Charnley low-friction arthroplasty of the hip. Long-term results.

Charnley low-friction arthroplasty (LFA) has become the method of choice for patients with destroyed arthritic hip joints; the authors' 18-26-year observation suggests that LFA could be considered the gold standard for total hip arthroplasty (THA). The continuity of concept, design, and the surgical technique extends beyond 29 years and offers predictability of outcome. Fatal postoperative pulmonary embolism, initially at 0.7% within one year of surgery, shows significant seasonal variation and as yet unexplained declining incidence. Incidence of dislocation is 0.63%, with a 0.11% chance of revision. The incidence of deep infection is 0.3%-1.5% in primary surgery and varies with the underlying hip pathology. Introduction of the intramedullary bone block has reduced the revision rate for stem loosening to less than 1% at 14 years and completely eliminated stem fracture. There has not been a fracture of a recently manufactured stem (Ortron). Revision for socket loosening has been reduced to 3% by the introduction of the ogee-flanged socket. The outcome of the socket survivorship is determined by the depth of socket penetration, the relationship between the two being exponential. Because the socket demarcation and migration are usually asymptomatic, the timing of revision would be determined by the surgeon's awareness of the problem. Repeated revisions produce conditions almost comparable to a locally malignant condition: dwindling bone stock, increasing implant size, local recurrence of the problem. Accumulation of the experience with the Charnley LFA has been shown to benefit both old and young patients.

Adult↗

Quality of the surface finish of the head of the femoral component and the wear rate of the socket in long-term results of the Charnley low-friction arthroplasty.

Four Charnley femoral stems, removed on average 20 years after implantation, were examined for the quality of surface finish of the head. The average roughness was 0.031 microns (range 0.008-0.102 microns) as compared with 0.019 microns (range 0.008-0.031 microns) for the current production models and 0.05 microns as recommended by the British Standard and the International Standards Organization. The average socket penetration rate was 0.022 mm/year and there was no radiological or operative evidence of socket loosening. The findings emphasize the importance of achieving and maintaining good surface finish of the head of the femoral component. A suggestion is also made that the orientation of the asperities may be important.

Bone Cements↗

Charnley low-friction arthroplasty: 19- to 25-year results.

Our review of 54 patients (57 Charnley low friction arthroplasties) with a 19 to 25 year follow up shows that clinical results remain excellent; clinical results bear no relation to the radiologic appearances of the bone-cement interface on the acetabular side; and the long-term problem is socket wear. The need for regular follow up and study of factors affecting socket wear is emphasized.

Adult↗

Charnley low-friction arthroplasty in the young patient.

One thousand three hundred forty-two Charnley low-friction arthroplasties (LFAs) were reviewed at an average of ten years four months after surgery. Patients' average age at surgery was 41 years. The clinical results at follow-up review remained excellent: 79% were pain free and 11% had no more than occasional discomfort. One hundred forty-one (10.5%) LFAs have been revised so far. Stem fracture has been completely eliminated. Revision for stem loosening has been reduced to below 1% and revision for socket loosening has also been reduced. The long-term problem remains socket wear--and with it--an increasing incidence of socket migration. Failure of component fixation is a short- and medium-term problem that has been improved by better component design and surgical technique.

Adolescent↗

A tribological study of retrieved hip prostheses.

One hundred Charnley cemented acetabular cups, 78 of which had the associated femoral stems, were obtained after revision surgery. Patient characteristics, which were obtained from hospital records, and roentgenographs showed that component loosening was the most common cause of failure. Examination of the acetabular cups revealed six categories of damage: socket erosion, rim wear, cement ingress, cratering, discoloration, and articulating surface scoring. Damage to the femoral stems was characterized by stem fracture and roughening of the femoral head. The latter was predominantly caused by the roentgenographic contrast medium within the acrylic cement scratching the articulating surface. The amount of wear, in terms of the penetration of the femoral head into the acetabular cup, could be measured in 87 cases. The mean penetration was 1.69 mm and the mean penetration rate was 0.21 mm per year with a range from less than 0.005 mm to 0.6 mm per year. It was shown that within this group, a high penetration rate precludes a long service life. It is therefore likely that reducing the rate of wear would improve the performance of the artificial hip joint.

Acetabulum↗

Fatal pulmonary embolism after total hip arthroplasty. Seasonal variation.

A review of records of 18,104 Charnley low-friction arthroplasties, performed during a 17-year period, shows a 0.7% incidence of fatal pulmonary embolism. Ninety percent occurred within four weeks of surgery and 71% were submitted to postmortem examination. There was a strong seasonal variation. The incidence from November through February was 1% as compared with 0.42% for the remainder of the year. The difference was statistically significant at 0.01 greater than p greater than 0.001 level. There was no significant seasonal variation in deaths from other causes.

Hip Prosthesis↗

Short stem in Charnley low-friction arthroplasty--a review of 100 cases.

One hundred cases of the Charnley low-friction arthroplasties using shorter (75-110 mm) than standard length stems, both in primary and revision surgery were reviewed. The average follow up was five years and three months. Eleven had cortical thickening that could be attributed to the predicted increase in the stresses within the femoral cortex. There were no cases of cortical thickening when the stem was 100 mm or longer. One stem in the 80-84 mm group was revised for loosening. The findings suggest that other than cortical thickening, which has not progressed during the period of the follow-up, there is no need to fear the use of shorter stems if indicated for technical reasons and provided good stem fixation can be achieved.

Adult↗

Polyethylene wear from retrieved acetabular cups.

Laboratory wear testing of ultra high molecular weight polyethylene from 12 Charnley acetabular cups, removed after periods of up to 17.5 years showed that the large patient-to-patient variations in clinical penetration rate cannot be explained by batch-to-batch variation in the wear resistance of the material. Nor was there any evidence of a time-dependent degradation in wear resistance of the material.

Acetabulum↗

Re-attachment of the un-united trochanter in Charnley low friction arthroplasty.

In a prospective study, a double crossover wire with a compression spring was used to re-attach 52 un-united trochanters at revision operations on total hip arthroplasties. Bony union was achieved in 42 (81%) and was not influenced by the duration of the nonunion or the separation gap. The new method compared favourably with earlier revisions at which other methods of trochanteric re-attachment had been used.

Adult↗