PubMed Health⌕ Search

Biomedical subjects

B L Karger

Publications and source records attributed to B L Karger.

At least 37 records · Page 2Linked to original sources

Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable linear polyacrylamide solutions.

Long, accurate reads are an important factor for high-throughput de novo DNA sequencing. In previous work from this laboratory, a separation matrix of high-weight-average molecular mass (HMM) linear polyacrylamide (LPA) at a concentration of 2% (w/w) was used to separate 1000 bases of DNA sequence in 80 min with an accuracy close to 97% (Carrilho, E.; et al. Anal. Chem. 1996, 68, 3305-3313). In the present work, significantly improved speed and sequencing accuracy have been achieved by further optimization of factors affecting electrophoretic separation and data processing. A replaceable matrix containing a mixture of 2.0% (w/w) HMM (9 MDa) and 0.5% (w/w) low-weight-average molecular mass (50 kDa) LPA was employed to enhance the separation of DNA sequencing fragments in CE. Experimental conditions, such as electric field strength and column temperature, as well as internal diameter of the capillary column, have been optimized for this mixed separation matrix. Under these conditions, in combination with energy-transfer (BigDye) dye-labeled primers for high signal-to-noise ratio and a newly developed expert system for base calling, the electrophoretic separation of 1000 DNA sequencing fragments of both standard (M13mp18) and cloned single-stranded templates from human chromosome 17 could be routinely achieved in less than 55 min, with a base-calling accuracy between 98 and 99%. Identical read length, accuracy, and migration time were achieved in more than 300 consecutive runs in a single column.

Acrylic Resins↗

A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. A. Development of the cleanup protocol.

A method for the cleanup of Sanger DNA sequencing reaction products for capillary electrophoresis analysis with replaceable polymer solutions has been developed. A poly(ether sulfone) ultrafiltration membrane pretreated with linear polyacrylamide was first used to remove template DNA from the sequencing samples. Then, gel filtration in a spin column format (two columns per sample) was employed to decrease the concentration of salts below 10 microM in the sample solution. The method was very reproducible and increased the injected amount of the sequencing fragments 10-50-fold compared to traditional cleanup protocols. Using M13mp18 as template, the resulting cleaned-up single DNA sequencing fragments could routinely be separated to more than 1000 bases with a base-calling accuracy of at least 99% for 800 bases. The method is simple and universal and can be easily automated. In the following paper, a systematic study to determine quantitatively the effects of the sample solution components such as high-mobility ions (e.g., chloride and dideoxynucleotides) and template DNA on the injected amount and separation efficiency of the sequencing fragments is presented.

Base Sequence↗

A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. B. Quantitative determination of the role of sample matrix components on sequencing analysis.

In the previous paper, a sample cleanup procedure for DNA sequencing reaction products was developed, in which template DNA was removed by ultrafiltration and the total concentration of salts (chloride and di- and deoxynucleotides) was decreased below 10 microM using gel filtration. In this paper, a quantitative study of the effects of these sample solution components on the injected amount and separation efficiency of the sequencing fragments in capillary electrophoresis is presented. The presence of chloride and deoxynucleotides in a total concentration above 10 microM in the sample solution significantly decreased the amount of DNA sequencing fragments injected into the capillary column. However, the separation efficiency was not affected upon increasing the amount of salt. On the other hand, in the presence of only 0.1 microgram of template in the sample (one-third of the lowest quantity recommended in cycle sequencing) and at very low chloride concentration (approximately 5 microM), the separation efficiency decreased by 70%, and the injected amount of DNA sequencing fragments was 40% lower compared to the sample cleaned by the new purification method. The deleterious effect of template DNA on the separation of sequencing fragments was suppressed in the presence of salt in a concentration above 100 microM in the sample solution. Separately, it was found that both the electric field strength and duration of injection affected the resolution of DNA sequencing fragments when the cleaned up sample solution was used. Separation efficiencies of 15 x 10(6) theoretical plates/m were achieved when the sample was loaded at low electric field, e.g., 25 V/cm for 80 s or less. The results demonstrate that the sample solution components (chloride, deoxynucleotides, template DNA) and injection conditions must be controlled to achieve high performance and rugged DNA sequencing analysis.

Chlorides↗

Simultaneous measurement of nineteen binding constants of peptides to vancomycin using affinity capillary electrophoresis-mass spectrometry.

On-line affinity capillary electrophoresis-electrospray ionization-mass spectrometry (ACE-MS) was used for the simultaneous measurement of multiple binding constants of an all-D-tetrapeptide library to the model receptor, vancomycin. Determination of Kd values for the 19 peptides of the form Fmoc-DXYA is demonstrated. The data are compared with the results obtained for individual compounds using ACE-UV, and good correlation between the two detection methods is shown. Simultaneous determination of multiple Kd values by ACE-MS is achieved in one set of experiments, whereas only one Kd value can be obtained by ACE-UV during the same time. ACE-MS measures multiple binding constants in solution in a fast and reliable manner using femtomole amounts of samples.

Binding, Competitive↗

Characterization of high molecular mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis.

In a previous paper, a 2% w/w replaceable high molecular mass linear polyacrylamide solution (high molecular mass LPA) was used to achieve long read-lengths for DNA sequencing by capillary electrophoresis (E. Carrilho et al., Anal. Chem. 1996, 68, 3305-3313). In that work, the polymer was prepared by polymerization in water at 6% w/w, followed by dilution to 2% w/w. In this study, an improved method for preparation of high molecular mass LPA was developed, based on inverse emulsion polymerization. With this polymerization procedure, the LPA results in a molecular mass of approximately 9 MDa, with characteristics of a fine powder of high purity and practically unlimited shelf life. Using size exclusion chromatography (SEC) and viscosity measurements to characterize the polymer, good batch-to-batch reproducibility was found. It was observed that the viscous polymer solutions made from these high molecular mass polymers require careful preparation and handling because the method of dissolution could affect the molecular mass distribution and the resultant separation of DNA components. Solutions containing 2% w/w of LPA made by emulsion polymerization were simple to prepare, resulting in excellent performance as a replaceable matrix for DNA sequencing by capillary electrophoresis. The viscosity of the polymer decreased exponentially when pressure was applied, allowing easy replacement from a capillary using a syringe. With a properly prepared matrix, a read-length of more than 1000 bases in 80 min with an accuracy better than 97%, and better than 99% for the first 800 bases, could be achieved.

Acrylic Resins↗

Analysis of 1-aminopyrene-3,6,8-trisulfonate-derivatized oligosaccharides by capillary electrophoresis with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), has been used for structure characterization of 1-aminopyrene-3,6,8-trisulfonate (APTS)-derivatized oligosaccharides previously separated by capillary electrophoresis (CE). The resolved components were first isolated by employing an automated high-resolution fraction collector. Using on-probe sample cleanup with a cation-exchange resin and a matrix mixture of (1:1) 6-hydroxypicolinic acid and 3-hydroxypicolinic acid, APTS-labeled oligosaccharides were successfully detected by MALDI-TOF MS in the negative ionization mode. Each APTS-labeled oligosaccharide produced single [M-H]-1 peaks. Detection limits for standard APTS-derivatized oligosaccharide (maltoheptaose) were down to 30 fmol. APTS labeled maltooligosaccharides and various standard carbohydrates were separated and collected by CE, followed by molecular weight determination with MALDI-TOF MS. The mass spectral characterization enhances the power of the CE analysis of oligosaccharides.

Carbohydrate Sequence↗

Automated microanalysis using magnetic beads with commercial capillary electrophoretic instrumentation.

The potential of a new microanalytical method using magnetic beads (MBs) and commercial capillary electrophoresis (CE) instrumentation for performing enzymatic and inhibition assays, as well as for analysis of biological molecules such as antigens, substrates, etc., has been explored. A small quantity of magnetic beads containing immobilized biomolecules was injected into a neutral hydrophilic-coated fused-silica capillary. The short plug (2-3 mm) of beads was held fixed by a magnet placed in the cartridge of the CE system, without the use of frits. The beads could be replaced after each run, eliminating the need to regenerate the solid support. Two protocols were used for analysis: sequential injection (SI) and SI followed by isotachophoretic (ITP) focusing. Alkaline phosphatase (AP) and HIV-protease were used to demonstrate the SI procedure for enzymatic and inhibition assays. The second protocol, SI/ITP, was employed to quantitate an antigen (mouse mAB) using antibodies (sheep IgG towards mouse AB) immobilized on the beads. The MB-CE method, requiring only femtomole (fmol) quantities of material, can potentially be employed in diagnostic and forensic assays, kinetic studies and searching for inhibitors, ligands, receptors, etc.

Alkaline Phosphatase↗

Capillary electrophoresis for the detection of known point mutations by single-nucleotide primer extension and laser-induced fluorescence detection.

Capillary electrophoresis (CE) with laser-induced fluorescence (LIF) was used to detect known point mutations using the method of single-nucleotide primer extension (SNuPE). Three different point mutations in human mitochondrial DNA associated with Leber's hereditary optic neuropathy (LHON) were detected by annealing a primer immediately 5' to the mutation on the template and extending the primer by one fluorescently labeled dideoxy terminator complementary to the mutation. By using two or more differently labeled terminators, both the mutant and wild type could be simultaneously detected. The advantages of using CE-LIF for detecting SNuPE reactions include speed and ease of analysis, absence of radioactivity, and potential for automation.

Base Sequence↗

Microscale epitope mapping by affinity capillary electrophoresis-mass spectrometry.

Using beta-endorphin as a model system, a new microscale solution-based approach for linear epitope mapping based on affinity capillary electrophoresis-mass spectrometry (ACE-MS) is demonstrated. Tryptic peptides are separated in a neutral coated capillary and monitored by ultraviolet absorbance and electrospray mass spectrometry. Then, following injection of the peptide digest mixture, anti-beta-endorphin antibody is injected. The peptide, which binds to the antibody, is captured and disappears from its migration time. Following this subtraction-screening procedure, the binding of the individually synthesized or isolated immunoreactive peptide is examined by the ACE-MS procedure to confirm that the epitope resides on the peptide. A series of truncated peptides can then be made and the precise epitope determined by ACE-MS. The method utilizes low femtomole amounts of antibody and peptide digest per run and is rapid and easily automatable.

Antibodies↗

Mutational spectrometry without phenotypic selection: human mitochondrial DNA.

By first separating mutant from nonmutant DNA sequences on the basis of their melting temperatures and then increasing the number of copies by high-fidelity DNA amplification, we have developed a method that allows observation of point mutations in biological samples at fractions at or above 10-6. Using this method, we have observed the hotspot point mutations that lie in 100 base pairs of the mitochondrial genome in samples of cultured cells and human tissues. To date, 19 mutants have been isolated, their fractions ranging from 4x10-4 down to the limit of detection. We performed specific tests to determine if the observed signals were artefacts arising from contamination, polymerase errors during PCR or DNA adducts created during the procedure. We also tested the possibilities that DNA replication mismatch intermediates, or endogenous DNA adducts that were originally present in the cells, were included with true mutants in our separation steps and converted to mutants during PCR. We show that while most of the mutants behave as double-stranded point mutants in the cells, some appear to arise at least in part from mismatch intermediates or cellular DNA adducts. This technology is therefore sufficient for the observation of the spectrum of point mutations in human mitochondrial DNA and is a tool for discovering the primary causes of these mutations.

Artifacts↗

Multichannel microchip electrospray mass spectrometry.

Microfabricated multiple-channel glass chips were successfully interfaced to an electrospray ionization mass spectrometer (ESI-MS). The microchip device was fabricated by standard photolithographic, wet chemical etching, and thermal bonding procedures. A high voltage was applied individually from each buffer reservoir for spraying sample sequentially from each channel. With the sampling orifice of the MS grounded, it was found that a liquid flow of 100-200 nL/min was necessary to maintain a stable electrospray. The detection limit of the microchip MS experiment for myoglobin was found to be lower than 6 x 10(-8) M. Samples in 75% methanol were successfully analyzed with good sensitivity, as were aqueous samples. The parallel mutliple-channel microchip system allowed ESI-MS analysis of different samples of standard peptides and proteins in one chip.

Mass Spectrometry↗

Integrated multichannel microchip electrospray ionization mass spectrometry: analysis of peptides from on-chip tryptic digestion of melittin.

In continuation of our work to develop an integrated multichannel microchip interfaced to electrospray mass spectrometry (ESI-MS), this paper demonstrates one of several applications of this approach in monitoring tryptic digestion products. The multichannel microchip allowed integration of sample preparation onto the microchip to facilitate the analysis process. Melittin was selected as a model oligopeptide because it possesses a cluster of four adjacent basic residues which enable probing the site specificity of trypsin as a function of digest times. Reactions were performed on-chip in different wells for specific time periods and then analyzed by infusion from the microchip by ESI-MS, using leucine enkephalin as internal standard. The rate of formation and disappearance of the molecular ion and individual fragments was followed for a melittin to trypsin concentration ratio of 300:1. The results indicate the potential of integrating enzymatic reactions with multichannel microchip ESI-MS for automated optimization of reaction condition while consuming only small amounts of sample.

Amino Acid Sequence↗

A CE/ESI-MS interface for stable, low-flow operation.

A rugged, stable liquid sheath interfacing procedure for on-line CE/MS is described. This procedure combines optimized component sizes, tapered capillary tips, and adjustment of the capillary with respect to the liquid sheath tube during electrospray operation (active capillary positioning) to establish a stable electrospray quickly and reliably. The interface is especially effective at low flow rates, and CE/MS with a liquid sheath flow rate of 250 nL/min has been achieved. Active capillary positioning also allows on-line capillary isoelectric focusing mass spectrometry with in-probe focusing. In this application, the capillary is retreated into the liquid sheath tube, which becomes a microreservoir. After focusing, the capillary is returned to its proper position for electrospray, and focused zones are mobilized into the mass spectrometer for on-line detection. Both active capillary positioning and in-probe focusing readily lend themselves to automation.

Electrophoresis, Capillary↗

Capillary electrophoretic examination of underivatized oligosaccharide mixtures released from immunoglobulin G antibodies and CTLA4Ig fusion protein.

A procedure is presented for the separation of underivatized oligosaccharides by capillary electrophoresis (CE) with a phytic acid-borate buffer system. The presence of the phytic acid ion-pairing agent greatly increases resolution between oligosaccharides in the complex mixtures studied, which was demonstrated by the separation of oligosaccharides originating from various immunoglobulin G antibodies and CTLA4Ig, a biologic fusion protein. The conditions also resolve neutral oligosaccharides, usually a major CE limitation. High-performance anion-exchange chromatography with pulsed amperometric detection, a standard technique for oligosaccharide and sugar analysis, is used as a reference method to analyze some of the complex oligosaccharide mixtures.

Abatacept↗

Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions.

The read length for DNA sequencing using capillary electrophoresis and replaceable linear polyacrylamide (LPA) solutions has been extended to more than 1000 bases with a run time of 80 min. This result was successfully achieved through the combined use of cycle sequencing with dye-labeled primers, improved matrix and separation conditions, and enhanced base-calling software. The influences of LPA molecular weight and concentration on separation were investigated. Additionally, the separation buffer, column temperature, and electric field were adjusted to increase the number of resolvable DNA fragments per run while maintaining an enhanced separation speed. Using low concentrations [2% (w/v)] of high molecular weight LPA polymers (> 5.5 x 10(6) Da), elevated column temperature (50 degrees C) and moderately high field (150 V/cm), rapid sequencing analysis for more than 1000 bases on a model ssM13mp18 template was obtained with 96.8% accuracy.

Acrylic Resins↗

Examination of capillary zone electrophoresis, capillary isoelectric focusing and sodium dodecyl sulfate capillary electrophoresis for the analysis of recombinant tissue plasminogen activator.

The microscale techniques of CZE, cIEF and SDS capillary electrophoresis have been evaluated for the analysis of a complex glycoprotein, recombinant tissue plasminogen activator (rtPA). A series of omega-amino acid buffers (pH approximately 5) was found suitable for the CZE separation of rtPA on coated capillaries. rtPA could be resolved into a series of major and minor peaks in an epsilon-aminocaproic acid buffer containing 0.01% (v/v) Tween 80. For cIEF, a two step method with pressure mobilization was utilized. Using a commercial instrument, either a polymer solution with a 50 microns I.D. capillary or narrow bore capillaries without a polymer solution (25 microns I.D.) were employed. rtPA was resolved into at least eight species within a pI range of 6.4-9.2 using Ampholine 3.5-10. Migration time precision for the major peaks ranged from 0.2% for CZE to < or = 2-3% R.S.D. for cIEF. Total recovery of rtPA from the capillary was also demonstrated for both methods. Analysis of rtPA, rtPA Type I, rtPA Type II and the desialylated forms resulted in the expected elution profiles. Finally, the potential of SDS capillary electrophoresis using a coated capillary for an rtPA Type I/Type II purity assay was shown.

Acetates↗

DNA sequence analysis of Prinker-modified restriction fragments after collection from capillary electrophoresis with replaceable matrices.

This paper demonstrates the procedure of sequencing DNA restriction fragments isolated by a recently developed fraction collector after CE separation. In particular, using pBr 322 plasmid as a model system, a double digest was performed with Eco RI and Pst 1 restriction enzymes to produce two fragments of 749 base pairs (bp) and 3612 bp, both with cohesive ends. Prinkers, specific linkers complementary to the cohesive ends, were then ligated to both fragments (increasing the size by 59 bp each). These Prinker-modified fragments were separated by CE and collected. The success of the collection was demonstrated by reinjection of each isolated fraction with laser-induced fluorescence detection, using ethidium bromide as intercalater. The 808 bp isolated fragment was then polymerase chain reaction-amplified with appropriate primers for the Prinker ends, followed by cycle sequencing. Both strands of the fragment were run on an ABI 373, sequencing 427 bases and 450 bases, respectively, with a read accuracy of 99.3%. This approach with Prinker-modified restriction fragment and automated CE fraction collection can be used as a general procedure for sequencing unknown genomic DNA as well as mutated DNA mixtures.

Automation↗

Quantitative competitive polymerase chain reaction: analysis of amplified products of the HIV-1 gag gene by capillary electrophoresis with laser-induced fluorescence detection.

A quantitative competitive polymerase chain reaction (PCR) assay for the detection and quantification of HIV-1 has been developed using capillary electrophoresis. Separation of the PCR products is carried out in coated capillaries filled with replaceable linear polyacrylamide, and detection is performed using laser-induced fluorescence. The quantitative capabilities of this assay are described. We show results from analysis of a noninfectious plasmid encoding the HIV genome and integrated proviral DNA. Potential applications of this assay are discussed.

Cell Line↗