PubMed HealthSearch

Biomedical subjects

B Mockbee

Publications and source records attributed to B Mockbee.

5 recordsLinked to original sources

Comparison of conventional and computed radiography: assessment of image quality and reader performance in skeletal extremity trauma.

RATIONALE AND OBJECTIVES: Reader performance and image quality wee assessed for standard film, computed film, and computer monitor radiography viewing formats in the evaluation of skeletal extremity trauma. MATERIALS AND METHODS: Three radiologists and three orthopedic surgeons interpreted 27 skeletal radiographs obtained with equivalent technical parameters. Readers evaluated standard film, computed film, and computer monitor formats randomly for fracture and soft-tissue abnormalities. Sessions were videotaped, and eye motion was recorded. RESULTS: No statistically significant differences were found between image formats for true-positive or false-positive findings of trauma indicators. Findings were classified as false-negative based on eye position fixation times. Search errors (lesion not fixated) accounted for 21.7%, 20.6% and 17.1% of false-negative errors with the computer monitor, computed film, and standard film formats, respectively. Combined recognition errors and decision errors were 78.3%, 79.4%, and 82.9%, respectively. Viewing times were longest for the computer monitor images (P < .001). Image quality, contrast, and sharpness were rated highest for computed radiographs (P = .001). Radiologists had a higher true-positive decision rate than orthopedic surgeons (P = .03). CONCLUSION: No statistically significant differences were seen in reader performance among viewing formats. The computed film format received the highest quality rating, and workstation viewing times were longest.

Adolescent

Excretory urography using computed radiography.

A computed radiographic system for generating digital film images was evaluated in the performance of excretory urography. Three experienced radiologists reviewed digital and conventional screen-film urograms for 100 patients in a prospective study to evaluate the clinical utility of the digital system. Results indicate no difference between digital and screen-film urograms in diagnostic sensitivity, specificity, or receiver-operating-characteristic curves for differentiating normal from abnormal studies. Readers' performances in making specific diagnoses were also the same with both techniques.

Humans

Mammogram interpretation by physician assistants.

The objective of this study was to determine whether a health maintenance organization (HMO) desirous of providing low-cost, quality mammography could employ physician assistants (PAs) to interpret mammograms under the supervision of HMO radiologists. After intensive training in mammographic interpretation, four PAs individually interpreted 727 mammograms of 470 normal breasts, 75 breasts with benign breast masses, and 182 breasts with cancer. The interpretations by the PAs were more sensitive and as specific as those made by six HMO radiologists who interpreted the same cases, and as effective as those by radiologists described in the literature. In receiver-operating-characteristic curve analysis, the areas under curves for PAs were larger than those under curves for radiologists. Interpretations by PAs took less time and cost less than did those by radiologists; the dispositions recommended by PAs were similar to those recommended by radiologists. We conclude that properly trained, evaluated, and supervised PAs can interpret mammograms. Legal, practical, and ethical considerations dictate that this can best be accomplished under the direction of radiologists who are well trained in mammography.

Female

Computed tomography and automated image analysis of prehistoric femora.

Non-invasive characterization of limb bone cross-sectional geometry would be useful for biomechanical analyses of skeletal collections. Computed tomography (CT) is potentially the method of choice. Additionally, CT images are suitable for automated analysis. CT is here shown to be both accurate and precise in the analysis of cross-sectional geometry of prehistoric femora. Beam hardening artifacts can be reduced by using a water bath. As the availability of CT for research increases, both bone density and geometry could be determined simultaneously with this method.

Autoanalysis

Conventional vs computed radiography: evaluation of myelography.

A prospective study was performed to compare the diagnostic efficacy of conventional film-screen (FS) imaging with computed radiography (CR) in myelography. Forty examinations were done with both methods. Digital myelography was found to have diagnostic accuracy equal to that of conventional film-screen examinations.

Diagnosis, Computer-Assisted