PubMed Health⌕ Search

Biomedical subjects

B N Stulberg

Publications and source records attributed to B N Stulberg.

At least 37 records · Page 2Linked to original sources

Osteonecrosis of the femoral head. A prospective randomized treatment protocol.

Conservative treatment versus core decompression for cases of osteonecrosis (ON) of the femoral head was prospectively reviewed in 36 patients. A preoperative evaluation of the patients' history, physical examination, Harris Hip Score, roentgenograms, computed tomography, bone scan, magnetic resonance imaging, and measurement of the intraosseous pressure was used to grade the level of ON according to a rating system developed by Ficat. Hips were randomized to core decompression or conservative treatment groups. Fifty-five hips in 36 patients were randomized (29 surgical and 26 conservative). When success was gauged by Harris Hip Scores for Stage I hips, treatment was successful for seven of ten (70%) operatively treated hips and one of five (20%) non-operatively treated hips. Among Stage II hips, treatment was successful for five of seven (71%) decompressed hips and none of seven conservatively treated hips. Successful treatment was accomplished in eight of 11 hips (73%) and one of ten hips (10%) in decompression and conservative groups, respectively, for Stage III hips. Stages 0 and IV had groups too small for comparison. Less successful results were seen if roentgenographic criteria of success were used. Survival analysis showed more favorable results with surgical treatment. Core decompression produced better results than conservative treatment in the early stages of ON.

Adolescent↗

Expandable breast implant reconstruction of Tikhoff-Linberg shoulder deformity.

Expanding breast implants were used in two patients to reconstruct shoulder contour following a Tikhoff-Linberg resection for cancer. In the first patient, one implant alone was used, and in the second patient, two implants in separate but adjacent pockets. The resulting double contour is more pleasing than that after a single implant, and there also appears to be more flexibility with shoulder motion. This method is suggested as an excellent means of reconstructing the contour of the shoulder area following resection for cancer.

Breast↗

Prevention of venous thrombosis after total knee arthroplasty. Comparison of antithrombin III and low-dose heparin with dextran.

In a prospective, randomized trial, we compared the efficacy of a combination of antithrombin III and heparin with that of dextran 40 as prophylaxis against venous thrombosis after total knee arthroplasty. Ascending venography identified thrombosis in about one-third of the patients who received the combination of antithrombin III and heparin, compared with about four-fifths of those who received dextran (p less than 0.001). In both groups, the patients who had venous thrombosis had a significantly lower concentration of antithrombin III postoperatively than those who did not have thrombosis. Venous thrombosis occurred in all patients in whom the concentration of antithrombin III was less than 65 per cent postoperatively. These findings demonstrated that, after total knee replacement, the combination of antithrombin III and heparin effectively reduces the incidence of postoperative venous thrombosis and is significantly better than dextran. Furthermore, the findings suggested a relationship between postoperative deficiency of antithrombin III and the occurrence of thrombotic complications.

Adult↗

Making core decompression work.

Meaningful assessment of a treatment modality for osteonecrosis (ON) must take into account a number of factors: (1) an accurate diagnosis, (2) consistent staging of the disease process, (3) understanding of the variability of the disease, (4) consistent application of the treatment modality (or the surgical technique), and (5) a clear understanding of the goal of the treatment used. This article reviews the important steps of a diagnostic algorithm that has been used to accurately diagnose and stage the disease process of ON. A consistent surgical technique with clearly defined goals is also outlined. The results of two clinical studies that were based on these diagnostic and therapeutic philosophies and that assess the role of core decompression in the treatment of ON are reviewed. The first study compared core decompression to conservative management in a prospective randomized study of 55 hips. Decompression provided more predictable pain relief and changed the indications for further surgical intervention more consistently than did conservative management. The second study represents a preliminary review of a ten-year study of the decompression procedure; it showed that core decompression was particularly useful in Stage I and Stage II ON. Roentgenographic stabilization was most predictable for Stage I hips. Core decompression can be a safe, effective, and predictable procedure in the treatment of Stage I and Stage II ON.

Adult↗

The incorporation of tibial allografts in total knee arthroplasty.

Twelve knees in ten patients had revision total knee replacement with insertion of an allograft for a large tibial defect. The knees were retrospectively evaluated at an average of thirty-two months (range, twenty-five to fifty-one months) by clinical examination, radiography, planar bone scintigraphy, and single-photon-emission computed tomography. The average age of the patients was sixty-two years (range, fifty-four to seventy-nine years). A constrained total-condylar prosthesis was used for all revisions. A contained tibial defect was present in five knees, and seven knees had an uncontained defect that was treated with a massive composite structural allograft, five of which were secured with internal fixation. The knee scores improved from an average of 51 points before operation to an average of 87 points post-operatively. Seven knees had a score of 85 points or more and were considered to have an excellent clinical result. Two knees had a good result, with scores of 77 and 72 points. One knee had another revision because of painful non-union of a medial structural graft, and the result in that knee was considered a failure. The average range of motion improved from 84 degrees to 105 degrees. There were no deep infections, and no graft showed evidence of fracture or collapse. Radiographs demonstrated complete incorporation of the graft in eleven of the twelve knees at an average of twenty-three months after operation. Single-photon-emission computed-tomography scans showed uniform activity in the area of the graft in four of the five knees that were studied.

Aged↗

Fat embolism associated with cementing of femoral stems designed for press-fit application.

The authors report four cases of fat embolism syndrome following total hip arthroplasty using cementless acetabular press-fit components and cemented press-fit femoral components. Factors implicated in the production of this syndrome following "hybrid" total hip arthroplasty include increased canal pressure during femoral reaming and prosthetic insertion, retained marrow elements and reaming debris, and the use of lumbar epidural anesthesia. This potentially fatal syndrome must be a recognized complication following the use of cemented press-fit femoral stems. Specific recommendations for decreasing the incidence of this complication are reviewed.

Aged↗

Management of orthopedic complications of metabolic bone disease.

Orthopedic manifestations of metabolic bone disease are usually related to structural compromise of the skeleton. Fractures due to osteoporosis are the most often encountered problem. In this overview, the authors focus on the commonly encountered fractures related to osteoporosis and discuss concerns and complications related to their management. In addition, they point out the subtle ways in which less commonly encountered metabolic bone diseases, such as osteomalacia, hyperparathyroidism, and Paget's disease, might come to the attention of the orthopedist. Appropriate criteria for medical and surgical management are suggested.

Bone Diseases, Metabolic↗

Antithrombin III/low-dose heparin in the prevention of deep-vein thrombosis after total knee arthroplasty. A preliminary report.

This preliminary report outlines the rationale for a new approach to deep-vein thrombosis (DVT) prophylaxis in total knee arthroplasty (TKA) patients and describes preliminary hematologic and venographic findings. A protocol was employed to (1) document a series of hematologic events surrounding cemented TKA and the alterations of these events by the study drugs and (2) compare the safety and efficacy of a regimen of antithrombin III/low-dose heparin (ATIII/LDH) to that of low-molecular-weight dextran (LMWD) in the prevention of DVT after TKA. Using a dosage regimen of 3000 units of ATIII as a loading dose followed postoperatively by 2000 units daily combined with 5000 units of LDH twice daily, a prospective randomized study of patients treated by cemented TKA was performed. The ATIII/LDH regimen was compared with LMWD (10 ml/kg x 12 hours loading dose followed by 7 ml/kg x 24 hours maintenance dose). The rate of DVT after TKA in 42 patients was 25% (5/20) for the ATIII/LDH group versus 82% (18/22) for the LMWD group (p less than 0.001). Bleeding complications were minimal and comparable for each group. Hematologic studies demonstrated that quantitative and functional ATIII levels decreased after TKA and that preoperative loading with ATIII prevented levels from falling below 100%. Studies of clot formation (fibrinopeptide A) and plasmin activity (fibrinopeptides B beta 15-42 and 1-42) in 34 patients suggest some reduction in procoagulant activity in patients in the ATIII/LDH group. These findings indicate that the combination of ATIII and LDH may offer superior protection from DVT than does LMWD.

Antithrombin III↗

Bone quality. Roentgenographic versus histologic assessment of hip bone structure.

Bone quality is an accepted criterion for determining fixation options for total hip arthroplasty (THA). Eighty patients with 95 uncemented THAs were evaluated by comparing preoperative roentgenographic assessment with histologic evaluation of bone biopsy specimens obtained from the ipsilateral iliac crest. Roentgenographic analysis of bone quality was performed using the Singh and Engh indices. Histologic evaluation employed a quantitative analysis of static and dynamic parameters of bone turnover on undecalcified sections. Extensive statistical analysis comparing roentgenographic with histologic parameters of bone quality showed: (1) no relationship of the two roentgenographic indices to trabecular bone volume and most other histologic parameters and (2) a high incidence of bone abnormalities. Bone quality is an imprecise term and is inadequately measured by these roentgenographic indices. Histologic measurement offers a more precise means of analyzing the relationship of the bone environment to the performance of the THA.

Biopsy↗

A diagnostic algorithm for osteonecrosis of the femoral head.

For patients considered at risk for osteonecrosis (ON) of the femoral head, an algorithm for the efficient and appropriate use of diagnostic tests can be developed. Such an algorithm requires a clear idea of the evolution of the disease process and an understanding of the limitations of each of the modalities by which the disease process can be identified. The role of each of the diagnostic tests available for the diagnosis of ON and the results of prospective evaluations to assess their sensitivity, specificity, and predictive values are reviewed. No single diagnostic test is 100% accurate in the diagnosis of the disease. Thus, one must consider an algorithm that accounts for the variable nature of the disease presentation. The goal of such an algorithm is the accurate identification and staging of the disease. For disease not roentgenographically apparent, an approach using magnetic resonance imaging and bone scanning is recommended. For disease that is apparent roentgenographically, tomography is used to define the extent of the disease and the presence or absence of subchondral fracture. The accuracy of diagnosis is critical to understanding the role of the various treatment modalities prescribed for ON. For this purpose, it is necessary to reach a consensus as to what constitutes a successful outcome of treatment. Once diagnosis of the disease is accepted, clinical success of treatment outcomes should be reported in three ways: by a standard hip rating system, by ability to prevent roentgenographic deterioration, and by survival of the femoral head (the absence of further treatment intervention).(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗

The rationale, design characteristics, and preliminary results of a primary custom total hip prosthesis.

Seventy-three primary custom-made uncemented hip implants have been inserted since July 1987. The initial clinical results are equivalent to those of conventionally made components, but there has been less residual and recurrent thigh pain with the custom devices. The custom implants have achieved 20% greater canal fill with much less variation than conventionally made devices. Custom components have been particularly useful in patients with significant anatomic deformity and associated arthritis.

Bone Cements↗

Multimodality approach to osteonecrosis of the femoral head.

Treatment of osteonecrosis of the femoral head appears to be effective when the disease is identified and treated early. Forty-one patients were evaluated with prospective laboratory assessment, anteroposterior and frog-lateral roentgenograms of both hips, intraosseous pressure measurements (IOP), magnetic resonance imaging (MRI), and 99mTc methylene diphosphonate planar and single-photon emission computerized tomographic (SPECT) bone imaging. Pathologic specimens were obtained in most patients. Preradiographic disease was identified in 26 hips and 11 of these were asymptomatic. Fifteen clinically symptomatic hips had normal plain roentgenograms, but abnormal protocol studies. Evaluation of sensitivity, specificity, and predictive value (positive and negative), respectively, in diagnosing osteonecrosis of the femoral head revealed the following percentages: 83%, 83%, 96%, and 48% for planar bone scanning; 91%, 78%, 94%, and 70% for SPECT; 87%, 83%, 96%, and 55% for MRI; 80%, 60%, 95%, and 25% for IOP; and 88%, 100%, 100%, and 25% for core biopsy. (There were few true negatives, thus specificity values are approximations.) The identification of preradiographic stages is possible, but difficult. MRI appears appealing at present, particularly in identifying disease in asymptomatic hips. However, there is no definitive method for noninvasive diagnosis. Pathologic confirmation in early stages is difficult.

Adolescent↗

Failure mechanisms of metal-backed patellar components.

A specific type of failure of a metal-backed patella occurred, consisting of a separation of the polyethylene from the metal backing. This dissociation is followed by wearing of the metal backing against the femoral component. This produces clinical signs and symptoms that usually require revision. This failure occurred in 16 knees of 14 patients. Average time to failure was 14 months. Failure was associated with patellar implant design, surgical technique, patient characteristics, and femoral component design. The plastic of the metal-backed patellae was thin at the periphery. The metal plate did not extend to the edge of the plastic and acted like a sharp edge that cut the thin plastic. The plastic dome was not bonded to the plate and became separated from the plate once the plastic tore. The plate became deformed. Failure was more likely with a subluxated, tilted, or excessively thick patella or flexed femoral component. The typical patient was a large, active male who had achieved more than 115 degrees of flexion. A prominent edge on the lateral intercondylar ridge of the femoral component resulted in a concentrated load being applied to the plastic dome and favored rapid wear of the patella. Until a greater understanding of patello-femoral loading is acquired, caution in the use of metal-backed patellae is recommended.

Aged↗

Femoral component loosening in hip arthroplasty. Cadaver study of subsidence and hoop strain.

To aid in understanding loosening following cemented total hip arthroplasty, we conducted a cadaver study of the proximal femur with implanted cobalt-chromium and titanium femoral components of recent design, loaded through the head of the prosthesis. Stem subsidence and strain in the proximal femur were measured. After proximal support of the implant collar was removed, we found that cobalt-chromium implants had a greater tendency to subside than titanium implants. Subsidence of a femoral component within the cement mantle caused an increase in tensile hoop strain measured in the proximal cortex. When implants were loaded until failure of the cortex, a direct relationship between increase in subsidence and increase in cortical hoop strain was demonstrated. Our data show that implants that resist subsidence into the cement mantle tend to decrease hoop strains in the proximal femoral cortex.

Bone Cements↗

Elbow arthrography in the evaluation of posterior interosseous nerve compression in rheumatoid arthritis.

This is a case report of a fifty-nine-year-old rheumatoid arthritic woman who developed lack in finger extension bilaterally. These deficits had two completely different aetiologies, Posterior Interosseous Nerve (PIN) Syndrome and extensor tendon rupture. No previous report in the literature has used elbow arthrography as a diagnostic tool in a patient with PIN Syndrome. Elbow arthrography confirmed the abnormality at this joint and aided in appropriate management.

Arthritis, Rheumatoid↗

Allograft reconstruction of the acetabulum during revision total hip arthroplasty. Clinical, radiographic, and scintigraphic assessment of the results.

In twenty-one hips of twenty-one patients, the acetabulum was reconstructed using allografts during revision of a total hip arthroplasty. The patients' average age at the time of revision was 64.3 years (range, nineteen to eighty-six years). At an average follow-up of 3.5 years (range, two to five years), three patients had died of causes unrelated to the hip reconstruction, and one had been lost to follow-up. In the other seventeen, the average Harris hip rating was 89 points (range, seventy to 100 points) at follow-up. In one patient the allograft collapsed, so that revision was required. Two patients had asymptomatic progressive radiolucencies at the cement-bone interface of the reconstructed acetabulum, and another had a 1.5-millimeter-wide lucency at the interface of the donor and recipient bone but was asymptomatic, and there had been no change in the position of the cemented acetabular component since operation. The remaining grafts appeared to be incorporated securely, as determined by radiographic examination. Three-dimensional computerized tomographic radioisotopic bone scans showed uniform uptake, consistent with revascularization and new-bone formation, in all grafts. There was no radiographic evidence of focal avascularity and there were no infections. Femoral-head bone allografts appear to provide a useful technique for the reconstruction of a severely deficient acetabulum during revision total hip arthroplasty.

Acetabulum↗