PubMed Health⌕ Search

Biomedical subjects

B M Hoover

Publications and source records attributed to B M Hoover.

5 recordsLinked to original sources

Rapid word-learning in normal-hearing and hearing-impaired children: effects of age, receptive vocabulary, and high-frequency amplification.

OBJECTIVE: This study examined rapid word-learning in 5- to 14-year-old children with normal and impaired hearing. The effects of age and receptive vocabulary were examined as well as those of high-frequency amplification. Novel words were low-pass filtered at 4 kHz (typical of current amplification devices) and at 9 kHz. It was hypothesized that (1) the children with normal hearing would learn more words than the children with hearing loss, (2) word-learning would increase with age and receptive vocabulary for both groups, and (3) both groups would benefit from a broader frequency bandwidth. DESIGN: Sixty children with normal hearing and 37 children with moderate sensorineural hearing losses participated in this study. Each child viewed a 4-minute animated slideshow containing 8 nonsense words created using the 24 English consonant phonemes (3 consonants per word). Each word was repeated 3 times. Half of the 8 words were low-pass filtered at 4 kHz and half were filtered at 9 kHz. After viewing the story twice, each child was asked to identify the words from among pictures in the slide show. Before testing, a measure of current receptive vocabulary was obtained using the Peabody Picture Vocabulary Test (PPVT-III). RESULTS: The PPVT-III scores of the hearing-impaired children were consistently poorer than those of the normal-hearing children across the age range tested. A similar pattern of results was observed for word-learning in that the performance of the hearing-impaired children was significantly poorer than that of the normal-hearing children. Further analysis of the PPVT and word-learning scores suggested that although word-learning was reduced in the hearing-impaired children, their performance was consistent with their receptive vocabularies. Additionally, no correlation was found between overall performance and the age of identification, age of amplification, or years of amplification in the children with hearing loss. Results also revealed a small increase in performance for both groups in the extended bandwidth condition but the difference was not significant at the traditional p = 0.05 level. CONCLUSIONS: The ability to learn words rapidly appears to be poorer in children with hearing loss over a wide range of ages. These results coincide with the consistently poorer receptive vocabularies for these children. Neither the word-learning or receptive-vocabulary measures were related to the amplification histories of these children. Finally, providing an extended high-frequency bandwidth did not significantly improve rapid word-learning for either group with these stimuli.

Adolescent↗

Effect of stimulus bandwidth on the perception of /s/ in normal- and hearing-impaired children and adults.

Recent studies with adults have suggested that amplification at 4 kHz and above fails to improve speech recognition and may even degrade performance when high-frequency thresholds exceed 50-60 dB HL. This study examined the extent to which high frequencies can provide useful information for fricative perception for normal-hearing and hearing-impaired children and adults. Eighty subjects (20 per group) participated. Nonsense syllables containing the phonemes /s/, /f/, and /O/, produced by a male, female, and child talker, were low-pass filtered at 2, 3, 4, 5, 6, and 9 kHz. Frequency shaping was provided for the hearing-impaired subjects only. Results revealed significant differences in recognition between the four groups of subjects. Specifically, both groups of children performed more poorly than their adult counterparts at similar bandwidths. Likewise, both hearing-impaired groups performed more poorly than their normal-hearing counterparts. In addition, significant talker effects for /s/ were observed. For the male talker, optimum performance was reached at a bandwidth of approximately 4-5 kHz, whereas optimum performance for the female and child talkers did not occur until a bandwidth of 9 kHz.

Adult↗

The relation between stimulus context, speech audibility, and perception for normal-hearing and hearing-impaired children.

In this study, the influence of stimulus context and audibility on sentence recognition was assessed in 60 normal-hearing children, 23 hearing-impaired children, and 20 normal-hearing adults. Performance-intensity (PI) functions were obtained for 60 semantically correct and 60 semantically anomalous sentences. For each participant, an audibility index (AI) was calculated at each presentation level, and a logistic function was fitted to rau-transformed percent-correct values to estimate the SPL and AI required to achieve 70% performance. For both types of sentences, there was a systematic age-related shift in the PI functions, suggesting that young children require a higher AI to achieve performance equivalent to that of adults. Improvement in performance with the addition of semantic context was statistically significant only for the normal-hearing 5-year-olds and adults. Data from the hearing-impaired children showed age-related trends that were similar to those of the normal-hearing children, with the majority of individual data falling within the 5th and 95th percentile of normal. The implications of these findings in terms of hearing-aid fitting strategies for young children are discussed.

Acoustic Stimulation↗

Effect of earmold fit on predicted real ear SPL using a real ear to coupler difference procedure.

OBJECTIVES: The goal of Experiment I was to quantify the SPL entering the ear canal via a secondary pathway created by a vent in the earmold and/or a slit leak around the earmold. The goal of Experiment II was to determine the validity of a real ear to coupler difference (RECD) procedure under conditions that are likely to produce errors (e.g., when hearing aid gain in the low frequencies is minimal and large negative RECD values occur as a result of venting or a loosely fitting earmold). DESIGN: In Experiment I, the SPL entering the ear via the secondary pathway was measured in 61 hearing-impaired children and 13 normal-hearing adults. In Experiment II, traditional probe microphone measures of real ear SPL were compared to the SPL predicted using the RECD procedure in five normal-hearing adults with loosely fitting earmolds. RESULTS: Results of Experiment I indicated that sound entered the ear canal unattenuated at 250 and 500 Hz, regardless of earmold fit, vent size, or subject age. In Experiment II, the largest differences between traditional probe microphone measures of SPL and predicted measures were noted when hearing aid gain was 0 dB and large negative RECD values were present. When hearing aid gain was minimal and the RECD was in the -10 to -22 dB range, predicted values underestimated the real ear SPL by an average of 14 dB. CONCLUSIONS: Although the results of this study apply only to a limited range of conditions found in clinical practice, in those cases, the errors may influence clinical decisions about the type of hearing aid fitted and the amount of gain provided. Potential solutions to this problem are discussed.

Adult↗

Recognition performance for four combinations of FM system and hearing aid microphone signals in adverse listening conditions.

OBJECTIVE: Children with moderate to severe hearing loss routinely use personal frequency modulated (FM) systems in the classroom to improve the signal to noise ratio of teacher-directed speech with notable success. Attention is now being given to the ability of these children to hear other students via the hearing aid (HA) microphone while using an FM system. As a result, a variety of FM system and HA microphone combinations have been recommended for classroom use. To date, there are no studies regarding the efficacy of these FM/HA combinations. The purpose of this study was to evaluate recognition performance using four FM/HA combinations and to characterize that performance for stimuli received primarily through FM system and HA microphone transmission. DESIGN: Recognition performance for FM system and HA microphone signals was evaluated for two symmetrical and two asymmetrical FM/HA combinations using two commercially available FM systems (one conventional and one FM-precedence circuit). Eleven children (ages 9 to 12) with moderate to severe sensorineural hearing loss and eight children (ages 10 to 11) with normal hearing served as subjects. The two symmetrical FM/HA combinations included: 1) binaural FM system and HA microphone input using the conventional FM system, and 2) binaural FM and HA input using the FM-precedence circuit. The conventional FM system was used for the two asymmetrical combinations and included: 1) binaural FM input and monaural HA input, and 2) FM input to one ear and HA input to the other. Stimuli were 33 consonants presented in the form of nonsense syllables. The stimuli were presented through three loudspeakers representing a teacher and two fellow students in a classroom environment. Speech shaped noise was presented through two additional loudspeakers. RESULTS: In general, no statistically significant differences in recognition performance were found between any of the FM/HA combinations. Mean recognition scores for HA microphone transmission (55%) were significantly poorer than those for FM system transmission (75%). As expected, initial consonants were more easily recognized than final consonants via FM system and HA microphone transmission. However, voiceless consonants were more easily recognized than voiced consonants via HA microphone transmission, which was not predicted on the basis of previous research. CONCLUSIONS: These results suggest that a certain amount of flexibility is present when choosing an FM/HA combination. However, recognition performance via the HA microphones was consistently poorer than performance via FM transmission. Because relevant material also originates from fellow students (e.g., answering teacher-directed questions), input via the HAs is often as important as information originating from the teacher. The results suggest that attempts to improve performance for signals transmitted through the HA microphones in a classroom setting would benefit children with hearing loss.