Surface coil assembly with switchable field of view.

The authors designed and built an overlapping surface coil assembly for magnetic resonance imaging of the spine. A small and a large coil are included, and use of one can be switched to the other without need for patient repositioning. The images are not degraded, and screening studies can immediately be followed by detailed studies.

Humans↗

A comparison of saddle-shaped and solenoidal coils for magnetic resonance imaging.

Differences in magnetic resonance (MR) imaging signal-to-noise (S/N) performance between saddle-shaped and solenoidal coils have been postulated. Each coil shape is tied to a particular magnetic field configuration, so that they are not typically interchangeable except in special situations. The solenoidal coil is predicted to have a two- to three-fold advantage over the saddle-shaped coil. Simple basic arguments raise a dispute with this assertion. Experiments show that both coils produce essentially equivalent S/N levels.

Animals↗

High-resolution magnetic resonance imaging. Technical concepts and their implementation.

In magnetic resonance (MR) imaging manipulating spatial resolution, contrast resolution, and imaging time separately results in improvement in some parameters without degradation of others. The authors have found that MR imaging of the head with a repetition time TR = 2.0 seconds produces images with high signal-to-noise levels and excellent sensitivity to demyelinating disease and brain water content. In the body, a long TR yields large signal levels that permit delineation of low-intensity structures such as patent vessels and bone. The long TR technique can be used in a high-resolution mode (256 X 256 data acquisition elements, each 0.8 X 0.8 mm) while maintaining image times of 50 or 100 sec/section. For normal resolution (1.7 X 1.7 mm), imaging time is 25 or 50 sec/section. It is concluded that the combination of slow-imaging techniques with simultaneous multisection imaging will prove practical for clinical MR.

Brain↗

Magnetic resonance imaging: effects of magnetic field strength.

Magnetic resonance images of the head, abdomen, and pelvis of normal adult men were obtained using varying magnetic field strength, and measurements of T1 and T2 relaxations and of signal-to-noise (SN) ratios were determined. The T1 relaxation of gray matter, white matter, and muscle increases and T2 decreases with field strength, while T1 of fat remains relatively constant and T2 increases. As a consequence, for any one spin echo sequence, gray/white matter contrast decreases and muscle/fat contrast increases with field. SN levels rise rapidly up to 3.0 kgauss and then change more slowly, actually dropping for muscle. The optimum field for magnetic resonance imaging depends on tissue type, body part, and imaging sequence, so that it does not have a unique value. Magnetic resonance systems that operate in the 3.0-5.0 kgauss range achieve most or all of the gains that can be achieved by higher magnetic fields.