The video dilution technique for measuring blood flow consists of electronically and mathematically processing video-taped selective arteriograms to measure the flow in selectively catheterized arteries and to express this flow as a fraction of the flow in any reference artery. Flows were measured by video dilution and an electromagnetic flowmeter in ten dogs; the correlations were excellent. Video dilution flows were also measured in 105 patients. The technique is accurate, simple, and adds no risk to routine selective arteriography.
A new videodensitometric method of measuring blood flow in the splanchnic arteries as a fraction of the cardiac output was compared to electromagnetic flow readings in dogs. A previous investigation regarding the accuracy of the method in vitro was extended to prove that the videodensitometric technique was highly accurate also in vivo. The simplicity of the technique suggests that the videodensitometric method could be used to estimate blood flow in splanchnic arteries during routine angiography.
Cerebral angiography performed on a patient with a preliminary diagnosis of jugular foramen syndrome revealed a highly vascular malignant chemodectoma supplied mainly by the left ascending pharyngeal artery. Blood flow was determined during angiography in the extracranial branches of the carotid arteries by video dilution technique. The decrease of blood flow after partial embolization of the left ascending pharyngeal artery was also quantified. The application and value of video dilution technique in blood flow determination, together with the angiographic findings are discussed.
Determination of blood flow in the cerebral arteries as a fraction of the cardiac output was performed by the videodensitometric method and compared to electromagnetic flow readings in dogs. The method proved to be highly accurate in vivo confirming previous experiments in vitro. It is simple to perform during routine cerebral angiography and may produce significant physiologic data not readily available by other means.
A newly developed doppler ultrasound flow measuring instrument was applied to determination of aortic arch blood flow in 6 near-term fetuses and 2 neonates and to umbilical cord flow in 2 fetuses. The method and results are presented and indicate good agreement between this noninvasive technique and expected values for aortic arch flow in human fetuses and neonates.
A new concept for determining relative blood flow in single arteries using videodensitometry to obtain contrast dilution curves has been experimentally evaluated. Flow as a fraction of cardiac output in the cerebral, renal, splanchnic, and iliac arteries was determined in 110 measurements in 11 dogs. The mean difference between measurements by electromagnetic flow probe and videodensitometric values was less than 2%, and the correlation coefficient was r = 0.96 for all data. The method is simple compared to previous videodensitometric techniques, because the dimensions of the vessel and the mean transit time of the contrast bolus can be neglected. The necessary equipment includes a stable image intensifier-television chain, a videotape recorder, a videodensitometer, and a graphic recorder. The method is now used to measure blood flow in cerebral, coronary, splanchnic, renal, and ileofemoral arteries during routine clinical angiography.
A videodensitometric method for estimating relative flow was employed in a patient with a bovine arteriovenous fistula. Analogous arteriovenous communications of different sizes were created in two dogs for comparison. Local and general hemodynamic parameters were measured. The videodensitometric method proved to be highly accurate compared to electromagnetic flow readings and is the method of choice in estimating shunt flow in connection with routine angiography.
Twenty patients with a mean age of 79 years were followed over a period of 6 months after intra-arterial insufflation of CO2 in the lower extremity. All patients had severe peripheral occlusive arterial disease caused by atherosclerosis and were scheduled for amputation. A significant increase of the distal perfusion pressure was obtained in the majority of the cases resulting in pain relief and healing of ulcers and gangrenes.
Based on 39 cineangiographies in 23 patients performed during respiration with tracing of the cardiac chambers and the diaphragm, it has been found that the heart moves significantly with respiration, approximately half as much as the diaphragm during shallow or normal respiration. The cardiac respiratory motion indicates that gating of the respiratory cycle as well as the cardiac cycle is necessary in three-dimensional reconstruction of the heart using a large number of heart beats for recording.
A modified orthogonal tangent correction algorithm is presented for computerized tomography. The algorithm uses four X-rays scans spaced 45 degrees apart, to reconstruct a transverse axial image. The reconstruction procedure is interative in which image matrix elements are corrected by alternately matching the two sets of orthogonal scan data. The algorithm has been applied to phantom data as well as to video recorded fluoroscopic data.
A contrast medium was injected in the aortic arch and selectively in a renal artery to estimate the renal blood flow as a percentage of the cardiac output by the videodensitometric (VD) method. Twenty-six paired VD measurements in four mongrel dogs were obtained and the results compared to electromagnetic (EM) flow readings from the aortic arch and a renal artery. The relative renal blood flow estimated by the VD method averaged 9.1% and correlated with the EM flow average of 9.6% with r = 0.96. Previous in vitro investigations of relative flow in a model have now been validated in vivo. These results suggest that videodensitometry could be a clinical tool for measuring renal blood flow in conjunction with routine arteriography.
A description of a new Doppler ultrasound flow measuring instrument is given along with representative measurements of blood flow in the canine renal artery and the human aortic arch, renal artery, and transplanted kidney renal artery. The instrument is briefly described, and a discussion of the limitations of the technique is presented.
Video dilution technique (VDT) is currently performed in conjunction with routine cerebral angiography to determine carotid blood flow in humans. Preliminary results indicate that the blood flows (as a percentage of cardial output) of the common, internal, and external carotid arteries are 8.5%, 5.5%, and 3.0%, respectively (SD less than 1%). In contradistinction to previous techniques, VDT provides a safe and highly accurate method of determining carotid blood flow in human subjects. The usefulness of this technique in normal and pathologic states is discussed.
Video dilution technique is now available for clinical use in evaluating patients with peripheral vascular disease. The measurements can easily be performed in any modern angiographic suite. The only additional equipment required is a videodensitometer, video tape recorder, and a strip chart recorded. The new technique has been developed and tested in a hydrodynamic model and compared to volumetric flows. Further, the video dilution technique has been compared to electromagnetic flow readings using a canine model to measure the cerebral, renal, splanchnic, and extremity circulation and has proven to be extremely accurate (n = 389; r = 0.99). By applying the technique to patients with peripheral vascular disease, it is possible to evaluate the hemodynamic significance of stenotic lesions and arteriovenous shunts. Other uses of video dilution technique include evaluating the effects of vasoactive drugs and the adequacy of transluminal angioplasty.
Experimental embolization of the renal artery with cross-linked dextran (CLD) microspheres was performed in 6 dogs. The blood flow was monitored by electromagnetic flow meter (EM) in 3 dogs and by video dilution technique (VDT), adapted to an angiographic digital subtraction system, in a second group of 3 dogs. Retrograde flow in the embolized renal artery was detected by 99Tcm microspheres. Sequential emboli produce a predictable and equal flow response with both measuring techniques. Thus, the less invasive VDT can be used in the clinical setting to optimize and control embolization procedures. This type of flow monitoring has great potential in alerting the angiographer when approaching the risk level for retrograde flow.
Partial embolization of the spleen has been well established for the treatment of hypersplenism. A weakness of the technique is the lack of an objective method to quantitate the flow reduction during the procedure. The video dilution technique (VDT) has earlier been used to measure blood flow in regional arteries using video cassette replay. By adapting the VDT concept of relative flow to digital subtraction angiography, it is possible to calculate the flow reduction instantly following each injection of embolic material. We present a case of partial splenic embolization where the flow in the splenic artery was reduced to a predetermined level of 50 per cent of baseline flow. The clinical results were excellent. By observing the clinical results of partial embolization, terminated at different levels of flow reduction, it will be possible to optimize the results and prevent overembolization.
Since enhanced sensitivity to verapamil in essential hypertension has been noted, a relationship between verapamil and the sympathetic nervous system has been suggested. It has also been noted that both verapamil and lumbar sympathectomy appear to decrease the vasospasm seen in Raynaud's phenomenon. To further investigate the possible interrelationship between verapamil and the sympathetic nervous system, a unilateral lumbar sympathectomy was performed on eight dogs. Two weeks later the femoral artery blood flow response to intra-arterial verapamil was compared on the sympathectomy limb side and the non-sympathectomy limb side. Blood flow measurements were done without surgical trauma by video dilution technique. Although baseline femoral artery blood flow was unchanged and equal on both sides following sympathectomy (4.6% of cardiac output), there was a significant rise, p less than 0.05, in the blood flow response to verapamil on the side of sympathectomy. Therefore, sympathectomy appears to enhance the calcium channel blocking properties of verapamil.