able to predict a PDI with an accuracy better than 2% (mean difference) if the radiological thickness of the object in the beam is symmetrically situated around the isocenter. For other situations deviations up to 3% are observed for a homogeneous phantom with a radiological thickness of 17 cm and a 9 cm shift of the midplane-to-detector distance. The model can extract the radiological thickness within 7 mm (maximum difference) of the actual radiological thickness if the object is symmetrically distributed around the isocenter plane. This difference in radiological thickness is related to a primary portal dose difference of 3%. It can be concluded that our model can be used as an easy and accurate tool for the 2D verification of patient treatments by comparing predicted and measured PDIs. The model is also able to extract the primary portal dose with a high accuracy, which can be used as the input for a 3D dose reconstruction method based on back-projection.

Algorithms↗

Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device.

The purpose of this study was to investigate the dose-response characteristics, including ghosting effects, of an amorphous silicon-based electronic portal imaging device (a-Si EPID) under clinical conditions. EPID measurements were performed using one prototype and two commercial a-Si detectors on two linear accelerators: one with 4 and 6 MV and the other with 8 and 18 MV x-ray beams. First, the EPID signal and ionization chamber measurements in a mini-phantom were compared to determine the amount of buildup required for EPID dosimetry. Subsequently, EPID signal characteristics were studied as a function of dose per pulse, pulse repetition frequency (PRF) and total dose, as well as the effects of ghosting. There was an over-response of the EPID signal compared to the ionization chamber of up to 18%, with no additional buildup layer over an air gap range of 10 to 60 cm. The addition of a 2.5 mm thick copper plate sufficiently reduced this over-response to within 1% at clinically relevant patient-detector air gaps (> 40 cm). The response of the EPIDs varied by up to 8% over a large range of dose per pulse values, PRF values and number of monitor units. The EPID response showed an under-response at shorter beam times due to ghosting effects, which depended on the number of exposure frames for a fixed frame acquisition rate. With an appropriate build-up layer and corrections for dose per pulse, PRF and ghosting, the variation in the a-Si EPID response can be reduced to well within +/- 1%.

Air↗

The stability of liquid-filled matrix ionization chamber electronic portal imaging devices for dosimetry purposes.

This study was performed to determine the stability of liquid-filled matrix ionization chamber (LiFi-type) electronic portal imaging devices (EPID) for dosimetric purposes. The short- and long-term stability of the response was investigated, as well as the importance of factors influencing the response (e.g., temperature fluctuations, radiation damage, and the performance of the electronic hardware). It was shown that testing the performance of the electronic hardware as well as the short-term stability of the imagers may reveal the cause of a poor long-term stability of the imager response. In addition, the short-term stability was measured to verify the validity of the fitted dose-response curve immediately after beam startup. The long-term stability of these imagers could be considerably improved by correcting for room temperature fluctuations and gradual changes in response due to radiation damage. As a result, the reproducibility was better than 1% (1 SD) over a period of two years. The results of this study were used to formulate recommendations for a quality control program for portal dosimetry. The effect of such a program was assessed by comparing the results of portal dosimetry and in vivo dosimetry using diodes during the treatment of 31 prostate patients. The improvement of the results for portal dosimetry was consistent with the deviations observed with the reproducibility tests in that particular period. After a correction for the variation in response of the imager, the average difference between the measured and prescribed dose during the treatment of prostate patients was -0.7%+/-1.5% (1 SD), and -0.6%+/-1.1% (1 SD) for EPID and diode in vivo dosimetry, respectively. It can be concluded that a high stability of the response can be achieved for this type of EPID by applying a rigorous quality control program.

Electronics, Medical↗

The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes.

This study was carried out to determine the stability of the response of amorphous silicon (a-Si)-flat panel imagers for dosimetry applications. Measurements of the imager's response under reference conditions were performed on a regular basis for four detectors of the same manufacturer. We found that the ambient temperature influenced the dark-field, while the gain of the imager signal was unaffected. Therefore, temperature fluctuations were corrected for by applying a "dynamic" darkfield correction. This correction method also removed the influence of a small, irreversible increase of the dark-field current, which was equal to 0.5% of the dynamic range of the imager per year and was probably caused by mild radiation damage to the a-Si array. By applying a dynamic dark-field correction, excellent stability of the response over the entire panel of all imagers of 0.5% (1 SD) was obtained over an observation period up to 23 months. However, two imagers had to be replaced after several months. For one imager, an image segment stopped functioning, while the image quality of the other imager degraded significantly. We conclude that the tested a-Si EPIDs have a very stable response and are therefore well suited for dosimetry. We recommend, however, applying quality assurance tests dedicated to both imaging and dosimetry.

Calibration↗

Three-dimensional dose reconstruction of breast cancer treatment using portal imaging.

In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the patient was used to correct for absorption of primary photons, but the presence of inhomogeneities was not taken into account. The accuracy of the algorithm was determined by irradiating two anthropomorphic breast phantoms with 6 MV photons. The dose values derived from portal images were compared with results from 3-D dose calculations, which, in turn, were verified with data obtained with an ionization chamber and film dosimetry. It was found that the application of contour information significantly improves the accuracy of 2-D dose reconstruction. If the total dose at the isocenter plane resulting from all treatment beams is reconstructed, the average deviation from the planned dose is 0.1%+/-1.7% (1 SD). If contour information is not available, the differences increase up to +/-20% for the individual beams. In that case, the dose can only be reconstructed with reasonable accuracy when (nearly) opposing beams are used. The average deviation of the 3-D reconstructed dose from the planned dose in the irradiated volume is 1.4%+/-5.4% (1 SD). If the irradiated volume is enclosed by planes less than 5 cm distant from the isocenter plane, then the average deviation is only 0.5%+/-3.4% (1 SD). It can be concluded that the proposed algorithm for a 3-D dose reconstruction allows a determination of the dose at the isocenter plane and the dose-volume histogram with an accuracy acceptable for an independent verification of the treatment.

Algorithms↗

Field size reduction enables iso-NTCP escalation of tumor control probability for irradiation of lung tumors.

PURPOSE: With the mean lung dose (MLD) as an estimator for the normal tissue complication probability (NTCP) of the lung, we assessed whether the probability of tumor control of lung tumors might be increased by dose escalation in combination with a reduction of field sizes, thus increasing target dose inhomogeneity while maintaining a constant MLD. METHODS AND MATERIALS: An 8-MV AP-PA irradiation of a lung tumor, located in a cylindrically symmetric lung-equivalent phantom, was modeled using numerical simulation. Movement of the clinical target volume (CTV) due to patient breathing and setup errors was simulated. The probability of tumor control, expressed as the equivalent uniform dose (EUD) of the CTV, was assessed as a function of field size, under the constraint of a constant MLD. The approach was tested for a treatment of a non-small cell lung cancer (NSCLC) patient using the beam directions of the clinically applied treatment plan. RESULTS: In the phantom simulation it was shown that by choosing field sizes that ensured a minimum dose of 95% in the CTV ("conventional" plan) taking into account setup errors and tumor motion, an EUD of the CTV of 43.8 Gy can be obtained for a prescribed dose of 44.2 Gy. By reducing the field size and thus shifting the 95% isodose surface inwards, the EUD increases to a maximum of 68.3 Gy with a minimum dose in the CTV of 55.2 Gy. This increase in EUD is caused by the fact that field size reduction enables escalation of the prescribed dose while maintaining a constant MLD. Further reduction of the field size results in decrease of the EUD because the minimum dose in the CTV becomes so low that it has a predominant effect on the EUD, despite further escalation of the prescribed dose. For the NSCLC patient, the EUD could be increased from an initial 62.2 Gy for the conventional plan, to 83.2 Gy at maximum. In this maximum, the prescribed dose is 88.1 Gy, and the minimum dose in the CTV is 67.4 Gy. In this case, the 95% isodose surface is conformed closely to the "static" CTV during treatment planning. CONCLUSIONS: Iso-NTCP escalation of the probability of tumor control is possible for lung tumors by reducing field sizes and allowing a larger dose inhomogeneity in the CTV. Optimum field sizes can be derived, having the highest EUD and highest minimum dose in the CTV under condition of a constant NTCP of the lungs. We conclude that the concept of homogeneous dose in the target volume is not the best approach to reach the highest probability of tumor control for lung tumors.

Humans↗

Variability in target volume delineation on CT scans of the breast.

PURPOSE: To determine the intra- and interobserver variation in delineation of the target volume of breast tumors on computed tomography (CT) scans in order to perform conformal radiotherapy. MATERIALS AND METHODS: The clinical target volume (CTV) of the breast was delineated in CT slices by four radiation oncologists on our clinically used delineation system. The palpable glandular breast tissue was marked with a lead wire on 6 patients before CT scanning, whereas 4 patients were scanned without a lead wire. The CTV was drawn by each observer on three separate occasions. Planning target volumes (PTVs) were constructed by expanding the CTV by 7 mm in each direction, except toward the skin. The deviation in the PTV extent from the average extent was quantified in each orthogonal direction for each patient to find a possible directional dependence in the observer variations. In addition, the standard deviation of the intra- and interobserver variation in the PTV volume was quantified. For each patient, the common volumes delineated by all observers and the smallest volume encompassing all PTVs were also calculated. RESULTS: The patient-averaged deviations in PTV extent were larger in the posterior (42 mm), cranial (28 mm), and medial (24 mm) directions than in the anterior (6 mm), caudal (15 mm), and lateral (8 mm) directions. The mean intraobserver variation in volume percentage (5.5%, 1 SD) was much smaller than the interobserver variation (17.5%, 1 SD). The average ratio between the common and encompassing volume for the four observers separately was 0.82, 0.74, 0.82, and 0.80. A much lower combined average ratio of 0.43 was found because of the large interobserver variations. For the observer who placed the lead wire, the intraobserver variation in volume was decreased by a factor of 4 on scans made with a lead wire in comparison to scans made without a lead wire. For the other observers, no improvement was seen. Based on these results, an improved delineation protocol was designed. CONCLUSIONS: Intra- and especially interobserver variation in the delineation of breast target volume on CT scans can be rather large. A detailed delineation protocol making use of CT scans with lead wires placed on the skin around the palpable breast by the delineating observer reduces the intraobserver variation. To reduce the interobserver variation, better imaging techniques and pathology studies relating glandular breast tissue to imaging may be needed to provide more information on the extent of the clinical target volume.

Breast Neoplasms↗

The potential impact of treatment variations on the results of radiotherapy of the internal mammary lymph node chain: a quality-assurance report on the dummy run of EORTC Phase III randomized trial 22922/10925 in Stage I--III breast cancer(1).

PURPOSE: To present the results of the dummy run of the European Organization for Research and Treatment of Cancer (EORTC) trial investigating the role of adjuvant internal mammary and medial supraclavicular (IM-MS) irradiation in Stage I--III breast cancer. METHODS AND MATERIALS: All participating institutions were asked to produce a treatment plan without (Arm 1) and with (Arm 2) simultaneous IM-MS irradiation of 1 patient after mastectomy and of 1 patient after lumpectomy. Thirty-two dummy runs have been evaluated for compliance to protocol guidelines, with respect to treatment technique and dose prescription. RESULTS: A number of more or less important deviations in treatment setup and prescription have been found. The dose in the IM-MS region deviated significantly from the prescribed dose in 10% of the cases for Arm 1, and in 21% for Arm 2. Assuming a true 5% 10-year survival benefit from optimal IM-MS irradiation, an increase of only 3.8% will be found due to this suboptimal dose distribution. CONCLUSION: In the dummy run, a number of potential systematic protocol deviations that might lead to false-negative results were detected. By providing recommendations to the participating institutions, we expect to improve the interinstitutional consistency and to promote a high quality irradiation in all institutions participating in the trial.

Breast Neoplasms↗

Accurate in vivo dosimetry of a randomized trial of prostate cancer irradiation.

PURPOSE: To guarantee an accurate dose delivery, within +/- 2.5%, in a Phase III randomized trial of prostate cancer irradiation (68 vs. 78 Gy) by means of a comprehensive in vivo dosimetry program. METHODS AND MATERIALS: Prostate patients are generally treated in our clinic with a 3-field isocentric technique: an 8-MV anteroposterior beam and 2 18-MV wedged laterals. All fields are shaped conformally to the PTV. Patients were randomized between two dose levels of 68 Gy and 78 Gy. During treatment, the entrance and exit dose were measured for each patient with diodes. Special 2.5-mm thick steel build-up caps were applied to make the diodes appropriate for measurements in 18-MV photon beams as well. Portal images were used to verify the correct position of the diodes and to detect and correct for gas filling in the rectum that may influence the exit dose reading. Entrance and exit dose measurements were converted to midplane dose, which was used in combination with a depth dose correction to obtain the dose at the specification point. An action level of 2.5% was applied. RESULTS: The added build-up for the diodes in the 18-MV beams resulted in correction factors that were only slightly sensitive to changes in beam setup and comparable to the corrections used in the 8-MV beams for diodes without extra build-up. The calibration factor increased almost linearly with cumulative dose: 0.7%/kGy for the 8-MV and 1.2%/kGy for the 18-MV photon beams. The introduction of average correction factors made the analysis easier, while keeping the accuracy within acceptable limits. In a period of 3 years, 225 patients were analyzed, from which 8 patients needed to be corrected. The average ratio of measured and prescribed dose was 1.009 (standard deviation [SD] 0.012) for the total group treated on two linear accelerators. When the results were analyzed per accelerator, the ratios were 1.002 (SD, 0.001) for Accelerator A and 1.015 (SD, 0.001) for Accelerator B. This difference could be attributed to the cumulative effect of three small imperfections in the performance of Accelerator B that were well within the limits of our quality assurance program. CONCLUSION: Diodes can be used for accurate in vivo dosimetry during prostate irradiation in high-energy photon beams. The dose delivery in this randomized trial is guaranteed within the 2.5% limits on an individual patient basis. This could not be achieved without the in vivo dosimetry program, despite our high-standard quality assurance program of treatment delivery.

Algorithms↗

Planning, computer optimization, and dosimetric verification of a segmented irradiation technique for prostate cancer.

PURPOSE: To develop and verify a multisegment technique for prostate irradiation that results in better sparing of the rectal wall compared to a conventional three-field technique, for patients with a concave-shaped planning target volume (PTV) overlapping the rectal wall. METHODS AND MATERIALS: Five patients have been selected with various degrees of overlap between PTV and rectal wall. The planned dose to the ICRU reference point is 78 Gy. The new technique consists of five beams, each having an open segment covering the entire PTV and several smaller segments in which the rectum is shielded. Segment weights are computer-optimized using an algorithm based on simulated annealing. The score function to be minimized consists of dose-volume constraints for PTV, rectal wall, and femoral heads. The resulting dose distribution is verified for each patient by using point measurements and line scans made with an ionization chamber in a water tank and by using film in a cylindrical polystyrene phantom. RESULTS: The final number of segments in the five-field technique ranges from 7 to 9 after optimization. Compared to the standard three-field technique, the maximum dose to the rectal wall decreases by approximately 3 Gy for patients with a large overlap and 1 Gy for patients with no overlap, resulting in a reduction of the normal tissue complication probability (NTCP) by a factor of 1.3 and 1.2, respectively. The mean dose to the PTV is the same for the two techniques, but the dose distribution is slightly less homogeneous with the five-field technique (Average standard deviation of five patients is 1.1 Gy and 1.7 Gy for the three-field and five-field technique, respectively). Ionization chamber measurements show that in the PTV, the calculated dose is in general within 1% of the measured dose. Outside the PTV, systematic dose deviations of up to 3% exist. Film measurements show that for the complete treatment, the position of the isodose lines in sagittal and coronal planes is calculated fairly accurately, the maximum distance between measured and calculated isodoses being 4 mm. CONCLUSIONS: We developed a relatively simple multisegment "step-and-shoot" technique that can be delivered within an acceptable time frame at the treatment machine (Extra time needed is approximately 3 minutes). The technique results in better sparing of the rectal wall compared to the conventional three-field technique. The technique can be planned and optimized relatively easily using automated procedures and a predefined score function. Dose calculation is accurate and can be verified for each patient individually.

Algorithms↗

Set-up verification using portal imaging; review of current clinical practice.

In this review of current clinical practice of set-up error verification by means of portal imaging, we firstly define the various types of set-up errors using a consistent nomenclature. The different causes of set-up errors are then summarized. Next, the results of a large number of studies regarding patient set-up verification are presented for treatments of patients with head and neck, prostate, pelvis, lung and breast cancer, as well as for mantle field/total body treatments. This review focuses on the more recent studies in order to assess the criteria for good clinical practice in patient positioning. The reported set-up accuracy varies widely, depending on the treatment site, method of immobilization and institution. The standard deviation (1 SD, mm) of the systematic and random errors for currently applied treatment techniques, separately measured along the three principle axes, ranges from 1.6-4.6 and 1.1-2.5 (head and neck), 1.0-3.8 and 1.2-3.5 (prostate), 1.1-4.7 and 1.1-4.9 (pelvis), 1.8-5.1 and 2.2-5.4 (lung), and 1.0-4.7 and 1.7-14.4 (breast), respectively. Recommendations for procedures to quantify, report and reduce patient set-up errors are given based on the studies described in this review. Using these recommendations, the systematic and random set-up errors that can be achieved in routine clinical practice can be less than 2.0 mm (1 SD) for head and neck, 2.5 mm (1 SD) for prostate, 3.0 mm (1 SD) for general pelvic and 3.5 mm (1 SD) for lung cancer treatment techniques.

Breast Neoplasms↗

The effect of breathing and set-up errors on the cumulative dose to a lung tumor.

BACKGROUND AND PURPOSE: To assess the impact of both set-up errors and respiration-induced tumor motion on the cumulative dose delivered to a clinical target volume (CTV) in lung, for an irradiation based on current clinically applied field sizes. MATERIALS AND METHODS: A cork phantom, having a 50 mm spherically shaped polystyrene insertion to simulate a gross tumor volume (GTV) located centrally in a lung was irradiated with two parallel opposed beams. The planned 95% isodose surface was conformed to the planning target volume (PTV) using a multi leaf collimator. The resulting margin between the CTV and the field edge was 16 mm in beam's eye view. A dose of 70 Gy was prescribed. Dose area histograms (DAHs) of the central plane of the CTV (GTV+5 mm) were determined using radiographic film for different combinations of set-up errors and respiration-induced tumor motion. The DAHs were evaluated using the population averaged tumor control probability (TCP(pop)) and the equivalent uniform dose (EUD) model. RESULTS: Compared with dose volume histograms of the entire CTV, DAHs overestimate the impact of tumor motion on tumor control. Due to the choice of field sizes a large part of the PTV will receive a too low dose resulting in an EUD of the central plane of the CTV of 68.9 Gy for the static case. The EUD drops to 68.2, 66.1 and 51.1 Gy for systematic set-up errors of 5, 10 and 15 mm, respectively. For random set-up errors of 5, 10 and 15 mm (1 SD), the EUD decreases to 68.7, 67.4 and 64.9 Gy, respectively. For similar amplitudes of respiration-induced motion, the EUD decreases to 68.8, 68.5 and 67.7 Gy, respectively. For a clinically relevant scenario of 7.5 mm systematic set-up error, 3 mm random set-up error and 5 mm amplitude of breathing motion, the EUD is 66.7 Gy. This corresponds with a tumor control probability TCP(pop) of 41.7%, compared with 50.0% for homogeneous irradiation of the CTV to 70 Gy. CONCLUSION: Systematic set-up errors have a dominant effect on the cumulative dose to the CTV. The effect of breathing motion and random set-up errors is smaller. Therefore the gain of controlling breathing motion during irradiation is expected to be small and efforts should rather focus on minimizing systematic errors. For the current clinically applied field sizes and a clinically relevant combination of set-up errors and breathing motion, the EUD of the central plane of the CTV is reduced by 3.3 Gy, at maximum, relative to homogeneous irradiation of the CTV to 70 Gy, for our worst case scenario.

Lung Neoplasms↗

Impact of simple tissue inhomogeneity correction algorithms on conformal radiotherapy of lung tumours.

BACKGROUND AND PURPOSE: Conformal radiotherapy requires accurate dose calculation at the dose specification point, at other points in the planning target volume (PTV) and in organs at risk. To assess the limitations of treatment planning of lung tumours, errors in dose values, calculated by some simple tissue inhomogeneity correction algorithms available in a number of currently applied treatment planning systems, have been quantified. MATERIALS AND METHODS: Single multileaf collimator-shaped photon beams of 6, 8, 15 and 18 MV nominal energy were used to irradiate a 50 mm diameter spherical solid tumour, simulated by polystyrene, which was located centrally inside lung tissue, simulated by cork. The planned dose distribution was made conformal to the PTV, which was a 15 mm three-dimensional expansion of the tumour. Values of both the absolute dose at the International Commission on Radiation Units and Measurement (ICRU) reference point and relative dose distributions inside the PTV and in the lung were calculated using three inhomogeneity correction algorithms. The algorithms investigated in this study are the pencil beam algorithm with one-dimensional corrections, the modified Batho algorithm and the equivalent path length algorithm. The calculated data were compared with measurements for a simple beam set-up using radiographic film and ionization chambers. RESULTS: For this specific configuration, deviations of up to 3.5% between calculated and measured values of the dose at the ICRU reference point were found. Discrepancies between measured and calculated beam fringe values (distance between the 50 and 90% isodose lines) of up to 14 mm have been observed. The differences in beam fringe and penumbra width (20-80%) increase with increasing beam energy. Our results demonstrate that an underdosage of the PTV up to 20% may occur if calculated dose values are used for treatment planning. The three algorithms predict a considerably higher dose in the lung, both along the central beam axis and in the lateral direction, compared with the actual delivered dose values. CONCLUSIONS: The dose at the ICRU reference point of such a tumour in lung geometry is calculated with acceptable accuracy. Differences between calculated and measured dose distributions are primarily due to changes in electron transport in the lung, which are not adequately taken into account by the simple tissue inhomogeneity correction algorithms investigated in this study. Particularly for high photon beam energies, clinically unacceptable errors will be introduced in the choice of field sizes employed for conformal treatments, leading to underdosage of the PTV. In addition, the dose to the lung will be wrongly predicted which may influence the choice of the prescribed dose level in dose-escalation studies.

Algorithms↗

Implementation of a forearm support to reduce the amount of irradiated lung and heart in radiation therapy of the breast.

We compared simulator images of medial tangential fields taken in two positions: (1) with the ipsilateral arm abducted, holding a 'L-bar' armrest and (2) with both arms extended above the head in a forearm support. The average maximum heart distance as well as the central lung distance decreased significantly by 3.4 (SE 0.9) and 4.7 (SE 1.1) mm, respectively, when the new forearm support was used. The estimated normal tissue complication probability for excess cardiac mortality decreased by on average 3.1% (SE 1.3%). For some patients, a greater amount of the axilla was included in the field. We recommend the use of the forearm support during breast cancer treatment with tangential fields to decrease the amount of heart and lung inside the fields.

Breast Neoplasms↗

Variation of sensitometric curves of radiographic films in high energy photon beams.

Film dosimetry is an important tool for the verification of irradiation techniques. The shape of the sensitometric curve depends on the type of film as well as on the irradiation and processing conditions. Existing data concerning the influence of irradiation geometry on the sensitometric curve are conflicting. In particular the variation of optical density, OD, with field size and depth in a phantom shows large differences in magnitude between various authors. This variation, as well as the effect of beam energy and film plane orientation on OD, was therefore investigated for two types of film, Kodak X-Omat V and Agfa Structurix D2. Films were positioned in a solid phantom, either perpendicular or (almost) parallel to the beam axis, and irradiated to different dose levels using various photon beams (Co-60, 6 MV, 15 MV, 18 MV, 45 MV). It was found that the sensitometric curves of the Kodak film derived at different depths are almost identical for the four x-ray beams. For the Kodak film the differences in OD with depth are less than 2%, except for the Co-60 beam, where the difference is about 4% at 10 cm depth for a 15 cm x 15 cm field. The slope of the sensitometric curve of the Agfa film is somewhat more dependent on photon beam energy, depth and field size. The sensitometric curves of both types of film are almost independent of the film plane orientation, except for shallow depths. For Co-60 and for the same dose, the Kodak and Agfa films gave at dose maximum an OD lower by 4% and 6%, respectively, for the parallel compared to the perpendicular geometry. Good dosimetric results can be obtained if films from the same batch are irradiated with small to moderate field sizes (up to about 15 cm x 15 cm), at moderate depths (up to about 15 cm), using a single calibration curve, e.g., for a 10 cm x 10 cm field.

Biophysical Phenomena↗

A treatment planning method to correct dose distributions distorted by setup verification fields.

PURPOSE: Portal images of conformal treatment fields are often not suitable for setup verification purposes because they contain insufficient bony structures. Therefore, additional rectangular fields are frequently applied for setup verification purposes. It is the aim of this study to reduce the dose distortions induced by these extra fields by appropriately adjusting the beam weights and wedge angles of the treatment fields. METHODS AND MATERIALS: A second treatment plan for the setup verification session is generated, with an identical beam setup as the original plan, but which also includes two orthogonal setup verification fields. An algorithm has been developed, based on vector analysis methods, that adjusts the beam weights and wedge angles of the treatment fields in such a way that both the dose at the isocenter and the dose homogeneity over the planning target volume (PTV) are conserved. RESULTS: The algorithm has been applied to three clinical cases. The number of MUs for the setup verification fields, using a liquid-filled electronic portal imaging device, varied between 16 MU in the head and neck region up to 34 MU for lateral images in the pelvic region. In all cases, the method yielded a treatment plan including two orthogonal setup verification fields with a similar dose distribution over the PTV as the original treatment plan without the setup verification fields. CONCLUSION: The dose distortions resulting from the acquisition of orthogonal verification imaging can be neutralized by modifying the original beam weights and wedge angles of the treatment fields.

Algorithms↗