PubMed Health⌕ Search

Biomedical subjects

B K Milthorpe

Publications and source records attributed to B K Milthorpe.

At least 37 records · Page 2Linked to original sources

An experimental model of affinity cell separation.

Cell affinity separations are based on the selective attachment of cell phenotype using antibody or lectins specific for cell surface markers. The major physicochemical factors which influence ligand-mediated cell adhesion dynamics and the efficiency of cell affinity separation have been examined. Uniform cell detachment forces were generated with a parallel-plate flow cell (plate separation 100 microns, surface area 3 cm2). Hydrodynamic shear stress was used to measure cell adhesion strength and to separate cells on the basis of surface affinity. Human cell lines grown in tissue culture were separated on a flat derivatised glass immunoadsorbent which formed the floor of the flow chamber. Flow-cell residence time, detachment shear stress, temperature, and ligand density were shown to influence cell attachment probability. An understanding of the physical basis of ligand-mediated cell adhesion provided a rationale for optimisation of affinity cell separation. At room temperature attachment of positive cells was rapid (< 2 min) and adhesion strength was directly related to immunoadsorbent ligand density. Purity and recovery of enriched fractions were dependent on the separation shear stress and could be optimised using this parameter. Enrichment factors were greater than 100-fold, with at least 90% of positive cells recovered in enriched fractions. Enrichment purity and yields did not decline at higher loading densities (10(5) cells/cm2). Selective immunoadsorbent surface chemistry is a prerequisite for efficient affinity cell separation. Purity and recovery may be optimised by fractionating enriched and depleted cell populations with uniform fluid shear stress.

Antibody Affinity↗

Measurement of microtomy-induced section distortion and its correction for 3-dimensional histological reconstructions.

The presence of microtomy induced distortion in paraffin sections is a significant hindrance to the accurate alignment of sections for three-dimensional reconstructive techniques. Measurements of section distortion in various rat tissues demonstrated distortions to be present in all sections, with over 85% of such distortions being manifest as expansions when compared to the original distances between a series of eight drilled fiducial marks. Mean percentage dimensional changes in the direction of the cutting stroke and at right angles to this direction were -0.5 +/- 1.5% and 3.7 +/- 1.2% for liver, 7.6 +/- 2.4% and 9.1 +/- 1.2% for kidney, 6.6 +/- 2.3% and 10.5 +/- 1.4% for lung, and 20.3 +/- 6.6% and 8.9 +/- 5.9% for skeletal muscle. Individual sections invariably displayed measurable distortions, with only skeletal muscle showing any consistent pattern, in the form of "barrel" distortion at right angles to the cutting stroke. In addition a method of distortion correction and simultaneous image alignment is presented as a means of section alignment with full distortion correction capability. This method uses a quadratic polynomial transform in a non-linear "unwarping" algorithm, to correct for the rotational and translational misalignment as well as for microtomy and camera aspect ratio distortions. Application of this method to a sequence of 46 serial sections demonstrated an alignment accuracy to within 2.6 +/- 0.8 pixels.

Animals↗

Xenografts for tendon and ligament repair.

Collagenous materials, usually of bovine or equine origin, have been popular starting points for the development of xenograft prostheses for tendon and ligament repair. Xenografts are highly attractive as they carry small risk of infectious disease, do not compromise the patient's remaining tissues and may have the 'correct' structure as the component being replaced. Animal studies, on dog, rabbit and chicken, have shown tremendous potential for this use of xenograft material as a tendon replacement. Why, therefore, have xenografts been almost universally a total failure in clinical application? The reasons would appear to be two-fold: the animal models have not been appropriate to the intended clinical use and the cross-linking of xenograft materials has not been optimized. Our work on xenograft, heterograft and autograft tissues indicates that both aspects deserve more attention. Quantitative histology indicates that the extent and type of response to xenograft materials differs widely with degree of cross-linking (glutaraldehyde). Attention must also be given to the join of the graft to the host. For both tendon and ligament the join is a site of particular fragility. Even with adequate strength in the mid-substance, tendon and ligament grafts can, and do, fail at the join. We have investigated a variety of mechanisms for joining tendon to tendon and ligaments to bone. The failures of these methods present some insight into the biology of the repair process involved and into how failure may be avoided in future.

Animals↗

Phosphorus studies in pigs. 1. Available phosphorus requirements of grower/finisher pigs.

Two experiments were conducted to determine the available P requirements of grower and grower/finisher pigs and to define the conditions for conducting a growth assay for P availability. In the first experiment, diets with four levels of calculated available P (1-4 g/kg) and four Ca:available P ratios (1.7-2.9) were used to determine the available P requirements of grower pigs. The diets were formulated by substituting the required amounts of limestone and sodium tripolyphosphate for sugar in a soya-bean meal and sugar-based diet. In addition to measuring growth responses, a range of bones were examined to determine the most suitable criteria for assessing the response to available P. There was a small quadratic response of feed intake and growth rate of the pigs to level of available P, with maximum responses occurring to approximately 3 g available P/kg (P < 0.05). There were linear depressing effects of increasing Ca:available P ratios on carcass gain and feed conversion ratio (P < 0.01) but most of these effects occurred when the ratio exceeded 2.5:1. All bone variables examined increased linearly (P < 0.05) or curvilinearly (P < 0.01) with increasing available P concentration. In general, these variables were not affected by the Ca:available P ratio. The results of the growth responses and bone development indicate that the grower pig requires approximately 3 g available P/kg. However, for availability assays, where linearity of response is needed, the dietary concentration of available P should be a maximum of approximately 2 g/kg. In the second experiment four levels of calculated available P (1-4 g/kg) with a Ca:available P ratio of 2.5:1 were used to determine the available P requirements of grower/finisher pigs from 20 to 90 kg live weight. At 50 kg live weight the dietary available P concentration for half the pigs fed at 2, 3 and 4 g available P/kg was reduced to 1, 2 and 3 g/kg respectively. The pigs were fed ad lib, and growth performance, bone characteristics, P retention and ash concentration in the empty body were taken as response criteria to assess P adequacy. Among the variables tested, the ash concentration in the radius/ulna bone and P and ash concentrations in the empty body appeared to be more responsive than other variables to the changes in dietary P levels.(ABSTRACT TRUNCATED AT 400 WORDS)

Animal Nutritional Physiological Phenomena↗

The effect of gamma irradiation on a xenograft tendon bioprosthesis.

Radiation sterilisation of xenograft prostheses has been shown to cause damage to the material. Such damage has been imputed to affect the mechanical and biological properties and may contribute to long-term failure. This study has examined the effect of 25 kGy (2.5 Mrad) of gamma radiation on the mechanical and physicochemical properties and the biological function of a xenograft tendon bioprosthesis derived from glutaraldehyde cross-linked kangaroo tail tendon. The ultimate tensile stress of nonirradiated glutaraldehyde cross-linked tendon was greater than that of fresh frozen tendon, but irradiated cross-linked tendon did not differ. Irradiation did not alter the response to prolonged collagenase exposure. There was a decrease in overall apparent cross-link density (as determined by thermal denaturation temperature). After 12 months implantation, there was a slightly more active cellular response around irradiated tendon and the very peripheral fibres were infiltrated, but the mechanical properties of the retrieved implants were the same for irradiated and nonirradiated material. Gamma irradiation would appear to be a satisfactory method of sterilisation for glutaraldehyde cross-linked tendon materials. However, as damage to the cross-linked structure was detected in this study, it may not be appropriate in other applications.

Animals↗

Treated xenografts as gliding tendon prostheses in an ovine model.

A model for testing the properties of gliding tendon grafts has been developed that allows anastomoses to be evaluated separately from the mid-portion of the graft. In addition, two different graft materials may be implanted in one sheep foreleg whilst maintaining control (not operated) tendons in both the operated leg and contralateral foreleg. The model has been used to evaluate the response of xenografts made from chemically treated kangaroo tail tendon (KTT) compared with autografts. At 3 month the mid-sections of the glutaraldehyde-fixed xenografts maintained between 57 and 82% of their initial ultimate tensile strength whereas lyophilized KTT dropped to 10% and autografts retained 91% of initial strength. Sterilization by gamma-radiation of wet xenografts did not affect the material and implant properties significantly. Longer term studies are necessary to determine the resorption behaviour of the xenografts. Anastomosis strengths were found to be about the same for all grafts, at about 25% of the strength of the original tendon. Alternatives need to be investigated to improve this strength.

Anastomosis, Surgical↗

Comparative evaluation of treated bovine pericardium as a xenograft for hernia repair.

Two forms of bovine pericardium (BPC) were assessed as hernia repair materials: non-cross-linked (lyophilized) and cross-linked through treatment with glutaraldehyde (GA). These were compared with polypropylene mesh (Marlex) in a rabbit model. Over 52 wk implantation, the GA BPC grafts developed a strong, stable, fibrous tissue replacement with good incorporation into the abdominal muscle wall. The lyophilized BPC grafts were substantially resorbed within 12 wk of implantation, however the thin, fibrous replacement tissue was inadequate for abdominal wall support. Marlex grafts provided sufficient abdominal support, however these grafts were associated with extensive adhesion formation and, in this model, fat deposition around the perimeter of the graft. Control (ungrafted) rabbit abdominal muscle in the transverse orientation had an ultimate tensile load (UTL) of 11.4 +/- 5.1 N (x +/- s.d.) and a strain at UTL of 35 +/- 12% (n = 169). At 52 weeks the UTL of the repair sites was 7.3 +/- 4.5 N (n = 6), 5.1 +/- 3.5 N (n = 6) and 5.6 +/- 2.7 N (n = 6) for GA BPC, lypophilized BPC and Marlex grafts, respectively.

Animals↗

Autograft and Leeds-Keio reconstructions of the ovine anterior cruciate ligament.

This study compared the Leeds-Keio prosthesis with grafting of autogeneic patellar tendon for the reconstruction of the ovine anterior cruciate ligament under controlled conditions. Reconstructed knees from six sheep of each group were evaluated at 12, 26, and 52 weeks postreconstruction with respect to clinical assessment, gross pathology, mechanical properties, and histology. Although no difference in clinical assessment (anteroposterior draw, range of motion, and function) was noted between the prosthesis reconstruction and the autograft reconstruction, the prosthesis provided a higher strength initially, which remained relatively constant over the one-year study. However, prosthesis wear was observed, with up to 50% of Dacron fibers ruptured in some cases. Histologic sections indicated that in the ovine model, the Leeds-Keio prosthesis should be considered an artificial device and not a scaffold or stent that supports aligned collagenous growth. The autograft had low strength at 12 weeks, which increased over the study period. Despite acceptable clinical performance and adequate mechanical properties up to one year postimplantation, neither reconstruction approached the clinical or mechanical performance of the normal anterior cruciate ligament in the ovine model.

Animals↗

Measurement of the mechanical properties of the ovine anterior cruciate ligament bone-ligament-bone complex: a basis for prosthetic evaluation.

The reported ultimate tensile stress of the anterior cruciate ligament varies greatly, ranging from 13 to 147 MPa. This study shows that the orientation and degree of flexion of the bone-ligament-bone complex significantly alter the apparent ultimate tensile properties (ultimate tensile stress ranging from 60 +/- 3 to 123 +/- 15 MPa, ultimate specific extension from 37 +/- 7 to 93 +/- 20%), whilst the method chosen for measuring extension also affects the calculated specific extension of the bone-ligament-bone complex. It is suggested that, for considerations of prosthesis design and evaluation, the mechanical properties of the bone-ligament-bone complex should be measured in anterior draw and extension measured using points as close as possible to the positions of the ligamentous attachment sites.

Animals↗

Endothelial cell seeding of small diameter vascular grafts.

This study examines, under flow conditions, the adhesion of endothelial cells to 3 mm diameter fibronectin (Fn)-coated expanded polytetrafluoroethylene (PTFE) vascular grafts. Cultured ovine carotid artery endothelial cells were labelled with 35S-methionine. The grafts were seeded with endothelial cells (1.5 x 10(6)/ml) by rolling for 1 h at 37 degrees C and then either cultured to confluence for 48 h or flow tested immediately. Cell attachment to grafts (n = 5) was evaluated in an in vitro flow circuit, using flows of up to 330 ml/min. Ex vivo studies (n = 5 grafts) were conducted without anticoagulant using autologous cells in a sheep model. Grafts were inserted into an externalized carotid-jugular shunt and exposed to blood flows of approximately 150 ml/min for 3 h. One hour seeded and 48 h cultured grafts demonstrated greater than 95% cell retention following in vitro flow studies. Ex vivo studies of 48 h cultured grafts gave endothelial cell retention of 81% with no sign of thrombogenicity. Furthermore, a preliminary 24 h ex vivo study has shown greater than 95% retention. This study demonstrates the firm attachment of seeded endothelial cells to Fn-coated PTFE grafts in the sheep model.

Animals↗

Collagen cross-linking and resorption: effect of glutaraldehyde concentration.

Cross-linked collagen bioprostheses usually are designed to be inert and nonresorbable, resulting in fatigue and wear failure in high-stress environments. Eventual replacement of the implant, although minimizing strength loss during resorption, would result in a graft with reparative ability. Kangaroo tail tendon (KTT) partially cross-linked with glutaraldehyde (GA) was evaluated in vitro for resistance to bacterial collagenase digestion and in vivo for biocompatibility and resorbability in an intramuscular implant assay. Cross-linking was quantified by thermal denaturation studies. Incomplete cross-linking was achieved with concentrations of GA less than 0.1% (w/v). KTT cross-linked in greater than or equal to 0.05% GA were collagenase resistant being incompletely digested after 240 h. Cross-linking of KTT with low concentrations of GA resulted in partial collagenase resistance and slowed resorption.

Animals↗

An evaluation of DNA fluorochromes, staining techniques, and analysis for flow cytometry. I. Unperturbed cell populations.

Several preparative techniques (detergent treatment, ethanol fixation, and hypotonic cell lysis), DNA fluorochromes, and methods of numerical analysis (planimetric or curve-fitting) were compared for the estimation of cell-cycle kinetic parameters (G1, S, G2 + M) by flow cytometry. In addition, coefficients of variation (CV), relative fluorescence, and G1/chicken erythrocyte (CRBC) ratios were measured and the effects of the proportion of cycling cells and cellular RNA content were examined. DNA fluorochromes were ranked by relative fluorescence: 4,6-diamidino-2-phenylindole > ethidium bromide/mithramycin > Hoechst 33342 > mithramycin > ethidium bromide > acridine orange approximately equal to propidium iodide. The first four (DNA-specific stains) gave lower CVs than the remainder (DNA intercalators). Detergent treatment also increased relative fluorescence and slightly lowered CVs. Comparable results were obtained for the kinetic parameters independently of stain or staining procedure; intercalating dyes with cells of a high RNA content not treated with RNAse and acridine orange being the exceptions. Of the two methods of numerical analysis, the planimetric technique was more consistant. Although highly consistant G1/CRBC ratios were obtained for any one stain, independently of staining procedures, variations between stains were noted. It is suggested that the detergent treatment in combination with DNA-specific stains provide optimal results.

Animals↗

The polymerization pattern of zinc(II)-insulin at pH 7.0.

Sedimentation equilibrium experiments were conducted at pH 7.0 using solutions of bovine insulin containing 2 mol of zinc(II) ions per six base-mol of insulin. A detailed analysis of these results revealed the existence of a stable zinc-insulin hexamer together with linked polymerization reactions. Specifically these are a background polymerization of zinc-free insulin as previously described by Jeffrey et al. ((1976) Biochemistry 15, 4660--4665) and a slight tendency for the zinc-insulin hexamer to undergo indefinite self-association. Equilibrium constants governing these reactions are reported together with equations which permit calculation of the composition of the solution at any given total concentration. Comment is made on the possible biological significance of this linked polymerization pattern, and on the likely identity of the structure of the stable zinc-insulin hexamer with that previously reported from X-ray crystallographic studies.

Animals↗

Polymerization pattern of insulin at pH 7.0.

Sedimentation equilibrium results, obtained with bovine zinc-free insulin (with and without a component of proinsulin) at pH 7.0, I o.2, 25 degrees C, and up to a total concentration of 0.8 g/l., are shown to be consistent with three different polymerization patterns, all involving an isodesmic indefinite self-association of specified oligomeric species. The analysis procedure, based on closed solutions formed by summing infinite series, yields for each pattern a set of equilibrium constants, It is shown that a distinction between the possible patterns can be made by analyzing sedimentation equilibrium results obtained in a higher total concentration range (up to 4 g/1.) with insulin freed of zinc and proinsulin, account being taken of the composition dependence of activity coefficients. The favored pattern, which differs from that previously reported in the literature, involves the dimerization of monomeric insulin (mol wt 5734), governed by a dimerization constant of 11 X 10(4) M-1 and the isodesmic indefinite self-association of the dimer, described by an association constant of 1.7 X 10(4) M-1. This polymerization pattern is also shown to be consistent with the reaction boundary observed in sedimentation velocity experiments.

Hydrogen-Ion Concentration↗