Root fracture during insertion of prefabricated posts related to root size.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to B L Musikant.
Explore the source record for details and available documents.
Thirty-one dentists were tested relative to the optimal and maximum amount of torque they could deliver to posts in teeth. The mean for the optimal amount of torque was 15.55 ounce-inches, and the mean for the maximum amount of torque was 35.29 ounce-inches. Female dentists showed a statistically significantly lower mean difference of 24.5 ounce-inches on the maximum torque test.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This study evaluated the apical leakage for three endodontic systems: (1) lateral condensation with Essential Dental System's epoxy adhesive: (2) Thermafil with Thermaseal adhesive; and (3) EZ-Fill Bi-directional spiral with EDS' epoxy adhesive. Five groups of 10 recently extracted single-rooted human teeth were used. Results showed that lateral condensation, and the EDS' EZ-Fill Bi-directional, and Thermafil techniques did not differ from each other, but differed from the no treatment group and the instrumented-unfilled group. In the current study, the EZ-Fill Bi-directional technique produced a tighter apical seal than either lateral condensation or Thermafil obturation techniques, but they all were not significantly different. EZ-Fill Bi-directional is a faster and more economical alternative to lateral condensation and Thermafil obturation.
A sequence of steps constituting an innovative way of cleansing, shaping and obturating a root canal system is described. The advantages of this sequence over other instrumentation and obturation techniques are discussed.
Retention was compared of an active post system (Flexi-Flange), a metal passive prefabicated post system (ParaPost), a passive prefabricated burnout post system (ExactaCast) with and without grooved dentin walls, and a zirconium oxide ceramic post design (Cerapost). The Flexi-Flange with Flexi-Flow Natural cement obtained the highest retentive value of 270.4 lb. The Cerapost cemented with Universal Cement had the lowest retention value of 23.4 lb. The ExactaCast with grooved dentin walls was significantly stronger than the ExactaCast without grooving, the ParaPost, and the Cerapost. The two ExactaCast groups and the ParaPost group had higher retention than the Cerapost group.
This study calculated the flexural strength for six reinforced restorative materials and demonstrated that flexural strength values can be determined simply by using physical parameters (diametral tensile strength and Young's modulus values) that are easily determined experimentally. A one-way ANOVA analysis demonstrated a statistically significant difference between the two reinforced glass ionomers and the four composite resin materials, with the composite resin being stronger than the glass ionomers.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The purpose of this study was to determine the fracture load for three different core materials supported by three different post systems. The study was divided into nine separate groups, and each group comprised 10 samples. Specimens were placed in a special jig on a 45-degree angle, and the fracture load values were obtained using a universal testing machine. A 3 x 3 factorial two-way analysis of variance (P < .0408) was used to test the effects of core material and post type on the fractural resistance. Fracture load values (as measured in pounds) were: Flexi-Post/Ti-Core, 204.9; Vlock/Ti-Core, 218.8; Parapost/Ti-Core, 164.8; Flexi-Post/Tytin, 156.0; Vlock/Tytin, 100.6; Parapost/Tytin, 134.6; Flexi-Post/Ketac-Silver, 69.4; Vlock/Ketac-Silver, 50.4; and Parapost/Ketac-Silver, 37.7. The titanium composite, Ti-Core, had the greatest fracture load values in all instances; the silver-filled glass-ionomer specimen, Ketac-Silver, had the least. The Flexi-Post and the microthread, Vlock, had the greatest fracture load values, and the Parapost had the least. Both the Flexi-Post and Vlock post have large bulky heads with many vertical and horizontal grooves, apparently facilitating the locking of the core material into the post.