PubMed Health⌕ Search

Biomedical subjects

B N Landis

Publications and source records attributed to B N Landis.

4 recordsLinked to original sources

Clinical presentation of qualitative olfactory dysfunction.

Many patients with olfactory dysfunction not only experience quantitative reduction of olfactory function, but also suffer from distorted olfactory sensations. This qualitative dysfunction is referred to as parosmia (also called "troposmia") or phantosmia, with the major difference that distorted olfactory sensations are experienced in the presence or absence of an odor, respectively. Our clinical observations corroborate the literature in terms of a general underestimation of the incidence of olfactory distortions. Based on selected cases we try to show that olfactory distortions exhibit a large variance in their clinical appearance. Further, emphasis is placed on the fact that only a detailed and directed history of the patient can provide cues to the correct diagnosis.

Adult↗

Somato-sympathetic vasoconstriction to intranasal fluid administration with consecutive decrease in nasal nitric oxide.

AIM: Patients suffering from non-allergic chronic rhinosinusitis (NACRS) increasingly use intranasal saline sprays. They report better nasal comfort. METHODS: In order to better understand this phenomenon, we studied intranasal laser Doppler flowmetry (LDF) and nasal nitric oxide (NO) variations evoked by local administration of saline, histamine, N-acetylcysteine (NAC) and lidocaine at room temperature (22 degrees C). RESULTS: There was a significant (P < 0.05) 14 +/- 3.8% decrease in LDF signal after 30 s, which lasted for 60-90 s, for all the substances applied at 22 degrees C. This pharmaco-independent vasoconstriction was further studied in patients under general anaesthesia (GA), with saline at 37 degrees C and after intranasal adrenaline treatment. While GA did not influence the vasoconstriction, saline at 37 degrees C and adrenaline pre-treatment abolished it. Nasal NO is influenced by vasoconstriction. Therefore we investigated, whether the observed vasoconstriction also changes nasal NO. A significant (P < 0.001) 8.03 +/- 0.59% decrease in nasal NO was recorded 60 s after administration of all the substances, and under GA after 22 degrees C saline application. This NO decrease was absent after intranasal adrenaline pre-treatment. An additional experiment tested the effect of nose blowing on nasal NO concentration. We registered an NO decrease with a similar pattern than observed with the other substances. CONCLUSIONS: Intranasal fluid nebulization at 22 degrees C induces a sympathetic mediated, transient vasoconstrictor reflex response. This somato-sympathetic vasoconstriction induces a decrease in nasal NO. Both could be related to the subjective comfort experienced by NACRS patients using intranasal saline sprays.

Acetylcysteine↗

Ratings of overall olfactory function.

The aim of this study was to investigate the accuracy of self-reported ratings of olfactory function in 83 healthy subjects. Such ratings were compared with quantitative measures of olfactory function, as well as with ratings of nasal patency. In experiment 1 subjects rated olfactory function and nasal patency before olfactory testing, whereas in experiment 2 the reverse was the case. No feedback regarding test results were provided until after completion of the testing. The principal findings were: (i) when ratings preceded measurements of olfactory function, there was no significant correlation between the two parameters. However, ratings of olfactory function correlated significantly with ratings of nasal airway patency. (ii) In contrast, when measurements of olfactory function preceded the ratings, this constellation switched. Now ratings of olfactory function correlated significantly with measured olfactory function, whereas there was no significant correlation between ratings of nasal airway patency and ratings of olfactory function. In conclusion, these data suggest that ratings of olfactory function are unreliable in healthy, untrained subjects. The ratings seem to reflect changes of nasal airway patency to a larger degree than measurable olfactory function. The results further indicate that this is mainly due to the limited attention the sense of smell receives in daily life.

Adult↗

Comparison of once- versus twice-daily use of beclomethasone dipropionate aqueous nasal spray in the treatment of allergic and non-allergic chronic rhinosinusitis.

The aim of the study was to assess the efficacy and safety of nasal aqueous beclomethasone dipropionate (BDP), 400 micro g/day, given via a metered pump in a once-daily or twice-daily regimen following a double-blind, parallel group design over a 12-week period. Adult patients (n=112) with allergic or non-allergic chronic rhinosinusitis recorded their nasal and ocular symptoms for the 7-day run-in period and for the first 4 weeks of treatment. At baseline and after 4 weeks the airways' resistance via active anterior rhinomanometry and the volume and area section via acoustic rhinometry were measured. Morning serum cortisol was measured at baseline and at week 12. Adverse events were to be reported at each visit. Of the 112 randomised patients, three did not enter the ITT analysis and another 13 in total discontinued the treatment. Significant improvements over the baseline were reported in both groups for the primary variable sum of nasal scores (-53.7% in the once-daily group and -59.7 in the twice-daily group), as well as for each nasal and ocular symptoms, without differences between the groups. Because of a wider variability than expected, the 95% confidence interval (C.I.) for the difference between the least square means exceeded the pre-defined limit of +/-10% of the reference mean. Similar improvements in both groups were also reported for the nasal airway patency's parameters. The total number of drug-related adverse events was 26 in the once-daily group and 32 in the twice-daily group, with most of the events consisting of local effects at the site of application. No signs of adrenal suppression were observed, and serum morning cortisol values did not significantly change. The once-daily BDP dosing (400 micro g/day) therefore has a similar efficacy and safety profile as the same daily dose given in a twice-daily regimen.

Administration, Intranasal↗