PubMed Health⌕ Search

Biomedical subjects

B J Wintersperger

Publications and source records attributed to B J Wintersperger.

At least 19 recordsLinked to original sources

Interventional embolization of a giant pulmonary arteriovenous malformation with right-left-shunt associated with hereditary hemorrhagic telangiectasia.

A 46-year old woman experienced an episode of arterial desaturation despite administration of 100% oxygen during anesthetization for an elective laparoscopy. Further evaluation revealed a giant pulmonary arteriovenous malformation (PAVM) with right-left shunt associated with previously undiagnosed hereditary hemorrhagic telangiectasia (HHT, Morbus Osler- Weber-Rendu). The PAVM was treated interventionally with an Amplatzer duct occluder. Transcatheter embolization of the PAVM was well tolerated with symptomatic and hemodynamic improvement. CT scan after six months demonstrated correct position of the duct occluder in the left pulmonary artery with nearly complete occlusion of the feeding vessel.PAVMs are rare direct communications between pulmonary arteries and veins, associated with HHT in the majority of cases and often presenting with dyspnea or major neurological complications due to paradoxic embolism. In this case report, we present a rational and stepwise diagnostic workup for this rare medical condition and show that transcatheter embolization is an appropriate treatment for larger malformations.

Arteriovenous Malformations↗

Dose reduction and image quality in MDCT colonography using tube current modulation.

OBJECTIVE: The purpose of our study was to evaluate the dose reduction potential of combined online (x- and y-axes) and topogram-based (l) X-ray tube current modulation in CT colonography in a screening population. MATERIALS AND METHODS: Eighty asymptomatic individuals underwent CT colonography screening for colon polyps. A 16-MDCT scanner (Somatom Sensation 16) was used. Forty patients were examined at 120 kVp and 120 effective mAs (supine) and 40 effective mAs (prone) using online x- and y-axis tube current modulation. Another 40 patients were scanned using combined x-, y-, and z-axis tube current modulation. Individual patient radiation exposure was determined using the dose-length product. Image noise was determined by Hounsfield unit measurements in the colonic lumen at four anatomic levels. Image quality was rated on a 5-point confidence scale by two independent reviewers. The unpaired Student's t test (for radiation dose, image noise) and Wilcoxon's test (for image quality) were used to test for statistically significant differences between these values. RESULTS: Radiation dose was significantly lower in the patient group scanned with x-, y-, and z-axis tube current modulation than in the group scanned with x- and y-axis tube current modulation (supine: 4.24 vs 6.50 mSv, p < 0.0001; prone: 1.61 vs 2.38 mSv, p < 0.0001). Radiation dose was reduced by 35% (supine) and 33% (prone). No statistically significant difference was seen in overall image noise (supine: 15.9 vs 16.3 H, p = 0.13; prone: 23.5 vs 24.8 H, p = 0.44) or image quality (supine: 4.6 vs 4.5, p = 0.62; prone: 3.5 vs 3.6, p = 0.54). CONCLUSION: Combined x-, y-, and z-axis tube current modulation leads to a significant reduction of radiation exposure in CT colonography without loss of image quality.

Aged↗

[Evaluating multislice computed tomography for imaging coronary atherosclerosis].

PURPOSE: The purpose of this study was the evaluation of multidetector-row computed tomography (MDCT) for the assessment of atherosclerotic coronary artery vessel wall changes. METHODS: In an ex vivo study, 17 human hearts were scanned with MDCT and results were compared to histopathology. Morphologic imaging criteria of MDCT for various plaque-types were developed. In a following in vivo study, 94 coronary MDCT angiograms (MDCTA) of patients with suspected coronary artery disease (CAD) were reviewed retrospectively, assessing the diagnostic value of the coronary MDCTA, and determining the number and correlations of the various plaques types as described in the ex vivo study. Additionally, volumetry of calcified and noncalcified plaque components was performed. RESULTS: In the ex vivo study, MDCT showed a high sensitivity for calcified and non-calcified plaques. Comparing the results with histopathology, characteristic image criteria could be determined for lipid-rich, fibrous and calcified plaque components. Reviewing the contrastenhanced in-vivo MDCT coronary angiographies, presence of noncalcified plaques was proven in 38% of the patients. In 5 patients with a calcium score of 0, presence of coronary atherosclerosis was proven in the contrastenhanced scan. CONCLUSIONS: MDCT is able to differentiate various plaque components in an ex vivo setting as well as invivo. Contrastenhanced MDCT of the coronary arteries allows for the detection of noncalcified plaques. In vivo volumetry of noncalcified plaques is feasible.

Adult↗

[Indications for multislice CT angiography of coronary arteries].

INTRODUCTION: The newest generation of 16-detector-row CT allows displaying the anatomy and assessment of coronary artery disease (CAD) when slow regular sinus rhythm is present. METHODS: For morphological assessment of cardiac structures by using Multi-detector row CT a dedicated scan protocol is obligatory. The indication for coronary CT angiography (CTA) is currently under investigation by several study groups. RESULTS: Because of the limited spatial and temporal resolution and coronary calcium artefacts, it is not possible with multislice CT angiography to assess coronary arteries in patients with established coronary artery disease. The anatomy of the coronary arteries can well be displayed with this technique. CONCLUSION: The high negative predictive value of coronary CTA may justify the investigation of symptomatic patients with intermediate pretest probability of CAD. Moreover coronary CTA is suitable for patients for displaying the origin and course of abnormal coronary arteries.

Artifacts↗

[ECG-gated bypass CT angiography--application in imaging arterial bypasses].

Nowadays coronary artery bypass grafting is increasingly performed using arterial grafts. Purpose of the study was the evaluation of a appropriate 16 detector-row CT angiography protocol in patients after predominantly arterial bypass grafting. Fourteen patients after bypass grafting were including into the study and CT angiography carried out in the early postoperative period using a 16 detector-row CT system. To reduce cardiac pulsation artifacts data acquisition was implemented using ECG-gating algorithms. Overall 43 grafts (37 arterial, 6 venous) were examined. In 13 patients surgery had been performed using composite grafts with T or TY configuration. The mean heart rate was 74.1 bpm and showed a negative correlation to the image quality (r=-0.65; p=0.01). However, all data sets were diagnostic. Contrast injection protocol allowed for a homogeneous opacification throughout the vessels of interest. All non-delineationable grafts (5) showed a close proximity to the heart (T or Y grafts). Cardiac surgery is increasingly focusing on arterial revascularisation in bypass grafting and therefore leading to new demands for non-invasive bypass graft imaging. 16 detector-row CT allows a reliable visualization of even composite arterial grafts. However, for detection of grafts in the proximity of the heart a reduction of the heart rate (<65-70) still seems to be necessary.

Aged↗

[Determining global heart function with real time TrueFISP in one respiratory cycle].

Real-time multislice cine techniques lead to inaccurate results in ventricular volumes based on limited temporal resolution. The purpose of the study is to evaluate a real-time cine technique with parallel imaging algorithms in comparison to standard segmented techniques. Twelve patients underwent cardiac cine MRI using real-time multislice cine trueFISP. Temporal resolution was improved using parallel acquisition techniques (iPAT) and data acquisition was performed in a single breath-hold along the patients' short axis. Evaluation of EDV, ESV, EF and myocardial mass was performed and results compared to a standard segmented single-slice cine trueFISP. Combination of real-time cine trueFISP and iPAT provided a temporal resolution of 48 ms. Results of the multislice approach showed an excellent correlation to standard single-slice trueFISP for EDV (0.94, p <0.001), ESV (0.97, p <0.001) EF (0.99, p <0.001) and myocardial mass (0.93, p <0.001). No significant differences could be found. The use of parallel acquisition techniques (PAT) allow for a substantial improvement of temporal resolution in real-time cine MRI (<50 ms). Therefore these techniques enable an accurate and exact quantification of global ventricular function.

Algorithms↗

[CT angiography of the coronary arteries with a 16-row spiral tomograph. Effect of spatial resolution on image quality].

PURPOSE: To evaluate image quality of coronary CT angiography with retrospectively ECG-gated 16 multi-slice spiral CT (MSCT), reconstructed with 0.75 mm slice thickness for optimal spatial resolution and with 1.3 mm slice thickness, to produce spatial resolution comparable to a 4-MSCT. MATERIALS AND METHODS: Ten patients underwent coronary CT angiography with a 16-MSCT (Siemens Sensation 16, Forchheim, Germany) with 0.75 mm detector collimation. Raw helical CT data were retrospectively reconstructed using two different settings. Setting A: B20f smooth kernel, axial MPR with 1.3 mm slice thickness and 0.7 mm increment. Setting B: B35f "HeartView" medium-smooth kernel, 0.75 mm slice thickness, 0.5 mm increment. In the axial slices two regions of interest (ROIs) were placed in the area of the aortic root (AR) and more caudal in the area of the left ventricle (LV). Image noise was determined by the standard deviation of the CT numbers.Two readers determined visibility of coronary arteries by standardized maximum intensity projections (MIP) post-processing in left, right anterior and left anterior oblique projection plane from setting A and B. Each projection was rated on a five point rating scale concerning plaque delineation. Points determined for each data set were summed up and used for comparison. RESULTS: No significant difference between the CT-numbers was found for setting A and B (A: 283.0 in AR/295.9 in LV and B: 282,9 in AR/297.2 in LV; p >0.2). However, the image noise was significantly different for setting A and B (A: 4.46 in AR/1.67 in LV and B: 8.16 in AR/7.38 in LV; p <0.01). Better delineation of the coronary arteries and atherosclerotic lesions could be achieved from MIP projections in setting B compared to setting A. CONCLUSION: Higher image noise is present in coronary 16-MSCT with thin-slice reconstruction compared to simulated 4-MSCT. However the MIP-reconstructions benefit most from the higher spatial resolution.

Coronary Angiography↗

[Radiation dose and dose reduction in multidetector row CT (MDCT)].

Since its introduction a few years ago, multidetector row CT (MDCT) has become a widely used diagnostic procedure and has been proven to be a valuable tool for various indications. A major issue using this new modality is the inherent risk of applying increased radiation exposure, when compared to single-slice CT or other imaging modalities.However, MDCT offers some valuable options to save radiation exposure, such as choosing optimized exposure parameters or its superior dose efficiency in comparison to single-slice CT. Multi-phasic examinations should be restricted to indications where definitely necessary. Modern scanners offer intelligent tools for further reduction of radiation dose, such as ECG- or bodyshape-based realtime dose modulation. A new field of applications is the low-dose CT for early detection of diseases. While acquiring thin slices with high spatial resolution, the dose can be reduced to similar values as in conventional radiography, especially when examining under high-contrast conditions. Using all these various options available, radiation exposure can sometimes even be lower than using a conventional single-slice helical CT.

Artificial Intelligence↗

[New abdominal CT angiography protocol on a 16 detector-row CT scanner - first results].

PURPOSE: Purpose of this study was the implementation of a new abdominal CT angiography protocol on a 16 detector-row CT scanner and the comparison to selective catheter angiography. METHODS: 76 patients with various vascular disorders underwent abdominal CT angiography on a recently developed 16 detector-row CT scanner using submillimeter slice collimation (16 x 0.75 mm). Results were compared with mesenteric and/or hepatic angiography in 17 patients performed during tumor embolization. Opacification was provided using individually tailored contrast application with a test bolus setting. To evaluate the contrast injection protocol density measurements within the vessel lumen were performed. RESULTS: Diagnostic image quality was achieved in all patients with angiographic comparison (n = 17). Within the hepatic and mesenteric vasculature up to 4th generation vessels could be identified. Compared to selective angiography CT angiography provided equivalent morphologic information up to the detectable vessel generation. With the applied contrast application regimen there were no significant differences in vessel enhancement along the abdominal aorta and iliac arteries. CONCLUSION: 16 detector-row CT enables whole abdominal angiographic studies with submillimeter resolution in a single breath-hold. The improved spatial resolution enables for high quality 3D visualization. Compared to invasive angiography, 16 detector-row CT reveals equivalent morphologic information.

Abdomen↗

[Diagnosis of aortic aneurysm].

The aim of the study was to analyze the use and indication of 3 imaging modalities (CT, DSA and MRI) for patients with suspicion of aortic aneurysm. During 18 months 383 patients with suspicion of aortic aneurysm were examined with CT (SCT/MSCT), 17 with digital subtraction angiography (DSA), and 15 with MRI. Diagnostic DSA was performed in 7 cases for planning endoluminal therapy, in 7 cases because of unclear findings in CT and in 4 cases because of dissection of the aorta. MRI was performed in 12 cases with previously performed CT and in 3 cases as the only imaging modality because of intolerance to iodinated contrast material. CT is a well established and in most cases sufficient method for the examination of patients with the suspicion of aortic aneurysm. CT is widely available, and provides good image quality and a high diagnostic accuracy. Additional examinations with DSA or MRI are necessary in less than 5% of the patients.

Aged↗

[Reconstruction methods in postprocessing of CT- and MR-angiography of the aorta].

The aim of the study was to investigate the use of 2D and 3D reconstructions in examinations of the aorta with CT and MRI. Postprocessing of 5 data sets including 2D MPR reconstructions, 3D MIP reconstructions and 3D volume rendering reconstructions acquired with contrast enhanced CTA and 5 data sets acquired with contrast enhanced MRA were performed. The luminal diameter, the length of the aneurysm and the detection of dissection was assessed for the reconstructions and the source images. Aneurysms and dissections of the aorta were correctly identified on source images. 2D MPR reconstructions and source images allow for a clear and easy image analysis including cases with high signal intensity or density of surrounding tissue and complex anatomical structures. The diameter and length of pathological findings can be determined correctly wit 2D MPR reconstructions, even when the vessel orientation is not exactly inplane or throughplane in relation to the source images. MIP reconstructions are suitable for contrast enhanced MRA data sets with high C/N ratio and volume rendering reconstructions are suitable for contrast enhanced CTA data sets, where calcifications and bone have also high density. For 3D visualization of large volumes MIP reconstructions are the method of choice for MRA and volume rendering reconstructions for CTA, respectively. In addition, 2D MPR can be necessary to determine the diameter and length of pathological findings.

Adult↗

[Myocardial perfusion at rest and during stress. MR signal characteristics of persistent and reversible myocardial ischemia].

AIM: Performance of combined rest/stress MR perfusion studies and the analysis of qualitative signal intensity parameters in comparison with 99mTc-SestaMIBI SPECT in patients with known coronary artery disease (CAD). METHODS: Sixteen patients with CAD underwent MR myocardial perfusion assessment at rest and after dipyridamole-induced hyperemia. Qualitative parameters (SI increase, SI upslope) of the SI time-curves were evaluated and characteristics of normal, reversible and persistent hypoperfused myocardium as assessed by 99mTc-SestaMIBI SPECT were compared. RESULTS: Compared with the rest values, normal myocardium showed a significant increase of the SI upslope during hyperemia (P < 0.001), whereas persistent (P = 0.07) and reversible (P = 0.15) hypo-perfusions showed only minor changes. SI increase over baseline also showed a significant increase only in normal myocardium (P < 0.001). At rest, reversible ischemic areas showed no significant differences from normal myocardium, whereas during hyperemia SI increase was significantly lower (P = 0.02). CONCLUSIONS: Qualitative SI parameters of a combined rest/stress MR myocardial perfusion study allow to differentiate normal from reversibly or persistently hypoperfused myocardium.

Adult↗

[MR angiography of the supraaortic vessels].

PURPOSE: To compare high resolution contrast-enhanced MR angiography (MRA) and digital subtraction angiography (DSA) in the assessment of supraaortic vessel stenosis. METHODS: 14 patients with suspicion of cerebrovascular disease or upper limb ischemia underwent selective DSA and high resolution contrast enhanced MRA employing a new Panoramic-Array coil. Stenosis assessment in comparison to DSA followed NASCET criteria. Additionally signal-/noise ratios (SNR) were evaluated to assess contrast enhancement. RESULTS: Diagnostic image quality was achieved in all patients. Sensitivity and specificity for assessing high-grade stenosis of the supraaortic vessels were 100% and 96% respectively. In the assessment of high-grade common or internal carotid artery stenosis sensitivity and specificity was 100%. CONCLUSION: High resolution contrast enhanced supraaortic MRA combined with new coil systems allow for a reliable assessment of stenoses along the whole vessel course including the aortic arch. Previous stent procedures limit its use in postinterventional follow-up.

Adult↗

Tumors of the cardiac valves: imaging findings in magnetic resonance imaging, electron beam computed tomography, and echocardiography.

We describe the findings from various cross-sectional imaging modalities in patients with cardiac valve adherent masses. The techniques are discussed, and imaging findings are compared with the results of cardiac surgery. All three patients had neurological symptoms and/or cardiac murmurs. Transthoracic and/or transesophageal echocardiography revealed the cardiac mass in all three. For differentiation of thrombus and cardiac neoplasm magnetic resonance imaging (MRI) was also performed in all three patients and electron-beam computed tomography (EBCT) in two. Fast segmented cine gradient-echo MRI techniques provided mass depiction in all patients, while T1-weighted spin-echo imaging failed in mass detection in one patient. None of the patients showed evidence of valve regurgitation or stenosis in flow sensitive cine MRI. EBCT excluded mass calcifications in both patients and reliably demonstrated the valve attached lesions. Although echocardiography is the modality of choice in evaluating cardiac masses and especially valve attached masses, MRI and EBCT provide additional information about tissue characteristics and allows an excellent overview of the cardiac and paracardiac morphology. Fast segmented cine gradient-echo MRI is especially able to depict even small tumors attached to rapidly moving cardiac valves, and valve competence can be easily assessed within the same examination.

Adult↗

Non-invasive coronary bypass graft imaging after multivessel revascularisation.

Non-invasive imaging techniques for the detection of graft patency after multivessel coronary revascularisation may be useful for follow-up after surgery. Forty consecutive asymptomatic patients (38 men, age 59.9+/-1.3 years) who had undergone coronary bypass surgery with at least three grafts were examined by spiral computed tomography or magnetic resonance angiography 24.9+/-0.3 months after surgery, using conventional angiography as reference. In total, 133 grafts (37 internal mammary artery, 96 venous grafts) were analysed. Spiral computed tomography studies were performed with a subsecond scanner; for magnetic resonance angiography, a three-dimensional contrast-enhanced gradient echo technique with ultrashort echo time during breath holding was used. For spiral computed tomography, sensitivities were 76% (internal mammary artery) and 100% (venous graft). This was compared with 100% (internal mammary artery) and 92% (venous graft) assessed by magnetic resonance angiography (P=ns). The positive predictive values were 100% for internal mammary artery and venous graft (spiral computed tomography) and 100% (internal mammary artery), 92% for venous grafts studied by magnetic resonance angiography (P=ns). Both subsecond spiral computed tomography and contrast-enhanced magnetic resonance angiography are highly accurate and relatively non-invasive approaches of assessing coronary graft patency after multivessel revascularisation and have potential for follow-up assessment in the long term.

Contrast Media↗

Assessment of myocardial perfusion using multisection first-pass MRI and color-coded parameter maps: a comparison to 99mTc Sesta MIBI SPECT and systolic myocardial wall thickening analysis.

The most recently reported magnetic resonance first-pass myocardial perfusion studies were restricted to single slice imaging or a data analysis based on interactively placed regions of interest. This study was designed to investigate a new saturation recovery TurboFLASH sequence for multisection myocardial perfusion imaging and to develop a pixel-based software tool to calculate qualitative perfusion parameters. The findings of perfusion imaging were compared to percent systolic myocardial wall thickening analysis and 99mTc Sesta MIBI SPECT. Six healthy volunteers and twelve patients with proven coronary artery disease (CAD) or chronic myocardial infarction were examined. Diagnostic images were acquired for all volunteers and patients with the multisection saturation recovery TurboFLASH sequence. Perfusion defects could be visualized on parameter maps for signal intensity increase over baseline and signal intensity upslope. Sensitivity and specificity were 76.9% and 97.1% for first-pass perfusion MRI, and respectively 84.6% and 94.3% for CINE imaging. All perfusion defects determined with 99mTc Sesta MIBI SPECT were identified by the combined analysis of myocardial perfusion and wall thickening. The presented software demonstrated a pixel-based analysis of first-pass perfusion studies and simplified image interpretation in a clinical setting. The combination of perfusion and wall motion imaging provided complementary information for the treatment of patients suffering from CAD.

Adult↗

Multislice MR perfusion imaging and regional myocardial function analysis: complimentary findings in chronic myocardial ischemia.

PURPOSE: The purpose of this study is to assess the reliability of multislice MR perfusion imaging in comparison to regional wall function and nuclear medicine and to test different qualitative and quantitative parameters for perfusion assessment. MATERIAL AND METHODS: 15 patients with chronic myocardial ischemia underwent CINE and first-pass perfusion MR imaging. Functional myocardial imaging was performed using a segmented CINE FLASH sequence and systolic myocardial wall thickening was assessed after semiautomated segmentation. MR first-pass perfusion studies were performed using a multislice saturation recovery TurboFLASH sequence. Different parameters were calculated for assessment of hypoperfused segments and results of MR imaging compared to 99mTc-SestaMIBI SPECT. RESULTS: MR perfusion imaging showed a sensitivity of 72% and a specificity of 98%. In combination with MR CINE imaging and wall thickening analysis we calculated a sensitivity of 100% and a specificity of 93%. Qualitative and quantitative perfusion parameter analysis showed significant differences between normal and hypoperfused segments for the signal intensity increase (p < 0.001), the signal intensity upslope (p < 0.001) as well as for the myocardial mean transit time (p < 0.001). CONCLUSION: The combination of systolic wall thickening analysis and myocardial perfusion can markedly improve the sensitivity of MRI in depiction of LV myocardial perfusion abnormalities. For assessment of hypoperfusion, different quantitative and qualitative parameters can be calculated showing significant differences between normal state and hypoperfusion.

Aged↗

[Contrast enhanced MR angiography in the preoperative evaluation of living kidney donors].

PURPOSE: To compare Gadolinium-enhanced MR angiography with conventional DSA in the preoperative evaluation of living kidney donors. MATERIAL AND METHODS: 27 potential living kidney donors were examined with contrast-enhanced MR angiography after conventional angiography. The MR angiograms were evaluated for the number of renal arteries, the presence of early arterial branching and vascular pathologies by two independent readers. The results were compared with those of selective conventional angiography and intraoperative findings. RESULTS: Conventional angiography detected 14 accessory renal arteries. Reader A detected 13 of 14 accessory arteries with no false positive result (sensitivity 93%, specificity 100%). Reader B detected 11 of 14 accessory vessels with one false positive finding (sensitivity 79%, specificity 98%). Early arterial branching was detected by both readers in 9 of 12 vessels with no false positive result (sensitivity 75%, specificity 100%). None of the patients had additional vascular pathology. DISCUSSION: Gadolinium-enhanced MR angiography is a non-invasive alternative to conventional angiography in the preoperative evaluation of living kidney donors. In order to achieve high accuracy in detecting accessory renal arteries and early arterial branching extensive experience with the method and the specific preoperative needs is required. Selective conventional angiography is still superior in detecting very small accessory vessels and early arterial branching.

Adult↗