Clinical significance of a new P wave lead vector for pacemaker follow-up of atrial functions.

Patient welfare requires routine follow-up procedures of implantable pacemakers. However, the assessment of atrial sensing and pacing functions in implantable pacemakers is often a challenge due to difficult identification of low amplitude P waves on surface electrocardiograms (ECGs). A previous body surface mapping study suggested that a novel P wave lead vector (P lead) had larger root mean square values than other standard leads. However, for pacemaker follow-up procedures, peak-to-peak amplitudes are more relevant than root mean square values. In this study, the peak-to-peak amplitudes of intrinsic and paced P waves recorded from surface ECG standard lead II and the P lead were compared. In addition, intrinsic and paced R waves were also compared. Data recorded from 15 patients undergoing electrophysiological studies indicated that peak-to-peak amplitudes of the P lead were significantly larger than standard lead II: 24% for intrinsic P waves, 30% for paced P waves, and 72% for intrinsic R waves. In addition, the P lead amplitude of paced R waves showed a nonsignificant increase of 24% compared with standard lead II. Therefore, the use of this new lead vector may improve the clinical ease-of-use and reduce the time required for follow-up procedures of implantable pacemakers for atrial sensing and pacing assessments.

Atrial Function↗

Separation of ventricular tachycardia from sinus rhythm using a practical, real-time template matching computer system.

Template matching morphology analysis of the intraventricular electrogram (IVEG) has been proposed for inclusion in implantable cardioverter defibrillators (ICDs) to reduce the number of false ventricular tachyarrhythmia detections caused by rate overlap between ventricular tachycardia (VT) and sinus tachycardia and/or supraventricular tachycardia. Template matching techniques have been developed that reduce the computational complexity while preserving the perceived important aspects of electrogram amplitude and baseline independence found in such computationally unsolved methods as correlation waveform analysis (CWA). These methods have been shown to work as well as CWA for separation of VT, however, they have not been proven in real-time on a system that incorporates many of the constraints of present day ICDs. The present study was undertaken with two purposes: (1) to determine if real-time IVEG template matching analysis on an ICD sensing emulator was accurate in separating VT from sinus rhythm (SR) electrograms; and (2) to compare amplitude normalized area of difference (NAD) with signature analysis (SIG), a new, computationally less expensive technique that normalizes for amplitude variation within the expected physiological level of variability. In this study, IVEGs, obtained from 16 patients who underwent electrophysiological study (EPS) for evaluation of sustained ventricular arrhythmia, were digitized to 250 Hz with 6-bit quantization after filtering (16-44 Hz) and differentiation. After an SR template was selected and periodically updated, it was compared to subsequent IVEGs using NAD and SIG. In general, SIG calculates the fraction of samples occurring outside template window boundaries. Eleven-beat running medians from beat-by-beat NAD and SIG results were determined.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Template matching techniques for electrophysiologic signals: a practical, real-time system for detection of ventricular tachycardia.

Time domain template matching morphology techniques have been proposed for inclusion in implantable cardioverter defibrillators (ICDs) for the detection of ventricular arrhythmias from intraventricular electrograms (IVEGs). However, ICDs have limited battery capacity which necessitate the use of low current drain algorithms. Although more computationally efficient template matching algorithms have been developed, none have incorporated the limitations inherent in current ICDs. An external ICD sensing prototype system was developed which filters, digitizes, and analyzes IVEGs during electrophysiology studies. Two template matching IVEG metrics, amplitude normalized area of difference and signature analysis, are calculated. These metrics are being tested clinically for their accuracy in differentiating ventricular tachycardia and sinus rhythm IVEGs.

Algorithms↗

Modulation of collision-induced changes in canine heart repolarization by cycle length.

The possibility that cycle length modulates the electronic effect of activation sequence on repolarization was investigated in experiments using isolated canine cardiac Purkinje strands, in situ canine ventricular myocardium, and computer simulations. Action potential durations and refractory periods during one-way propagation were compared to those obtained during action potential collision. In both the computer simulations and the Purkinje strand experiments, collision decreased action potential duration more at long cycle lengths than at short cycle lengths. Comparably, collision of activation fronts in ventricular myocardium was associated with greater reductions in refractory period during pacing at long cycle lengths than at short cycle lengths. Theoretic considerations indicate that the magnitude of electrotonic effects of activation sequence on repolarization are directly related to action potential height and the square root of membrane resistance during repolarization and are inversely related to conduction velocity. In computer simulations and Purkinje strand experiments, changes in conduction velocity and action potential height elicited by decreasing cycle length could not fully account for the cycle length dependence of collision-induced changes in repolarization. Time-varying membrane resistance of a single cell was calculated in the simulations by briefly hyperpolarizing the membrane and determining the change in total ionic current. Membrane resistance during repolarization was less at short cycle lengths than at long cycle lengths. The results suggest the cycle length dependence of collision-induced changes in repolarization results largely from the effect of cycle length on membrane resistance during action potential repolarization, with changes in action potential height and conduction velocity playing a lesser role.

Action Potentials↗

Detection of ventricular tachycardia using scanning correlation analysis.

Cross correlation is an accurate method for distinguishing normal sinus rhythm (NSR) from ventricular arrhythmias. The computational demands of the method, however, have prohibited development of an implantable device using correlation. In this study, temporal data compression prior to correlation analysis was used to reduce the total number of computations. Unipolar and bipolar intracardiac electrograms of NSR and 23 episodes of ventricular tachycardia (VT) from 23 patients were obtained from a right ventricular apex electrode catheter during routine electrophysiology studies. The data were filtered (1-11 Hz), digitized (250 samples/sec) and temporally compressed to 50 samples/sec. Data compression removed four out of every five samples by only saving the sample with the maximum excursion from the last saved sample. The average squared correlation coefficient (r2) was computed for the NSR and VT episodes using each patient's NSR waveform as a template. In all 23 patients, the r2 values showed large separation between NSR versus VT in both unipolar (0.93 +/- 0.05 vs 0.20 +/- 0.16, P less than 0.005) and bipolar (0.91 +/- 0.07 vs 0.17 +/- 0.11, P less than 0.005) electrode configurations using template lengths of 80% the intrinsic interval (avg +/- SD). Narrow templates (40% intrinsic interval or less) often resulted in multiple r2 peaks during each heart cycle and degraded the r2 separation (n = 10, P less than 0.005). High pass filtering at 3 Hz also degraded the r2 separation (n = 10, P less than 0.05). Standard noncompressed correlations indicated that data compression had negligible effects on the results. Thus, a computationally efficient cross correlation method was found to be a reliable detector of VT.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Estimating cardiac transmembrane activation and recovery times from unipolar and bipolar extracellular electrograms: a simulation study.

A model of one-dimensional action potential propagation was used to compare activation times and recovery times measured from simulated unipolar and bipolar electrograms with the activation and recovery times measured from simulated transmembrane action potentials. Theory predicts that the intrinsic deflection--the time of the maximum negative slope of the unipolar electrogram QRS complex--corresponds to the time of maximum positive slope of action potential depolarization. Similarly, the time of the maximum positive slope of the unipolar electrogram T wave corresponds to the time of maximum negative slope of action potential repolarization. This study showed that the difference between the unipolar electrogram activation time and the action potential activation time and the difference between the unipolar electrogram recovery time and the action potential recovery time were small during ideal conditions of uniform propagation in a long cable. Nonideal conditions, however, were associated with activation time differences in excess of 1.8 msec and recovery time differences in excess of 30 msec (243 msec in certain conditions). Nonideal conditions that had a major influence were changes in activation sequence, propagation in a short cable, and propagation through regions of nonuniform coupling resistance and/or nonuniform membrane properties. Nonideal conditions that had a smaller influence were variations in distance from the measurement site to the simulated tissue surface, nonzero reference potentials, and the addition of distant events. Recovery time differences were more sensitive to the nonideal conditions than were activation time differences, and both depended on the action potential shape. When distant events significantly contributed to the unipolar electrogram waveform, the time differences when bipolar electrograms were used were less than those when unipolar electrograms were used; however, under other conditions, the time differences were comparable. Results showed that activation times and especially recovery times measured from electrograms can be greatly affected by conditions independent of changes in the underlying action potential waveforms.

Action Potentials↗

Nonuniform epicardial activation and repolarization properties of in vivo canine pulmonary conus.

The relation between nonuniform epicardial activation and ventricular repolarization properties was studied in 14 pentobarbital anesthetized dogs and with a computer model. In 11 dogs, isochrone maps of epicardial activation sequence were constructed from electrograms recorded from the pulmonary conus with 64 electrodes on an 8 X 8 grid with 2-mm electrode separation. The heart was paced from multiple sites on the periphery of the array. Uniformity of epicardial activation was estimated from activation times at test sites and their eight neighboring sites. Acceleration shortened and deceleration prolonged refractory periods. The locations of acceleration and deceleration sites of activation differed during drives from various sites, and differences in uniformity of activation during pairs of drives were correlated to differences in refractory periods (r = 0.76, range 0.59-0.93). In three additional experiments, transmural activation sequence maps were constructed from electrograms recorded from needle-mounted electrodes placed upstream and downstream to epicardial activation delays. Activation proceeded from epicardium to endocardium upstream to the delays and from endocardium to epicardium downstream to the delays. A computer simulation of two-dimensional action potential propagation based on the Beeler-Reuter myocardial membrane model provided insights to the mechanism for the results of the animal experiments. The two-dimensional sheet modeled the transmural anisotropic histology of the canine pulmonary conus and corresponded to previous reports and histology of specimens from five experiments. Simulated activation patterns were similar to those found in the experimental animals. In addition, action potentials were electronically prolonged at sites of deceleration and shortened at sites of acceleration, results comparable to the animal experiments. Our findings demonstrate that the location of areas of nonuniform epicardial activation is dependent on drive site and that nonuniform activation electronically modulates repolarization properties. Therefore it seems likely that the site of origin of ectopic ventricular complexes, especially in ischemic myocardium where activation is nonuniform, could be an important determinant of whether ectopic activity initiates sustained tachyarrhythmias.

Action Potentials↗

Effects of activation sequence on ventricular refractory periods of ischemic canine myocardium.

Refractory periods were measured in pentobarbital-anesthetized dogs during control periods and one to one and a half hours after distal left anterior descending coronary artery occlusion. The refractory period test site was on the anterior surface of the left ventricle in the distribution of the artery to be occluded. Measurements were made during drive of the refractory period test site, drive of a distant site on the pulmonary conus and during fusion drive in which drive of the test site was delayed with respect to drive of the pulmonary conus. Refractory periods were longer during test site drive than during pulmonary conus or fusion drives in both the control periods and following coronary occlusion. However, the effects of driving mode on refractory periods were greater following coronary occlusion than in the control periods. The findings are likely secondary to different magnitudes of change in electrotonic interactions associated with changes in activation sequence in ischemic and nonischemic myocardium. The greater dependence of repolarization properties in ischemic than nonischemic tissue suggests that inhomogeneity of these properties could be modified considerably by the site of origin of ectopic ventricular complexes.

Action Potentials↗

A simple digital filter to remove line-frequency noise in implantable pulse generators.

This study investigated computer simulations and animal studies of a simple digital notch filter to remove 50-and 60-Hz line-frequency-noise interference. The digital notch filter was achieved by computing running subtraction of the intracardiac electrogram and the electrogram recorded one notch-sample period previously. Simultaneous rejection of the two worldwide line frequencies was obtained by computation of the minimum of two separate notch-filter outputs. Power consumption of this numerical algorithm was reduced for applications in implantable devices by operating the notch filters only from 20 msec to 50 msec after a sense event. A sense event was classified as a noise sense if the sum of notch-filter output during this window was less than a preset threshold of the sum of the raw data during the same time window. Otherwise, the sense event was classified as a true sense. The computer simulations determined an optimum threshold value of 33%. The filter was tested in five animal studies using a signal generator to inject additive noise interference. The results indicated that this simple filter could be implemented in an implantable pulse generator and could effectively exclude incorrect line-frequency-noise senses at the notched frequencies.

Algorithms↗