Fast Fourier projection for MR angiography.

We have developed a technique called fast Fourier projection which rapidly produces projections through images and is particularly useful for generating MR angiograms. Based on the projection-slice theorem of Fourier transform theory, this method extracts planes from three-dimensional spatial frequency space and computes projections at arbitrary viewing angles by two-dimensional inverse Fourier transformation. Typical computation times are on the order of 1 s per projection. This performance makes possible interactive selection of optimal projection directions for visualizing the desired vasculature in single or stereo-pair angiographic images and drastically reduces the time required to generate sequences of projections for display in movie loops compared to the conventional ray-casting approach. The method is easily implemented on off-line workstations or directly on MRI computer systems.

Angiography

Magnetic resonance techniques for blood-flow measurement and vascular imaging.

The authors review the history and physical principles behind vascular magnetic resonance imaging (MRI) techniques, developed to measure blood flow noninvasively and to display images of the vasculature. All these techniques have been used to create magnetic resonance angiograms, in which the vasculature is shown in a projection format similar to x-ray angiography. Signal loss limits the effectiveness of "white-blood" magnetic resonance angiography techniques, since slow flow and complex flow often cause a drop in signal and consequently a loss of accuracy in depicting vessel anatomy. "Black-blood" magnetic resonance angiography is described as a method that avoids these problems of signal loss. Selective black-blood magnetic resonance angiography is introduced as a technique for improving the visualization of the vasculature when other signal-void structures are present in the volume of interest.

Blood

Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging.

Three-dimensional (3D) velocity maps acquired with 3D phase-contrast magnetic resonance (MR) imaging contain information regarding complex motions that occur during imaging. A technique called simulated streamlines, which facilitates the display and comprehension of these velocity data, is presented. Single or multiple seed points may be identified within blood vessels of interest and tracked through the velocity field. The resulting trajectories are combined with a 3D MR angiogram and displayed with 3D volume visualization software. Mathematical analysis highlights potential applications and pitfalls of the technique, which was implemented both in phantoms and in vivo with excellent results. For example, single streamlines reveal helical flow patterns in aneurysms, and multiple streamlines seeded in the common carotid artery reveal branch filling-time relationships and slow filling of the carotid bulb. The technique is helpful in understanding these complex flow patterns.

Blood Flow Velocity

Computer-controlled flow simulator for MR flow studies.

A novel computer-controlled flow simulator for use in magnetic resonance (MR) flow experiments was evaluated. The accuracy in constant-flow mode was better than 1%. The accuracy in pulsatile-flow mode was found to be dependent on the interconnecting tubing. The short-term and long-term reproducibilities of pulsatile waveforms were less than or equal to 0.4 mL/sec (1 standard deviation). Increased response times due to the lengths of tubing required in MR flow experiments were surmounted by using a modified tubing configuration and precompensated waveforms. Piston reversal was found not to cause major difficulties in MR flow experiments.

Blood Circulation

A prototype high-purity germanium detector system with fast photon-counting circuitry for medical imaging.

A data-acquisition system designed for x-ray medical imaging utilizes a segmented high-purity germanium (HPGe) detector array with 2-mm wide and 6-mm thick elements. The detectors are contained within a liquid-nitrogen cryostat designed to minimize heat losses. The 50-ns pulse-shaping time of the preamplifier electronics is selected as the shortest time constant compatible with the 50-ns charge collection time of the detector. This provides the detection system with the fastest count-rate capabilities and immunity from microphonics, with moderate energy resolution performance. A theoretical analysis of the preamplifier electronics shows that its noise performance is limited primarily by its input capacitance, and is independent of detector leakage current up to approximately 100 nA. The system experimentally demonstrates count rates exceeding 1 million counts per second per element with an energy resolution of 7 keV for the 60-keV gamma ray photon from 241Am. The results demonstrate the performance of a data acquisition system utilizing HPGe detector systems which would be suitable for dual-energy imaging as well as systems offering simultaneous x-ray transmission and radionuclide emission imaging.

Americium