PubMed Health⌕ Search

Biomedical subjects

B J Wong

Publications and source records attributed to B J Wong.

At least 19 recordsLinked to original sources

Laser-mediated cartilage reshaping with feedback-controlled cryogen spray cooling: biophysical properties and viability.

BACKGROUND AND OBJECTIVE: Recent studies have indicated that chondrocyte viability decreases with prolonged or repeated laser irradiation. To optimize laser-mediated cartilage reshaping, the heating process must be finely controlled. In this study, we use high-power Nd:YAG laser irradiation (lambda = 1.32 microm) combined with cryogen spray cooling (CSC) in an attempt to reshape porcine septal cartilage while enhancing chondrocyte viability. STUDY DESIGN/MATERIALS AND METHODS: Chondrocyte viability was determined after high-power (50 W/cm2) Nd:YAG-mediated cartilage reshaping with and without cryogen spray cooling (CSC) and correlated with dynamic measurements of tissue optical and thermal properties. RESULTS: After 1.5 to 2.0 seconds of laser exposure, characteristic changes in diffuse reflectance (indicating the onset of accelerated stress relaxation) was observed in both laser only and laser with CSC specimens. After 2 seconds of laser exposure, specimens in both groups retained the curved shape for up to 14 days. After one laser exposure, chondrocyte viability was 94.35 +/- 6.1% with CSC and 68.77 +/- 20.1% (P < 0.05) without CSC. After two laser exposures, a similar trend was observed with CSC (70.18 +/- 16.44%) opposed to without CSC (28 +/- 45%; P < 0.05). CONCLUSION: CSC during high-power laser irradiation allows rapid heating while minimizing extreme front surface temperature elevations and axial thermal gradients. Laser irradiation with CSC can be used to effectively reshape cartilage tissue with the additional advantage of increasing chondrocyte viability.

Aerosol Propellants↗

Theramal, mechanical, optical, and morphologic changes in bovine nucleus pulposus induced by Nd:YAG (lambda = 1.32 microm) laser irradiation.

UNLABELLED: BACKGROUND AND OBJECTIVE To examine the biophysical effects of photothermal heating on herniated intervertebral discs during laser decompression surgery. STUDY DESIGN/MATERIALS AND METHODS: Ex vivo bovine nucleus pulposus specimens were irradiated with a Nd: YAG laser (lambda = 1.32 microm, 100 seconds exposure time, 9-31 W/cm(2), 4.8 mm spot diameter), whereas changes in tissue thermal, mechanical, and optical properties were monitored by using, respectively, infrared radiometry, tissue tension measurements, and diffuse reflectance from a HeNe probe laser. Morphologic changes and mass reduction were monitored by recording shape changes on video and weighing specimens before and after laser exposure. RESULTS: At power densities below 20 W/cm(2), evaporation of water and specimen volume reduction (shrinking) were consistently observed on video during irradiation. In contrast, above 20 W/cm(2), vapor bubbles formed within the specimen matrix and subsequently ruptured (releasing heated vapors). When radiometric surface temperature approaches approximately 60 to 70 degrees C (denaturation threshold for tissue), tissue tension begins to increase, which is consistent with observations of specimen length reduction. The onset of this change in tissue tension is also reflected in characteristic alterations in diffuse reflectance. With cessation of laser irradiation, a sustained increase in tissue tension is observed, which is consistent with changes in specimen length and volume. Higher laser power results in a faster heating rate and subsequently an accelerated tension change. Specimen mass reduction increased with irradiance from 19 to 72% of the initial mass for 9--31 W/cm(2), respectively. Irradiated specimens did not return to their original shape after immersion in saline (48 hours) in contrast to air-dried specimens (24 hours), which returned to their original shape and size. CONCLUSION: These observations suggest that photothermal heating results in irreversible matrix alteration causing shape change and volume reduction (observed on video and evidenced by the increase in tissue tension) taking place at approximately 65 degrees C. Inasmuch as high laser power results in vapor bubble formation and specimen tearing, the heating process must be controlled. Diffuse reflectance measurements provide a noncontact, highly sensitive means to monitor dynamically changes in tension of nucleus purposus.

Animals↗

Shape retention in porcine-septal cartilage following Nd:YAG (lambda = 1.32 microm) laser-mediated reshaping.

BACKGROUND AND OBJECTIVE: Photothermal heating of mechanically deformed cartilage accelerates stress relaxation and results in sustained shape change. In this study, shape retention was measured in Nd:YAG laser reshaped porcine septal cartilage. MATERIALS AND METHODS: Specimens were laser reshaped either 4 (Group I) or 28 hours (Group II) following extraction from the crania. Specimens were bent into approximately semicircular shapes and irradiated half way between the endpoints of the semicircle. Resultant bend angle was calculated based on linear measurements. Shape retention was calculated by comparing resultant curvature with pre-irradiation measurements. RESULTS: Mechanical deformation alone resulted in initial bend angles varying from 188 degrees to 229 degrees. Resultant bend angles varied from 84 degrees to 194 degrees corresponding to shape retention varying from 58 to 75%. Non-irradiated cartilage retained less than 46% of the original bend. Shape retention was greater in Group II, compared to Group I. In Group I, no cephalocranial difference in shape retention was observed, though in Group II greater shape retention was observed in rostral specimens. CONCLUSION: While laser heating does significantly reshape cartilage, clinical use of this technology will require "overbending" of the cartilage graft to compensate for this memory effect. The degree of overbending is likely to vary with cartilage type and location.

Animals↗

Laser-assisted hair transplantation: histologic comparison between CO2 and Ho:YAG lasers.

BACKGROUND: Various laser wavelengths and devices have been advocated for use in the creation of recipient channels during hair transplant surgery, including flash-scanned CO2, Ho:YAG (lambda = 2.12 microm), and Er:YAG (lambda = 2.94 microm). OBJECTIVE: To determine the tissue injury caused by flash-scanned CO2 and pulsed Ho:YAG lasers during the creation of hair transplant recipient channels and to assess the efficacy of the Ho:YAG laser. METHODS: Recipient channels were created in vivo in human scalp tissue using both lasers, and were excised and prepared for histologic examination. Optical micrometry of tissue sections was used to assess thermal injury. RESULTS: The Ho:YAG laser created jagged, irregular-shaped channels with larger zones of thermal injury (superficial deepithelialization, thermal necrosis, and thermal damage). In contrast, the CO2 laser produced well-defined cylindrically shaped channels free of cellular debris with minimal epithelial disruption and significantly less lateral thermal injury. CONCLUSION: Given that the Ho:YAG produced larger regions of thermal injury and recipient channels that were unacceptable for graft, the CO2 laser remains the better choice for the creation of recipient channels during hair transplant surgery. However, ongoing research will be necessary to determine the optimal laser wavelength and/or devices for this procedure.

Carbon Dioxide↗

Two-photon excitation laser scanning microscopy of human, porcine, and rabbit nasal septal cartilage.

Two-photon excitation laser scanning microscopy (TPM) was used to image human, porcine, and rabbit nasal septal cartilage. TPM provides optical sections of thick tissue specimens in situ without the use of exogenous dyes or need for tissue fixation. The cartilage tissue was imaged using near-infrared light generated by a mode-locked titanium/sapphire laser that was raster-scanned and coupled to an inverted microscope. Absorption of two photons by endogenous molecules and subsequent fluorescence was filtered to specific spectral bandwidths and detected with photomultiplier tubes. Two-photon stimulated fluorescence was detected with photomultiplier tubes optimized to specific spectral bandwidths. Signal intensity corresponds to the concentration of fluorophores, principally NADH, NADPH, and flavoproteins hence providing a means of redox imaging the cellular metabolic state. Specimens were scanned from the surface to a depth of about 150 microm. Image size was 50 x 50 microm with a diffraction limited pixel size of 0.4 microm. Cell membranes, nuclei, and matrix structures were identified in human, pig, and rabbit tissues. TPM provides a means to study three dimensional chondrocyte structure and matrix organization in situ at substantial depths, and permits longitudinal examination of cultured tissue explants without the need for exogenous dyes, tissue preparation, or fixation.

Animals↗

A large arteriovenous malformation of the external ear in an adult: report of a case and approach to management.

OBJECTIVES/HYPOTHESIS: Arteriovenous malformations involving the external ear are relatively uncommon in adults. Arteriovenous malformations in the head and neck can poses difficult therapeutic challenges. STUDY DESIGN: Case report. METHODS: We report a case of a large arteriovenous malformation in the external ear in a 41-year-old man. RESULTS: Extensive enlargement of the previously latent and asymptomatic arteriovenous malformation was triggered by blunt trauma to the ear. CONCLUSION: We discuss the definition, clinical findings, diagnostic approaches, and therapeutic management of arteriovenous malformations.

Adult↗

Optical and thermal properties of nasal septal cartilage.

BACKGROUNDS AND OBJECTIVES: The aim of the study was to measure the spectral dependence of optical absorption and reduced scattering coefficients and thermal conductivity and diffusivity of porcine nasal septal cartilage. Values of optical and thermal properties determined in this study may aid in determining laser dosimetry and allow selection of an optical source wavelength for noninvasive diagnostics for laser-assisted reshaping of cartilage. MATERIALS AND METHODS: The diffuse reflectance and transmittance of ex vivo porcine nasal septal cartilage were measured in the 400- to 1,400-nm spectral range by using a spectrophotometer. The reflectance and transmittance data were analyzed by using an inverse adding-doubling algorithm to obtain the absorption (mu(a)) and reduced scattering (mu(a)') coefficients. A multichannel thermal probe controller system and infrared imaging radiometer methods were applied to measure the thermal properties of cartilage. The multichannel thermal probe controller system was used as an invasive technique to measure thermal conductivity and diffusivity of cartilage at three temperatures (27, 37, 50 degrees C). An infrared imaging radiometer was used as a noninvasive method to measure the thermal diffusivity of cartilage by using a CO(2) laser source (lambda = 10.6 microm) and an infrared focal plane array (IR-FPA) camera. RESULTS: The optical absorption peaks at 980 nm and 1,180 nm in cartilage were observed and corresponded to known absorption bands of water. The determined reduced scattering coefficient gradually decreased at longer wavelengths. The thermal conductivity values of cartilage measured by using an invasive probe at 27, 37, and 50 degrees C were 4.78, 5.18, and 5.76 mW/cm degrees C, respectively. The corresponding thermal diffusivity values were 1.28, 1.31, and 1.40x 10(-3) cm(2)/sec. Because no statistically significant difference in thermal diffusivity values with increasing temperature is found, the average thermal diffusivity is 1.32 x 10(-3) cm(2)/sec. The numerical estimate for thermal diffusivity obtained from infrared radiometry measurements was 1.38 x 10(-3) cm(2)/sec. CONCLUSION: Values of the spectral dependence of the optical absorption and reduced scattering coefficients, and thermal conductivity and diffusivity of cartilage were measured. The invasive and noninvasive diffusivity measurements were consistent and concluded that the infrared imaging radiometric technique has an advantage to determine thermal properties, because damage to the cartilage sample may be avoided. The measured values of absorption and reduced scattering coefficients can be used for predicting the optical fluence distribution in cartilage and determining optical source wavelengths for the laser-assisted cartilage reshaping studies. The thermal conductivity and diffusivity values can play role in understanding thermal-dependent phenomenon in cartilage during laser irradiation and determining laser dosimetry for the laser-assisted cartilage reshaping studies.

Animals↗

Optical coherence tomography of the rat cochlea.

Optical coherence tomography (OCT) was used to image the internal structure of a rat cochlea (ex vivo). Immediately following sacrifice, the temporal bone of a Sprague-Dawley rat was harvested. Axial OCT cross sectional images (over regions of interest, 1x1 mm-2x8 mm) were obtained with a spatial resolution of 10-15 microm. The osseous borders of the lateral membranous labyrinth overlying the cochlea and the scala vestibuli, media, and tympani, which were well demarcated by the modiolus, Reissner's and the basilar membranes, were clearly identified. OCT can be used to image internal structures in the cochlea without violating the osseous labyrinth using simple surgical exposure of the promontory, and may potentially be used to diagnose inner ear pathology in vivo in both animal and human subjects labyrinth.

Animals↗

Proteoglycan synthesis in porcine nasal cartilage grafts following Nd:YAG (lambda = 1.32 microns) laser-mediated reshaping.

Mechanically deformed morphologic cartilage grafts undergo temperature-dependent stress relaxation during sustained laser irradiation resulting in stable shape changes. In this study, porcine nasal septal cartilage specimens were evaluated for viability by measuring the incorporation of Na2(35)SO4 into proteoglycan (PTG) macromolecules in whole tissue culture following laser-mediated reshaping. Synthesis rates of PTG were determined by scintillation counting lyophilized specimens and normalizing these values by total protein content. Positive controls were established by inducing chondrocyte apoptosis using prolonged exposure to nitric oxide (NO). In chondrocytes, apoptosis induced using NO resulted in significantly lower PTG synthesis rates compared to untreated native specimens. Cartilage specimens were irradiated with light emitted from a Nd:YAG laser (25 W/cm2, lambda = 1.32 microns) while recording simultaneously radiometric surface temperature, internal stress and back-scattered light intensity from a probe laser. Each specimen received one, two or three sequential laser exposures. The duration of each exposure was determined from real-time measurements of characteristic changes in back-scattered light intensity that correlate with accelerated stress relaxation. A 5 min time interval between each laser exposures allowed the cartilage specimen to return to thermal equilibrium. Average PTG synthesis rates decreased with successive laser exposures, though these were always higher than baseline rates established for NO-treated tissues, suggesting that laser-mediated cartilage reshaping acutely does not eliminate the entire population of viable chondrocytes. The reduction in PTG synthesis is correlated with the time-temperature-dependent heating profile created during laser irradiation, supporting our hypothesis that careful monitoring of laser dosimetry is required to ensure chondrocyte viability.

Animals↗

Prevalence of external auditory canal exostoses in surfers.

OBJECTIVE: To determine (1) the prevalence of external auditory exostoses in a population of surfers and (2) the relationship between the length of time spent surfing and the prevalence, severity, and location of the exostoses. DESIGN: Cross-sectional epidemiological study. SETTING: General community. PATIENTS: Three hundred seven avid surfers (93.5% males and 6.5% females; age distributions: 11.2% were < or =20, 67.9% were 21 to 40, 17.5% were 41 to 50, and 3.3% were >50 years). MAIN OUTCOME MEASURES: Questionnaires focusing on surfing habits (number of years, geographic region, and number of days per year of surfing) were correlated with otoscopic findings. A simple grading system was devised, based on the degree of external auditory canal stenosis. Grades of normal, mild, moderate, and severe corresponded to 100%, 99% to 66%, 65% to 33%, and less than 33% effective patent surface area, respectively. RESULTS: There was a 73.5% overall prevalence of external auditory exostoses and a 19.2% overall prevalence of osteomas in the group studied. Of 441 ears with exostoses, 54.2% were mild, 23.6% were moderate, and 22.2% were severe. Of individuals who had surfed for 10 years or less, 44.7% had normal ear canals and only 6% had severely obstructed auditory canals. In comparison, in the group that had surfed for longer than 20 years, only 9.1% had normal auditory canals and 16.2% were severely affected. Of surfers with no exostoses, 61.1% had surfed for 10 years or less. In contrast, of surfers with severe exostoses, 82.4% had surfed for more than 10 years. Finally, the lesions seemed to affect all external auditory canal quadrants equally. CONCLUSION: A positive association exists between the amount of time individuals spend surfing and the presence and severity of exostoses of the external auditory canal.

Adult↗

XeCl laser surgery of the vocal cords: a histologic comparison with CO2 laser in a porcine model.

Fresh cadaveric pig larynxes were ablated with a CO2 (lambda = 10.6 microm) and a XeCl excimer (lambda = 308 nm) laser. Histologic comparison of the ablation craters created by the two lasers was performed, and ablation crater depth and marginal tissue damage were measured. Crater depth for both laser treatments is correlated with energy deposition and exposure time. The CO2 laser creates three times more nonspecific, marginal tissue damage than the XeCl laser at the ranges of total energy and exposure times used. This study demonstrates the potential of the XeCl laser as an alternative to the CO2 laser in microlaryngeal surgery.

Animals↗

Thermal imaging of the temporal bone in CO2 laser surgery: an experimental model.

The unique properties of lasers create an enormous potential for specific treatment of chronic ear disease. Despite the widespread acceptance and use of the laser, however, a complete understanding of the time- and space-dependent temperature distribution in otic capsule bone immediately after pulsed laser exposure has not been elucidated. Using a liquid nitrogen-cooled mercury-cadmium telluride infrared detector, the temperature distribution in human cadaveric otic capsule bone was determined immediately after pulsed (100 msec) carbon dioxide laser exposure (0.3 to 4.0 W; 200 microm spot diameter). The time- and space-dependent temperature increases and thermal diffusion were determined as a function of the laser power density and were found to vary linearly.

Carbon Dioxide↗

Surface temperature distributions in carbon dioxide, argon, and KTP (Nd:YAG) laser ablated otic capsule and calvarial bone.

HYPOTHESIS: The spatial and temporal surface temperature distribution was measured after laser irradiation in fresh porcine otic capsule and calvarial bone tissue using an HgCdTe (mercury-cadmium-tellurium) infrared camera. BACKGROUND: Carbon dioxide (CO2) (lambda = 10.6 mm), argon (lambda = 514 nm), and Potassium-Titanyl-Phosphate Neodynium: Yttrium-Aluminum-Garnet (KTP[Nd:YAG]) (lambda = 532 nm) lasers are used for stapes surgery and in the treatment of chronic ear disease. Despite extensive clinical use, little is known about the thermal perturbations in otic capsule calcified tissues and what are safe energy parameters for laser use. METHODS: A microspot manipulator, lens, and microfiber were used for continuous wave (CW) and super-pulse (SP) CO2, argon, and KTP(Nd:YAG) lasers, respectively. Peak temperatures after ablation were measured simultaneously along with the full-width--half-maximum of the thermal disturbance and fitted to a Gaussian distribution. The cooling time for the hot spot to return to ambient temperature also was recorded. RESULTS: Temperature changes with CW CO2 irradiation were markedly elevated relative to SP mode and also required longer to cool. The KTP and argon-treated bone were irradiated in the presence and absence of an initiator (black ink): minimal surface temperature elevation was recorded in the absence of an initiator. Further, no surface modification was observed. In contrast, the addition of an initiator resulted in marked temperature elevations and significant surface carbonization with these two visible wavelength lasers. Cooling times varied from 10-40 seconds. No consistent relation to the measured thermal values and tissue microarchitecture was observed. CONCLUSIONS: The measured cooling times and Gaussian distribution of surface temperatures serve as empiric guidelines for minimizing thermal injury to critical structures during laser surgery in the middle ear.

Animals↗

Identification of photoacoustic transients during pulsed laser ablation of the human temporal bone: an experimental model.

Laser ablation of hard tissues during neurotologic operations has been accomplished with continuous-wave (CW) lasers in the visible and midinfrared spectrum. The mechanism of ablation at these wavelengths is secondary to photothermal-induced tissue destruction. As a result, significant thermal damage to surrounding tissue may occur. Pulsed ultraviolet (UV) lasers have been suggested as an alternative to the argon, KTP-532, and CO2 lasers currently used in clinical practice. The pulse length of Excimer lasers are considerably shorter than the thermal diffusion time of bone tissue, and as a consequence thermal injury is minimal. This makes pulsed lasers an attractive tool for tissue ablation in the ear: in essence a "cold knife." However, the short pulse width of Excimer lasers (typically 10-150 ns) can create large thermoelastic stresses in the ablation specimen. This study identifies the presence of these photoacoustic waves during the Excimer laser treatment of the cadaveric human temporal bone. A XeCl (lambda = 308 nm, tau p = 12 ns) excimer laser was used to ablate hard tissue surrounding the oval window and facial ridge with energies of 75, 45, 25, and 12 mJ/pulse. Spot size was estimated to be 0.5 mm2. Custom high-frequency polyvinyldifluoride (PVDF) piezoelectric film transducers were fabricated and attached to the promontory, round window niche, and facial ridges. The signals were amplified using a low-noise preamplifier and recorded on a digitizing oscilloscope. Photoacoustic waves were clearly identified. Notably, large acoustic waves were measured on the promontory and on both sides of the facial ridge. The implications and clinical relevance of these findings is discussed and compared to findings obtained from a model system.

Acoustics↗

Effect of salmeterol compared with beclomethasone on allergen-induced asthmatic and inflammatory responses.

Salmeterol is a selective long-acting beta 2-agonist bronchodilator considered to have added anti-inflammatory effects, but this is controversial. We investigated the effects of a single dose of salmeterol, 100 micrograms, on the physiological and inflammatory responses to inhaled allergen and compared these with the effects of a single dose of beclomethasone, 500 micrograms, and of placebo. Eight atopic adults with mild stable asthma, treated only with inhaled short-acting beta 2-agonist when needed, attended the laboratory sequentially for screening tests, two single-blind control inhalation tests preceded 30 min by placebo or salmeterol and three allergen inhalation tests preceded by placebo, salmeterol or beclomethasone double-blind in random order. Airway responsiveness to methacholine (assessed as the provocative concentration of methacholine producing 20% fall in forced expiratory volume in one second (PC20)), induced sputum eosinophils, blood eosinophils and serum eosinophil cationic protein (ECP) were examined before and 7-48 h after treatment. The statistical power to detect twofold changes in blood and sputum parameters was > or = 90%. Salmeterol inhaled before allergen challenge completely prevented the early asthmatic response, late asthmatic response and fall in methacholine PC20 at 24 h, and produced additional bronchodilatation. These effects were similar to those obtained by the inhalation of a single dose of salmeterol before the control inhalation test, and significantly better than those observed after a single dose of beclomethasone inhaled before the allergen test. Beclomethasone had no effect on the early asthmatic response or on the fall in methacholine PC20 at 24 h but partially inhibited the late asthmatic response. Neither salmeterol nor beclomethasone had any significant effect on sputum or blood inflammatory changes 7-48 h after allergen inhalation. In conclusion, whilst salmeterol had no demonstrable anti-inflammatory action in sputum after allergen challenge in asthma, neither did a single dose of the positive anti-inflammatory control, beclomethasone. The latter result excludes a more positive judgement on the possible anti-inflammatory action of salmeterol. However, the results do indicate that potent functional effects of a single dose of salmeterol can mask the airway inflammatory cell influx caused by inhaled allergen.

Administration, Inhalation↗