PubMed Health⌕ Search

Biomedical subjects

B L Jing

Publications and source records attributed to B L Jing.

6 recordsLinked to original sources

Electron beam tomography with three-dimensional reconstruction in the diagnosis of aortic diseases.

BACKGROUND: This study was performed to evaluate the protocols of electron beam tomographic angiography and three-dimensional reconstruction for assessing the diagnostic value of aortic diseases. METHODS EXPERIMENTAL DESIGN: Retrospective and comparative study. SETTINGS: University hospital. PATIENTS: Between 1996 and 1998, 189 cases who underwent electron beam tomographic angiography and diagnosed with aortic diseases were analyzed retrospectively. The results were compared with surgical and pathological findings in 68 cases. Electron beam tomographic angiography was used single-slice-scanning with ECG-triggering for screening of the thoracic aorta, continuous-volume-scanning, permitted by continuous X-ray exposure with table incremention, was performed for the abdominal aorta scanning without ECG-triggering. Three-dimensional reconstructions were performed with shaded-surface display, multiplanar reformatting and/or maximum intensity projection methods. RESULTS: Electron beam tomography angiography with ECG-triggered sections of single-slice-scanning improved the image quality of the ascending aorta without motion artifacts. Continuous-volume-scanning was suitable for screening of the abdominal aorta because of minimizing exposure time (10-14 sec) and saving contrast media (total contrast material of 45.5+/-6.6 ml was needed). One hundred eighty-nine cases were diagnosed with aortic dissection (97 cases), aortic aneurysm (26 cases), pseudoaneurysm (8 cases), Marfan's syndrome (39 cases), Takayasu's arteritis (5 cases) and congenital aortic malformations (14 cases). Electron beam tomography results were compared with the findings of surgery (as gold standard) in 68 cases, the diagnostic accuracy was 97% (2 cases with aortic aneurysm were erroneously diagnosed with pseudoaneurysm). CONCLUSIONS: Electrocardiographically triggered, contrast-enhanced electron beam tomography is feasible for the diagnosis of all kinds of aortic diseases, with excellent three-dimensional images competitive in quality with conventional selective aortic angiography or digital subtraction angiography.

Adolescent↗

Coronary artery stenoses: a phantom study using contrast enhanced three-dimensional electron beam tomography.

This paper evaluated the accuracy of electron beam tomographic angiography (EBA) with conventional coronary arteriography (CCA) using four graded artificial stenoses in a postmortem swine coronary phantom model. The sensitivity, specificity, and accuracy of EBA for diagnosing significant stenosis (> or =50% stenosis) were 94.3%, 96.7%, and 95.8%, respectively. The diagnostic accuracy of EBA had no significant difference with CCA (chi(2)=0.0162; P>.05). EBA three-dimensional (3D) procedures had high interobserver reproducibility (k=.92-.95, P>.05). Maximum intensity projection (MIP) was the most sensitive and curved planar reformation (CPR) was the most accurate 3D procedure for quantitatively identifying coronary stenosis. EBA yields promising results concerning the visualization of coronary artery stenosis with high accuracy for stenoses >50%.

Animals↗

Evaluation of coronary artery bypass graft patency using three-dimensional reconstruction and flow study on electron beam tomography.

OBJECTIVES: To establish and evaluate two protocols for the noninvasive visualization and assessment of coronary artery bypass graft (CABG) patency on electron beam tomography (EBT). METHODS: Two hundred fourteen consecutive patients who underwent CABG surgery were scanned using both EBT angiography with three-dimensional reconstruction and EBT flow study with time-density curve analysis. RESULTS: There was a total of 589 CABGs evaluated in this study (10 grafts were excluded because of artifacts); 133 (98.5%) of 135 arterial grafts were patent, 345 (77.7%) of 444 saphenous vein grafts were patent. Within 5 years or 5-10 years after surgery, arterial graft patency exceeded venous graft patency (p<0.001). Three-dimensional EBT angiography achieved higher sensitivity, specificity, and accuracy (97.7%, 94.1%, and 96.7%, respectively) than EBT flow study (88.4%, 82.4%, and 85.2%, respectively) for evaluating occlusion or patency of CABGs. The intragraft flow of patent arterial and venous grafts were 4.9+/-2.2 ml/min/g and 6.9+/-2.8 ml/min/g, respectively (p<0.001). CONCLUSION: The combination of EBT three-dimensional reconstruction and flow study can be more effectively performed in the assessment of CABG anatomy and quantification of patent CABG flow.

Coronary Angiography↗