PubMed Health⌕ Search

Biomedical subjects

B Mijnheer

Publications and source records attributed to B Mijnheer.

14 recordsLinked to original sources

Quality assurance of EORTC trial 22922/10925 investigating the role of internal mammary--medial supraclavicular irradiation in stage I-III breast cancer: the individual case review.

To assess consistency among participants in an European Organisation for Research and Treatment of Cancer (EORTC) phase III trial randomising between irradiation and no irradiation of the internal mammary and medial supraclavicular (IM-MS) lymph nodes, all participating institutes were invited to send data from 3 patients in each arm as soon as they started accrual. The evaluation focused on eligibility, compliance with the radiotherapy guidelines, treatment techniques and dose prescription to the IM-MS region. Nineteen radiotherapy departments provided a total of 111 cases, all being eligible. Minor discrepancies were found in the surgery and pathology data in almost half the patients. Major radiotherapy protocol deviations were very limited: 2 cases of unwarranted irradiation of the supraclavicular region and a significant dose deviation to the internal mammary region in 5 patients. The most frequently observed minor protocol deviation was the absence of delineation of the target volumes in 80% of the patients. By detecting systematic protocol deviations in an early phase of the trial, recommendations made to all the participating institutes should improve the interinstitutional consistency and promote a high-quality treatment.

Breast Neoplasms↗

Tolerances for the accuracy of photon beam dose calculations of treatment planning systems.

BACKGROUND AND PURPOSE: To design a consistent set of criteria for acceptability of photon beam dose calculations of treatment planning systems. The set should be applicable in combination with a test package used for evaluation of a treatment planning system, such as the ones proposed by the AAPM Task Group 23 or by the Netherlands Commission on Radiation Dosimetry. RESULTS: Tolerances have been defined for the accuracy with which a treatment planning system should be able to calculate the dose in different parts of a photon beam: the central beam axis and regions with large and small dose gradients. For increasing complexity of the geometry, wider tolerances are allowed, varying between 2 and 5%. For the evaluation of a large number of data points an additional quantity, the confidence limit, has been introduced, which combines the influence of systematic and random deviations. The proposed tolerances have been compared with other recommendations for a number of clinically relevant examples, showing considerable differences, which are partly due to the way the complexity of the geometry is taken into account. Furthermore differences occur if criteria for acceptability of dose calculations are related either to the local dose value or to a normalized dose value. CONCLUSIONS: Although it is acknowledged that the general aim must be to have good agreement between dose calculation and the actual dose value, e.g. within 2% or 2 mm, current day algorithms and their implementation into commercial treatment planning systems result often in larger deviations. A high accuracy can at present only be achieved in relatively simple cases. The new set of tolerances and the quantity confidence limit have proven to be useful tools for the acceptance of photon beam dose calculation algorithms of treatment planning systems.

Algorithms↗

The width of margins in radiotherapy treatment plans.

Publication of ICRU Reports 50 and 62 has highlighted the need to devise protocols for the process of drawing the planning target volume (PTV) around the clinical target volume (CTV). The margin surrounding the CTV should be wide enough to account for all geometric errors so that no part of the CTV accumulates a dose less than, for instance, 95% of that prescribed. One approach to the problem has been to draw a margin around the CTV delineated at the treatment preparation stage which is sufficiently wide that the mean position of the CTV will be encompassed in a specific percentage of cases, for example 90%. This accounts for the systematic errors. A further margin is then drawn to account for random set-up and organ-motion uncertainties during treatment. The width of this second margin has previously been shown to be 1.64(sigma - sigmap). Here sigma, a vector quantity, is the standard deviation which results from convolving the penumbra spread function of standard deviation sigmap with the Gaussian distributions of the daily positional uncertainties of organ motion and set-up error. However, it is shown in this paper that the calculation should take into account the beam configuration of the treatment plan. In a typical coplanar multibeam plan, usually in the transverse plane, any given edge of the target volume is normally defined by a single beam or two parallel and opposed beams. However, because of the presence of the other beams, the effect of the blurring of the edge-defining beam(s) is reduced, which changes the value of the required margin to beta (sigma - sigmap) where, for example, beta can be as low as 1.04 in the transverse plane of a three-beam plan. The width of the required margins is calculated for up to six beams and presented in a table. It is shown that, while the table was derived using an idealized plan of equally weighted plane beams irradiating a spherical target, it is also valid for non-uniform beam weightings, wedged-beam plans, target volumes of general shape and intensity-modulated radiotherapy (IMRT).

Humans↗

Dependence of the tray transmission factor on collimator setting and source-surface distance.

When blocks are placed on a tray in megavoltage x-ray beams, generally a single correction factor for the attenuation by the tray is applied for each photon beam quality. In this approach, the tray transmission factor is assumed to be independent of field size and source-surface distance (SSD). Analysis of a set of measurements performed in beams of 13 different linear accelerators demonstrates that there is, however, a slight variation of the tray transmission factor with field size and SSD. The tray factor changes about 1.5% for collimator settings varying between 4x4 cm and 40 x 40 cm for a 1 cm thick PMMA tray and approximately 3% for a 2 cm thick PMMA tray. The variation with field size is smaller if the source-surface distance is increased. The dependence on the collimator setting is not different, within the experimental uncertainty of about 0.5% (1 s.d.), for the nominal accelerating potentials and accelerator types applied in this study. It is shown that the variation of the tray transmission factor with field size and source-surface distance can easily be taken into account in the dose calculation by considering the volume of the irradiated tray material and the position of the tray in the beam. A relation is presented which can be used to calculate the numerical value of the tray transmission factor directly. These calculated values can be checked with only a few measurements using a cylindrical beam coaxial miniphantom.

Models, Theoretical↗

Effect of electron contamination on scatter correction factors for photon beam dosimetry.

Physical quantities for use in megavoltage photon beam dose calculations which are defined at the depth of maximum absorbed dose are sensitive to electron contamination and are difficult to measure and to calculate. Recently, formalisms have therefore been presented to assess the dose using collimator and phantom scatter correction factors, Sc and Sp, defined at a reference depth of 10 cm. The data can be obtained from measurements at that depth in a miniphantom and in a full scatter phantom. Equations are presented that show the relation between these quantities and corresponding quantities obtained from measurements at the depth of the dose maximum. It is shown that conversion of Sc and Sp determined at a 10 cm depth to quantities defined at the dose maximum such as (normalized) peak scatter factor, (normalized) tissue-air ratio, and vice versa is not possible without quantitative knowledge of the electron contamination. The difference in Sc at dmax resulting from this electron contamination compared with Sc values obtained at a depth of 10 cm in a miniphantom has been determined as a multiplication factor, Scel, for a number of photon beams of different accelerator types. It is shown that Scel may vary up to 5%. Because in the new formalisms output factors are defined at a reference depth of 10 cm, they do not require Scel data. The use of Sc and Sp values, defined at a 10 cm depth, combined with relative depth-dose data or tissue-phantom ratios is therefore recommended. For a transition period the use of the equations provided in this article and Scel data might be required, for instance, if treatment planning systems apply Sc data normalized at d(max).

Electrons↗

First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose.

BACKGROUND AND PURPOSE: Recently, algorithms have been developed to derive the patient dose from portal dose measurements using a liquid-filled electronic portal imaging device. These algorithms have already been validated for several phantom geometries irradiated under clinical conditions. It is the aim of the present study to investigate the applicability of a liquid-filled electronic portal imaging device in combination with these algorithms for two-dimensional midplane dose verification in clinical practice. MEASUREMENTS AND METHODS: Portal dose images were obtained during several patient treatments under routine clinical conditions. Measurements were performed to verify the midplane dose during radiotherapy of larynx cancer with 4 MV beams, breast and lung cancer with 8 MV beams and prostate cancer with both 8 and 18 MV beams. Midplane doses, determined from portal dose measurements and analyzed with our algorithms, were compared with midplane doses calculated with our three-dimensional (3D) treatment planning system (TPS). RESULTS: For the larynx treatment the measured 2D midplane dose agreed within 2.0% with TPS calculations in most parts of the field. Larger differences were found in a small region below the skin due to the absence of electron equilibrium, which is not taken into account in our portal dose analysis. For breast irradiations the measured midplane dose showed a homogeneous distribution in the AP direction in the axial plane, while high dose regions were observed in the cranial and caudal part of the breast. Portal dose measurements and TPS calculations agreed within 2.5% for most of the prostate and lung irradiations. For a few of the prostate and lung treatments larger local differences were found due to differences between the actual patient anatomy and the planning CT data, e.g. as a result of variable gas filling in the rectum and anatomical changes in the lung. CONCLUSIONS: Portal dose measurements with a liquid-filled electronic portal imaging device can be used to determine the 2D midplane dose for various treatment sites in clinical practice. Portal in vivo dosimetry has proven to be important in detecting changes in the patient's anatomy and its influence on the dose delivery. It is concluded that portal dosimetry is an excellent tool for accurate and independent verification of the dose in the entire (2D) midplane during patient treatment. However, a limited number of patients were involved in this study and the results are therefore preliminary. More research is needed to fully assess the clinical value of portal dose measurements.

Algorithms↗

Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model.

BACKGROUND AND PURPOSE: To determine the accuracy of two-dimensional exit dose measurements with an electronic portal imaging device, EPID, using a convolution model for a variety of clinically relevant situations. MATERIALS AND METHODS: Exit doses were derived from portal dose images, obtained with a liquid-filled EPID at distances of 50 cm or more behind the patient, by using a convolution model. The resulting on- and off-axis exit dose values were first compared with ionization chamber exit dose measurements for homogeneous and inhomogeneous phantoms in open and wedged 4,8 and 18 MV photon beams. The accuracy of the EPID exit dose measurements was then determined for a number of anthropomorphic phantoms (lung and larynx) irradiated under clinical conditions and for a few patients treated in an 8 MV beam. The latter results were compared with in vivo exit dose measurements using diodes. RESULTS: The exit dose can be determined from portal images with an accuracy of 1.2% (1 SD) compared with ionization chamber measurements for open beams and homogeneous phantoms at all tested beam qualities. In the presence of wedges and for inhomogeneous phantoms the average relative accuracy slightly deteriorated to 1.7% (1 SD). For lung phantoms in a 4 MV beam a similar accuracy was obtained after refinement of our convolution model, which requires knowledge of the patient contour. Differences between diode and EPID exit dose measurements for an anthropomorphic lung phantom in an 8 MV beam were 2.5% at most, with an average agreement within 1% (1 SD). For larynx phantoms in a 4 MV beam exit doses obtained with an ionization chamber and EPID agreed within 1.5% (1 SD). Finally, exit doses in a few patients irradiated in an 8 MV beam could be determined with the EPID with an accuracy of 1.1% (1 SD) relative to exit dose measurements using diodes. CONCLUSIONS: Portal images, obtained with our EPID and analyzed with our convolution model, can be used to determine the exit dose distribution with an accuracy of 1.7% (1 SD) for most clinically relevant situations. EPID exit dosimetry is therefore a good alternative for diode dosimetry. The EPID system is a powerful tool in a dosimetric quality control programme during high dose/high precision radiotherapy.

Humans↗

Transmission dosimetry with a liquid-filled electronic portal imaging device.

PURPOSE: To assess the accuracy of transmission dose rate measurements for various phantom-detector geometries, performed with an electronic portal imaging device (EPID) and to compare these transmission dose rate values with exit dose rate data. METHODS AND MATERIALS: Transmission dose rate values on the central beam axis and beam profiles were measured with an EPID consisting of a matrix of liquid-filled ionization chambers. These data were compared with transmission and exit dose rate values, obtained using air-filled ionization chambers for a number of field sizes, phantom thickness, and phantom-detector distances. Various homogeneous and inhomogeneous phantoms were applied. RESULTS: The increase in dose rate with field size is larger for the EPID than in air, due to the larger amount of side scatter in the EPID. The difference has been taken into account by a deconvolution of the EPID images. An additional build-up layer on top of the commercial device is needed to reach dose maximum at the liquid ionization chambers for photon beam energies higher than about 4 MV. The transmission off-axis ratios (OAR) determined with the EPID and in air agreed within 2% for all tested cases, after deconvolution of the EPID signal. The agreement between the EPID-and exit-OAR decreased with increasing phantom-detector distance and the presence of inhomogeneities. For a phantom-detector distance of about 10 cm, the EPID- and exit-OARs agree within 2.5%. The difference could be up to 8% for an air inhomogeneity and a phantom-detector distance of 30 cm. CONCLUSIONS: The difference between EPID measurements and measurements in air can be explained by side scatter effects in the EPID and lack of adequate buildup, and can easily be taken into account. The loss of scatter compared with the situation at the exit side of the phantom explains the difference between transmission and exit dose values. At short phantom-detector distances, good agreement exists between transmission and exit dose rate. This implies that at this distance, the EPID can be used for simple comparison with exit dose calculations during patient treatments. At larger distances, more sophisticated conversion methods are required.

Models, Anatomic↗

Quality assurance in radiotherapy: the importance of medical physics staffing levels. Recommendations from an ESTRO/EFOMP joint task group.

The safe application of ionising radiation for diagnosis and therapy requires a high level of knowledge of the underlying processes and of quality assurance. Sophisticated modern equipment can be used effectively for complicated diagnostic and therapeutic techniques only with adequate physics support. In the light of recent analyses and recommendations by national and international societies a joint working group of representatives from ESTRO (European Society for Therapeutic Radiology and Oncology) and from EFOMP (European Federation of Organisations for Medical Physics) was set up to assess the necessary staffing levels for physics support to radiotherapy. The method used to assess the staffing levels, the resulting recommendations and examples of their practical application are described.

Europe↗

A comparison of build-up and depth dose characteristics of different photon beams for the treatment of Hodgkin's disease.

Measurements have been performed of build-up and depth-dose characteristics of photon beams under Hodgkin's disease treatment conditions as applied in two hospitals (AVL, Amsterdam and IGR, Villejuif). Although different types of accelerators, photon energies, field sizes and SSD are employed, similar dose distributions along the beam axis have been obtained in both centers. In order to explain this unexpected good agreement, the influence of the geometrical conditions of irradiation on the build-up and depth-dose distribution has been studied in detail for five photon beams (8 MV-25 MV) of three types of accelerators.

Evaluation Studies as Topic↗