PubMed Health⌕ Search

Biomedical subjects

B L Bacon

Publications and source records attributed to B L Bacon.

3 recordsLinked to original sources

Predictive, error-compensating kinetic method for enzymatic quantification of creatinine in serum.

Here we describe an error-compensating kinetic-based method for the enzymatic quantification of creatinine in serum. The method, which has a large linear range and very low dependency on experimental variables that influence enzyme activity, is based on the use of creatinine amidohydrolase in a four-step coupled reaction sequence to generate a product that is monitored photometrically. We collected data for absorbance vs time during two to four half-lives of each reaction and fit a first-order model to the data to compute the total absorbance change that would be measured if the reaction were monitored to completion. Computed values of absorbance change agreed well with measured values and varied linearly with creatinine concentration in the sample throughout the range examined: 44 to 1326 mumol/L. A twofold change in enzyme activity in the final reaction mixture (3.3 to 6.6 kU/L) produced changes of only 12% and 4% for creatinine concentrations of 44 and 353 mumol/L, respectively. Results (y) for 39 serum samples that contained creatinine concentrations between 20 and 1800 mumol/L agreed well with liquid-chromatographic results (x), yielding linear least-squares statistics of y = (1.03 +/- 0.01) x + (5 +/- 5) mumol/L (r = 0.995, Sy.x = 37 mumol/L). We conclude that the predictive kinetic approach is a robust method for the quantification of creatinine in serum.

Chromatography, High Pressure Liquid↗

Kinetic study of the Jaffé reaction for quantifying creatinine in serum: 2. Evaluation of buffered reagent and comparison of different data-processing options.

Here we describe the evaluation of several data-processing options for the kinetic determination of creatinine by use of the Jaffé reaction. Data-processing options evaluated include initial-rate, two-point fixed-time, rate at t = k-1, and multipoint curve-fitting predictive methods. We evaluated these options for a buffered formulation of the Jaffé reagent and studied the effects of potential interferents, including glucose, acetoacetate, bilirubin, and albumin, on each option. To reduce effects of bilirubin, we evaluated the inclusion of a preoxidation step with ferricyanide. All the data-processing options gave good precision and linearity between the measurement objective and creatinine concentration. However, differences between slopes of calibration plots in aqueous and serum matrices ranged from a high of +60% for the two-point, fixed-time method to a low of -11% for the curve-fitting, predictive method. Standard additions of creatinine to sera were quantified reliably (yielding 96% to 102% of target values) by the predictive method and less reliably (62% to 102%) by the other methods. We conclude that the predictive method has the potential to yield the most reliable results for creatinine.

Acetoacetates↗

Kinetic study of the Jaffé reaction for quantifying creatinine in serum: 1. Alkalinity controlled with NaOH.

We studied the kinetic behavior of the reaction of alkaline picrate and creatinine and evaluated a nonlinear curve-fitting method for quantifying creatinine in serum. Using a 3 X 3 factorial experimental design, we evaluated interactive effects among temperature and concentrations of creatinine, picrate, and NaOH. We found no evidence of interference by glucose or unconjugated bilirubin; the effects of the acetoacetate reaction, which is fast, are easily compensated by the curve-fitting method. The reaction with human serum albumin is very complex, but its effects are compensated by the curve-fitting method and by preparing standards containing 50 g of albumin per liter. Calibration plots are linear under a wide variety of conditions for both aqueous standards and standard additions of creatinine to pooled serum. Reproducibility studies with standards containing creatinine at 2, 10, and 20 mg/L yielded relative standard deviations (RSD) of 8.2, 2.5, and 1.3%, corresponding to absolute variations of 0.16, 0.25, and 0.26 mg/L. The average SD for 17 sera containing creatinine at 15-50 mg/L was 0.7 mg/L. The averages of ratios (as percent) of determined vs expected concentrations in 17 sera with added creatinine (7.27 mg/L) were 97.8% for aqueous standards, 99.9% for standards with added albumin.

Acetoacetates↗