Oral anticoagulation self-management and management by a specialist anticoagulation clinic: a randomised cross-over comparison.

BACKGROUND: Vitamin K antagonist treatment is effective for prevention and treatment of thromboembolic events but frequent laboratory control and dose-adjustment are essential. Small portable devices have enabled patient self-monitoring of anticoagulation and self-adjustment of the dose. We compared this self-management of oral anticoagulant therapy with conventional management by a specialist anticoagulation clinic in a randomised cross-over study. METHODS: 50 patients on long-term oral anticoagulant treatment were included in a randomised controlled crossover study. Patients were self-managed or were managed by the anticoagulation clinic for a period of 3 months. After this period the alternative strategy was followed for each patient. Prothrombin time (expressed as international normalised ratio [INR]) were measured at intervals of 1-2 weeks in both periods without knowledge of type of management. The primary endpoint was the number of measurements within the therapeutic range (therapeutic target value +/-50.5 INR units). FINDINGS: There was no significant difference in the overall quality of control of anticoagulation between the two study periods. Patients were for 55% and for 49% of the treatment period within a range of +/-0.5 from the therapeutic target INR during self-management and anticoagulation clinic management, respectively (p=0.06). The proportion of patients who spent most time in the therapeutic target range was larger during self-management than during anticoagulation clinic-guided management. The odds ratio for a better control of anticoagulation (defined as the period of time in the therapeutic target range) during self-management compared with anticoagulation clinic-guided management was 4.6 (95% CI 2.1-10.2). A patient-satisfaction assessment showed superiority of self-management over conventional care. INTERPRETATION: Self-management of INR in the population in this study is feasible and appears to result in control of anticoagulation that is at least equivalent to management by a specialist anticoagulation clinic. It is also better appreciated by patients. Larger studies are required to assess the effect of this novel management strategy on the incidence of thromboembolic or bleeding complications.

Administration, Oral↗

Pharmacological strategies to decrease excessive blood loss in cardiac surgery: a meta-analysis of clinically relevant endpoints.

BACKGROUND: Excessive bleeding may complicate cardiac surgery, and is associated with increased morbidity and mortality. Pharmacological strategies to decrease perioperative bleeding have been investigated in a large number of controlled trials, most of which have shown a decrease in blood loss. However, most studies lacked sufficient power to detect a beneficial effect on clinically more relevant outcomes. We did a meta-analysis of all randomised, controlled trials of the three most frequently used pharmacological strategies to decrease perioperative blood loss (aprotinin, lysine analogues [aminocaproic acid and tranexamic acid], and desmopressin). METHODS: Studies were included if they reported at least one clinically relevant outcome (mortality, rethoracotomy, proportion of patients receiving a transfusion, or perioperative myocardial infarction) in addition to perioperative blood loss. In addition, a separate meta-analysis was done for studies concerning complicated cardiac surgery. FINDINGS: We identified 72 trials (8409 patients) that met the inclusion criteria. Treatment with aprotinin decreased mortality almost two-fold (odds ratio 0.55 [95% CI 0.34-0.90]) compared with placebo. Treatment with aprotinin and with lysine analogues decreased the frequency of surgical re-exploration (0.37 [0.25-0.55], and 0.44 [0.22-0.90], respectively). These two treatments also significantly decreased the proportion of patients receiving any allogeneic blood transfusion. By contrast, the use of desmopressin resulted in a small decrease in perioperative blood loss, but was not associated with a beneficial effect on other clinical outcomes. Aprotinin and lysine analogues did not increase the risk of perioperative myocardial infarction; however, desmopressin was associated with a 2.4-fold increase in the risk of this complication. Studies in patients undergoing complicated cardiac surgery showed similar results. INTERPRETATION: Pharmacological strategies that decrease perioperative blood loss in cardiac surgery, in particular aprotinin and lysine analogues, also decrease mortality, the need for rethoracotomy, and the proportion of patients receiving a blood transfusion.

Aminocaproates↗

Biocompatibility of three different membrane oxygenators: effects on complement, neutrophil and monocyte activation.

The inflammatory reaction of extracorporeal circuits can be assessed by measuring complement activation and the release of activation markers of leucocytes. The purpose of this study was to compare three commercially available membrane oxygenators with respect to complement (C3a), granulocyte (lactoferrin) and monocyte (interleukin-6, IL-6) activation. Thirty patients undergoing cardiac surgery were randomly assigned to undergo cardiopulmonary bypass (CPB) with one of the following oxygenators: a polypropylene hollow-fibre membrane (group 1; 2.2 m2), a polypropylene flat-sheet membrane (group 2; 3.1 m2) or a silicone envelope membrane (group 3, 3.5 m2). In all patients, a significant increase in C3a in plasma occurred during CPB with peak levels after the administration of protamine sulphate. In blood samples taken before aortic crossclamp release, at the end of CPB, and 20 min after protamine administration C3a was significantly lower in group 1 than in the other two groups. Lactoferrin increased significantly during CPB in all patients without a significant difference between the groups. IL-6 did not increase during CPB, but raised significantly after 4 h in the intensive care unit in all groups. Moreover, IL-6 was significant lower in group 1 than group 3. The data suggest that the polypropylene hollow-fibre membrane oxygenator, i.e. the oxygenator with the smallest surface area, is more biocompatible than the other types, probably because of a smaller contact surface area.