PubMed Health⌕ Search

Biomedical subjects

B Lüderitz

Publications and source records attributed to B Lüderitz.

At least 55 records · Page 3Linked to original sources

[QT prolongation and torsade de pointes tachycardia during therapy with maprotiline. Differential diagnostic and therapeutic aspects].

HISTORY AND ADMISSION FINDINGS: A 69-year-old somnolent woman developed severe heart failure, aggravated by recurrent episodes of ventricular tachycardia. The patient showed central and peripheral edema. 24 hours earlier, she had suffered cerebral seizures that were successfully terminated by phenytoin. For 13 years, persistent atrial fibrillation had been frequency-controlled with antiarrhythmic drugs (verapamil and glycosides) and treated by oral anticoagulation. In addition, there had been long-term anti-depressant therapy with the tetracyclic agent maprotiline. INVESTIGATIONS: Torsade de pointes tachycardia was documented in the electrocardiograms. In addition, the QT interval was extensively prolonged (QTc = 0.70 sec). Neither electrolyte disturbances nor acute cardiac ischemia were seen. Echocardiography revealed a highly reduced ejection fraction of 25 % and a moderately dilated left ventricle. Angiography showed a collateralized occlusion of the right and plaques of the left coronary artery. TREATMENT AND COURSE: Repeated torsade de pointes tachycardia resulted in hemodynamic compromise and were terminated by defibrillations. After intravenous magnesium and xylocaine administration as well as with termination of maprotiline and antiarrhythmic co-medication, QT prolongation decreased. In addition, the recurrent torsade de pointes tachycardia stopped. Subsequently, however, there were several bradycardia episodes, QT duration remained long. Accordingly, a VVI pacemaker was implanted. Up to now, the patient is doing well. CONCLUSIONS: With antidepressant therapy, a risky constellation including comorbidity and interactions with potentially arrhythmogenic drugs may lead to QT prolongation. Medication that delays conduction or causes bradycardia may generally favour torsade de pointes tachycardia. In case of indispensable multi-drug therapy, regular clinical as well as electrocardiographic monitoring with special emphasis on QT interval is mandatory.

Aged↗

[A new dual-chamber defibrillation system: duration, frequency and circadian variation of recurrent supraventricular tachyarrhythmias].

BACKGROUND: The treatment of concomitant atrial tachyarrhythmias in patients with malignant ventricular tachyarrhythmias is a major challenge for new defibrillator devices. Atrial fibrillation is not only responsible for inappropriate ventricular therapies, but also reduced left ventricular performance, especially in patients with heart failure and severely depressed left ventricular function. Furthermore, it is a strong risk factor for the development of thromboembolism. NEW SYSTEM: A new dual-chamber implantable defibrillator is capable of tiered atrial therapies for both regular and irregular atrial tachyarrhythmias. In first investigations a high sensitivity and specificity could be shown as well as a promising therapy efficacy of atrial antitachycardia ramp and burst pacing for the treatment of atrial tachycardias. Atrial ramp pacing has shown to be successful for regular atrial tachyarrhythmias in up to 60 to 70% of all episodes. The results have supported a programming of a high first shock energy for treatment of atrial fibrillation. The incidence of atrial fibrillation in patients with a history of atrial fibrillation or without is much higher in the present investigated patient populations than expected. CONCLUSION: The more complicated and subtle new dual-chamber detection algorithm has proven to be safe and effective both for the detection of ventricular tachycardia but also in terms of an increase of specificity and a reduction of inappropriate ventricular therapies for atrial tachyarrhythmias.

Atrial Fibrillation↗

[Is brain blood supply affected by changes in cardiac volume? Measurements of brain blood supply in healthy subjects during volume overload and in patients with artificial pacemaker by changing the pacing rate].

A constant cerebral blood flow (CBF) in the presence of systemic blood pressure changes and cardiac output (CO) alterations during physiological conditions are postulated by the mechanism of cerebral autoregulation. The aim of the present study is the analysis of CBF in pacemaker (PM) patients with unspecific neurological symptoms. CBF was measured in 9 controls and 23 pacemaker patients with 133xenon, CO using Doppler echocardiography or impedance cardiography. Mean and individual CBF in controls remained unchanged when a CO increase of 28% induced by volume overload was observed. In PM patients a mean CO increase of 38% induced by an increase of basic pacing rate caused different effects of CBF. CBF increased or decreased by about 10% or remained constant. In summary, the data suggest an impairment of cerebrovascular function in those patients with concomittant CBF changes due to CO alterations (15/23 approximately equal to 65%). Thus, the analysis of brain perfusion in PM patients with unspecific neurological symptoms is possibly a new diagnostic feature in the future. It can be discussed whether or not indication and optimizing of pacemaker therapy has to be additionally analyzed by determination of endorgan perfusion.

Adult↗

Algorithms for better arrhythmia discrimination in implantable cardioverter defibrillators.

The discrimination of concomitant atrial tachyarrhythmias and sinus tachycardias in patients with malignant ventricular tachyarrhythmias is a major challenge for new defibrillator devices. Different algorithms have now been established to distinguish between atrial and ventricular tachyarrhythmias. Furthermore, new dual-chamber implantable defibrillators are capable of tiered atrial therapies for both regular and irregular atrial and ventricular tachyarrhythmias. The increasingly complex and subtle dual-chamber detection algorithms have proven to be safe and effective for the detection of ventricular tachycardia, and also in terms of an increase in specificity and a reduction in inappropriate ventricular therapies for supraventricular tachyarrhythmias. Stable electrode position, and a continuous and correct atrial signal quality, are prerequisites for atrial therapies and algorithms for arrhythmia discrimination.

Algorithms↗

Prevalence of left atrial chamber and appendage thrombi in patients with atrial flutter and its clinical significance.

OBJECTIVES: The study was done to assess the prevalence of left atrial (LA) chamber and appendage thrombi in patients with atrial flutter (AFl) scheduled for electrophysiologic study (EPS), to evaluate the prevalence of thromboembolic complications after transesophageal echocardiographic (TEE)-guided restoration of sinus rhythm and to evaluate clinical risk factors for a thrombogenic milieu. BACKGROUND: Recent studies showed controversial results on the prevalence of atrial thrombi and the risk of thromboembolism after restoring sinus rhythm in patients with AFl. METHODS: Between 1995 and 1999, patients with AFl who were scheduled for EPS were included in the study. After transesophageal assessment of the left atrial appendage and exclusion of thrombi, an effective anticoagulation was initiated and patients underwent EPS within 24 h. RESULTS: We performed 202 EPSs (radiofrequency catheter ablation, n = 122; overdrive stimulation, n = 64; electrical cardioversion, n = 16) in 139 consecutive patients with AFl. Fifteen patients with a thrombogenic milieu were identified. All of them had paroxysmal atrial fibrillation (AF). Transesophageal echocardiography revealed LA thrombi in two cases (1%). After EPS no thromboembolic complications were observed. Diabetes mellitus, arterial hypertension and a decreased left ventricular ejection fraction were found to be independent risk factors associated with a thrombogenic milieu. CONCLUSIONS: The findings of a low prevalence of LA appendage thrombi (1%) in patients with AFl and a close correlation between a history of previous embolism and paroxysmal AF support the current guidelines that patients with pure AFl do not require anticoagulation therapy, whereas patients with AFl and paroxysmal AF should receive anticoagulation therapy. In addition, the presence of clinical risk factors should alert the physician to an increased likelihood for a thrombogenic milieu.

Aged↗

Case report: regional cerebral hypoperfusion induced by ventricular tachycardia - short-term hippocampal hypoperfusion and its potential relationship to selective neuronal damage.

BACKGROUND: Focussing on regional cerebral hypoperfusion during hemodynamically stable, but borderline hypotensive, sustained ventricular tachycardia (VT) experimental studies show (1) a reduction of cerebral blood flow (CBF) during tachyarrhythmias in contrast to the concept of CBF autoregulation, (2) a mediation of hypoperfusion by neuronal and humoral mechanisms, and (3) an involvment of microcirculation due to an ischemic stress response of the cerebral tissue. The clinical relevance of these observations remains still unclear. CASE REPORTS: Two patients with coronary artery disease, left ventricular dysfunction and sustained monomorphic VT underwent electrophysiological study. VT was induced and the tracer (99m)Tc-HMPAO was injected after 3 minutes of ongoing VT. Regional CBF during this life threatening arrhythmia was determined with brain SPECT. A scanning protocol was performed after termination of VT. The measurements were repeated at baseline during normofrequent sinus rhythm (SR) one week later. CBF during SR was significantly reduced in the temporal lobe in comparison to the conditions during stable VT, particularly in the left hippocampus. CONCLUSION: The reduction of hippocampal CBF due to cerebrovascular vasoconstriction and neuronal reflex mechanism previously observed in experiments during stable, sustained VT can be confirmed in a clinical scenario by high resolution (99m)Tc-HMPAO brain SPECT. This supports the hypothesis that repetitive stable VT can play a role in the pathophysiology of cerebrovascular insufficiency. Further clinical studies are needed to analyze the impact of tachyarrhythmias on cognitive and mnemic function.

Aged↗

Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 Tesla?

The safety and feasibility of magnetic resonance imaging (MRI) in patients with cardiac pacemakers is an issue of gaining significance. The effect of MRI on patients' pacemaker systems has only been analyzed retrospectively in some case reports. Therefore, this study prospectively investigated if MRI causes irreversible changes in patients' pacemaker systems. The effect of MRI at 0.5 Tesla on sensing and stimulation thresholds, lead impedance and battery voltage, current, and impedance was estimated during 34 MRI examinations in 32 patients with implanted pacemakers. After measurements at baseline and with documentation of intrinsic rhythm and modification of the pacing mode, patients underwent MRI. The rest of the function time of the pacemaker was calculated. Measurements were again performed after 99.5 +/- 29.6 minutes (mean +/- SD), immediately after MRI examination, and 3 months later. Lead impedance and sensing and stimulation thresholds did not change after MRI. Battery voltage decreased immediately after MRI and recovered 3 months later. Battery current and impedance tended to increase. The calculated rest of function time did not change immediately after MRI. MRI affected neither pacemaker programmed data, nor the ability to interrogate, program, or use telemetry. Surprisingly, in the gantry of the scanner, temporary deactivation of the reed switch occurred in 12 of 32 patients when positioned in the center of the magnetic field. Missing activation of the reed switch through the static magnetic field at 0.5 Tesla is not unusual. MRI at 0.5 Tesla does not cause irreversible changes in patients' pacemaker systems.

Contraindications↗

Blood flow assessment by ultrasound-induced destruction of echocontrast agents using harmonic power Doppler imaging: which parameters determine contrast replenishment curves?

OBJECTIVE: To evaluate the feasibility of flow determinations by contrast replenishment using harmonic power Doppler imaging (H-PDI). BACKGROUND: The application of indicator dilution principles on contrast echocardiography is limited by numerous methodical problems. Recently, a new method was introduced that relies on ultrasound-mediated microbubble destruction and evaluation of the contrast replenishment. METHODS: Definity, a perfluorocarbon-derived contrast agent under development, was continuously infused into a steady flow phantom and H-PDI registrations were performed within a silicone tube (d = 8 mm). Replenishment interval between destruction and imaging frame was varied from 0.04-2 seconds. Nonlinear curve fitting was performed using an exponential mathematical model. RESULTS: Strong linear correlation between contrast dose and maximum signal intensity as well as between flow and the slope variable beta of the replenishment curve was found for all settings (r > 0.96). Maximum signal intensity and contrast replenishment rate were found to be a function of emission power and were significantly influenced by depth and focus position. CONCLUSION: The feasibility of flow assessment using replenishment curves obtained by H-PDI was demonstrated. However, in experimental conditions, flow analysis was severely influenced by ultrasound system settings and imaging conditions such as emission power, sound field geometry, and investigation depth. For a clinical use of this promising approach, algorithms that take specific system settings and imaging conditions into account have to be found. Imaging modalities that enable a most homogeneous scan field are best suited for the assessment of contrast replenishment.

Contrast Media↗

Surgical management of complications caused by transcatheter ASD closure.

BACKGROUND: Transcatheter occlusion of uncomplicated atrial septum defects (ASD) is recognized as an effective and minimally invasive method. Sometimes, serious early and late complications require surgical intervention. We therefore investigated reasons and outcomes of the secondary surgical approach. METHODS: 5 patients (aged 5-73 yrs) were admitted to our institution for device explantation and surgical ASD closure. ASDOS devices (A devices) had to be explanted in 4 patients and a SIDERIS "buttoned" occluder (S device) had to be explanted in 1 patient. The period from transcatheter implantation to surgical explantation ranged from 1 hour to 3 years. RESULTS: 3 patients (60 %) had to be operated in an emergency setting. In our youngest patient (5 yrs), the A device separated and embolized into the aorta and pulmonary artery. A pregnant women who needed emergent cesarean section developed hemopericard and tamponade due to atrial perforation by a fractured leg of an A device. In another A device, a suspect endocarditis caused membrane perforation. Malpositioning of an S device was the reason for operation. All patients recovered well without neurological symptoms. CONCLUSIONS: Transcatheter closure of uncomplicated ASD is a feasible alternative but surgical stand-by is essential. Nevertheless more complicated ASD should be operated, especially since the cosmetically satisfactory techniques of minimal invasive heart surgery are available.

Adult↗