PubMed Health⌕ Search

Biomedical subjects

B Krug

Publications and source records attributed to B Krug.

At least 19 recordsLinked to original sources

[Quality control of outpatient imaging examinations in North Rhine-Westphalia, part I].

PURPOSE: In the state of North-Rhine Westphalia (NRW), Germany, a survey was conducted on radiologic examinations ordered by general practitioners (GPs). Part I of this study aims to collect characteristic epidemiological data and to assess structural quality. MATERIALS AND METHODS: All GPs in NRW were asked to cooperate. Participating GPs filled out a questionnaire for each patient. The patients recorded the symptoms prompting the imaging examinations. The radiologists or other physicians performing the examinations were asked to provide the images and written reports and to complete a questionnaire. Two university radiologists documented the pertinent test data from the submitted images and written records. Independently of each other, five university radiologists anonymously reviewed the image quality of each examination using structured questionnaires. RESULTS: A total of 920 patients gave their informed consent and participated. Questionnaires from 787 patients, 852 GPs and 611 radiologists or other interpreting physicians as well as the complete survey data from 530 examinations were available. Of 1503 examinations, conventional radiography made up 52 %, sonography 17 %, computed tomography (CT) 13 % and magnetic resonance imaging (MRI) 5 %. Most indications involved the musculoskeletal (37 %) and respiratory systems (24 %). Physicians without board certification in radiology interpreted 1 % of the CT examinations, 26 % of the radiographic examinations and 71 % of the sonographic examinations. Of the 174 self-referrals, 1 % involved CT, 33 % conventional radiography and 66 % sonography. Written reports were available for 95 % of all 469 examinations performed by radiologists and 74 % of all 127 examinations conducted by non-radiologists. Only 44 % of the 23 sonographic studies were self-referrals by the patient's GP. On average, the radiographic techniques were acceptable in terms of diagnostic information and radiation hygiene. Conventional radiographs were better exposed when obtained by radiologists than by non-radiologists (p = 0.038). The delineation of anatomical structures was rated as good to acceptable for MRI, CT and conventional radiography, while the image quality was rated as diagnostically insufficient for sonography (p < 0.0001). The image quality of radiographic and sonographic examinations performed by radiologists was superior in comparison to examinations performed by physicians without board certification in radiology (p < 0.0001). CONCLUSION: Examination technique and imaging quality of MRI, CT and conventional radiography performed on outpatients were in an acceptable diagnostic range, whereas the quality of sonography was inadequate.

Family Practice↗

[Comparison of flat-panel radiography and computed radiography in urography].

PURPOSE: To evaluate the diagnostic value of digital flat-panel radiography in uroradiology the i. v. urograms of patients who had been examined with computed radiography and digital flat-panel radiography were compared regarding image quality. METHODS: 50 patients who underwent clinically indicated i. v. urography were examined with digital flat-panel radiography and computed radiography. In order to avoid unnecessary double exposure to X-rays, patients were examined either by flat-panel or computed radiography before injection of contrast media. Each further clinically indicated exposure after administration of contrast media was done by alternating the other examination technique. The digital images were compared by 4 radiologists regarding image quality for the detection of defined anatomic structures. RESULTS: Digital flat-panel radiography showed an image quality of the liver, spleen and both kidneys that was similar to computed radiography. The urinary tract, lumbar spine, pelvis and psoas muscle were significantly better visible on flat-panel radiography images. CONCLUSIONS: Compared to computed radiography there is no loss of image information by using digital flat-panel radiography in uroradiology. On the contrary, some anatomic structures on abdominal survey images show better image quality. In conclusion, digital flat-panel radiography has the potential to replace computed radiography in uroradiologic examinations.

Contrast Media↗

[Development of ultrasonography in a radiological university department from 1994 to 2001].

BACKGROUND: In 1994, 5 % of a total of 25 718 examinations and 7 % of all 4630 B-mode sonograms performed in the Radiology Department, University of Cologne was classified as not indicated. In light of these results, the health care policy guidelines for sonographic indications have been amended. PURPOSE: The aim of this study was to establish the current rate of non-indicated sonographic examinations performed in routine diagnostics by radiology departments at university hospitals, to determine the reasons for such over-diagnosis and identify which regulatory mechanisms can be implemented to prevent his. METHOD: We counted the number of 1) B-mode and 2) color-flow Doppler ultrasound imaging procedures carried out in patients who had had no change in symptoms within the previous 4 weeks or who were scheduled without reference to an existing sonogram (double examinations). 3) The reasons for over-diagnosis were analyzed. 4) The 1994 survey was repeated in 2000 with an identical protocol and 5) additionally, a modified survey of the diagnostic questions was conducted. RESULTS: 1) Out of 4,119 patients presenting for the first time to receive a B-mode sonogram, 443 prior sonograms (11 %), 305 CT scans (7 %) and 57 MRI scans (1 %) were documented. 2) Double sonograms were carried out in 6 % of the 1,118 patients presenting for the first time for color-flow Doppler ultrasounds and in 16 % of the 651 patients assigned to receive catheter angiographies with arterial color-flow Doppler. 2) 41 out of 55 (75 %) prior sonograms from non-university settings stated by 94 surgery patients were listed in the medical records. 36 out of 43 (84 %) prior sonograms from the university hospital were repeated in the same patients despite the fact that the medical report with the findings was available. None of the 48 sonograms indicated to confirm a plausible finding yielded any information that was additionally relevant to therapy. 4) In the period April - June, 2000, 12 % of all 15,921 tests and interventions, 26 % of 3,569 B-mode sonograms and 58 % of 1,033 abdominal sonograms performed in adults were classified as having not been indicated. 5) Staging and follow-up were stated as the most common reasons that a sonography was carried out in 46 % of the 1,017 adults who were given B-mode sonograms conducted from Jan - Mar, 2000 and comprised 62 % of the 410 sonograms classified as not or probably not medically indicated. CONCLUSION: The results showed that a multidisciplinary consensus was required to establish the diagnostic value of sonographic procedures. Therefore, this research group drafted a hospital-internal interdisciplinary guideline for "abdominal transcutaneous B-mode sonography in oncological questions".

Diagnostic Imaging↗

Whole-body positron emission tomography using 18F-fluorodeoxyglucose for initial staging of patients with Hodgkin's disease.

An accurate initial staging of patients with Hodgkin's disease (HD) is important for the evaluation of clinical stage and risk factors, which are crucial for the choice of an appropriate treatment. 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) is useful for detecting active tumor tissue in patients with lymphoproliferative diseases and may contribute to conventional staging methods in patients with HD. Twenty-two patients who presented with newly diagnosed HD underwent conventional staging methods including computed tomography (CT) as well as FDG PET. Lesions apparent in FDG PET and CT were correlated to each other. Seventy-seven lesions were observed either in PET or CT or in both. In 48 (62%) lesions PET and CT were both positive. In 20 (26%) sites, PET was positive and CT negative. Of 22 patients (18%) 4 were upstaged due to these positive PET findings, and as a result one patient received a different therapeutic regimen. PET failed to detect nine (12%) CT-positive sites in six patients. Statistically, these data are reflected by a sensitivity for PET and CT of 88% and 74%, respectively. Specificity of both imaging modalities was 100%. PET can contribute valuable information as an additional staging examination and led to an upstaging in some patients with primary HD. However, PET should not be used as the only imaging modality as it failed to detect CT-positive, active tumor regions in some cases.

Adult↗

Age related signal decrease in functional magnetic resonance imaging during motor stimulation in humans.

Right handed healthy volunteers underwent functional magnetic resonance imaging (fMRI) examinations on a 1.5 Tesla MRI-scanner (Gyroscan ACS NT; Philips, Best, NL). Blood oxygen level dependent (BOLD) images were obtained using a three dimensional multi-shot echo planar imaging sequence employing a shifted echo technique (Principles of echo shifting with a train of observations). Finger tapping of the right hand was used as a task for motor stimulation. A total of 86 subjects was included into statistical analysis. Absolute and relative signal differences and cluster sizes of activation for the left motor cortex were obtained. In addition, Z-score, pooled Z-score and cross correlation activation maps were calculated and matched with high resolution anatomic images. A significant decrease with age could be detected for absolute and relative signal intensity differences for the whole group and for the male subgroup. Correlation analysis for the female subgroup also bore negative albeit non-significant correlation coefficients. An age-related decline of BOLD-contrast can be assumed to explain signal decrease. This age-related effect should be considered in clinical fMRI applications.

Adult↗

Cricopharyngeal muscle hypertrophy associated with florid myositis.

Hypertrophy of the cricopharyngeal muscle is a serious clinical condition that can cause severe dysphagic symptoms, including prolonged deglutition and postdeglutitive aspiration. Although the therapeutical concepts are well established, the pathogenic mechanism of cricopharyngeal hypertrophy remains unclear. We present a patient with a ten-year history of progressive dysphagia. The neurological and MRI findings were normal. However, videocineradiography showed severe hypertrophy of the cricopharyngeal muscle. This condition was first treated by injections of botulinum toxin, which did not alleviate the symptoms. Next, myotomy and muscle biopsy were performed. Histological evaluation disclosed lymphoplasmacellular florid myositis, single-fiber atrophy, and muscle fiber necrosis with phagocytosis. There were no signs of inclusion body myositis or oculopharyngeal muscular dystrophy. Our finding of severe cricopharyngeal muscle hypertrophy associated with myositis has been published previously (n = 34). The study presented here shows cricopharyngeal dysphagia associated with various systemic diseases, including motor neuron disease, general granulomatous disease, dermatomyositis, or inclusion body myositis. Isolated changes of the cricopharyngeal muscle were described in 65% of the cases.

Aged↗

Image quality of digital chest X-rays: wet versus dry laser printers.

The aim of this study was to compare the image quality of digital chest x-rays (Thoravision) obtained with 2 "wet" laser imagers of different matrix sizes and a "dry" system. Fifty chest x-rays in 2 planes were printed out in normal (100%) and reduced (61%) format using 3 different systems: 2 "wet" laser imagers (Agfa Matrix LR 3300, 4256 x 5174 pixels, 315 dpi; Agfa Scopix LR 5200, 8512 x 10348 pixels, 630 dpi), and one "dry" system (Agfa Drystar 3000,4352 x 5295 pixels, 330 dpi). All tests yielded normal findings. Anonymous images were evaluated by 4 independent reviewers on record forms rating the detectability of predefined anatomic structures. When the image quality of diagnosis-relevant, anatomic structures was evaluated on digital chest x-rays reproduced in normal and reduced format, the wet laser imagers did not show significant advantages over the dry system, Agfa Drystar 3000. The Agfa Drystar 3000 system is a feasible alternative for reproducing digital images, particularly for decentralized archives.

Adult↗

Functional magnetic resonance imaging of human pontine auditory pathway.

The purpose of this study is to visualize brainstem auditory pathways by functional magnetic resonance imaging (fMRI). Eighteen healthy volunteers (age 28 to 42 years) with normal hearing function underwent fMRI examination on a 1.5 Tesla imaging system (Philips, Best, The Netherlands) with periodic click stimulation. Blood oxygen level dependent images were obtained using a three-dimensional EPI sequence with shifted echo technique (principles of echo shifting with a train of observations). Control scans without click stimulation were obtained in the identical setting. Cross correlation activation maps were calculated using a postprocessing tool (Philips). They were matched with anatomic slices of identical orientation and thickness. Five of 18 subjects were excluded because of motion artifacts. In 4/13 significant activation was observed at the root entry zone of the ipsilateral acoustic nerve corresponding to the cochlear nuclei. In 11/13 subjects, significant activation was found in the same slice contralaterally close to the floor of the 4th ventricle, corresponding to the expected region of the superior olivary nucleus. Activation of the rostral parts of the auditory pathway (inferior colliculus, medial geniculate body) was not found. In the absence of the stimulus no activation occurred in these structures. It was concluded that activation of the brainstem auditory pathways by click stimuli can be visualized by fMRI.

Acoustic Stimulation↗

Use of an image-guided navigation system in dental implant surgery in anatomically complex operation sites.

INTRODUCTION: Recent developments in computer assisted surgery have brought major improvements to maxillofacial surgery. Computer systems for intra-operative navigation have been introduced enabling the surgeon to locate the continually updated position of the instruments and the operation site on the patient's three-dimensional reconstructed image data set displayed on a monitor in the operating room. Complex surgical procedures can be performed according to the preoperative plan based on CT and/or MRI data minimizing surgical risks and optimizing clinical results. Nowadays computer-assisted-surgery has also proved effective in dental implantology. AIM: The objective of this study was to compare the accuracy of conventional and computer-assisted dental implantation planning and surgery. Analyzing our early experiences, we aimed to evaluate the benefit from utilising computer assisted surgery (CAS). PATIENTS: Five patients were treated with the aid of CAS, a total of 18 dental implants being placed. Only difficult operation sites, e.g. following bone augmentation or anatomically malformed jaws were included in this study. METHOD: An infra-red light based navigation system (Vector Vision 2, BrainLAB, Munich, Germany) including a three-dimensional planning approach for maxillofacial surgery was used. Placement of dental implants in the maxilla included direct visualization when drilling the implant socket according to the axis previously planned on radiographs and CT scans. RESULTS: In two cases the conventionally planned implant location had to be changed due to insufficient bone being available. With four implants, it proved possible to insert longer fixtures after the CAS system had evaluated all parameters of the surgical region. In one case a shorter implant was installed due to insufficient bone at the designated location. CONCLUSION: The use of an image-guided navigation system provides a valuable tool in implant dentistry and proved superior to conventional implant surgery especially in difficult anatomical regions.

Alveolar Ridge Augmentation↗

Image guided surgical navigation for removal of foreign bodies in the head and neck.

INTRODUCTION: The removal of foreign bodies in the head and neck area is often a surgical challenge due to a combination of difficult access and a close anatomical relationship of the foreign body to vital structures. Recent developments in computer-assisted surgery (CAS) have brought major improvements to the operating rooms for maxillofacial surgeons. The purpose of this paper is to report our experience in computer assisted removal of foreign bodies from the head and neck area, based on various clinical cases. PATIENTS: Computer assisted removal of foreign bodies from the head and neck area was performed in 11 patients. Three patients sustained gun shot wounds with remaining projectiles or fragments in the soft tissue. In six cases, objects related to a preceding surgical intervention were removed. Two patients presented with dislocated teeth in the facial or cervical soft tissues after 3rd molar surgery. METHOD: For surgical planning and intra-operative navigation, a computer based image guided surgery system (VectorVision(2), BrainLab) was used. RESULTS: In 10 of 11 cases the foreign bodies could be removed without major complications by a minimal invasive manner. More than 40 % of surgery time could be saved compared to similar interventions operated upon using conventional methods. CONCLUSION: In our opinion, the use of a computer based image guided surgical system is of great benefit when removing foreign bodies from the head and neck area. The minimally invasive access helps to prevent major complications such as injury to vital structures and allows a quicker operation.

Adolescent↗

[Comparison of digital selenium radiography with an analog screen-film system in the diagnostic process of pneumoconiosis according to ILO classification].

UNLABELLED: Comparison of digital selenium radiography with an analog screen-film system in the diagnostic process of pneumoconiosis according to ILO classification. PURPOSE: The aim of the study was to determine the diagnostic value of digital selenium radiography in patients with pneumoconiosis. For this purpose chest x-rays by digital selenium radiography and analog screen-film system were compared according to the ILO classification of pneumoconiosis. METHOD: After approval of the study by the local ethic commission and the Federal German Office for Radiation Protection 50 patients were subjected to x-rays by digital selenium radiography (Thoravision; Philips Medical Systems, Hamburg, Germany) and analog screen-film system of the same day within the scope of an industrial medicine preventive checkup. Four investigators rated the chest x-rays according to the ILO classification of pneumoconiosis. RESULTS: The findings demonstrated by chest x-rays according to ILO classification were rated similar by digital selenium radiography and analog screen film systems. Image quality of the digital pictures was rated significantly better. CONCLUSION: The use of digital selenium radiography in evaluating chest x-rays according to the ILO classification does not result in over- or underestimation of pulmonary pathologies. Hence, in the diagnosis of pneumoconiosis, digital selenium radiography can replace the tested analog screen-film system.

Adult↗

[Artifacts in MR Imaging due to ventilation tubes].

UNLABELLED: Artifacts in MR Imaging due to ventilation tubes. PURPOSE: MR examinations may be necessary in patients under artificial ventilation. Possible imaging artifacts originating from ventilation tubing made from silicone are demonstrated. MATERIALS AND METHODS: In silicone carbohydrate residues are bound to silicon atoms. In silicone gels they give strong signals in MR imaging. MR signals from more solid silicone rubber are only possible if the carbohydrate residues in the molecular chain retain a sufficient mobility. To investigate whether silicone tubes give signals in MR images, different tubes for ventilation made from silicone and polyester were examined at 1.5 T (Gyroscan ACS NT, Powertrak 6000 gradients) with MR imaging and spectroscopy (MRS: PRESS, TE = 20 ms; relaxation time measurements: MIXED sequence; imaging: FFE [gradient echo] and TSE sequences). RESULTS: Using short TE (</= 4 ms), tubes and sockets made from silicone could be imaged with FFE and SE sequences. An SE sequence with a short TE = 4 ms provided a sufficient signal intensity to depict the tube clearly besides brain tissue of a volunteer. When foldover occurred, the signal of the tube was projected onto the brain tissue. MR spectra confirmed that the image signal originated from the carbohydrate residues of the silicone molecule chains, not from residual water in the tube wall material. T(2) determinations indicate a multiexponential relaxation including a large component with a short TE (</= 15 ms). Tubes made from a polyester elastomere did not show up in MR images. CONCLUSION: In MR images acquired with very short echo times silicone in ventilation tubes may produce significant artifacts.

Adult↗

Detection of porcine bone lesions and fissures: comparing digital selenium, digital luminescence, and analog film-screen radiography.

OBJECTIVE: The purpose of our study was to compare the diagnostic performance of a digital selenium detector (Thoravision) with that of analog film-screen systems and digital luminescence radiography in skeletal radiography for the detection of fissures and lesions in porcine bones. MATERIALS AND METHODS: One hundred bones taken from domestic pigs (50 ribs and 50 femurs) were divided into two equal groups. Fissures and bone lesions were created in 50 bones and 50 served as controls. The bones were examined using film-screen systems, digital luminescence radiography, and digital selenium radiography at various doses. Digital selenium radiography exposure values were adapted to the image geometry differing from the reference methods with a detector focus distance of 2.15 m. Four radiologists independently evaluated image quality and detectability of fissures and lesions on a five-point scale of confidence. Statistical evaluation was based on receiver operating characteristic curve analysis. RESULTS: Fissures and bone lesions were detected most reliably using the mammography film-screen system, but the difference in the results of the analog and digital reference images did not achieve statistical significance. CONCLUSION: Compared with analog film-screen systems, the lower spatial resolution of the digital selenium and digital luminescence radiography systems does not affect detectability of fissures and bone lesions in porcine bone. Selenium is effective in skeletal radiography for detecting fissures and bone lesions. With digital selenium and digital luminescence radiography, the surface dose can be cut to half that required for 200-speed film-screen systems without losing any diagnostically relevant information.

Animals↗

Inadequacies of repeated radiological examinations in a university hospital.

PURPOSE: To establish why 16% of 1,045 patients undergoing abdominal and/or vascular surgery referred to the University Department of Radiology for a B-image sonogram reported that a US of the same regions of the body had been conducted during the previous 6 weeks without any changes in the clinical status. STATEMENT OF THE PROBLEM: Evaluation of the reasons for these superfluous examinations and analysis of the consequences that the US follow-up examinations implied for the patient. MATERIAL AND METHODS: One senior resident radiologist and one senior resident surgeon reviewed the medical records of the patients reporting previous examinations and examinations scheduled at the time of the questioning of the patients. RESULTS: One hundred and eight (63%) of the 171 medical records were available. Data on previous examinations mentioned in the report forms were incorrect in 14 cases (13%). Therefore, further evaluations were based on 94 patients. Ten (8%) out of 121 sonograms, 4 (10%) out of 40 CT and 2 (20%) out of 10 MR investigations documented in the medical records had not been mentioned by the patients. As many as 41 (75%) of the 55 preliminary sonograms performed by general practitioners and specialists in private practice were not documented in the medical records. Even though records existed of clinically plausible findings, 36 (84%) of the 43 preliminary US investigations performed by doctors in the University Hospital were repeated to verify the diagnosis without any further diagnostic benefit. CONCLUSION: A cross-speciality consensus over the diagnostic value of B-image sonography and management of the findings obtained is of paramount importance.

Abdomen↗

[Treatment outcomes in primary and secondary retroperitoneal fibrosis].

Retroperitoneal fibrosis (RPF) is an uncommon inflammatory disease of the retroperitoneum leading to extensive fibrosis with consecutive obstruction of adjacent organs, namely the ureters. Since no consensus on the standard therapy exists, aim of the current study was to evaluate the outcome of 39 patients with RPF. Between 1986 and 1997 39 cases of RPF were diagnosed: 21 cases had primary RPF and 18 patients had secondary RPF after aortofemoral graft (n = 13), radiation (n = 2), or prior retroperitoneal surgery (n = 2). 21 patients demonstrated unilateral and 16 cases had bilateral hydronephrosis, in 2 patients no dilatation was observed. In 28 cases (n = 12 primary RPF, n = 16 secondary RPF) initial management consisted of DJ-stent placement, whereas in 11 cases (n = 9 primary RPF, n = 2 secondary RPF) percutaneous nephrostomy had to be placed. All patients received oral immunosuppressive agents (prednisolone 1 mg/kg, azathioprine 1 mg/kg/day) for 3 months before reevaluation was performed. In case of complete remission, immunosuppressive medication was continued for another 3 months, in case of stable disease or progression surgery was performed. In 26 cases (n = 15 primary RPF, n = 11 secondary RPF) ureterolysis with intraperitoneal displacement and omental wrapping was performed. 3 patients demonstrated complete remission after oral prednisolone/azathioprine; in 2 cases RPF presented as pelvic mass and was resected followed by immunosuppressive therapy, in another 2 cases bilateral ileal replacement of the ureters had to be performed and 4 cases remained on DJ-stents and nephrostomy, resp. Postoperatively, all patients with primary RPF were continued on immunsuppressive medication for another 3 months. After a follow-up of 6 to 120 months only 3 patients developed a retroperitoneal recurrence and were treated by unilateral nephrectomy or DJ stent placement (n = 2). Our data suggest that the combination of both immunosuppressive medication and surgical management results in an excellent longterm outcome in idiopathic retroperitoneal fibrosis with a recurrence rate of only 8%. Combination therapy should be considered as therapeutic option early in the course of the disease. Primary reconstructive surgery appears to be the most promising approach in secondary retroperitoneal fibrosis with a recurrence rate of only 5%; short external compression of the ureter might be managed by endoluminal balloon dilatation.

Adult↗