B J Rensing

Publications and source records attributed to B J Rensing.

At least 19 recordsLinked to original sources

Contrast-enhanced MRA and 3D visualization of pulmonary venous anatomy to assist radiofrequency catheter ablation.

In pulmonary vein isolation as a treatment for atrial fibrillation the proximal part of the pulmonary veins is catheterized. A protocol for preinterventional assessment of pulmonary vein anatomy was developed, based on contrast-enhanced magnetic resonance angiography (MRA) in combination with three-dimensional visualization to tailor periprocedural angiography. The results allow for assessment of the number, morphology, and location of the ostia of the pulmonary veins, as well as complicating anatomical variations, such as common trunks and aberrant courses.

Adult↗

Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate.

OBJECTIVE: To evaluate the impact of heart rate on the diagnostic accuracy of coronary angiography by multislice spiral computed tomography (MSCT). DESIGN: Prospective observational study. PATIENTS: 78 patients who underwent both conventional and MSCT coronary angiography for suspicion of de novo coronary artery disease (n=53) or recurrent coronary artery disease after percutaneous intervention (n=25). SETTING: Tertiary referral centre. METHODS: Intravenously contrast enhanced MSCT coronary angiography was done during a single breath hold, and ECG synchronised images were reconstructed retrospectively. All coronary segments of > or = 2.0 mm without stents were evaluated by two investigators and compared with quantitative coronary angiography. Patients were classified according to the average heart rate (mean (SD)) into three equally sized groups: group 1, 55.8 (4.1) beats/min; group 2, 66.6 (2.8) beats/min; group 3, 81.7 (8.8) beats/min. RESULTS: Image quality was sufficient for analysis in 78% of the coronary segments in patients in group 1, 73% in group 2, and 54% in group 3 (p < 0.01). The sensitivity and specificity for detecting significant stenoses (> or = 50% lumen reduction) in these assessable segments were: 97% (95% confidence interval (CI) 84% to 100%) and 96% in group 1; 74% (52% to 89%) and 94% in group 2; and 67% (33% to 90%) and 94% in group 3 (p < 0.05). Accounting for all segments of > or = 2.0 mm, including lesions in non-assessable segments as false negatives, the sensitivity decreased to 82% (28/34 lesions, 95% CI 69% to 91%), 61% (14/23 lesions, 42% to 77%), and 32% (6/19 lesions, 15% to 50%), respectively (p < 0.01). CONCLUSIONS: MSCT allows reliable coronary angiography in patients with low heart rates.

Confidence Intervals↗

Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up.

BACKGROUND: We have previously reported a virtual absence of neointimal hyperplasia 4 months after implantation of sirolimus-eluting stents. The aim of the present investigation was to determine whether these results are sustained over a period of 1 year. METHODS AND RESULTS: Forty-five patients with de novo coronary disease were successfully treated with the implantation of a single sirolimus-eluting Bx VELOCITY stent in São Paulo, Brazil (n=30, 15 fast release [group I, GI] and 15 slow release [GII]) and Rotterdam, The Netherlands (15 slow release, GIII). Angiographic and volumetric intravascular ultrasound (IVUS) follow-up was obtained at 4 and 12 months (GI and GII) and 6 months (GIII). In-stent minimal lumen diameter and percent diameter stenosis remained essentially unchanged in all groups (at 12 months, GI and GII; at 6 months, GIII). Follow-up in-lesion minimal lumen diameter was 2.28 mm (GIII), 2.32 mm (GI), and 2.48 mm (GII). No patient approached the >/=50% diameter stenosis at 1 year by angiography or IVUS assessment, and no edge restenosis was observed. Neointimal hyperplasia, as detected by IVUS, was virtually absent at 6 months (2+/-5% obstruction volume, GIII) and at 12 months (GI=2+/-5% and GII=2+/-3%). CONCLUSIONS: This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.

Blood Vessel Prosthesis Implantation↗

Coronary angiography with multi-slice computed tomography.

BACKGROUND: A new generation of subsecond multi-slice computed tomography (MSCT) scanners, which allow complete coronary coverage, are becoming widely available. We investigated the potential value of MSCT angiography in a range of coronary disorders. METHODS: We studied 35 patients, including 11 who had undergone percutaneous transluminal coronary angioplasty and four who had had coronary-artery bypass grafts, by both MSCT and conventional coronary angiography. After intravenous injection of a non-ionic contrast medium with high iodine content, the entire heart was scanned within a single breath-hold. The total examination time was no more than 20 min. The retrospective electrocardiographically gated reconstruction source images and three-dimensional reconstructed volumes were analysed by two investigators, unaware of the results of conventional angiography. FINDINGS: In the 31 patients without previous coronary surgery, 173 (73%) of the 237 proximal and middle coronary segments were assessable. In the assessable segments, 17 of 21 significant stenoses (>50% reduction of vessel diameter) were correctly diagnosed. The non-assessable segments included four lesions. Misinterpretations were mainly the result of severe calcification of the vessel wall. Segments with implanted stents were poorly visualised, but stent patency could be assessed in all cases. Of the 17 segments of bypass grafts, 15 were assessable and four of five graft lesions were detected. Two cases of anomalous coronary anatomy could be visualised well. INTERPRETATION: These preliminary data suggest that MSCT allows non-invasive imaging of coronary-artery stenoses and has potential to develop into a reliable clinical technique.

Adult↗

Coronary restenosis elimination with a sirolimus eluting stent: first European human experience with 6-month angiographic and intravascular ultrasonic follow-up.

AIMS: Coronary stenting is limited by a 10%-60% restenosis rate due to neointimal hyperplasia. Sirolimus is a macrocyclic lactone agent that interacts with cell-cycle regulating proteins and inhibits cell division between phases G1 and S1. The hypothesis tested in this study is that local delivery of sirolimus with an eluting stent can prevent restenosis. METHODS AND RESULTS: Fifteen patients were treated with 18 mm sirolimus eluting BX VELOCITY stents. Quantitative angiography and three-dimensional quantitative intravascular ultrasound were performed at implantation and at the 6 months follow-up. All stent implantations were successful. One patient died on day 2, of cerebral haemorrhage and one patient suffered a subacute stent occlusion due to edge dissection (re-PTCA, CKMB 42). At 9 months no further adverse events had occurred and all patients were angina free. Quantitative coronary angiography revealed no change in minimal lumen diameter and percent diameter stenosis and hence no in-lesion or in-stent restenosis. Quantitative intravascular ultrasound showed that intimal hyperplasia volume and percent obstruction volume at follow-up were negligible at 5.3 mm(3)and 1.8%, respectively. No edge effect was observed in the segments proximal and distal to the stents. CONCLUSION: Implantation of a sirolimus-eluting stent seems to effectively prevent intimal hyperplasia.

Adult↗

Coronary artery fly-through using electron beam computed tomography.

BACKGROUND: Virtual reality techniques have recently been introduced into clinical medicine. This study examines the possibility of coronary artery fly-through using a dataset obtained by noninvasive coronary angiography with contrast-enhanced electron-beam computed tomography. METHODS AND RESULTS: Ten patients were examined, and 40 to 60 transaxial tomograms (thickness, 1.5 mm; in-plane pixel dimensions, approximately 0.5x0.5 mm) were obtained after intravenous contrast injection. The datasets were processed on a graphics workstation using volume-rendering software. For fly-throughs, the contrast-enhanced lumen was made transparent and other tissue was made opaque. Then, key frames were selected in a path through the vessel, with software interpolation of frames between key frames. A typical movie contained 150 to 300 frames (10 to 15 key frames). Fly-throughs of coronary bypass grafts (n=3), left anterior descending arteries (LAD; n=6), and the intermediate branch (n=1) were reconstructed. Coronary calcifications were seen in 3 patients. The fly-through of the intermediate branch, the bypass grafts, and one of the LADs did not show any irregularities. In 2 cases, a stenosis was visible in the LAD; its presence was confirmed by conventional coronary angiography. CONCLUSIONS: Recent developments in fast-volume rendering using special-purpose hardware in combination with noninvasive coronary angiography with electron beam computed tomography have provided the possibility of performing coronary artery fly-throughs.

Calcinosis↗

Stentocarditis.

Explore the source record for details and available documents.

Abscess↗

MR coronary angiography with breath-hold targeted volumes: preliminary clinical results.

PURPOSE: To assess the clinical value of a magnetic resonance (MR) coronary angiography strategy involving a small targeted volume to image one coronary segment in a single breath hold for the detection of greater than 50% stenosis. MATERIALS AND METHODS: Thirty-eight patients referred for elective coronary angiography were included. The coronary arteries were localized during single-breath-hold, three-dimensional imaging of the entire heart. MR coronary angiography was then performed along the major coronary branches with a double-oblique, three-dimensional, gradient-echo sequence. Conventional coronary angiography was the reference-standard method. RESULTS: Adequate visualization was achieved with MR coronary angiography in 85%-91% of the proximal coronary arterial branches and in 38%-76% of the middle and distal branches. Overall, 187 (69%) of 272 segments were suitable for comparison between conventional and MR coronary angiography. The diagnostic accuracy of MR coronary angiography for the detection of hemodynamically significant stenoses was 92%; sensitivity, 68%; and specificity, 97%. The sensitivity in individual segments was 50%-77%, whereas the specificity was 94%-100%. CONCLUSION: Adequate visualization of the major coronary arterial branches was possible in the majority of patients. The observed accuracy of MR coronary angiography for detection of hemodynamically significant coronary arterial stenosis is promising, but it needs to be higher before this modality can be used reliably in a clinical setting.

Adult↗

Stenting with a true bifurcated stent: acute and mid-term follow-up results.

Percutaneous therapy of coronary bifurcated lesions is associated with greater risk of acute complications and late restenosis. Numerous innovative techniques using various stent types have been proposed. We report the first clinical use of a truly bifurcated stent (Bard XT Carina). The implantation procedure, favorable medium-term angiographic and 1-year clinical follow-up of the first human use in a 43-year-old female are illustrated with angiography and intravascular ultrasound. As a single prosthesis that effectively covers the bifurcation, this stent presents appealing alternative for the treatment of coronary bifurcation lesions when compared to methods that involve multiple-stent implantation. Cathet. Cardiovasc. Intervent. 47:361-369, 1999.

Abciximab↗

Spontaneous dissections of all three coronary arteries in a 33-week-pregnant woman.

The clinical course and angiographic follow-up of a woman with spontaneous coronary dissections in all three coronary arteries during the third trimester of pregnancy is described. Mother and child survived and subsequent clinical course was uneventful. At 6-month follow-up, dissections in the right and circumflex coronary artery had healed completely. At the site of the dissection in the LAD, an aneurysm had formed. This is to our knowledge the first report of antepartum and antemortem diagnosis of pregnancy related coronary dissections in all three coronary arteries. Cathet. Cardiovasc. Intervent. 48:207-210, 1999.

Adult↗

Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique.

BACKGROUND: Magnetic resonance coronary angiography is challenging because of the motion of the vessels during cardiac contraction and respiration. Additional challenges are the small calibre of the arteries and their complex three dimensional course. Respiratory gating, turboflash acquisition, and volume rendering techniques may meet the necessary requirements for appropriate visualisation. OBJECTIVE: To determine the diagnostic accuracy of respiratory gated magnetic resonance imaging (MRI) for the detection of significant coronary artery stenoses evaluated with three dimensional postprocessing software. METHODS: 32 patients referred for elective coronary angiography were studied with a retrospective respiratory gated three dimensional gradient echo MRI technique. Resolution was 1.9 x 1.25 x 2 mm. After manual segmentation three dimensional evaluation was performed with a volume rendering technique. RESULTS: Overall 74% (range 50% to 90%) of the proximal and mid coronary artery segments were visualised with an image quality suitable for further analysis. Sensitivity and specificity for the detection of significant stenoses were 50% and 91%, respectively. CONCLUSIONS: Volume rendering of respiratory gated MRI techniques allows adequate visualisation of the coronary arteries in patients with a regular breathing pattern. Significant lesions in the major coronary artery branches can be identified with a moderate sensitivity and a high specificity.

Adult↗

In vivo assessment of three dimensional coronary anatomy using electron beam computed tomography after intravenous contrast administration.

Intravenous coronary angiography with electron beam computed tomography (EBCT) allows for the non-invasive visualisation of coronary arteries. With dedicated computer hardware and software, three dimensional renderings of the coronary arteries can be constructed, starting from the individual transaxial tomograms. This article describes image acquisition, postprocessing techniques, and the results of clinical studies. EBCT coronary angiography is a promising coronary artery imaging technique. Currently it is a reasonably robust technique for the visualisation and assessment of the left main and left anterior descending coronary artery. The right and circumflex coronary arteries can be visualised less consistently. Improvements in image acquisition and postprocessing techniques are expected to improve visualisation and diagnostic accuracy of the technique.

Contrast Media↗

Magnetic resonance imaging of the coronary arteries: anatomy of the coronary arteries and veins in three-dimensional imaging.

Magnetic resonance imaging of coronary arteries will visualize, besides the arteries, the myocardium, blood in the cavities and cardiac veins. This will hamper the application of projectional visualization techniques such as those used in conventional coronary angiography. Volume rendering, a different visualization technique, can be used to create a three-dimensional impression of a magnetic resonance data set on a two-dimensional surface. In this article, we will review the volume-rendering technique and anatomy of the coronary arteries and veins in the obtained images. Also we will discuss the relation between arteries and veins and the possible sites of confusion.

Animals↗

Intravenous coronary angiography by electron beam computed tomography: a clinical evaluation.

BACKGROUND: -Noninvasive detection of coronary stenoses with electron beam CT (EBCT) after intravenous injection of contrast medium has recently emerged. We sought to determine the diagnostic accuracy of EBCT angiography in the clinical setting using conventional coronary angiography as the "gold standard." METHODS AND RESULTS: Thirty-seven patients (30 men) were investigated. After intravenous injection of 150 mL of contrast medium, 40 to 60 consecutive transaxial tomograms, covering the proximal and middle parts of the coronary arteries, were obtained with ECG triggering at end diastole during breath-holding. Three-dimensional reconstructions of the proximal and middle parts of the arteries were compared with the conventional angiograms. Of the 259 proximal and middle coronary segments, 211 (81%) were analyzable by EBCT. Of the left anterior descending coronary artery (LAD) segments, 95% were assessable. Right coronary artery (RCA) and left circumflex artery (LCx) segments were assessable in 66% and 76%, respectively. Overall sensitivity and specificity to detect a >50% diameter stenosis were 77% and 94%, respectively. This was 82% and 92% for the LAD, 60% and 97% for the RCA, and 83% and 89% for the LCx (all figures based on assessable lesions). CONCLUSIONS: Intravenous EBCT coronary angiography is a promising coronary imaging technique. The technique is not yet robust enough to be an alternative to conventional coronary angiography. It can detect and rule out significant coronary artery disease of the left main proximal and mid portions of the LAD with good accuracy.

Adult↗

Intravenous electron-beam computed tomographic coronary angiography for segmental analysis of coronary artery stenoses.

OBJECTIVES: We sought to identify and localize significant coronary stenoses on a segmental basis by electron-beam computed tomography (EBCT) and intravenous administration of a contrast agent. BACKGROUND: The clinical applicability and limitations of intravenous EBCT coronary angiography have not been defined. METHODS: EBCT was performed within 24 h of selective coronary angiography (SCA) in 28 patients (19 men and 9 women, mean [+/-SD] age 60 +/- 10 years). After examination for coronary calcium, EBCT coronary angiography was performed using overlapping slices (in-plane resolution 0.34 to 0.41 mm) with a nominal slice thickness of 1 mm. Based on quantitative analysis of SCA, lumen diameter narrowing > or = 50% (i.e., significant stenoses) was evaluated in 8 (major) or 12 (including side branches) coronary artery segments, using both two-dimensional (tomographic) and three-dimensional (volume) data sets. RESULTS: Of the 330 segments assessable by SCA, 237 (72%) were visualized by EBCT. The sensitivity (+/-SE) for detection of significant stenoses was 82 +/- 6%; specificity was 88 +/- 2%; positive and negative predictive values were 57 +/- 7% and 96 +/- 2%, respectively; and overall accuracy was 87 +/- 2%. If only eight (major) coronary artery segments were considered, 194 (88%) of 221 segments were visualized, and the overall accuracy was 90 +/- 2%. Seven (18%) of 38 significantly stenotic segments were classified as having < 50% stenoses by EBCT. Six of these segments (86%), but only 9 (29%) of the 31 correctly classified stenotic segments, were severely calcified (area > 20 mm2, p = 0.02). In 23 (12%) of 199 nonstenotic segments falsely classified as having > or = 50% stenosis by EBCT, the lumen diameter was significantly smaller than that of the segments correctly classified as negative (mean [+/-SD] 1.5 +/- 0.8 vs. 2.9 +/- 1.1 mm, p < 0.001). CONCLUSIONS: Intravenous EBCT coronary angiography allows for accurate segmental evaluation of significant disease in the major coronary arteries and may be of value for ruling out significant disease. The main determinant of false negative results is substantial segmental calcification, whereas the main determinant of false positive results is small vessel size.

Adult↗