PubMed HealthSearch

Biomedical subjects

B Kasemo

Publications and source records attributed to B Kasemo.

16 recordsLinked to original sources

Monte Carlo simulation of denaturation of adsorbed proteins.

Denaturation of model proteinlike molecules at the liquid-solid interface is simulated over a wide temperature range by employing the lattice Monte Carlo technique. Initially, the molecule containing 27 monomers of two types (A and B) is assumed to be adsorbed in the native folded state (a 3 x 3 x 3 cube) so that one of its sides is in contact with the surface. The details of the denaturation kinetics are found to be slightly dependent on the choice of the side, but the main qualitative conclusions hold for all the sides. In particular, the kinetics obey approximately the conventional first-order law at T > Tc (Tc is the collapse temperature for solution). With decreasing temperature, below Tc but above Tf (Tf is the folding temperature for solution), deviations appear from the first-order kinetics. For the most interesting temperatures, that is, below Tf, the denaturation kinetics are shown to be qualitatively different from the conventional ones. In particular, the denaturation process occurs via several intermediate steps due to trapping in metastable states. Mathematically, this means that (i) the transition to the denatured state of a given molecule is nonexponential, and (ii) the denaturation process cannot be described by a single rate constant kappar. One should rather introduce a distribution of values of this rate constant (different values of kappar correspond to the transitions to the altered state via different metastable states).

Adsorption

Monte Carlo simulation of the kinetics of protein adsorption.

Adsorption of proteins occurs via diffusion toward the interface, actual adsorption, and subsequent irreversible conformational changes resulting in denaturation of the native protein structure. The conventional kinetic models describing these steps are based on the assumption that the denaturation transitions obey the first-order law with a single value of the denaturation rate constant kappar. Meanwhile, recent Monte Carlo simulations indicate that, in general, the denaturation process cannot be described by a single rate constant kappar. One should rather introduce a distribution of this rate constant (physically, different values of kappar correspond to the transitions to the altered state via different metastable states). We have calculated the kinetics of irreversible adsorption of proteins with and without distribution of the denaturation rate constant kappar in the limits when protein diffusion in the solution is, respectively, rapid or slow. In both cases, the adsorption kinetics with distribution of kappar are found to be close to those with a single-valued rate constant kappar provided that the average value of kappar in the former case is equal to kappar for the latter case. This conclusion holds even for wide distributions of kappar. The consequences of this finding for the fitting of global experimental kinetics on the basis of phenomenological equations are briefly discussed.

Adsorption

Monte Carlo simulation of protein folding with orientation-dependent monomer-monomer interactions.

We present the results of lattice Monte Carlo simulations of protein folding in the framework of a model taking into account (i) the dependence of the energy of interaction of amino-acid residues on their orientation and (ii) the rigidity of the polypeptide chain with respect to the formation of kinks. If the chain is flexible, the final protein structures are predicted to be compact. Increasing the energy cost of creation of kinks is found to favor the formation of flat structures mimicking an ideal antiparallel beta sheet. For compact structures, the kinetics of folding exhibit the standard two-phase regime (a rapid collapse to one of the metastable stable, followed by slow reconfiguration of the chain to the native structure). For flat structures, the transition to the native state is often gradual.

Algorithms

Glow discharge plasma treatment for surface cleaning and modification of metallic biomaterials.

Glow discharge plasma treatment is a frequently used method for cleaning, preparation, and modification of biomaterial and implant surfaces. The merits of such treatments are, however, strongly dependent on the process parameters. In the present work the possibilities, limitations, and risks of plasma treatment for surface preparation of metallic materials are investigated experimentally using titanium as a model system, and also discussed in more general terms. Samples were treated by different low-pressure direct current plasmas and analyzed using Auger electron spectroscopy (AES), x-ray photoelectron spectroscopy (XPS), atomic force microscopy, scanning electron microscopy, and light microscopy. The plasma system is a home-built, ultra-high vacuum-compatible system that allows sample introduction via a load-lock, and precise control of pressure, gas composition and flow rate, etc. This system allows uniform treatment of cylindrical and screw-shaped samples. With appropriate plasma parameters, argon plasma remove all chemical traces from former treatments (adsorbed contaminants and other impurities, and native oxide layers), in effect producing cleaner and more well-controlled surfaces than with conventional preparation methods. Removal (sputtering) rates up to 30 nm/min are possible. However, when inappropriate plasma parameters are used, the result may be increased contamination and formation of unintentional or undesired surface layers (e.g., carbides and nitrides). Plasma-cleaned surfaces provide a clean and reproducible starting condition for further plasma treatments to form well-controlled surface layers. Oxidation in pure O2 (thermally or in oxygen plasmas) results in uniform and stoichiometric TiO2 surface oxide layers of reproducible composition and thicknesses in the range 0.5-150 nm, as revealed by AES and XPS analyses. Titanium nitride layers were prepared by using N2 plasmas. While mild plasma treatments leave the surface microstructure unaffected, heavy plasma treatment can give rise to dramatic morphologic changes. Comparison of these results with corresponding analyses of commercial implants and electropolished and/or anodically oxidized samples shows that the plasma treatment offers superior control of the surface status. However, it is also shown that improper control of the plasma process can produce unwanted and irreproducible results.

Argon

Chemical characterization and reactivity of iron chelator-treated amphibole asbestos.

Iron in amphibole asbestos is implicated in the pathogenicity of inhaled fibers. Evidence includes the observation that iron chelators can suppress fiber-induced tissue damage. This is believed to occur via the diminished production of fiber-associated reactive oxygen species. The purpose of this study was to explore possible mechanisms for the reduction of fiber toxicity by iron chelator treatments. We studied changes in the amount and the oxidation states of bulk and surface iron in crocidolite and amosite asbestos that were treated with iron-chelating desferrioxamine, ferrozine, sodium ascorbate, and phosphate buffer solutions. The results have been compared with the ability of the fibers to produce free radicals and decompose hydrogen peroxide in a cell-free system in vitro. We found that chelators can affect the amount of iron at the surface of the asbestos fibers and its valence, and that they can modify the chemical reactivity of these surfaces. However, we found no obvious or direct correlations between fiber reactivity and the amount of iron removed, the amount of iron at the fiber surface, or the oxidation state of surface iron. Our results suggest that surface Fe3+ ions may play a role in fiber-related carboxylate radical formation, and that desferrioxamine and phosphate groups detected at treated fiber surfaces may play a role in diminishing and enhancing, respectively, fiber redox activity. It is proposed that iron mobility in the silicate structure may play a larger role in the chemical reactivity of asbestos than previously assumed.

Asbestos, Amphibole

Bone response to surface-modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses.

The bone formation around titanium implants with varied surface properties is investigated. Machined and electropolished samples with and without thick, anodically formed surface oxides were prepared, surface characterized and inserted in the cortical bone of rabbits (1, 3 and 6 weeks). Scanning electron microscopy, scanning Auger electron spectroscopy and atomic force microscopy revealed marked differences in oxide thickness, surface topography and roughness, but no significant differences in surface chemical composition, between the different groups of implants. Light microscopic morphology and morphometry showed that all implants were in contact with bone and had a large proportion of bone within the threads at 6 weeks. The smooth, electropolished implants, irrespective of anodic oxidation, were surrounded by less bone than the machined implants after 1 week. After 6 weeks the bone volume as well as the bone-implant contact were lower for the merely electropolished implants than for the other three groups. Our study shows that a high degree of bone contact and bone formation are achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, the result with the smooth (electropolished) implants indicates that a reduction of surface roughness, in the initial phase, decreases the rate of bone formation in rabbit cortical bone.

Animals

Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology.

In a series of experimental studies, bone formation was analysed around systematically modified titanium implants. In the present study, machined, electropolished and anodically oxidized implants were prepared, surface characterized and inserted in the cortical bone of rabbits (7 wks and 12 wks). SEM, scanning Auger electron spectroscopy and atomic force microscopy revealed no differences in surface composition but marked differences in oxide thickness, surface topography and roughness. Light microscopic morphology and morphometry showed that all implants were in contact with bone, and had a large proportion of bone within the threads. The smooth, electropolished implants were surrounded by less bone than the machined implants with similar oxide thickness, (4-5 nm) and the anodically oxidized implants with thicker oxides (21 nm and 180 nm, respectively) after 7 wks. These studies show that a high degree of bone contact and bone formation can be achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, it appears that a reduction of surface roughness may influence the rate of bone formation in rabbit cortical bone.

Animals

Site-specific adhesion of Staphylococcus epidermidis (RP12) in Ti-Al-V metal systems.

Staphylococcus epidermidis (RP12) adhesion patterns were studied on the following titanium (Ti)-aluminium (Al)-vanadium (V) metal systems: (i) microfabricated samples consisting of Ti, Al and V islands deposited onto Ti or V substrata, (ii) pure Ti, Al and V metals, and (iii) medical grade Ti6Al4-V alloy. All of these surfaces were covered with their respective oxides formed upon exposure of the metals to air. Quantitative analysis of the number of cells bound per unit area indicates that S. epidermidis (RP12) exhibits greatest adhesion to pure V surfaces. When exposed to surfaces having controlled spatial variations in chemical composition on the 10 microns scale (microfabricated samples), the bacteria preferentially populate V islands versus Ti or Al substrata. In the case of the biphasic Ti6Al4V alloy, the bacteria tend to adhere to V-rich, mixed phase regions and phase boundaries. These findings demonstrate that enhanced and preferential adhesion of S. epidermidis (RP12) occurs on V surfaces in Ti-Al-V metal systems and suggest that bacterial interactions are influenced by surface oxide composition.

Alloys

Material-tissue interfaces: the role of surface properties and processes.

The introduction of a foreign material into living tissue--intentionally as in biomedical applications (implants, protheses, drugs) or unintentionally as when minerals or fibers are inhaled--results in the creation of interfaces between the material and the surrounding tissue. This article identifies and discusses the possible role of material surface properties and molecular processes occurring at such interfaces. For kinetic and thermodynamic reasons, surfaces are different from the corresponding bulk of the material, and contain reactive (unsaturated) bonds, which in turn lead to the formation of surface reactive layers (e.g., surface oxides on metals) and adsorbed contamination layers. The encounter with the biological environment leads to further surface reactions modifying the surface, and to the adsorption of water, ions, and biomolecules, which are continuously exchanged. The exact nature of the dynamic, adsorbed water, ions, and biomolecule coating in turn influences the behavior of cells approaching the material surface, and hence the tissue response.

Animals

Preparation of ultra-thin oxide windows on titanium for TEM analysis.

Using submerged jet electropolishing, extremely thin (less than 10 nm), continuous, thermal oxide "windows" have been prepared on polycrystalline titanium (Ti). The preparation technique is described in detail. It has allowed a systematic investigation of the structure of thermal surface oxide layers on Ti in the thickness range 6-40 nm, corresponding to oxidation temperatures 100-450 degrees C. Auger electron spectroscopy was used for oxide characterization and for depth profiling to determine oxide thickness. The thinnest oxides, less than 10 nm, are amorphous, morphologically homogeneous, and with essentially no contrast in the transmission electron microscopy (TEM) pictures. As the oxide thickness is increased up to 40 nm, a texture corresponding to the grain structure of the oxidized metal becomes gradually more visible. At the same time the oxide becomes increasingly more crystalline. The results are compared with previously published corresponding results for thicker anodic oxides on Ti.

Microscopy, Electron

Method for ultrastructural studies of the intact tissue-metal interface.

Samples were prepared for ultrastructural studies of the intact interface between metallic implants and tissue by transmission electron microscopy. The method is based on plastic embedding of implant and tissue and subsequent removal of the bulk metal by electrochemical dissolution (electropolishing), to facilitate preparation of ultrathin sections for transmission electron microscopy. Surface sensitive spectroscopy (Auger electron microscopy and X-ray photoemission spectroscopy) and transmission electron microscopy EDX results show that the method produces samples with an intact interface, containing the implant surface oxide and the adjacent tissue. Examples of application of the method on titanium, zirconium and aluminium implants in soft tissue are given.

Aluminum

Biomaterial and implant surfaces: on the role of cleanliness, contamination, and preparation procedures.

Material specificity in implant-tissue interactions derives primarily from the surface properties (chemical composition, microstructure, etc.) of the implant. This article addresses several questions related to implant and biomaterial surfaces: What is the status of real implant surfaces (composition, cleanliness, contamination, microstructure, etc.), and how does it vary with preparation procedures? Can the surface status be varied and analyzed in a controlled manner? How significant are surface status variations for in vivo function? And so on. We discuss clean surfaces, how they are contaminated, and how the contamination may affect the properties. We also discuss different preparation procedures, such as conventional machining, plasma treatment, and sterilization. Three important conclusions are drawn: (i) The surface status of a particular implant material may vary widely depending on its preparation and handling history. (ii) The surface status of implants is expected to be important for in vivo function, and should thus be controlled and standardized. (iii) It is usually not possible to predict how a change in surface status will affect the long-term, in vivo function of an implant.

Biocompatible Materials

Accelerated oxide growth on titanium implants during autoclaving caused by fluorine contamination.

Titanium implants were occasionally found to be strongly discoloured after autoclaving. The discolouration is shown to be due to an accelerated growth of the surface oxide that covers the implants. Oxide thicknesses up to 650 A have been observed, i.e. more than ten times thicker than on normal implants. By applying surface sensitive spectroscopies (SIMS and XPS or ESCA) it is also shown that these oxide films contain considerable amounts of fluorine, alkali metals and silicon. Screening tests with alkali-halide solutions identify fluorine as the impurity responsible for the accelerated oxide growth. Discolouration after autoclaving can be observed for fluorine contaminations down to the ppm level. In those cases where discolouration was observed in the clinical situation, the source of fluorine was the textile cloths in which the titanium implant storage box had been wrapped during the autoclaving procedure. The cloths contained residual Na2SiF6 which had been used as an additive to the rinsing water used in the last step of the cloth laundry procedure. Since the biocompatibility of titanium implants is closely related to their surface oxides it is advisable to avoid all sources of fluorine in the implant preparation procedures.

Color