PubMed Health⌕ Search

Biomedical subjects

B Jing

Publications and source records attributed to B Jing.

13 recordsLinked to original sources

Medial axis reformation: a new visualization method for CT angiography.

RATIONALE AND OBJECTIVES: The authors performed this study to evaluate a new method (medial axis reformation [MAR]) for visualizing three-dimensional vascular data at electron-beam computed tomographic (CT) angiography. MATERIALS AND METHODS: MAR was performed automatically with a personal computer-based workstation. After the region of interest was edited, voxels were divided into groups according to their path lengths. Centroids of groups were connected to form the medial axis. Then, the medial axis was refined with multiscale medial response. Bifurcations were also detected and refined. Finally, curved sections were generated through the branches and laid out onto a single image by using a splitting method. The authors performed MAR during electron-beam CT angiography of coronary arteries, common carotid arteries, and iliac arteries. RESULTS: MAR displayed curved sections of branched vessels on one image, cut through the axis of vessels to show the vessel diameter objectively, and allowed the viewing direction to be altered arbitrarily. CONCLUSION: Results of preliminary applications demonstrate that MAR is a valuable new visualization method for CT angiography.

Adult↗

Evaluation of coronary artery bypass graft patency using three-dimensional reconstruction and flow study of electron beam tomography.

OBJECTIVE: To establish and evaluate two protocols for the noninvasive visualization and assessment of coronary artery bypass graft (CABG) patency on electron beam tomography (EBT). METHODS: Two hundred and fourteen consecutive patients who underwent coronary artery bypass graft surgery were scanned using both EBT angiography with 3-dimensional reconstruction and EBT flow study with time-density-curve analysis. RESULTS: There were 589 CABGs evaluated in this study (10 grafts were excluded because of artifacts). Among them, 133 (98.5%) of 135 arterial grafts were patent, and 345 (77.7%) of 444 saphenous-vein grafts were patent. Within 5 years or between 5 and 10 years after operation, arterial graft patency exceeded venous graft patency (P < 0.001). Three-dimensional EBT angiography achieved higher sensitivity, specificity and accuracy (97.7%, 94.1% and 96.7%, respectively) than did EBT flow study (88.4%, 82.4% and 85.2%, respectively) for evaluating occlusion or patency of CABG. The intra-graft flow of patent arterial and venous grafts were 4.9 +/- 2.2 ml.min-1.g-1 and 6.9 +/- 2.8 ml.min-1.g-1, respectively (P < 0.001). CONCLUSION: The combination of EBT three-dimensional reconstruction and flow study can be more effective in the assessment of CABG anatomy and quantification of patent CABG blood flow.

Adult↗

Evaluation of electron beam tomographic coronary arteriography with three-dimensional reconstruction in healthy subjects.

In this study, the authors evaluated the performance characteristics of contrast-enhanced electron-beam tomography (EBT) with three-dimensional reconstruction in defining the coronary artery lumen in healthy subjects. Thirty patients with normal coronary angiograms by selective coronary arteriography (SCA) underwent contrast-enhanced EBT examination. Measured parameters included degree of luminal enhancement, intravascular contrast-to-noise ratio (CNR), and diameter and length of visualized lumen. Ventricular cavity, aortic blood pool, and coronary artery attenuation were found to be significantly different before and after intravenous injection of contrast material (p < 0.001). CNR decreased from proximal to distal segments within each vessel (p < 0.001), with a peak of 11.2 +/- 2.3 occurring in the proximal left anterior descending coronary artery (LAD) to a low of 4.8 +/- 2.0 in the distal left circumflex (LCX). Luminal diameters visualized by EBT had no significant difference with that of SCA (p > 0.05). Therefore, EBT angiography with three-dimensional reconstruction allows for noninvasive coronary arteriography revealing long segments of the major coronary arteries in normal subjects.

Adult↗

Detection and analysis of intracoronary artery stent after PTCA using contrast-enhanced three-dimensional electron beam tomography.

We evaluated several three-dimensional methods of contrast-enhanced electron beam tomography (EBT) for evaluation of intracoronary stent characteristics after percutaneous transluminal coronary angioplasty (PTCA). Twenty-six patients who had undergone PTCA and stenting (31 stents) were investigated by using contrast-enhanced, electrocardiographically (ECG) triggered EBT scanning. EBT results were compared with conventional selective coronary arteriography (SCA). Overall, 27 intracoronary stents had been identified on EBT images (87.1%), while 4 stents could not be evaluated because of impaired image quality. EBT correctly identified the only case in which there was a residual stenosis at the distal portion of the stent. As compared with SCA results, EBT showed an over-estimation of intracoronary stent diameter (p < 0.001) and accurate measurement on the visualized length of the stents (p > 0.05). Fifty Hu, 100 Hu and 150 Hu were used as the observed window levels on three-dimensional (3-D) images; the accuracy for stent assessment increased with ascending window levels. EBT can reliably characterize coronary artery stents and may become a useful non-invasiveive method for patency evaluation of stented coronary segments after PTCA.

Adult↗

[Effect of rhubarb on oxygen radicals leakage from mitochondria of intestinal mucosa in burned rats].

OBJECTIVE: To investigate the effects of rhubarb on oxygen radicals leakage from the mitochondria of intestinal mucosa in burned rats. METHODS: The activity of cytochrome oxidase and superoxide dismutase (SOD) in mitochondria isolated from intestinal mucosa of burn model of rats was used to evaluate the oxygen radicals leakage from the mitochondria. And the SOD and malondialdehyde (MDA) levels in plasma, liver, intestinal mucosa and its mitochondria were also determined. RESULTS: After burn injury, the activity of cytochrome oxidase in intestinal mucosa decreased as the time elapses, rhubarb could improve it obviously. Furthermore, rhubarb could reduce the massive consumption of SOD and production of MDA obviously increased in plasma, liver, intestinal mucosa and its mitochondria after burning. CONCLUSION: Rhubarb could enhance the activity of cytochrome oxidase and SOD in small intestine mucosal epithelia in burned rats, thus the oxygen radicals leakage from the mitochondria to be reduced.

Animals↗

Electron-beam CT angiography with three-dimensional reconstruction in the evaluation of coronary artery bypass grafts.

RATIONALE AND OBJECTIVES: The authors evaluated the use of electron-beam computed tomographic (CT) angiography and three-dimensional (3D) reconstruction for evaluation of coronary artery bypass grafts (CABGs). MATERIALS AND METHODS: Sixty patients (53 men and seven women; mean age, 56 years +/- 8) with 152 CABGs (29 internal mammary artery and 123 saphenous vein grafts) underwent electron-beam CT with 3D reconstruction. The time from bypass surgery to CT scanning was 7 days to 120 months (mean, 17 months +/- 28). Enhanced single-section and flow mode studies were performed in all cases. The results were correlated with CABG operation records, and patency was determined with time-attenuation curves. RESULTS: All patients were successfully examined. On the basis of time-attenuation curve criteria, 124 (81.6%) of 152 grafts were patent. The patency rate for the internal mammary artery subgroup was 93% (27 of 29 grafts); for the saphenous vein graft subgroup, 78.9% (97 of 123 grafts). CONCLUSION: Used in contrast-enhanced, single-section mode and flow studies with time-attenuation curves, electron-beam CT angiography with 3D reconstruction can provide quantitative data for evaluation of CABG patency.

Adult↗

Three-dimensional reconstruction of electron beam computed tomography angiography for evaluating coronary artery bypass grafts.

OBJECTIVES: To probe into electron beam computed tomography (EBCT) angiography and 3-D reconstruction of coronary artery bypass grafts (CABG) and to evaluate the clinical application of EBCT angiography and 3-D reconstruction of CABG. METHODS: EBCT angiography with 3-D reconstruction was achieved in 150 patients (142 men and 8 women, mean age, 57 +/- 8 years) with 399 grafts including 100 internal mammary artery grafts (IMG), 296 saphenous vein grafts(SVG) and 3 radial artery grafts (RAG) respectively. The time from bypass surgery to EBCT scanning ranged from 7 days to 120 months, averaging 15 +/- 28 months. Enhanced single slice mode (SSM) and flow studies were performed in all patients. The results of 3-D reconstruction of CABG were compared with bypass operation records and with coronary arteriograms (7 patients). RESULTS: 150 patients underwent successfully EBCT angiography and CABG 3-D reconstruction. According to 3-D reconstruction of the coronary bypass grafts with flow studies, 318 of 399 coronary bypass grafts were patent including IMG patency in 87/100 (87%), SVG in 228/296 (77%) and RAG in 3/3 (100/100). The overall patent rate was 79.7%. In 7 patients with 12 coronary bypass grafts, EBCT studies showed graft patency (7 grafts) and occlusion (5), which were confirmed by conventional graft angiography. CONCLUSIONS: EBCT angiography with 3-D reconstruction is effective in providing the entire anatomic structure of coronary bypass grafts and evaluating coronary bypass graft patency. EBCT flow study can provide quantitative data for evaluating coronary bypass graft patency and for supplemental diagnosis of CABG 3-D reconstruction. EBCT angiography is a noninvasive technique that could replace conventional coronary arteriography for follow-up survey of coronary bypass surgery in future.

Adult↗

[Analysis of nuclear DNA gene types of Leishmania isolates from hilly and plain foci of China].

AIM: To analyse the nuclear DNA (nDNA) polymorphism of Leishmania isolates from hilly and plain foci of China. METHODS: nDNA were analysed by endonuclease digestion, Southern blotting and chromosomal localization. Probes were labeled with digoxigenin. RESULTS: Using gp63 gene probe, similar hybridization bands were found to be existed between nDNAs of Leishmania donovani Jiangsu human isolate and L. d. Jeddah, also between nDNAs of L. d. Sichuan human isolate and L. infantum. Using beta-tubulin gene probe, there were two similar hybridization bands existed between nDNAs of L. d. Jiangsu human isolate and L. d. Jeddah, and three similar hybridization bands existed between nDNAs of L. d. Sichuan canine isolate and L. d. Gansu canine isolate, and two similar hybridization bands existed between nDNA of L. d. Sichuan canine isolate and L. d. Wenchuan human isolate. CONCLUSION: Homology exists between L. d. Jiangsu human isolate and L. d. Jeddah from plain foci, between L. d. Sichuan human isolate from hilly foci and L. infantum, between L. d. Sichuan canine isolate and L. d. Gansu canine isolate from hilly foci. Homology as well as differences exist between L. d. Sichuan canine isolate and L. d. Wenchuan human isolate. Heterogeneity exists between isolates from hilly foci and plain foci.

Animals↗

[Construction of genomic library of L. interrogans serovar lai using lambda gt11 as the vector and a study of recombiant plasmid pDL121].

A genomic library of L. interrogans serovar lai strain 017 has been constructed using lambda gt11 as the vector. DNA was partially digested by two blunt-end restriction enzymes, then methylated with EcoR I methylase; after EcoR I linker was added to the DNA, the linker-ended DNA was ligated to the dephosphorylated EcoR I digested lambda gt11 arms. The recombined DNA was packaged in vitro, and used to transduct E. coli Y1090 for amplification. There were 2.1 x 10(6) recombinant bacteriophages as recognized by their ability to form white plaques plated on Lac host in the presence of both IPTG and X-Ga1. A positive clone, designated lambda DL12, was screened with a rabbit anti-serum against L. interrogans serovar lai from the genomic library. The DNA from lambda DL12 was subcloned into plasmid pUC18. A recombinant (designated as pDL121) was obtained. SDS-PAGE analysis indicated that a 23 kd was expressed in E. coli JM 103 harboring pDL121. Western blotting analysis showed that a specific protein band molecular weight of 23 kd could be recognized by the rabbit antiserum against L. interrogans serovar lai strain 017.

Cloning, Molecular↗

[Preliminary study on expression of Leishmania donovani antigen gene in E. coli].

We constructed previously the expressing library of Leishmania donovani genomic DNA with lambda gt11 as vector. In this paper, 2 x 10(4) phages were plated on E. coli Y1090r-, and screened with a rabbit antiserum prepared by immunization with Leishmania donovani promastigotes. Bound antibodies were detected using alkaline phosphatase labeled anti-rabbit antibodies. A positive expressing clone was detected and transferred into E. coli Y1098r- to prepare lysate, a 39 kDa polypeptide in E. coli Y1089r-lysate was recognized by anti-Leishmania donovani serum. The result indicated that the 39 kDa polypeptide which was not fused with the major portion of beta-galactosidase existed disconnectedly. This finding remained to be further studied.

Animals↗

Mutations in the V2 vasopressin receptor gene are associated with X-linked nephrogenic diabetes insipidus.

X-linked nephrogenic diabetes insipidus (NDI) is a rare disorder in which the kidney is insensitive to the antidiuretic hormone, vasopressin. It has been proposed that the kidney-specific V2 vasopressin receptor, a G protein-coupled receptor, is defective in this disorder as both the disease and the receptor map to Xq28. We report six unique mutations in the V2 receptor gene of five unrelated NDI patients, with one patient having two mutations. The most severely affected patient has a nonsense mutation which would terminate the protein in transmembrane domain III. Other mutations include three missense mutations, a frameshift and one small in-frame deletion. These results represent one of the first examples of recessive mutations affecting a G protein-coupled receptor.

Amino Acid Sequence↗

Transperitoneal percutaneous retroperitoneal lymph node aspiration biopsy.

Percutaneous aspiration biopsies of opacified retroperitoneal lymph nodes, and retroperitoneal, intraperitoneal and paraspinal masses were successfully accomplished in 14 of 17 patients. A 23-guage needle was utilized for the procedure which is performed under fluoroscopic guidance. Metastatic carcinoma, sarcoma and melanoma were readily identified by aspiration biopsy while the diagnosis of lymphoma, especially as to type, was more difficult. No significant complications have resulted from the passage of the needle through the peritoneal cavity.

Adolescent↗