Radiobiological effectiveness (RBE) of megavoltage X-ray and electron beams in radiotherapy.

Recent experiments indicate that significant differences exist in the microdosimetric properties (i.e., lineal energy distributions) of megavoltage X-ray and electron beams used in radiation therapy. In particular, dose averaged values of lineal energy for 18 MeV electrons are 10-30% lower than for 10 MeV bremsstrahlung X rays, which in turn are 30-60% lower than for 250 kVp X rays. Differences of this magnitude may manifest themselves in observable radiobiological effectiveness (RBE) differences between these radiations. Cell survival data have been obtained for line DLD-1 human tumor cells on all three of the above radiation sources. Results clearly demonstrate an RBE difference between orthovoltage and megavoltage radiation (P = 0.001). A small difference is also measured in RBE between megavoltage photons and megavoltage electrons, but the difference is not statistically significant (P = 0.25). All biological, dosimetric, and microdosimetric data were obtained under nearly identical geometric conditions. These data raise interesting questions vis à vis the applicability of microdosimetric theories in the interpretation of biological effects.

Cell Line↗

A quantitative assessment of portal film contrast as a function of beam energy.

Portal film contrast on a specially designed test phantom has been studied as a function of photon beam energy and object-to-film distance. The results provide important insights into the physical processes responsible for image contrast. In particular, theoretical calculations of Compton scatter reactions in the phantom can be used to predict visual film contrast. Good agreement between theory and experiment can be achieved by evaluating the double differential Compton cross sections [d sigma (E,theta)/dE d theta] in the test object without resorting to variable parameters or artificial normalization. These calculations demonstrate the importance of low-energy photons, object-to-film distance, and object size on portal film contrast.

Biophysical Phenomena↗

Quantitative evaluation of a portal film contrast enhancement technique.

A study was conducted to evaluate the subjective improvement in portal film image quality resulting from the contact copy contrast enhancement technique which was introduced six years ago. Five observers were asked to identify and orient polyvinyl chloride cylinder images on both original and contrast-enhanced portal films taken with a 10-MeV linear accelerator. Fixed reviewing periods (T) were alloted of 20, 40, and 60 s as well as unlimited viewing time in order to increase the clinical relevance of this comparison. A scoring system and a probability representation were used to compare the original and enhanced films as a function of T. The results show a substantial increase in object detectability for the enhanced films at the short viewing times (T = 20, 40, and 60 s). For longer times (T greater than or equal to 80 s) the object detectability for enhanced and original films is not statistically different.

Humans↗