PubMed Health⌕ Search

Biomedical subjects

B K Moore

Publications and source records attributed to B K Moore.

At least 19 recordsLinked to original sources

Analysis of the dentin-resin interface by use of laser Raman spectroscopy.

OBJECTIVES: Adhesion of resin-bonding agents to dentin is currently believed to result from impregnation of adhesive resin into superficially demineralized dentin. The purpose of this study was to investigate the chemical composition of the resin-impregnated dentin (hybrid) layer using a micro-Raman spectroscopy. METHODS: Resin composites were bonded to bovine dentin with the two-step bonding systems, and specimens were sectioned parallel to dentinal tubules. These surfaces were then polished down to 1 microm diamond pastes. Raman spectra were successively recorded along a line perpendicular to the dentin-adhesive interface by steps of 0.2 microm on a computer controlled X-Y stage. The relative amounts of hydroxyapatite (960 cm(-1), P-O), adhesive resin (640 cm(-1), aromatic ring), and organic substrate (1450 cm(-1), C-H) in the dentin-adhesive bonding area were calculated. RESULTS: From the Raman spectroscopy results, the hybrid layer represents a gradual transition in the relative amount of adhesive from the resin side to dentin side. Evidence of poor saturation of the adhesive resin in the demineralized dentin with the one-bottle adhesive system was detected. SIGNIFICANCE: From the results of this study, inhomogeneity of the hybrid layer composition was detected, and the degree of resin impregnation was found to be different between the bonding systems tested.

Animals↗

A pilot clinical evaluation of a new injection denture base system.

The purpose of this pilot study was to determine if clinically acceptable complete denture prostheses can be consistently fabricated with a new injection system. In the first part of this investigation, 14 patients requiring complete denture fabrication had one prosthesis made with the new injection system and one made with the compression-pack technique. Polish, porosity, and esthetics were evaluated by one of three investigators at the placement visit. The percentage of the intaglio surface in contact with the mucosa before adjustment was also measured. One week after placement, the patients were questioned regarding the prostheses' stability, the presence of any undesirable taste, and overall satisfaction. The second portion of the study involved materials property testing of flexural strength and Izod toughness of conventionally packed and injection-packed specimens processed by the fast cycle or the long cycle. In every case, acceptable results were obtained for the resin's polishability, its lack of porosity, esthetics, stability, lack of unpleasant taste, and overall patient satisfaction with the prostheses. No difference in clinical adaptation was observed. These results indicated that no clinical difference was detectable between the conventionally packed and injection-packed denture bases by the investigators or patients in this study. Physical property testing indicates that the differences between groups may be more affected by the polymerization cycle used than the way that the resin was placed in the mold space.

Acrylic Resins↗

Enamel and dentin bond strengths of single application bonding systems.

PURPOSE: To investigate the bonding ability to enamel and dentin of new single application bonding systems (Reactmer and One-Up Bond) and compare these with a commercial compomer (Clicker/F2000), and 2-step resin-based composite bonding systems (Fluoro Bond/Lite-Fil II A and Single Bond/Z100). MATERIALS AND METHODS: Labial surfaces of extracted bovine teeth were ground on wet 600-grit SiC paper to expose a flattened area of enamel or dentin and then washed and dried with oil-free compressed air. These surfaces were treated according to each adhesive system's instructions and the restorative materials were condensed into a Teflon mold (2 mm height, 4 mm internal diameter) and then irradiated. The finished specimens were stored in 37 degrees C distilled water for 24 hours from the start of light exposure to the material. Then these specimens were tested in a shear mode at a crosshead speed of 1.0 mm/minute. The mean and standard deviation were subjected to an ANOVA followed by the Duncan test (P< 0.05). RESULTS: The bond strengths of the single application bonding systems were 12.3 to approximately 14.5 MPa for enamel, and 13.7 to approximately 13.8 MPa for dentin. These values were comparable to those of the compomer (12.6 MPa for enamel, and 13.1 MPa for dentin), but lower than those of the two-step resin composite bonding systems (16.8 to approximately 21.7 MPa for enamel and 18.1 to approximately 18.4 MPa for dentin).

Analysis of Variance↗

Study of the physical properties of type IV gypsum, resin-containing, and epoxy die materials.

STATEMENT OF PROBLEM: Little published information is available comparing the properties of recently developed resin-modified gypsum and epoxy resin die materials, which are claimed to be superior to conventional type IV gypsum die materials. PURPOSE: This study compared the properties of 3 new die materials and 2 conventional type IV gypsum products. METHODS AND MATERIAL: The linear dimensional change, detail reproduction, surface hardness, abrasion resistance, and transverse strength of 2 recently introduced, resin-modified gypsum die materials (Resinrock and Milestone), a new epoxy resin die material (Epoxy-Die), and 2 conventional type IV gypsum die materials (Silky-Rock and Die-Stone) were studied. RESULTS: All gypsum products expanded, whereas the epoxy resin material contracted during setting. The epoxy resin exhibited much better detail reproduction, abrasion resistance, and transverse strength than the gypsum materials, which were similar in these properties. A conventional type IV gypsum exhibited the highest surface hardness, whereas the epoxy resin had the lowest value. CONCLUSION: The resin-modified gypsum products were not significantly superior to the conventional type IV gypsum die materials. In general, the epoxy resin exhibited the best properties of the materials studied; however, its setting shrinkage may necessitate alterations in technique to achieve well-adapted castings.

Analysis of Variance↗

Microleakage and retention of bonded amalgam restorations.

PURPOSE: To compare the microleakage and bond strength exhibited by two light-cured, filled dentin bonding agents, a resin cement, and cavity varnish. MATERIALS AND METHODS: The four test groups of lining agents for amalgam restorations included (LF) Light-cured, Filled resin (Clearfil Liner Bond 2); (LCF) light- and chemical-cured, Filled resin (Clearfil Liner Bond + Protect Liner); (RC) Resin Cement (Panavia 21); and (V) Varnish (Copalite). For each group, 20 Class V cavity preparations were cut in human extracted molars. Tytin amalgam was condensed into the preparation. After storage for at least 24 hrs in distilled water at 37 degrees C, all restorations were subjected to 2500 thermal cycles (8 degrees C to 48 degrees C). After 1 wk, specimens were tested. For the leakage tests, teeth were immersed in 45Ca, sectioned, and radiographs of sections were evaluated and then evaluated by Ridit analysis. Retention samples were tested to failure in tension using an Instron machine and peak load (kg) was recorded. RESULTS: Compared to varnish, the two dentin bonding agents (LF and LCF) significantly decreased microleakage at the cementum margin but not at the enamel margin. The two dentin bonding agents also exhibited significantly greater retentive strength than either the resin cement or the varnish.

Calcium Radioisotopes↗

Effect of operator variability on dentin bond strength of two-step bonding systems.

PURPOSE: To examine the influence of operator variability on adhesion to dentin of recently developed two-step bonding systems. MATERIALS AND METHODS: A self-etching primer system, Fluoro Bond/Lite-Fil II A (FB) and a one-bottle adhesive system, Single Bond/Z100 (SB) were employed. Three groups, each consisting of 15 operators, were selected from the dentists at the university (Group 1), undergraduate students (Group 2), and general practitioners (Group 3). Labial surfaces of extracted bovine teeth were ground on wet 600-grit SiC paper and then washed and dried with oil-free compressed air. These surfaces were treated according to each adhesive system's instructions and the restorative resins were condensed into a Teflon mold (2 mm height, 4 mm internal diameter) and then light-cured. The finished specimens were stored in 37 degrees C distilled water for 1 hr. These specimens were tested in a shear mode at a cross-head speed of 1.0 mm/min. The mean and standard deviation were subjected to two-way ANOVA (P < 0.05). RESULTS: Significant differences in bond strength of the two adhesives were found within each operator group. A wider variation in bond strength was seen for SB compared to FB for the three different groups. Mean bond strengths for the faculty group were statistically greater than those of the other two groups, which did not differ significantly. Even though the specimen preparation was done under in vitro conditions, the large coefficients of variation indicate it may be difficult to create suitable surface conditions for optimal bonding.

Adhesiveness↗

Color stability and colorant effect on maxillofacial elastomers. Part I: colorant effect on physical properties.

STATEMENT OF PROBLEM: The average clinical life span of a maxillofacial prosthesis is approximately 6 months, at which point it needs to be refabricated, mainly because of degradation of the color and physical properties of the prosthesis. PURPOSE: This first part of a 3-part study evaluated the effect of coloring agents on the physical properties of maxillofacial elastomers. METHODS AND MATERIAL: Five dumbbell-shaped and 5 trouser-shaped specimens were fabricated for each of the combinations of the 3 elastomers (Silastic medical adhesive type A, Silastic 4-4210, and Silicone A-2186) and 6 colorants (dry earth pigments, rayon fiber flocking, artist's oil paints, kaolin, liquid cosmetics, and no-colorants), for a total of 180 specimens. Evaluations of hardness and tear strength were made with the trouser-shaped specimens. Evaluations of the ultimate tensile strength and the percentage elongation were made with the dumbbell-shaped specimens. A within elastomer analysis compared the 6 colorants using a 1-way analysis of variance for each of the 4 physical properties. When significant differences were observed, the Student-Newman-Keuls multiple range test was used to identify differences between groups at a significance level of.05. RESULTS: Physical properties of maxillofacial elastomers were changed by the incorporation of coloring agents. Dry earth pigments, kaolin, and rayon flocking acted as a solid filler without bonding to the Silicone, and artists' oils and liquid cosmetics acted as a liquid phase without bonding to the silicone matrix. CONCLUSION: No clearly superior colorant-elastomer combination was demonstrated in all the tests in this study.

Analysis of Variance↗

Color stability and colorant effect on maxillofacial elastomers. Part II: weathering effect on physical properties.

STATEMENT OF PROBLEM: The clinical life of a maxillofacial prosthesis averages about 6 months, before it needs to be refabricated. Degradation of the color and physical properties of the prosthesis are the principle reasons for replacement. PURPOSE: This second part of a 3-part in vitro investigation evaluated the change in physical properties of popular colorant-elastomer combinations as a result of weather exposure. MATERIAL AND METHODS: Fifteen dumbbell-shaped and 15 trouser-shaped specimens were fabricated for each of the 3 elastomers (Silastic medical adhesive type A, Silastic 4-4210, and Silicone A-2186) and 6 colorant combinations (dry earth pigments, rayon fiber flocking, artist's oil paints, kaolin, liquid cosmetics, and no-colorants) for a total of 540 specimens. The 15 dumbbell-shaped and trouser-shaped specimens of each elastomer colorant combination were separated into 5 of each shape among 3 test condition groups (control, time passage, and natural weathering). Control specimens were evaluated within 1 month of fabrication. The time passage group was sealed in glass containers and kept in the dark for 6 months before testing. The natural-weathering groups were placed on the roof of the dental school for 6 months and exposed to sunlight and weathering. Evaluations of hardness and tear strength were made on trouser-shaped specimens, and evaluations of the ultimate tensile strength and percentage elongation on dumbbell-shaped specimens. Physical property data for each elastomer-colorant combination were subjected to a 1-way analysis of variance to examine effects among the test conditions. When significant differences were observed, the Student-Newman-Keuls multiple range test was performed to identify differences in elastomer-colorant combinations among each test condition at a significance level of .05. RESULTS: Exposure to weathering and time changes of the physical properties of many colorant-elastomer combinations indicated that properties of a clinical prosthesis can change with time. CONCLUSION: The addition of colorants to the silicones altered the effects of weathering. In addition, the silicones were not as stable as previously assumed.

Analysis of Variance↗

Color stability and colorant effect on maxillofacial elastomers. Part III: weathering effect on color.

STATEMENT OF PROBLEM: Maxillofacial prostheses are serviceable for approximately 6 months, after which they need to be refabricated because of the deterioration of color and physical properties. PURPOSE: This third article in a 3-part series evaluated the color stability of commonly used colorant-elastomer combinations as a result of exposure to weathering. METHODS AND MATERIAL: Fifteen specimens were fabricated for each of the 3 elastomers (Silastic medical adhesive type A, Silastic 4-4210, and Silicone A-2186) and 6 colorants (dry earth pigments, rayon fiber flocking, artist's oil paints, kaolin, liquid cosmetics, and no colorant) for a total of 270 specimens (18 groups of 15 specimens). The 15 specimens of each elastomer-colorant combination were separated into 3 test condition groups (control, time passage, and natural weathering) of 5 specimens per test condition group. Control specimens were evaluated within 1 month of fabrication. The time passage group was sealed in glass containers and kept in the dark for 6 months before testing. The natural weathering groups were placed on the roof of the dental school for 6 months and exposed to sunlight and weathering. Color and optical density data for each elastomer-colorant combination were subjected to a 1-way analysis of variance to examine effects among test conditions (control, time passage, and weathering). When significant differences were observed, the Student-Newman-Keuls multiple range test was performed to identify differences in elastomer-colorant combinations among each test condition at a significance level of .05. RESULTS: Changes in color, as a result of weathering, were noted in many of the colorant-elastomer combinations. Also, color change occurred not only to the colored, but also to uncolored materials over time without exposure to weathering. CONCLUSION: Clinically, the addition of colorants could have a stabilizing effect on the elastomer color when it is exposed to weathering.

Analysis of Variance↗

Influence of self-etching primer drying time on enamel bond strength of resin composites.

OBJECTIVES: In clinical situations, a dentine primer is usually applied to enamel, in addition to dentine. This study was carried out to determine the influence of the air drying time of self-etching primers on their bond strength to enamel. METHODS: Three self-etching primer systems, Fluoro Bond (FB, Shofu Inc.), Liner Bond II (LB, Kuraray Co.) and Mac Bond 2 (MB, Tokuyama Co.) were employed. Bovine mandibular incisors were mounted in self-curing resin and the enamel surfaces were wet ground with number 600 SiC paper. Following primer application, the enamel surface was dried with compressed air for 0, 2, 5, 10, 20, and 30 s from 10 cm above the enamel surface using a three-way syringe. Adhesives were applied and composites were condensed into a Teflon mold (4 x 2 mm) placed on the enamel and light activated. Ten samples per test group were stored in 37 degrees C water for 24 h, then shear tested at a crosshead speed of 1.0 mm min-1. One-way ANOVAs followed by Duncan tests (p < 0.05) were done. RESULTS: The enamel bond strengths varied with the different air drying times and ranged from 8.2 +/- 3.2-17.4 +/- 3.0 MPa for LB, 10.9 +/- 2.8-16.3 +/- 3.3 MPa for FB, and 17.5 +/- 2.5-19.4 +/- 2.2 MPa for MB. For LB and FB, there appeared to be a minimum drying time of 10 s. LB was the most affected by drying time, while MB did not change. CONCLUSIONS: The data suggests that the enamel bond strengths of these bonding systems can be influenced by the drying time of the primer applied prior to bond agent application and the tendency was different among the systems studied.

Acid Etching, Dental↗

Friction in perspective.

In the past, most frictional resistance studies have been conducted in a steady state condition that does not simulate the dynamics of the oral environment. Various oral functions as chewing, swallowing, speaking, etc, as well as the oral tissues contacting any orthodontic appliances, result in periodic, repetitive, minute relative motion at the bracket/arch wire interfaces several thousand times each day. This in turn affects the normal forces at the interfaces, and because frictional resistance is directly proportional to the normal force, a pilot study was undertaken to emulate the dynamic environment of the oral cavity and its effect on frictional resistance. Tests of a limited sample of stainless steel arch wires and brackets typically used in sliding mechanics revealed that frictional resistance was effectively reduced to zero each time minute relative movements occurred at the bracket/arch wire interfaces. Factors such as the degree of dental tipping, relative arch wire/slot clearances, and method of tying, did not have a measurable effect on frictional resistance in the simulated dynamics of the oral environment.

Dental Stress Analysis↗

Resin-modified glass-ionomers: effect of dentin primer application on the development of bond strength.

The purpose of this study was to investigate the rate of development of dentin bond strengths of resin-modified glass-ionomer cements (RMGIC) with use of dentin primers. The prepared dentin surface was treated according to each manufacturer's instruction or the dentin primer. Cements were condensed into a vinyl mold and light activated. The shear bond strengths were measured at a crosshead speed of 1.0 mm/min after 1, 5, 10, 30, 60 min, 2, 5, and 24 h storage in water at 37 degrees C. Presence of a significant difference between the mean bond strength at 1 min and each of the other test times was analyzed. The first time at which there was a significant increase in bond strength was defined as the "initial increasing time". As compared with the manufacturer's suggested dentin treatments, the bond strengths increased significantly when the dentin primers were used. The initial increasing times when the specimens were made following each manufacturer's instructions were 10 approximately 60 min. When dentin primer was used, the initial increasing time shortened to 5 approximately 10 min. It was concluded that the use of dentin primers for RMGIC restorations resulted in reduction of the initial increasing time.

Acrylic Resins↗

A clinical study of the effect of pellicle on the degradation of 10% carbamide peroxide within the first hour.

OBJECTIVE: The purpose of this study was to determine the degradation of 10% carbamide peroxide within the first hour of use and the effect of pellicle on the degradation of carbamide peroxide in vivo. METHOD AND MATERIALS: Fifteen subjects were assigned to wear nightguard trays filled with bleaching gel for 0.5, 2.5, 5.0, 10.0, 20.0, 40.0, and 60.0 minutes under 2 conditions: (1) subjects did not receive a prophylaxis before each bleaching treatment (pellicle was assumed to be present on the tooth surface); and (2) subjects received prophylaxis to remove pellicle from the tooth surface. At each evaluation time, 3 types of sample were collected: (1) a "grab sample," a sample of gel taken with a spatula from the reservoir of the tray on the maxillary right central incisor; (2) the remaining gel from the tray; and (3) the remaining gel scraped from the teeth. The collected gel samples were analyzed for the amount of peroxide using the United States Pharmacopeia-accepted method. Subjects were asked not to swallow the saliva during treatment but to expectorate into a beaker. The collected saliva was analyzed to determine the amount of peroxide. This sample represented the approximate amount of peroxide that subject would ingest during treatment. RESULTS: Pellicle did not affect the degradation of carbamide peroxide for the teeth or grab samples. The degradation of carbamide peroxide was exponential, except during the first 5 minutes, when the degradation rate was much higher. The saliva collected from subjects during use of the bleaching tray revealed an average of 2.1 mg of carbamide peroxide for 1 hour of bleaching treatment. CONCLUSION: The degradation rate is not affected by the removal of the pellicle.

Analysis of Variance↗

Effect of microfiller fraction and silane treatment on resin composite properties.

A series of microfilled resin composites were formulated by incrementally mixing either agglomerated 20 nm or unagglomerated 50 nm silica microfillers into monomers composed of diphenyloxymethacrylate and TEGDMA. The microfiller particles were prepared with and without a gamma-methacryloxypropyl-trimethoxy silane coupling agent. Following polymerization, five material properties were tested: uniaxial tensile strength, Young's modulus in slow compression, Knoop hardness, water sorption, and toothbrush abrasion resistance. Results from these tests indicated that microfiller content clearly was the most influential parameter affecting material property performance. Composites containing 20 nm particles demonstrated greater water sorption, higher Knoop hardness, and better resistance to toothbrush wear. Surprisingly, the application of silane to microfiller surfaces did not greatly improve composite performance for most of the material properties tested in this study. However, water sorption behavior over a 3-year period was observed to be more stable for materials possessing silane-treated particles. Future evaluation of coupling agents should include long-term water storage prior to conducting mechanical tests.

Biocompatible Materials↗

Microhardness and anisotropy of the vital osseous interface and endosseous implant supporting bone.

Limited information is available on the mechanical properties of the rapidly remodeling bone that surrounds endosseous implants. Fifteen implant-bone blocks were obtained from the mid-femoral diaphyses of three mature male hounds 12 weeks after placement of the implants. To evaluate the microhardness and cortical anisotropy of bone, the implants were sectioned along their long axes. In this process, the femurs were sectioned transversely. Knoop microhardness measurements (HK) were made with a 50 g force on cortical bone and a 25 g force on periosteal callus, endocortical callus, and circumferential lamellar bone. The long diagonal of the indenter was placed parallel to the implant (in the radial bone direction). Measurements were made in cortical bone at 200, 400, 600, 800, 1,000, 1,500, 2,000, and 2,500 microm from both sides of the implant. To detect cortical anisotropy in the radial compared with the tangential direction, a second set of indentations was made perpendicular to the first. Microhardness of periosteal callus and endocortical callus and anisotropy of circumferential lamellar bone near the endocortical surfaces of the femur were also evaluated. Repeated measures analysis of variance showed significantly (p < 0.05) lower microhardness values (30.6 +/- 0.8 HK [mean +/- SEM]) for cortical bone at 200 microm than at any other location (range: 40.3-46.6 HK). Microhardness anisotropy was not detected in cortical bone. Furthermore, within 200 microm of the implant surface, the Knoop microhardness values were significantly lower for periosteal and endocortical calluses than for cortical bone. These data provide information about the mechanical properties of bone adjacent to endosseous implants at a microstructural level. The results are consistent with the high rate of remodeling seen adjacent to endosseous implants at 12 weeks after implantation.

Animals↗

In vitro study of fracture incidence and compressive fracture load of all-ceramic crowns cemented with resin-modified glass ionomer and other luting agents.

STATEMENT OF PROBLEM: Anecdotal reports based on clinical observation have recently linked resin-modified glass ionomer luting agents with postcementation fracture of all-ceramic crowns. PURPOSE: This study evaluated the fracture incidence of In-Ceram and VitaDur Alpha porcelain jacket all-ceramic crowns cemented with 5 luting agents (Fuji I, Fuji Plus, Vitremer, Advance, and Panavia 21) during 2 months storage in 0.8% NaCl solution. MATERIAL AND METHODS: Fifty human maxillary premolar teeth were prepared for each ceramic system and divided into 5 subgroups of 10 teeth to be cemented with 5 luting cements. Specimens were observed for fracture lines and crack initiation at storage times up to 2 months. Incidence of fracture was analyzed with Fisher's Exact test. Specimens that did not fracture during storage were loaded in compression to failure. Failure loads were analyzed by analysis of variance and multiple pairwise comparisons. RESULTS: Only all-ceramic crowns cemented with Advance cement fractured during the 2-month observation period, and porcelain jacket crowns were found to fracture earlier and more frequently than In-Ceram crowns. Cracks initiated at the crown margin, and multiple crack lines were found as the time of storage increased. In-Ceram crowns were significantly stronger (140 +/- 21.5 kg) than porcelain jacket crowns (98.6 +/- 17.8 kg) at P <.05. For In-Ceram crowns, cement type did not influence failure load while for porcelain jacket crowns, Fuji I (110.5 kg) was significantly higher than Vitremer (86.6 kg) at P <.05. CONCLUSIONS: For the cements studied, only crowns cemented with Advance cement demonstrated fracture during 2-month storage. Results for the true resin-modified glass ionomer cements do not support anecdotal reports of fracture of all-ceramic crowns cemented with these materials.

Cementation↗

Using a colorimeter to develop an intrinsic silicone shade guide for facial prostheses.

PURPOSE: To determine if using CIE L*a*b* color measurements of white facial skin could be correlated to those of silicone shade samples that visually matched the skin. Secondly, to see if a correlation in color measurements could be achieved between the silicone shade samples and duplicated silicone samples made using a shade-guide color formula. MATERIALS AND METHODS: A color booth was designed according to ASTM specifications, and painted using a Munsell Value 8 gray. A Minolta colorimeter was used to make facial skin measurements on 15 white adults. The skin color was duplicated using custom-shaded silicone samples. A 7-step wedge silicone shade guide was then fabricated, representing the commonly encountered thicknesses when fabricating facial prostheses. The silicone samples were then measured with the Minolta colorimeter. The readings were compared with the previous L*a*b* readings from the corresponding patient's skin measurements, and the relative color difference was then calculated. Silicone samples were fabricated and analyzed for three of the patients to determine if duplication of the visually matched silicone specimen was possible using the silicone color formula, and if the duplicates were visually and colorimetrically equivalent to each other. The color difference Delta E and chromaticity was calculated, and the data were analyzed using a coefficient-of-variation formula expressed by percent. A Pearson Product Moment Correlation Coefficient was performed to determine if a correlation existed between the skin and the silicone samples at the p < or = .05 level. RESULTS: The highest correlation was found in the b* dimension for silicone thicknesses of 1 to 4 mm. For silicone thicknesses of 6 to 10 mm, the highest correlation was found in the L* dimension. All three dimensions had positive correlations (R2 > 0), but only the 1-mm and 4-mm b* readings were very strong. Patient and silicone L*a*b* measurement results showed very little change in the a* axis, while the L* and b* measurements showed more change in their numbers, with changes in depth for all patient silicone samples. Delta E numbers indicated the lowest Delta E at the 1-mm depth and the highest Delta E at the 10-mm depth. All duplicated samples matched their original silicone samples to a degree that visual evaluation could not distinguish any color differences. Using volumetric measurements, a shade guide was developed for all 15 patients. CONCLUSIONS: There was good correlation between the patient's colorimeter measurements and the silicone samples, with the b* color dimension the most reproducible, followed by the L* and the a*. Silicone samples at 6, 8, and 10 mm matched the patient the best, and this study showed that silicone samples can be duplicated successfully if a good patient-silicone match is obtained. Rayon flocking fibers and liquid makeup are effective at matching facial prostheses and can be used to develop a simple shade guide for patient application.

Color↗

Corrosion behavior of sensitized duplex stainless steel.

The present work investigates the corrosion behavior of 2205 duplex stainless steel in 0.9% NaCl solution after various heat-treatments, and compares it to that of 316L austenitic stainless steel. Both stainless steels were heat-treated at 500, 650, and 800 degrees C in air for 1 h, followed by furnace cooling. Each heat-treated sample was examined for their microstructures and Vickers micro-hardness, and subjected to the X-ray diffraction for the phase identification. Using potentiostatic polarization method, each heat-treated sample was corrosion-tested in 37 degrees C 0.9% NaCl solution to estimate its corrosion rate. It was found that simulated sensitization showed an adverse influence on both steels, indicating that corrosion rates increased by increasing the sensitization temperatures.

Corrosion↗